Loading...
HomeMy WebLinkAboutBLD2007-00988 Final SFR - BLD Permit / Conditions - 1/24/2008 Insection Line 262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427(96700,ext7352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-00988 OWNER: DARRELL CHAMBERLIN RECEIVED: 6/6/2007 CONTRACTOR: HILINE HOMES LICENSE: HILINH*981 BT EXP: 2/10/2008 ISSUED: 6/27/2007 SITE ADDRESS: 2390 E MCEWAN PRAIRIE RD SHELTON EXPIRES: 12/27/2007 PARCEL NUMBER: 321330090023 LEGAL DESCRIPTION: TR 2 OF N1/2 LOT: 3 OF SP#2295#564084 PROJECT DESCRIPTION: DIRECTIONS TO SITE: New SFR McEwan Prairie Rd. for 1/4 mile past RR tracts. Stock Plan #2003-0002 General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: 4 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R3 Lot Size: Deck: 228 Type of Work: NEW Fire Dist.: 5 No.of Stories: 2 Occ. Load: Building:2,776 Garage-Attached 624 Valuation: Building Height: 24 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: N 135.0 Ft. Shoreline: Ft. Water Body: SEPA?: No Model: Width: Ft. Rear: S 124.0 Ft. Slope: Ft. Shoreline Desi Side 1: E 156.0 Ft. 9•: Not Applicable Year: Serial No.: Side 2: W 50.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KKK 6/6/2007 $337.63 S22007000 Hosebibs 2 Furnace<100K 1 Planning Review Fee KKK 6/6/2007 $170.00 S22007000 Kitchen Sink 1 Ventilation Fan 4 Address Fee BLJ 6/7/2007 $154.00 §12007000 Lavatories 5 Heat Pump 1 EH Plan Review TW 6/18/2007 $75.00 512007000 Showers 1 Dryer Vent 1 Building State Fee MAL 6/26/2007 $4.50 512007000 Water Closets (Toilets) 3 Building Permit Fee MAL 6/26/2007 $1,688.15 S12007000 Water Heaters 1 Mechanical Fee MAL 6/26/2007 $84.20 512007000 Bath Tubs 2 Mechanical Base Fee MAL 6/26/2007 $25.30 S12007000 Clothes Washer 1 Plumbing Fee MAL 6/26/2007 $121.00 S12007000 Plumbing Base Fee MAL 6/26/2007 $22.00 S12007000 Total $2,681.78 BLD2007-00988 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2007-00988 CONDITIONS FOR BLD2007-00988 1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X '`' 2) This parcel is located in a smoke management zone. Please contact a fire warden at (360)427-9670 ext. 459 for further information. X - 3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-547-0982. The person signing this condition is either the homeowner, agent for the owner registered P e or a contractor according 9 9 9 to WA state law. 6 4) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason Count Fire Marshal q a standards for Fire Apparatus Access Y pp Roads up to the point where such roads-connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 6) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. - X ,/-4'- 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 8) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X `.-- BLD2007-00988 Please referto the following pages for conditions of this permit. 2 of 4 I 9) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 10) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X '>:`._ E 11) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X ;'� 12) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X 13) Per 2003 IRC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X :t1 14) Stock Plan Identification number: This project is approved subject to the provisions identified the Mason County Stock Plan Policy. The site plan approved by the Planning Department, original building plans, and all attachments approved by the Mason County Building Department shall be available for the Mason County Building Inspector-at each required inspection. X 4, 15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 16) Installation of heating equipment in single family residences shall meet the requirement of the current WSEC. The furnace to be installed shall not exceed 200% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher or rated 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with manufacturers installation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X 17) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or-regulation, must be reviewed and approved by Mason County prior to construction. X BLD2007-00988 Please referto the following pages for conditions of this permit. 3 of 4 1,8) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector,shall be made prior to requesting additional inspections. X 19) All property lines shall be clearly identified at the time of foundation inspection. X 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors,.,ap_O flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 23) Retaining walls needed to support a surcharge5uph as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall.X __._ 24) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan' .,ensure these structures are shown and meet the setback conditions listed. X f This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspectio . OWNER OR AGENT: - DATE: BLD2007-00988 Please referto the following pages for conditions of this permit. 4 of 4 r co o CONCRETE MECHANICA MANUFACTURED HOME 6_ Date 9/a y o 7 By */Lc 3 oV Footings!Setbacks 7 Ribbons Geis Piping o Interior Date By I Interior-Date By bate By rWrl co Exterior Date By lJ Exterior-Date B Sat-up X Point Load J Isolated Footings INSULATION Date By Z BG t SLAB INSULATION Date By Data By FIRE DEPARTMENT D Foundation Is Floors _ Date By X bate ;�10� By �� m Date'7 3 i 0' ByDECKS FRA NG Wars Date By r r Date c y By 14V Data j© y ," By 1-0"' PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic C fv-j4." L� Date Z ! C) ByB"— Type: Date By Date 8y DWIV DRYWALL_ Type: �� Int Brace W I Date By W Dacejamq b2 B Date By 67 r FINAL INSPECTION 0 v Water Line J,, Fire Seperation tV Date 9/Z�/� By Data By Data I, Z�{ L,tj By /J V.'' O m ` Pass or Request Inspect. CD Type of Insp. Fail Datq Date Done By Comments 00 CD co �. 3 0-7 � o►� `i a.SS +7 -7t-5�0 07 CD 0 8 a 0L::t:4�W,eo A,L Y c fJ CDAss q K,d4-M � Celli �/ cs.5 !6 8 07 f 9 07 cr4 l `mass 01 ( L5 .lam IG W J7 /L /Z h 7 T% 5*� Ae- 0 % PLANNING: J r ALL SETBACKS ARE MEASURED f I FROM THE FURTHEST �ty� PROJECTION OF THE BUILDING _ ,� �r 6A PL G i r I i , T w uj l (Clio Plot Map Drawn To Meet Y Q5 A -lil-ine Homes Specifications. f Any Revisions To Be Made :< By The Home Owner. ; APP LOVED MASON COLIN BCD PL _ I `yFA 5 � ANNING , ` D6A SITE PLAN REQUI:�E7 TO BE ON SITE CHANGES SUC -CT TO APPROVAL ! !3y MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/VIAQ Compliance Application Owner: ffl bsA 11, Telephone:4427- a Parcel#: Type of project ( New Residence ( )Addition ( ) Remodel Total Sq. Ft. 1"Floor: 2 nd floor: Heated Basement: of heated area:: Heating System Type: O Electric wall heater O Electric Central Furnace O LPG Furnace * Heat Pump with electric furnace O Heat pump with gas furnace O Boiler, specify fuel type: O Other: Specify Glazing 0 Prescriptive Option see reverse side circle one: 1 II IV Percentage: Compliance Method O Component Performance , Chapter 5— Calculation worksheets required Check one:: O Systems analysis, Chapter 4 O Whole House Ventilation system O Whole House Ventilation using a Heat Ventilation using exhaust fans&window or wall fresh air System vents (VIAQ 303.4.1) Recovery Ventilation System (VIAQ 303.4.4) Check one O Whole House Ventilation Integrated O Whole House Ventilation using an inline with a Forced Air System (VIAQ 303.4.2) supply fan. (VIAQ 303.4.3) Window & Door Schedule (If needed, attach an additional sheet) Total Manufacturer Room/location U-Factor Size Quantity Square Feet Windows: Windows: Total Sq. ft. Doors: Doors: Total Sq. Ft Total window and door area Total window&door area /(divided by)total sq.ft of heated area = %of glazing r MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON(360) 427-9670 BELFAIR(360)275-4467 Elma (360)482-5269 FAx: (360) 427-7798 WEB SITE: www.co.mason.wa.us P.O. Box 186, SHELTON 98584 2004 Washington State Energy Code (WSEC) 2003 Ventilation and Indoor Air Quality Code (VIAQ) effective July 1, 2004 Code Compliance Application Form The following information will be required for the WSEC and VIAQ plan review: 1. Complete the Washington State Energy Code/Ventilation and Indoor Air Quality Code (WS EC/V IAQ)a ppl i cation located on the reverse side. 2. Complete the window and door schedule on the reverse side. Include all windows, skylights, sliding glass doors, french doors and any door that is more than 50% glass. Use rough opening dimensions of the windows and doors. Information about the U-factor of the window will also help to expedite the energy code review. If you are complying with the WSEC by prescriptive path and are using the area weighted average method you must include your calculations. 3. On your building plans note the location and fuel type of water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of insulation proposed for walls, floors, ceilings and slabs, 4. Questions? Call Mason County Community Development at (360) 427-9670 ext. 352. Additional WSEC and VIAQ compliance information is available on the internet at: http://www.energy.wsu.edu/code/ Prescriptive Requirements 0,1for Group R Occupancy Climate Zone 1, Table 6-1 Glazing Glazing U-factor Door Wall Wall Wall Area%of U- Vaulted Above interior° exterior Slab' Option Floor vertical Overhead" Factor9 Ceiling Ceiling3 Grade below 4 Below Floors on '° 2 'Z grade Grade Grade I 12% .35 .58 .20 R-38 R-30 R-15 R-15 R-10 R-30 R-10 II* 15%* .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 IV Unlimited Single Family Res .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 (R-3)Only *Reference Case/Call(360)427-9670 ext.352 for footnote information. Log&solid timber wall with a min.avg.thickness of 3.5"are exempt from the above grade wall insulation requirements. Window Schedule HiL � for 2776 plan H O M E S Hiline Homes of Belfair Manufacturer: Milgard Windows Inc. Model: Classic Series Type: Vinyl U-Value = .36 Windows Quantity Size/Handing Glazing area Total S . Ft. Location width x height 1 6'0 x 5'0 30 30 Living Room 1 6'0 x 5'0 30 30 Living Room 1 4'0 x 4'0 16 16 Bathroom *1 6'0 x 4'0 24 24 Master Bed 1 4'0 x 3'6 14 14 Kitchen 1 TO x TO 9 9 utility 1 6'0 x 5'0 30 30 Dining Room 1 2'0 x 5'0 10 10 Entry 3 6'0 x 4'0 24 72 Upstairs Rooms 1 TO x TO 6 6 Upstairs Bath 2 6'0 x 4'0 24 48 Upstairs Rooms 1 4'0 x 4'0 16 16 Stair Case Slid. Glass Doors 1 6'0 x 6'10" sgd 41 41 Country Kitchen Total glazing area 346 sq. ft. 346 - 2776 = .124 X 100 = 12% Glazing Area Conditioned floor Area Glazing Percentage *If a sliding glass door option was chosen, switch the appropriate window w/the sliding glass door and use the calculation below. 1 6'0 x 6'10"sgd 41 41 Appropriate Room 363 - 2776 = .130 X 100 = 13% Glazing Area _ Conditioned floor Area Glazing Percentage All other doors,windows&skylights do not need to be calculated do to the fact they meet all minimum requirements. MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 eLL Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLI NT INFORMATIOJ�I, CONTRACTOR IN O MATION Owner / ►�`/ Company Name Mai4n Addres Mailing Ad ress `- Ci tate �_ Zip Code City State L��. Zip Code Phon - L� Other Ph_36.-[)'7f2_5`)_32.2- Phone,1� z `11 Other Ph. Lien/Title r Contractor Reg. # f- Ex -r C P E mail address r C.° ) E Mail Address Drivers Lic. # DOB Drivers Lic.# DOB_ SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Conne t o Water System Name of Water System Well_ A Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No ' _- Fire District -, Legal Description Site Address (Please include street name, street,number and city r'f Directions to sit C c_, Will timber be cut and sold in parcel pre aration? Yes No Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs ] 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Yes of TYPE OF JOB - New (_Add Alt Repair Other PRIMARY RESIDENCE N SEASONAL ❑ Use of Building Describe Work No. of Bedrooms_ No. of Bathrooms,. > Square Footage- 1 st Floor H"SH 2nd Floor 3rd Floor Basement Deck Covered Decker` ° Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED O E INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X " 'Orc Ir Date: Owner/Owners Representative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: ' .r' Date Co-SaC DEPARTMENTAL REVIEW APPRIQVED DENIED NOTES Building Department MAL- Planning Department = cc.� 57 Environmental Health Department .? Public Works Department Fire Marshal -:5 ' ' FEES Building Permit Fee I Site Inspection Plan Review Fee 4ci EH Review Fee Plu_mbina & Base Fee 'ZZ— Planninq Review Fee Mechanical & Base fee r- 3t Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ 1 TOTAL FEES