Loading...
HomeMy WebLinkAboutBLD2022-00751 MFG Home - BLD Inspections - 12/13/2024 615 W.Alder St.Bldg 8,SHELTON,WA 98584 MASON COUNTY SHELTON:360-427-9670,EXT 352 COMMUNITY SERVICES BELFAIR:360-2754467,EXT 352 Building,Planning,6nviru�menWl Ht 11K Cammunity Heah}, _ ✓ ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2022-00751 Date Issued 10/09/2023 Issued By Project INSTALL NEW MFG HOME Site Address 605 E Inspiration Way Applicant EMPIRE HOME CONSTRUCTION LLC Contractor Contractor Phone Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type MANUFACTURED HOME Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks /p /I Z, Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home 10AAS Concrete Foot/Runners Final L 'r-a011 w`Other , „ 34sc- 3/13 I2.4 -1 A, ( 5-q-2,q J-Q- C,�_4+4 , s4A-Y1�- r MASON COUNTY 360-427-9670 Shelton ext.352 467 Belfair ext.352 t COMMUNITY DEVELOPMENT 360-275 360-482 5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg. 8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIOWINSPECTION REPORT PERMIT/CASE NUMBER: &17202 2—DD'1 5--I ADDRESS/LOCATION: DINGS: v� S d5 74.1( Q� / 0 -lr4 >� v ��S�cG-�liVrS. 3 C 4-i ,,t -e `cs5�vr �/ iN 17r-P-1t-' 'Ot-,aCvvt et �— G t �� iN �in.�..a �p.Lt„ ►�•S 3u.., �ws.ol a„d. �s n�o�J 2" G,�,�.,dtid �Sc. ��ro►�I A tl- tots 4.1 5 t4-0 I-?,w be_ + Tk Items listed above must be corrected to lain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. all for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. ❑ OK to Date: 3'ZI-z Please contact our office regarding possible Department: structural damage incurred by recent Inspector: _�— "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 Belfair ext.352 ' COMMUNITY DEVELOPMENT 360-275-4467 360-482 5269 Elma ext.352 Building,Planning,Fire Marshal 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: B LD Zo Z z - 00?S1 ADDRESS/LOCATION: (tGS i✓ . 1ti• Q,yu -try w,%,, 51..Ir40n FINDINGS: fnuk w "61 1ti.s�+,� 4.,..1 3ti►s,,lk1 n lc..^y-ziLa ►t Se .�o ,ill pLSs One` A" :t RGL..L_.B Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. OK to a� e sl,, wal�� L,1,, %nslrjj d *r& Soo A o JI- Date: Jj I 1 2y ❑ Please contact our office regarding possible Department: &Z structural damage incurred by recent Inspector: J'N "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 INSPECTION RESULTS Page MASON COUNTY INSPECTION of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584 Permit Assistance tenter,Budding,Planan;ng (360)427-9670 ext. 352 Application# BLD2022-00751 Application Type MANUFACTURED HOME Owner EMPIRE HOME CONSTRUCTION LLC Parcel# 120303190083 Site Address 605 E Inspiration Way Shelton, WA 98584 IS k �...a`t ...�. .. amuA�..., mCe�.,.. ...: ,n.... :_Mww;�w 11-4-24-JQ Joshua Spoke to Allan Kirk 11/4/24 7:15 AM not ready for final inspection Quarders BLD-FINAL INSPECTION 11/04/2024 FAIL septic is not closed please contact EH and have septic closed before final inspection THIS IS NOT A COMPLETE INSPECTION CALL FOR INSPECTION WHEN READY T ti Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2022-00751 MANUFACTURED HOME PROJECT DESCRIPTION: INSTALL NEW MFG HOME ISSUED: 10/09/2023 SITE ADDRESS: 605 E INSPIRATION WAY SHELTON EXPIRES: 04/06/2024 PARCEL: 120303190083 APPLICANT: EMPIRE HOME CONSTRUCTION LLC OWNER: EMPIRE HOME CONSTRUCTION LLC P O BOX 241 P O BOX 241 KELSO,WA 98626 KELSO,WA 98626 1.360.751.8062 FEES: Paid Due Modular/Manufactured Home $275.00 $0.00 Fee-2nd half collected at ready to issue Technology Surcharge $12.60 $0.00 Building Plan Review/Change of $130.00 $0.00 Use-Onsite Sewage State Fee-Residential $6.50 $0.00 Planning Review Fee $240.00 $0.00 Modular/Manufactured Home $275.00 $0.00 Fee- 1 st half collected at submittal Building Plan Review Revisions $80.00 $0.00 Totals : $1,019.10 $0.00 REQUIRED INSPECTIONS Setback Inspection Connection has been verified by Health or Utilities Footing Inspection BLD-Final Inspection Set-Up Inspection CONDITIONS Printed by:Cassidy Perkins on:10/09/2023 11:22 AM Page 1 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-00751 * The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * REQUIRED INSPECTIONS (Footing Inspection-prior to pour(set-up manual must be on-site), Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWN ER/CONTRACTOR(indicate which) * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (NCSBCS/ANSI A225.1). * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Cassidy Perkins on:10/09/2023 11:22 AM Page 2 of 5 Id Adir Mason County f Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-00751 * Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three feet of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. Certification number and signature of the certified installer responsible for each major part of the installation.WAC365-210 * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton.The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M. Support configuration shall be clearly marked in the installation instructions. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. Printed by:Cassidy Perkins on:10/09/2023 11:22 AM Page 3 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-00751 * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null& void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indicated on the plot plan. * All property lines shall be clearly identified at the time of foundation inspection. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * Setbacks are twenty-five feet from front, and twenty feet from sides and rear. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s)requires 5ft setback from all footing/foundations. C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. * The bottom of all footings must be a min. 12" below existing grade. Any gravel used to level the site must be compacted to 95%. Mason County Building Department requires a site inspection prior to placing the home to ensure the minimum requirements have been achieved. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any ny other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: Printed by:Cassidy Perkins on:10/09/2023 11:22 AM Page 4 of 5 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-00751 Printed by:Cassidy Perkins on:10/09/2023 11:22 AM Page 5 of 5 c.l�c�O�`re New Mai" &6e( (Z630—3(— EEGx 2(G MIX'MEUAMCUMM WAS"*MH5MCMES REVIEWED FOR , .. CODE COMPLIANCE MASON COUNTY .. .� ?? ,„ BUILDING DEPARTMENT ftM M b qpmWa e Ito W&W+shy rT . "Imade Y Nwmtor of p � REVISED 'r'" '�'' .� �E� DATE 7-•z 5=Z 3 foofiv-s mod Mc- ww owk ovrest' ' ter' 0 fmli ry m m • p p p Epp �/ s b N N �O2yy (b��f I �WOq b 1 � N V V �~Y •,��]� �»�' ,"U,♦�� .ry ♦1 N m N{ m NI N V i hj m b b NIb NINON . C M ry nib N b N N • V yi�� 0II�� N N I N (NJ 'D m 7 m � 41 'f M1 f(((ff V N W m { p m .a N N� m N m v( b) a � � N m� N i h � M m ,� v ,,,�'� \O.•,(��` , m C nW V spy fp i yf OV i1i t`M p p p �� � tS� �,� •C'�(�y'.*1•` m N f O I N S T N G. ONO F OD I N F „ N O yO I / • •��.•` '*��i+ \��. � M d� M M b) m p pp ,-1 d h NI!` .-I m b ei � �','~••,�����1�1�,��`,t W L (V eN1 lV i b m N n n N 0ptp�� N yf p d b ry 1ST ty� O o0 8Q ei p O H 6 Q g 2 10 Op� N fD 0 N I d N a F f`! eMd m N M Q N ee1 M N ri Ymf W r O- �prplf fpp yO N OQ tpp �VNpf ry ;Qj fume W O Ow f1N��.' pN f/ml s � p Qftl pp Qpp p pp pp q pp � pp C `. a [WO VO f� off CJ fry f�f �.f Qf O \ m p yC�111 m OJ N pf N jS5 I I I g N N N N V e o o $ ,O-{ OO ' i �I of o x o j n o Q m o d rnn o v N m N N r II d n n rv� m� °a N •+ an d I d n N fo m a � O N e1 O O ry N O N O m ti O O N O N O M s C N m N b d N I N d N I a d '1 rthl �0 N N Ol T n N P W J a LL N O O N 0 0 � n N N tlNt!11 fdfVV fVO. a0 fO �Ny I O O-N ebi �-f N N E N m t�l fN0 R� m $ N H M vl� ry E V W aNq ON M NN N Al M Z N .1 m N d N 2N`2 fn m M1 Opp 1pD p q ry p p F O Q N I� N n a e r1 N O q n ebi m,1 mW D e O q N N ti m N ti rl N N N m N N N V f m f i ry I Ol m 9 LLvi A LLI LL A LL 5 LL N ¢ LL N LL b 'v sr b` u io 5o m m o a a e io io b 00 k k b i « « « « « b qs « « « « « « « 6 > > > 4 A A A A A 0 N M > M..^.......A.....A.A A A ^ t : '• 1 M-�'. Ph. 951-6744011 Fax 95'1�674-572U wvvw.SedcpPier,com a sedeopier@verizon.net L _ ,_ � 3MO Mission trail 1�(iiciamar, CA 92595 Base Pad 'I l6x1 .201 l Mode #.BP1616 930 i �., W&Pier Loa0s PSF ;201 Soil Capacity(psfi Design Load(lb) �ODQ 1 78 . 3000 5333 Can be used,with concrete blocks or steel piers. j 20 rF The pier is to be either a single open cell concrete block confl<�.- griraiion,a double stacked open cell a conbrete block application,or a steel pier aplicallon (to be consistent with the RADCO Listing#1355, section 5,d) 1 Secure metal piers to pad with:(CA only) 1 4-41.4 x 1-11Z screws or 4-41`4 x 1=.11t screws 16.080 Label Molded in Pad 1) Model#BPI 616 7 2) Smooth Side Down D Q D 3) Installer responsible for determining soil bearing toads acid capacities 4) Manufactured by J. Sedco Pier Inc. , a7�1'. 0 .dro PNr-lne. 5) O" * •,�. Listing 41355 &3 1 Q0%n Preln.urn : Psi i DE Install per RADCO listing 9#1355 or manufacturer's w, Grade Composites "�"— *_U._S�A*_;i published installation instructions. ENGINEER APPROVAL - STATE APPROVAL C,'Ruz D Digitally signed WAsyi�gly� by Lorenzo Cruz� y y y Dimalanta Date: POIGIsBf ��G�� 2019-10-18 16: siONA� 02:21 www.sedeopler.com 951.674.4011 l pfi. " 1`6744011 " Fax 951.674-55720 1 WWW.SedcoPier.com •sedcapier@verizon.etet t- _ �_. �. =.i '33320 Mas-mlOn 'Frail Wildomm, CA 92595 flux Pier Leads PSF q o Soil Capacity(psfi) Dasbn Load Qb) 10QQ 2377 1SpD 3;;65 �3U �11 -- 2f1QQ 4753 3000 7130 C i.21y o- Can be used"tilh wncreta blocks or steel piers \ i8,375 tL aW ll OT'led in Pad '0 Model#BPI 2) Smooth Side Down 0 3) Installer responsible f!ar deter,nining 7J.5d� (/ soil bea;ingloads and capacities 4) Manuia tUrOd by'Sedco Pier Inc. h PIE s "`dtnPhYLie M PremiumM.ADZ USA* Listing#i355 A. q !J 141773 � 7 It SSf�NAL V;�kCs cm Ph- 951-674-4011 Fax 951-674-5720 vr►.'.w1 Sedc©P1er-corny •sedcapier verizerp. e Mi$sn0"TraH Wildomar, A 92595 'k Bass Pad 24x24xi y;a _ Max Pler Lozft VSF SDII Capacity(p!5 j 'befsiven Load(lb) D1 flQD 41000 1500 sago 2000 8�if0 z_2a 34t}0 9200t1 Can be usad v,M concrsts blacks of steal piers T Label Molded in Nd I) Model#BP2424 ?_) Smoott3 Side pavan 3) installer responsible for detei"ining q soil bearing loads and capacities 4) Manufactured by Sedco Pier Inc. Ypl JjJ� I LJ�p• i odca PFvDx 4 T\ O radQ 5) Li o bos33es SAri�� Q ' -a drig41355 Q nUSla ......... E N G I N APPROVAL STA :, APPROVAL A 14116 rpNAL E�G1t�' . PACIFIC CONSULTING ENGINEERS 2150 Bell Ave.Suite 145•Sacramento,CA858SB PH.(sla)56"02a M7.Sadc0Pjer-c0m a 951.674.4011 RaVE%( 55TYP24563AH MY GIRL 2,41 JUL 21 2023 615�\N. Alder Street 6• nYl• lo'—r 16'-1D)4' } -r-,o• �1+'-5ki' it O O �ER UTIUTY o• m 0® DRYEA wAslax J 190 EQ.PT. DI all NMG FAMILY ROOM SWOF 88 SQ 163 SQ.FT. AT P.w7RT iFJBd mN,D 15 flEFTA � j i PINIRT BP-4 8• 6' QIO WId1 OOgt .•, _ BP-2 ------------ -_-______-_- n o CY ® 15-9 1/7 31'-3, -' 4'-10Yj BEDROOM I ® UVING ROOM BEDROOM 3 A H BEDROOM 2 r 141 EQ.f7. 202 SQ FT. n s n a' O 90 SQ.FT. 1IG 90 SQ.FT. ® A N8/91�MR� EGRESS ® EGRESS 6•�3. -12'-6• 3�•i� 17'17•.___��_�I 3y2 -3•-��4.-11•-�-8.-3��'�'6- TOTAL WINDOW R.O. SQUARE FOOTAGE: 176.35 CMH Manufacturing West Inca Marlette R NEW PRODUCT FOR 20 3 04 03 S T �p r�V. A K\homes\2022\TEMP0\PURPLE MIN MY GIRL\55TMP24563M.dwg,7/12J2023 I VOQ46 AM,Le poldM RECEIVED M'FAG=f jU 2 120 23 n" PER Wa 1CM ma maw) Alder street DELETEWHEN NOT ORDERED ® �J .4-IM MMY)*0 ACCW ="am" FRONT ENDWALL ELEVATION REAR ENDWALL ELEVATION 111111111 III Bull 1111 11111111111111111 11111 IN ILI U-LH It r000 FRONT SK)EWALL ELEVATION FIE1111111 111111 Jill Jill I�11111 Ifl IiIH1 111111 Blill Hull HHUEaffi it 111111[]Hit UL111111111111,11 111111 mmoncturilm WMI%Irm Albany Division-Plant#972 (7�2"5 S.W. PACIFIC BLVD. FB - ALBAW.OR 97321 Phone(541)926-5631 I 1 m`nna Fox(566)491-6547 Iff" EXTERIOR ELEVATION REAR mEwALL ELEVATION a."".r Go.' 6* WALLS TEMPO TM-24M-3A "Tt 1.326 2-A RECEIVED JUL 21 2023 OLPa 615 W. Alder Street LEGEND 5•-r Mr-r �'a' 6'-7' 6'-7' SW -SHEAR WAIL -15 AMP W NT D 3 73 W W W ® O R RECEPTACLE INFO PFR ♦ -20 FIB /a91R b b bSh, m of 7 7 E/y�9e9WNDOW R RECEPTACLE 7C.1 UTLFTY •LA 0' J _—_—_ v DOOR SCIIF➢. S _WALL SWITCH \7t B FAMILY ROOM 3 0 ! 164 9fi.FT. ) �W -WATER NLFf -HEAT TAPE P.BATH r�_ /•"� •"`. A -l�fT Hr HE RECEPTACLE 7 ® I 9 W IQTfOETI / I �D Sa IIIM�` i 3 O i 7 �G -CAS NIET ST7SIAX mU� ',I 7 IN/fm I S SEWER OURFf CO{Wf 3pD 3 QF SDIIW W/FUEL '� 61AF _ -\ll Yf FOJHG APPL `' CARBACE DISPOSAL 0 I /- 6D,G0 7r• [~', -ORYEA VENT �GD "YIIOC BM b �� m _ -EGRESS WINDOW p -�RECEPTACLE -- -- ----_—_-- -- E (15 OR 20 AMP) OPTION aRartGFI RECEPTACLE NFO.PER DING.lA 'y2 IM m.vy w ,r 3n•m ni�w 9�i•4 wr - PER LIGHT FA REQUIREMENTS O -DOiNM FAN 4'.107 ADJ. s uv�E 5 4 4 -- A -FLOORH dbn e� ' }I °+e4a "db' .4 a 4 ndb a REGISTER ua e0 �SIGTRIL DOWFION 78•YMULN REOLME ]4 74 JI is �\ OFF. // ` ,, 4 OCLEARANC THERMOST Lo PER CODE FUORES.9R S g UGKF *242 t{f(•r /�• ,' I L74 •\AI OPL trlb y.[ I I 4 B -� m -J-BO% {� _ XiTT R3AARY B.C..B.C.. BEDFROOM♦3 4 uBEDROW■2 w•+ COMBO FAN 0 140 52 FT. w"A.PT. w 54,FT. 4 4 4 uY: m 7 WE I 5 3 W W fff Model TM-2456-3A My Girl Mninum.tul 5p.'m 16' B.Wdlh• 142' O0u11e Wide No 01Isq Bo[ B.Lelglh= 56 E. 99.5'10'MIN IBEAM No Claalory No Skylight, No OHp,m'Donner No Penh. No Sunken Floor Jas1 Sae• AR hf 2[I Up 9Ma3' No Parapel Rod Verson R13.2; NSnd Zm lEYMaN Rnur (W' 159a 1A'M ma' Ol rxh AWnx40 Manufacturing West,Ina ¢1197 pM 0md4:7M SPF 1137ep RM I Albany Did9icn-Planf 1972 Dla hp m0lmtmcmn: 1A.- E>tH.ilk.BwI ..Merl _ 2.5 S.W. PACIFIC BLVD. Sheanrsll nv Her Le n I FLf 0r.bn1[ Nges ALBANY,OR 97321 A O' W. 225 3 M LL7W Ph4Hla(541)926-8631 B o' II' 225 2 7n Fax(866)491-6847 C 56' 95. 225 1 2 1 2J1 DRAWING TITL,ELECTRICAL SCHEMATIC & APPROVAL FLOOR PLAN uclnAA onAronc sx 9DEWMAA 4•OR 1' 6• WALLS 1—m Napa HD STRUCTURAL NOTES RMAL HEAT NOTES GENERAL NOTES I TOM M07M TEMPO TM-2456-3A t ROOF DESIGV LOAD:20 PSF.30 P.S.F.AND 40 P.S.F. 4•INTERIOR BEARING WALLS PER 9104 CAPACITY OF All COOIdlG SINPLY OUCT SYSTEN R43C TER SPLIT: WL TOTAL B.T. L FLOOR PUN MAY BE CONSTRUCTED IN SIDE TO SIDE REVERSE 1.AN1'ABOVE SYMBOL R 1�326 DATE - 2 NA3AIN RIDGE BEAM SPAN:FOR 20.30.40 PSF. S 14 U3 AT 20 P.SF;I21 2.3AT 30.4-pSF. THERMAL 701E 1 THERy Zoe R TO THAT SHOWN WY BE SHOWN Dt4® ROOFS SHALL BE PER STRUCiDWG.91.03.1 OTI 2 IT OR 9B'NOAaAL SMEWAU HEIGHT MESS NOTED OTHERWISE I INDE"T R AS OPT. 19 214 AT 30 1 30 PSF:IN 214 AT 40 PAY. NEAT LOSS NUN M0. - WK GLATAICs - TEAT LOSS RI1N N0.=YAL GLA'G. - ].CERT.LABlFS,SERIAL ATLIEAS.ETL.TO BE PflOCATEO PER 2 BRNIaI CNMT Na 1-A3 3.ROOF PRCH 4:U OR LESS,MESS NOTED OTHERWISE AT LON D AT ALL PASSAGE DOOR OPENNGS _ _ _ AT LOHGRVT AL CENTERLINE WALL HEAT LOSS RlM N0. UA.GIA— NEAT LOSS RIM N0._ MAK GLA CODE REBUS.ERIA. PER E1FC.d-43