HomeMy WebLinkAboutSPI2007-00045 - SPI Inspections - 5/9/2007 ON.STA MASON COUNTY
BPS C 'fr- DEPARTMENT OF COMMUNITY DEVELOPMENT
4 �t o r
° S N Planning Division
o Y 0 P O Box 279, Shelton,WA 98584
(360)427-9670
1864
Site Inspection
May 09, 2007
BRUCE HASKELL TO BE KEPT IN THE
261 E DARTMOOR RD. PARCEL FILE
SHELTON WA 98584
Case No.: SP12007-00045 P AJ; 3 Z( 3c/ 3 — cl003d
Parcel No.: 321341390030
Project Description: LOCATION OF WELL AND MH
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below you
will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands must
be included in your specific proposal; these setbacks are included as part of the comments listed
below.
This information is based on County and State regulations as they exist to date. These regulations
may change and may affect the requirements for development of the subject property.
Please contact me at(360) 427-9670, ext. 365 if you have questions.
Sincerely,
Allan Borden
Land Use Planner
Mason County Planning Department
5/9/2007 1 of 3 SP12007-00045
Site Inspection
5/9/2007 Case No.: SP12007-00045
Comments:
Pre-inspection for Bruce / Pat Haskell on Mar. 5, 2007:
The purpose of the pre-inspection was to evaluate issues related
to the construction of a single family residence on a 10.09 acre
parcel along Cranberry Creek. The parcel has much of the
evergreen and deciduous trees and ground cover throughout the
area. On this 220- to 250-foot deep lot, the upper third has 10
percent or less slope for 90 to 130 feet from west N - S property
line; the lower two-thirds area has a 25 to 30 percent downslope
to the creek, but no visible natural erosion or past slumping of
bank into the creek.
Development standards: The zone for the site is Rural Residential
5. Standard building setbacks for this zone are a 25 foot front
yard setback, and 20 foot side and rear yard setback (lot line
setbacks). An administrative variance may be requested to
reduce a setback distance from property lines, to as low as 5 feet
(side yard), if the size, shape, or features of the property constrain
development from the proper setbacks. This process requires
application and review at the time of the building permit submittal.
These setbacks are measured from structures 30 inches above
grade such as roof overhangs, balconies, stairs, decks, heat
pumps, and fuel tanks.
Landslide hazards: The upper northwest portion of the lot has a
10 percent slope, and the area of the former mobile home had
site modification done without permits in the past. With slopes
down to the creek in excess of 25 percent adjacent to or within
300 feet of a proposed project, a Geotechnical Assessment would
be needed to address slope stability and the other requirements
of the enclosed landslide hazard chapter 17.01 .100 section E. 4.
required by the Mason County Resource Ordinance. The report
must state that the hazards of the landslide area can be overcome
in such a manner as to prevent harm to property and public health
and safety, and must also assure the project will cause no
significant environmental impact.
A qualified geologist or engineer shall visit the subject parcel and
prepare a site analysis that is specific to your proposed site
development on the subject parcel, addressing grading, building
construction, and stormwater control. If any grading / excavation
is proposed in or near slopes a grading plan will be needed to
show any proposed topographical changes, cuts, retaining walls,
and proposed drainage. This analysis for site development would
be submitted and evaluated at the time of building permit
submittal.
5/9/2007 2 of 3 SP12007-00045
Site Inspection
5/9/2007 Case No.: SP12007-00045
Stream setbacks: The observed type 1 stream (Cranberry Creek)
flows from north to south along the east property line, and the
channel has established streamside vegetation. Stream buffers
and setbacks would be determined by the Mason County
Resource Ordinance Section 17.01 .110 Fish & Wildlife Habitat
Conservation Areas. These provisions establish buffer and
building setback standards for streams; for a type 1 stream there
is a 150-foot vegetation buffer and a 15-foot building setback, for
a total of 165 feet from the channel migration zone (CMZ) to a
proposed development. In accordance with the Resource
Ordinance, buffers are to be retained in their natural condition.
New residential development is not permitted within Fish and
Wildlife Habitat Conservation areas or its buffers, except as
approved through a variance request or reasonable use exception
public review processes.
Staff noted the 165-foot horizontal distance from the stream at
several points, and it appeared that a proposed building site and
septic location west of this stream in the higher terrace area (as
noted above) would meet this setback, if the site is no more than
60 to 70 feet from the west N - S property line. There would be no
need for a Resource Ordinance variance if development was
situated in this northwest area on the parcel. As stated above, all
development above 30 inches in height must be behind this
165-foot distance as shown on enclosed drawing.
General process: Future site development must include a site
plan, showing all setbacks from property lines, shoreline, and
existing improvements; this information will be needed for the
geologic assessment preparation and the building permit
application submittal.
Specific standards for future development contained in County
Codes may be found at the County website address
http-//www.co.mason.wa.us. If you have any questions please
feel free to call. Thank you.
5/9/2007 3 of 3 SP12007-00045
5(s SlP k a001 -00 v�J
AA to ^_per„ MASON COUNTY
PLANNING DEPT. PRE-INSPECTION APPLICATION
PLEASE PRINT $225.00 Fee Required 2121
•1. Owner: &0(e '-t �� Ha Applicant: S*Am 57
Site Address: 7o l E I kkelSriJ Pc , ShettDu Applicant Address:
Owner Address: -alpl 6, poi?--t elk- Dte., City: St Zip
City: SgE1-iol) St 6UA- Zip 'Ty5w Phone:(_) day
Phone:(34?o 4a4v - 3_� day
Phone: Sao Plan er:
Email Address: SMP S Comp.P an 2&1)) _T e of se
2. Parcel No. �j'OC�3 Water Body
- a
Parcel No. -
Legal Description: 1,0+, 4 04 SP A- 733 P%O 'M 3 S l,V
3. Purpose of Pre-Inspection : LO N LD N Of W e-A_( 4- M0(D 1 �e, ,W/n .
4. Use of building: R o-�,i A u(e
5. Do any of the following exist on or adjacent to property?: slope 09 saltwater lake river
pond wetland 00 seasonal runoff� other stream� seasonal creek
Directions to Site: "A) kake c ,
e w ow We
e2 L)xes e + G o
( egmy .
If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the original
application. Pre-inspection reports remain valid only until development changes occur in the vicinity which affect the lot
evaluated in this inspection,or the laws regulating development of the site change after the time of inspection.
Applicant Signature. e� - _ Date:
If you would like to be on site during inspection,please check he e:
Return application to: Department of Community Develop anning Division
P.O.Box 186 US bbd3�Shelton,WA 98584 M 9Zti►
(360)427-9670 1��Z
�
Please include a$�00 check or money order payable to Mason County Treasurer 83j
When completed,this form becomes part of the parcel file. Q3A I3038
FOR OFFICE USE ONLY: Accepted by: A/VN( Date: Du
MORE ON BACK SIDE
I:\PLANNINGTACTRE-INSPECTION Revised: 01/12/07
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes, wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
SIDP t V
1
—1 _ ry
�n4t�K _�s N
Departmental Review
(For Office Use Only)
Planning Department Findings: 4
�� ��
-�_
���
�`�
l �1
�'`
� 1 r�
+,...,�
'��'
5
`�
�,
�\
,�
,�
SHORT PLAT OF PORTIO►a 11kF.1 3,9 FF 639
375337 SW Y4 OF THE ME 1/4
5EC . '�)4 , T21U R 3W , W. M.
=� MA.50M COuUTY , WA5H1QG`TOM - MARCH, 14F�0
N
Charles E. Needham
Short Plat #___� 3
S 01'24'31 W 4 S7.70
....................
..................
\ Approved......-ezll
nN \ \ Planning Director
24�.94
501024'31"W / \
`-"�— M IC KEL50>1 CC), Rj7,
Li
r w 2 35.00 W — 154,90 — —
g ` Index
� 40' EASE.
00
x o 0 In CO s• \ \ 9ArnWMrsd
v $ 0 o O(r) j
\
235.00 �
3e 64
S 01' Z4' 31" W 620.84
Timberland Investors Exchange,
Inc .
70_ . . • ------•- 40' EASE. `�
l \
RED L 3
_�
'80 APR I y P1 2 : 20
i•c Jr�T OF
. IB�.►3 \
PLANNING DIRE.Clj
R.R. Moore, et ux
SELLER: John Dupuis , et ux R.A. Nienaber, et ux
607 Grandview 4
Shelton, Wa 98584
P 1 .. ♦ ".
AL
fj
' .♦ ♦ 1. � a �
r
• '
rr♦.
fit_ 9� + �t � ° .. b�= • ,
, o
•
8.
F ♦,. '*yid.
♦ �,, _. ,