Loading...
HomeMy WebLinkAboutBLD2005-00177 Cancelled Furnace and HP - BLD Permit / Conditions - 2/4/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 MECHANICAL PERMIT BLD2005-00177 OWNER: TERRY, WELSH RECEIVED: 2/4/2005 CONTRACTOR: OLYMPIC HEATING & COOLING 360-426-9945 LICENSE: OLYMPHC986BA EXP: 1/1/200 ISSUED: 2/4/2005 SITE ADDRESS: 70 E STONEBRIAR PL SHELTON EXPIRES: 8/4/2005 PARCEL NUMBER: 321323290092 LEGAL DESCRIPTION: TR 2-13 OF SW NW LOT: 2 SP#2263 70 E STONEBRIAR PL SHELTON PROJECT DESCRIPTION: DIRECTIONS TO SITE: FURNACE, HEATPUMP N ON BROCKDALE RIGHT ON JENSON, L TO STONEBRIAR PL, HOUSE ON R General Information Mechanical Fixtures FEES Type of Use: PUB Insp. Area: Type Oty. Type By Date Amount Receipt Type of Work: MEC Fire Dist.: Furnace<100K 1 Mechanical Fee KS 2/4/2005 $25.45 S12005 Heat Pump 1 Mechanical Base Fee KS 2/4/2005 S23.50 S12005 Total $48.95 BLD2005-00177 Please referto the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR B LD2005-00177 CONDITIONS FOR BLD2005-00177 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X J 2) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X ,`T 3) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers)shall obtain combustion air from outside in accordance with the international codes. x YI-k� 4) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason Count Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 9,� 5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with X Mason Count;ronances and building regulations. 6) Installation of heating equipment in single family residences shall meet the requirement of the current WSEC. The furnace to be installed shall not exceed 200% of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher or rated 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with manufacturers installation instructions. Duct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X BLD2005-00177 Please referto the following pages for conditions of this permit. 2 of 3 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and struct re for review and inspection. OWN ER 0D AGENT: _ DATE: BLD2005-00177 Please referto the following pages for conditions of this permit. 3 of 3 MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedar- P.O. Box 186, Shelton,WA 98584 Shelton (360) 427-9670-Belfair(360) 275-4467- Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANLWFORMATIO CONTRACTOR INFORMATION Owner Company Name' Mailina Addres Mailing,Address City tate��`Zip Coded?`�Q''y City �Ily l 1Uv'1 f-Stat—P'Phone Other e Phone - Other Ph. " Lien/Title Holder�L L Contractor Reg. Exp. E mail address E Mail Address `► Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digi�Par I No. Fire District Legal Description 0 U S Site Address (Please include street naTe, street number and city) Directions to site NP-J•i" n L l4iv<1_,Ati Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPQ Natural Gas_ Heat Pump Toilets Type of Unit No. of Units Fes Bathroom Sink Furnace Bath Tubs Heatpumps i Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other 37 Base Fee Base Fee SU TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provid s accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PR�QF CO INUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X ` ,f Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group—Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES