HomeMy WebLinkAboutSPI2006-00206 - SPI Inspections - 1/22/2009 ok .STA MASON COUNTY
oPy A° °�, DEPARTMENT OF COMMUNITY DEVELOPMENT
> S N Planning Division
° Y ti P O Box 279, Shelton, WA 98584
(360)427-9670
1864
Site Inspection
January 22, 2009
TOM & BARBA REYNOLDS TO BE KEPT IN THE
PO BOX 362 PARCEL FILE
SHERWOOD OR 97140
PAJ ?Zl 3 If c 3 �00�
Case No.: SP12006-00206
Parcel No.: 321341390020
Project Description: Site review for new residence along streams on property.
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below
you will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands
must be included in your specific proposal; these setbacks are included as part of the comments
listed below.
This information is based on County and State regulations as they exist to date. These
regulations may change and may affect the requirements for development of the subject property.
Please contact me at(360)427-9670, ext. 365 if you have questions.
Sincerely,
Allan Borden
Land Use Planner
Mason County Planning Department
1/22/2009 Page 1 of 4 SP12006-00206
Site Inspection
1/22/2009 Case No.: SP12006-00206
Comments:
Pre-inspection for Tom & Barbara Reynolds on Aug. 9, 2006:
The pre-inspection was made to evaluate construction of a
residence and garage on a parcel located on the west side of
Cranberry Creek south of Mikkelson Rd. The 5.2-acre property
has many evergreen or deciduous trees and existing native
vegetation, but no developed area. The parcel has no banks over
12 percent. The proposed new buildings would be located at the
proper setbacks from the two streams on the parcel based upon
this inspection. These findings state regulations in effect at
inspection time, unless noted otherwise.
Development Regulations standards:
_Y_ The site is in Rural Residential 5 zone. Standard building
setbacks are 25-foot front yard setback, and 20-foot side property
line and rear yard setbacks. These setbacks are measured from
structures above grade such as roof overhangs, stairs, balconies,
decks, heat pumps, storage buildings, and fuel tanks.
_Y_ An administrative variance may be requested to reduce
these setback distances from property lines, to as low as 5 feet
(side yard), if the size, shape, or features of the property constrain
development from the proper setbacks. This process requires
application and review at the time of the building permit submittal.
Resource Ordinance Standards:
_N_ Wetland critical area: Planning staff confirmed that the
parcel does not contain certain wetlands, which are regulated
under Mason County's Wetlands chapter 17.01.070 of the Mason
County Resource Ordinance. The applicant will not need a
wetlands special report during development review.
_N_ Slope or Landslide hazards: Slopes 12 percent or less are
adjacent to or within 300 feet of a proposed project were observed
(slopes are 400 to 500 feet away); slumping or seepage
conditions that could contribute to sliding were not observed. The
applicant will not need a geologic special report during
development review.
_Y_ Shoreline setbacks: The shoreline designation for Cranberry
Creek is Conservancy Environment per the Mason County
Shoreline Master Program and development setbacks would be
determined by the Mason County Resource Ordinance. Along the
Cranberry Creek shoreline, the determined 50-foot shoreline
1/22/2009 Page 2 of 4 SP12006-00206
Site Inspection
1/22/2009 Case No.: SP12006-00206
setback from the creek is exceeded by the stream critical area
noted below.
_Y_ Stream setbacks: The setbacks from Cranberry Creek and
type F stream would be determined by the Mason County
Resource Ordinance. The Cranberry Creek setback for a type S
stream is composed of a 150-foot vegetation buffer plus a 15-foot
building setback closest to the roof projection of a proposed
structure. The stream setback for a type F stream on the parcel
to the south is also composed of a 150-foot vegetation buffer plus
a 15-foot building setback closest to the roof projection of a
proposed structure on the subject parcel. Any portion of the new
structure, including decks, balconies, and rooflines, must be
behind this setback line. The 15 feet toward the stream is an area
that may be used for lawns, patios or landscaping (development
at grade level). From that point toward the stream is considered
to be a required vegetated buffer and is regulated by the Mason
County Resource Ordinance Fish and Wildlife Habitat
Conservation Areas Chapter. Within this chapter are those
activities listed that can be done both with and without a Mason
Environmental Permit.
Staff measured the setback from the bank of the Cranberry Creek
to the potential building site; that distance is 200 to 220 feet. The
setback from the bank of the type F stream to the potential
building site on the subject parcel is 160 to 175 feet (noted on the
enclosed rough drawing). As stated above, all portions of the new
development must be behind these stream setback distances
noted at the site inspection.
Site preparation shall limit any clearing or tree removal in the
noted critical area buffers. Replanting areas impacted with the
use of native plants such as huckleberry, salal, ocean spray,
rhododendron, and sword ferns is preferred in the effort to replace
plants removed in the buffer area. A path to the stream, not more
than 3 feet wide, is allowed in the buffer area.
Based on this field review, the presence of the Resource
Ordinance Fish and Wildlife Habitat Conservation Areas, and the
proposed layout of development, there is adequate area that
exists on the subject parcel that would not be encumbered by the
critical area buffer and building setback. The applicant can
choose to reduce the footprint of proposed development on the
property to meet the proper setbacks.
You would need to confirm with the Environmental Health
Department what their septic system standards are to make sure
1/22/2009 Page 3 of 4 SP12006-00206
Site Inspection
1/22/2009 Case No.: SP12006-00206
about the adequacy of supplying a septic disposal for the
proposed development.
General process: Future development must include a site plan,
showing all setbacks from property lines, streams, road, and
existing and proposed improvements; this site plan will be needed
for building permit application submittal and review.
Specific County Codes standards for future development may be
found at the County website address http://www.co.mason.wa.us.
If you have any questions please feel free to call. Thank you.
1/22/2009 Page 4 of 4 SP12006-00206
• $� �� � -�� RECEIVED
w� 1
�p
MASON COUNTY JUL 2 7 2006
PLANNING DEPT. PRE-INSPECTION APPLICATION ��+ CEDAR ST: 1
PLEASE PRINT
) 2 // $�03.a0 Fee Required
1. Owner: � G V O W , r Applicant: OM-1 �R�ORrR e c „U0 4 Z,wP�
Site Address: 6to,�Applicant Address: P.O l�osc 3(0
Owner Address: 2 _eCAJ r. City: SA .r"J0o . St Zip /yv
City: L AAi St G Zip 1.13ru Phone:(�6 03 ) S"y day
Phone:a0;JL y 4g-/g'/7 day
Phone:( evening Planner:
Email Address: SMP ' Comp.Plan Type of Use
1
2. Parcel No. 3 Z 1341 _ / cj . 0020 Water Body
Parcel No. -
Legal Description: I-o t as F SP zt7 kZ PW 7"R 2- Sct w e S $ 3Z.
J 3. Purpose of Pre-Inspection: --re cte-ter� ;/u P U i&al;&J cj 5,f /c Zoe,-//^O A)
o� /J r'i U E.c C.:.4 y i /� L' �-'�i D s� <� S�'L"�.�•9-G/ ,S` /�9.,s-.
_S't
4. Use of building: o r�
5. Do any of the following exist on or adjacent to property?: slope saltwater lake ) river
pond Ma ) wetland ) seasonal runoff other( ) stream k) seasonal creek )
Directions to Site: GU 3 19 r rA -7'cv o S'en;--, <
L d -Td pxlp /--/ �z7 �s e ors r
If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the original
application. Pre-inspection reports remain valid only until development changes occur in the vicinity which affect the lot
evaluated in this inspection,or the laws regulating development of the site change after the time of inspection.
Applicant Signature: /,/'� ��``�-'�-� � Date:
If you would like to be on site during inspection,please check here: 1
Return application to: Department of Community Development,Planning Division
P.O. Box 186
Shelton, WA 98584
(360)427-9670
Please include a$205.00 check or money order payable to Mason County Treasurer
When completed,this form becomes part of the parcel file.
FOR OFFICE USE ONLY:Accepted by: c, �'�� Date:
MORE ON BACK SIDE
Revised: 01/18/06
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes, wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEOUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
44
t �
ttJ`� f (66 4—D c 1
o (�tvrlil
C
B �5
+j Pee 3 f-0
m �Z> +V
PtA4- 4
Departmental Review
(For Office Use Only)
Planning Department Findings:
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes, wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
Q/�-Qi
1
Se�l c��1
{�J (66 4--D t 15
�+tVI-14q
� 5
+jPe a
Scc 1'� f��oG,e �- S� �, ►�. 27--o
P&A`- 4
Departmental Review
(For Office Use Only)
Planning Department Findings:
' z'HOPU PLAT OF PORTIOIJ RFF[ R J
!SOUTHWEST QUART�-R' OF THE I IORTHEAST CCUA,R`TER
-�, :SECT lOU 34, TOWlJSNIP ZI N , RA,1,1GE 3 W , W.M.
M-SOLI COU QT Y , WASH I QGT0Q F EBRUA.RY, 19b0
375336 MICKELbou CO. P'D, /
SELLER: John L. Dupuis, et ux /
607 Grandview
Shelton, Wa 98584
� � I
Charles E. Needha
V r...
-7�
U ° o
Approved a!3
U ---------
bi
--------------------
.r;
U
W :
U v APPROXIMATE q_-
0 co
C RA1.113ERRY CREEK �
� P �
ro (D
ro
5.2+ ACRES
a�
S71co ° 24' 31"yJ
�5 Susan M. Handley
N 0 O N
. O N
1.1 a9*147'4A W g1�.30
?-O' EA.SEMEMT TO
MVC-KELbC)Q CO. RD.