HomeMy WebLinkAboutBLD95-01709 Final SFR - BLD Permit / Conditions - 9/9/1996 II T I
- MASON ,OUN I T
Mason County Bldg. III 426 W. Cedar
i P.O. Box 186 Shelton, Washington 98584
00 —
B U I L- ID I N P E R M I T FOR INSPECTIONS CALL 427-9670
BETWEEN 5pm AND 8am 427-7262
BLD95-1709 PARCEL :321323290112 PLAT : DIV :? BLK :? LOT : ?
JOB ADDRESS : E 121 STONEBRIAR PL SHELTON
OWNER : VERMILLION CONSTRUCTION 791 -5196
CONTRACTOR : MARK
LEGAL : TR 11-8 OF SO NW,NILY OF CO RII TR 2 OF SP #2267
CLASS OF WORK NEW BEDR : 3 BATH : 3 TYPE AMOUNT BY DATE RECEIPT I T Y P E AMOUNT BY DATE RECEIPTI
TYPE OF USE . . . . :SF STORIES . . . . . . . :2
OCCUP . GROUP . . . :? BLDG . HE I G H T . . : 0 .Oft IPRMT $ 396.00 TDH 02116196 41274 jEHCP $ 10.00 TDN 02116196 41274 I
TYPE OF CONST . . :? FIREPLACES . . . . : 0 P L M $ 51 .00 TDH 02116/96 41274 i
OCCUP . LOAD . . . . : 0 WOODSTOVES . . . . : 0 MCH $ 39,00 TDH 02116196 41274
DWELL .UNITS . . . . : 0 PARKING SPACES : 0 F I R P $ 25.00 TDH 02/16196 41274 I i
INSPECTION AREA : 3 SHORELINE? . . . . :N S T F E $ 4.50 TDH 02116196 41274 TOTAL: 525.50 VAL ILL AT10N: 80376
SETBACKS-------------- TOILETS . . . . . . . . . . : 3 FUEL TYPES---------- BOILERS/COMP---- MOBILE HOME--
FRONT . . . 0 .Oft BATH BASINS . . . . . . : 3 0-3 HP . : 0
REAR . . . . 0 .Oft BATH TUBS . . . . . . . . : 2 3- 15 HP . : 0 MODEL :
SIDE ( 1 ) . 0 .Oft SHOWERS . . . . . . . . . . : 0 FURN < 100K BTU : 0 15-30 HP . : 0 -MAKE------
SIDE (2 ) . 0 .Oft WATER HEATERS . . . . : 1 FURN >=100K BTU : 0 30-50 HP . : 0
SHRLINE . 0 .Oft CLOTHES WASHERS . . : 1 FURN - FLOOR . . . : 0 50+ HP . : 0 -YEAR------
AREA ---------------- KITCHEN SINKS . . . . : 1 HEAT PUMP . . . . . . : 0
LOT SIZE . . : FLOOR DRAINS . . . . . : 0 VENT SYSTEMS . . . : 0 EVAP COOLERS : 0 LENGTH : 0
BUILDING . . . : 1734sf DRINKING FOUNT . . . : 0 VENT FANS . . . . . . : 0 HOODS . . . . . . . : 0 WIDTH . : 0
BASEMENT . . . : Osf LAUNDRY TRAYS . . . . : 0 DOMES . INCIN :O -SERIAL#----
DECKS . . . . . . : 114sf DISHWASHERS . . . . . . : 1 AIR HANDLING UNITS-- COMML . INCIN :O
GAR/CARP :G 572sf GARB DISPOSALS . . . : 0 <= 10000 cfm . : 0 RELOC/ REPAIR : 0
AT/ DT . :A URINALS . . . . . . . . . . : 0 > 10000 cfm . : 0 OTHER UNITS . : 0
MISC PLM FIXTURES : 0 GAS OUTLETS . : 0
PROJECT DESCRIPT10N:9ESIDENCE
PROJECT LOCATION:NORTH ON BROCKDALE TO JENSEN RD TO STONEBRIAR 4TH LOT ON LEFT.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED FOR A PERIOD
OF 180 DAYS AT ANY TIME AFTER WORK IS COt"ED. EVIDENCE OF CONTINUATION OF WORK IS A PROGRESS INSPECTION WITHIN THE 180 DAY PERIOD. FINAL INSPECTION MUST BE
APPROVED BEFORE BUILDING CAN BE OCCUPIED.
OWNER OR AGENT:- //� DATE:
BLD-PRMT, rev: 03131191 COMPLIANCE TO ATTACHED CONDITIONS IS REQUIRED
CONCRETE �� MOBILE HOME
Footings-Setbackr/e date by Ribbons
date —22.-- by Gas Piping date b
Foundation Walls date by Set Up
date by INSULATION date by
BG/SLAB Insulation Floors Final
date by date by date by
FRAMING Walls FIRE DEPT.
date by date G-3-Q6 by I4- date by
PLUMBING vAµw ISR,1M Z �J o k OTHER
Groundwork Attic
date by date by
D.W.V. WALLBOARD NAILING
date _��Q� by date by t
Water Line
FINAL INSPECTION
date _3� �6 by �G `'`- dateQ-C(-q(p by date by
re l�i�/ �D_ /vO'v T S, !VAle 4
3-30-46 ��/ i f mow.3 n aw•,71 Prc,e E7� 8_ Ta Ae, eZ✓scL,Ije-a i-A-.4L.
G-3—`"6 J n
7 �� �fi ��tP�°/ }C[�� � G�iil� Lt�r�. P.�/ldl�✓) -t�iNi't�1�- Oki
y z
oeq
s
30 • .6 gQ b n/pi-' A-m f- Co At a
I
ECC b�
��
W -O"p [7 FC�L li, / 2
MASON COUNTY
Mason County Bldg. III 426 W, Cedar
P.O. Box 186 Shelton, Washington 98584
B tl 1 1., D 1 f4 " P F R M 1 T FOR I NSPFCT I ONk CALL 427-9670
BETWEEN Spm ANY Sam 427--7262
8L.D95 -1 70'9 PARCEL :3213232901 12 PLAT r D I V : ? BLK :7 LOT :?
,_JOB ADDRESS : F 121 STONEHIIIAR Pt 8IJFI.TON J
OWNER : VERMILLION CONSTRUCTION 791-5196 5
CONTRACTOR : MARK 0
` LEGAL : 11 11-8 OF SO N>t,NRt.Y OF CO RTN TR 2 Of SP #2267 �
fgrit^y�J'��5�. ^'i":��'T""..•:'.-1b'�22�2'J:9_,.� C}:f-�T P�:43t"��..:A...:..'�f.^..:TSYSY%!Y'YS�II'.SF:T.a�:A.1'Y'W.�.Z'tf3Yr^'.-'..SG
CLASS OF WORK :NEW BFDR : 3 BATH : :3 lYP1 AMOUNT BY PAT,*;:AECEIPT I1YPf ANOINT BY OATS RECEIPT
TYPE: OF USF . . . . :SF STORIES . . . . . . . :2 :.- - - - .�z. } ,��: �:�. : ::3: �
OCCUP . GROUP . — I? BLDG . HEIGHT - -. . 0 .0ft !PROT $ 396.00 TDO 02061 41214 fNf.P ; 10.00 TON 07116196 0174
I TYPE OF CONST . . r 7 FIREPLACES . 0 I PI M t 51.00 TON 02116tA 41274
I OCCLIP : LOAD . . . . : N WOODSTOVFS . . . . : 0 N{:B $ $9.40 TDB 021161# 4t274
DWE1 1. , UN ITS . , . , : 0 PARKING SPACESt 0 E TAP 1 25.00 ION 621 i611�A1274
INSPECTION AREA : 3 SHORELINE? , . . . :N STfI 1 4.50 TPH 02116196 1274 TOTAL: 525.'+0 VAtULAT10N: 6#376
SETBACKS--_._ _._..____.___ 101 LETS . . . . . . . . . . .. 3 FUFL. TYPES -- -- BOILFRS/COMP---- MOBILE HOME__.-
FRONT . . . 0 .0ft BATH BASINS - - : 13 : � 0- 3 HP . : 0
REAR . . . . 0 .Oft BATH TUBS . . . . . . . . : 2 3 -15 HP . : 0 MODEL :
SIDE ( 1 ) . 0 .Oft <<HOWFRS - . . . . . . . . . . 0 F'URN < 100K BTU : 0 15-30 HP . ,- 0 MAKE
SIDE (2.) . 0 .Oft WATER HEATERS . . . . : 1 FURN >m100K BTU : 0*1 30-50 HP . 1 0
SHR1. 1 NE . O .Oft C1_0THFS WASHERS . . : 1 F"URN FLOOR . . . : A 50+ HP . : 0 YEAR--
AREA - ---- -- -- - -- - KITCHEN SINKS . . . . : 1 HEAT PUMP . . . . . . . 0S
LOT SIZE . , FI OOR DRAINS : 0 VENT SYSTFMS, . . . - 01. EVAP COOLERS : 0 LENGTH : 0
BUILDING . . . : 1734 sf DRINKING FOUNT . . . : 0 VENT FANS — . . . HOODS . . . . . . . , P VJ I DT14 . : 0
BASEMENT . . . 0!,f I. AUNDRY TRAYS . . . . : 0 � DOMFS . i NC I N :N
DECKS . . . . . . : 1 1 4 sf D I S14WASHERS . . . . . . : 1 AIR HANDI. 1 NG UNITS 4 COMMt. , I Nf.: I N :0
GAR/CARP :C3 572t>f GARB DISPOSALS— : 0 « 10000 nim . : 0S RELOC/RFPAIR . 0
AT/DT . :A URINALS . . . . . . ; . . 0 > 10000 cfm . : 0v OTHER UNITS . : 0
MISC PLM FIX'fURE=S : 0 GAS OUTLETS . : 0
PROJECT NE5CRIPTIONrRESIDENCf y
(PROJECT i.00ATION,,NORTN ON BROCKDAtf TO JENSEN 10 TO STONfPRIAR 410 tOT OM LEFT.
This PERMIT RF.CONFS NIL1. APO VOl$ If 1089 OR CONSTRICTION AUT1111IE1 IS NOT CONNENCED 111810 180 DAYS if CONSTRICTION OR WORK IS SUSPFROFO FOR A PERIOD
OS 180 DAYS AT ANY TIME AFTER WOIW IS COME-NCE.O. FVIDEN('E OF CONYINBATiON OF 'WORK 1S A PR06NESS INSPFIIION MINIM THE 186 IIA? PERIOD. fl1AI I0SPfC110N 110S1 Sf
APPROVED REFORE RtRGI N0 CAN Of OCCOPIrU
OWNER OR AGENT: - � _ DATE:
BL0_PRMT, rev. 430119t OMPLIANCE 10 ATTACHED CONDPjIONS IS REQUIRED
r
Buildingla 1
Permit #��=��I MASON COUNTY
BUILDING III 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location �;
Zz,�.ea,ze llmlelr
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found:
Items listed below must be corrected to gain code compliance
6;r,4e-` %r✓5,c cif" ray"-r Azt-AfA: ,To4w!•
You are hereby notified that the above corrections shall be made BEFORE
PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ OK to
Department
Date ` �l/`, Inspector ewe"
■ oo $ NOOT Fi MO *V Ir 1 T
" ,�'
Building Permit # kMASON COUNTY
BUILDING III 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location / Z / Sfol�c��r� ✓ ��
rie-Yrvt 1/� � ►�
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found:
Items listed below must be corrected to gain code compliance
.-o n f TD I CAL I
ee, Q'a ,�,
&� �f w
k— ✓ ,i
Cz
a
i
You are hereby notified that the above corrections shall be made BEFORE
PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ OK to
Department
Date Inspector
■ �� [:4 OT vk Mo OV 11, T" o
E-cildin. Permit S - 7� �
g MASON COUNTY
BUILDING III 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
�I �Tv�� � 2 �
Job Location � 13.2l�
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found:
Items listed below must be corrected to gain code compliance
T-z ,'--09l ' AI' S 2EC7`- 01V
/gous;C LockF4�)
IVD 0 /l e X o u It
32, 60 -k�� 11v 0 7-/0 Z
o f 'yr Foe- &zX T /Al sp F'C T 6-c7
You are hereby notified that the above corrections shall be made BEFORE
PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ OK to
Department Za �l lam!
Date �`�- �� Inspector Z2 qS /'� -
■ 1:0T "
*0 MnV T -
,
Building Permit #2��—LDr MASON COUNTY
BUILDING III 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location TZ,?z
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found:
Items listed below must be corrected to gain code compliance
ICS
Gt t tf '&YA1
You are hereby notified that the above corrections shall be made BEFORE
PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
OK to
Department Gl/ /ltl
ite ^�,�� Inspector ,
P �� NOT MOV T 1 - T A
r T '�
Page No.t 1 CASE HISTORY FOR CASE NO.: BLD95-1709 \✓
VERMILLION CONSTRUCTION
E121 STONEBRIAR PL SHELTON
08/07/96
Action Description Req/ Schd/ End/ Action Notes Disp By pdate Upd
Code Sent Done Done Date By
BLDA010 Application received / / / / 12/06/95 12/06/95 KW
BLDA100 Approved For Issuance / / / / 12/18/95 DONE KS 12/21/95 KS
BLDA500 (F) Issue building permit / / / / 02/16/96 DONE TDH 02/16/96 TDH
BLDB110 Structural Plan Review 12/15/95 / / 12/18/95 DONE WLC 12/18/95 WLC
BLDB120 WSEC Compliance Review 12/18/95 / / 12/19/95 They have completed the stuff for EH. DONE TDH 12/19/95 TDH
When you are done please return to me
for sign-off. Thanks, Pam Denton.
waiting for ltsgc agreement....will
approve anyway because he always goes
ltsgc
BLDB121 LTSGC 12/19/95 / / 12/19/95 DONE TDH 12/19/95 TDH
BLDB130 Planning Review 12/06/95 / / 12/13/95 DONE GBM 12/13/95 GBM
BLDB134 RLC Checklist Review / / / / 12/13/95 no rlc at this time NATT GBM 12/13/95 GBM
BLDB135 Addressing / / / / 12/08/95 DONE GMM 12/08/95 GMM
BLDB200 Environmental Health Review 12/06/95 / / 12/06/95 Approved design, the plot plans don't HOLD PSD 12/12/95 PSD
match. The building plot plan shows the
building 120' from the road and the
septic design shows the septic system
120' from the road. The plot plans need
to match. psd
12/12/95 I spoke to mark Vermillion and
according to him the plot plans have
been changed. need to verify that the
plot plans match.psd
BLDB200 Environmental Health Review 12/19/95 / / 12/21/95 The plot plans have been changed.psd DONE PSD 12/21/95 PSD
BLDB210 Water Adequacy 12/06/95 / / 12/06/95 Stonebriar #2 is in compliance, current DONE PSD 12/07/95 PSD
WFI,bacte,and nitrate sample in the
file.psd
BLDC110 Footing inspection 02/15/96 / / 02/21/96 NOT READY FOR INSPECTION, FAIL GDR 02/21/96 GDR
BLDC110 Footing inspection 02/21/96 / / 02/22/96 PASS GDR 02/22/96 GDR
r ,
Page No. 2 CASE HISTORY FOR CASE NO.: BLD95-1709
l VERMILLION CONSTRUCTION
E121 STONEBRIAR PL SHELTON
08/07/96
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDC140 Fr/P1/Mc/Pen Inspection 05/21/96 / / 05/22/96 1. NAIL GARAGE WALL PLATES TO TREATED FAIL GDR 05/28/96 GDR
SILL PLATE WITH 16d SINKERS AT 16"
O.C..
2. NO TEST OF D.W.V. OR COPPER WATER
LINE.
3. MECHANICAL FAN DUCTS NOT CONNECTED.
4. STRAP (ALL ) SINGLE TOP PLATES THAT
ARE NOT INTERCONNECTED.
5. NAIL (ALL) INTERIOR WALL PLATES DOWN
WITH 16d SINKERS AT 16" O.C..
6. FINISH CAULKING OR SEALING ALL TOP
AND BOTTOM PLATES PENETRATIONS.
7. NO FLEX METAL DUCT IN CONCELLED
SPACES WSEC AND UMC.
8. PROVIDE ENGINEERING FOR GLUE-LUM
BEAM IN KITCHEN THAT HAS BEEN DRILLED
AND BOARD.
9. FLOOR JOIST REQUIRE 3 8d SINKERS TO
PLATES.
10. MIN CEILING HEADER HEIGHT AT STAIRS
6'-8" FINISH TO FINISH.
11. WHEN USEING FLEX DUCT IN ATTIC SPACE
SIZE SHALL BE 1 SIZE LARGER THAN MIM.
REQUIRED 4" TO 5" MIM. WITH 3
MECHANICAL FASTENERS.
12. OVER FRAMING AT RAFTERS AT RIDGE
BOARD SHALL BE EQUAL TO OR LARGER THAN
CUT END OF RAFTERS. (TYPICAL ALL) .
13. BONUS ROOM STRAP TOP PLATES TO
GLUE-LAM BEAM BOTH SIDES AND ENDS.
14. ALL D.W.V. PIPING SHALL BE SUPPORTED
MAX 48" O.C.
15. NOT A COMPLETE INSPECTION, NOT READY
FOR F.P.M.P. INSPECTION.
BLDC140 Fr/P1/Mc/Pen Inspection 05/28/96 05/30/96 05/30/96 ALL ITEMS FROM 5-22-96 COMPLETED EXCEPT FAIL SKM 05/31/96 SKM
# 8 DUSTY REQUIRED ENGINEERING FOR
GLU-LAM THAT HAD BEEN BORED .
OK TO INSULATE.
BLDC145 Insulation inspection 05/31/96 06/03/96 06/03/96 DONE SKM 06/03/96 PMS
BLDC150 Wallboard inspection 06/13/96 06/13/96 06/13/96 allen drywall C&P WLC 06/13/96 TDH
Building Permit # ,MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASHINGTON 98584
Z'— (360) 427-9670
CORRECTION NOTICE
Job Location
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
`found:
Items listed below must be corrected to gain code compliance
'47
14
K
if T'��[ /��✓r//f�� /�C9�-- ����..r��l��j ����� /.,�!_'_ ��/��1�/'
You are hereby notified that the above corrections shall be made BEFORE
PROCEEDING WITH ANY FURTHER WORK ��
❑ Call for re-inspection when corrections are made before continuing❑ Make corrections, items will be checked on next inspection
❑ OK to �� ��
Department �� ��� 1 l
Date _�-Z I Inspector pu 1bC
Un NUT MnV T 1 TAU-
MASON COUNTY
Mason County Bldg. III 426 W. Cedar
P.O. Box 186 Shelton, Washington 98584
PE : P1\4 1 T G01N0 1 1 1 ON
Case No . a B1.095-1 709
For r VER1.41 t_t_ ION CONSTRUCT ION
Pages
1 ) T he uso, hand I I ng anti storacaa of hazardoufc mat or i a l s or f 1 am►nab 1 e and c?ombust i b l e
liquids In excess of 10 gai `lons is not allowed without the approval of the Mason County
Fire Marshal
X
2 ) Proposed structu -e car anv Fort ion thereof cheater than 30" In height from grade line,
must m,a�lnVai inimum of 5 ' setback from all property lines , easements and right of
ways l ,
3 ) At approved plans are required to be on- site for Inspec:tlon purposes . If inspection
Is called for and plans are not on site, Approval WILL NOf be granted . In addition, a
Re- inspection fee in the amount of $30 .00 per hour (minimum 1 hour ) will be charged and
must be collected by this department prior to any foirther inspections being performed or
approval`
X
4 ) PURSUANT TO 1991 UNIFORM BUILDING COLIC SECTION 305(C ) AND SFCT I ON 513 ALL S I IFS MUSS 1
HAVE APPROVED NUMBERS OR ADDRESSES PR6VIDED IN SUCH A POSITION AS TO Bt PLAINLY VISIBLE
AND LFG I SL F FROM THE STRE FT CAR ROAD FRON1 I NG I'HF PROPERTY . MASON COUN 1-Y BU I LD I Nr
DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS . A
REINSPECTION FEE , BASED ON RATES IN TABLE 3A OF THE 1991 UNIFORM BUILDING CODE Wilt, Bu
ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING
INSP N �
x l
5 ) The correot 1 can i i st . a I ong w I t h t he E ner-gv Comp i t anue Wor k sheet (Wbe:n app i i r:nb 1 e ) is
part of the plans and must remain attached thereto . It is the responsibilityy of the
applicant to make corrections indicated on the KK►Ians from the Correction lists . Once
the plans are marked APPROVED they may not be ehanged or, altered without authorization
from the Building Official . the permit holder Is reponsible to retain the complete
approved :3et of plans on site for the duration of the project . Failure to comply will
result In failure of required building inspections . Every permit shall expire by
MASON COUNTY i
Mason County Bldg. III 426 W. Cedar
P.O. Box 186 Shelton, Washington 98584
limitation an c- ote null and void the building or work au+ .,.)rized by such permits
Is not commenced within 180 days from the date of Is"anoe, or if the buildinr or work
authorized by such permits Is suspended or aban�jo,Fr� at "any time after the work is
commenced for a period of 180 day;; . XT
6) ALL , J .1 A ON MUST MEET OR EXCEED AL.I. LOCAL CODES AND UBC REQUIREMENTS .
X
T ) Changes to approved building plans that effect compliance to the 1991 Washington State
Energy Code, 19g1 Ventilation and Indoor Air Qualityy ^
Code, the Unitor�a But (ding Code and/or Mason County Regula grlr 11
be approved by Mason County prior to constructionX
8 ) ALL CO STRU TI MUST MEED OR EXCEED LOCAL CODES . IF ANY OUE.STIONS, PIEASE�
CALL F E BEFORE CONSTRUCTION .
S) CONSTRUCTION PROCESS TO BE FIELD CORRECTEbV-
10) E IREJ PER MASON COUNTY BUILDING
DEPARTMENT AND UNIFORM BUILDING CODE .x
f -
MASON COUNTY BUILDING DEPARTMENT
1991 WASHINGTON STATE ENERGY CODE
AND
VENTILATION AND INDOOR AIR QUALITY CODE
RESIDENTIAL REQUIREMENTS (NEW CONSTRUCTION, ADDITIONS, &REMODELS)
THE PROCESSING OF YOUR APPLICATION CAN BE EXPEDITED IF YOU PROVIDE
COMPLETE AND DETAILED INFORMATION.
YOU ARE ENCOURAGED TO COMPLY TO THE 1991 WSEC BY UTILIZING THE
APPROPRIATE PRESCRIPTIVE PATH FOR YOUR PROJECT. THIS WILL ALSO
HELP EXPEDITE MATTERS.
THE FOLLOWING INFORMATION MUST BE PROVIDED:
1) A complete window schedule must be submitted with your WSEC compliance
information, even if a window schedule is included on your building plans. Note that
sliding glass doors (patio), french doors, and any door with 50% or more glass in it is
considered a window with the area (sq.ft.) being the entire units rough opening
dimensions. Any windows in doors (less than 50% of area) must be taken out of the
door area and put into the window area on the schedule.
Include the rough openings of each window, the model (casement, horizontal slider,
single hung, awning, picture, etc...), and the units tested U-value.
2) If you are complying to the WSEC by prescriptive path and are using the area weighted
averaging method you must include your calculations (worksheet).
3) Indicate type of hot water heater, location of exhaust fans (bathrooms, laundry,
kitchen), the location of your whole house fan, and all insulation levels (walls, floors,
ceilings, and slab) on your building plans.
4) Indicate how you will comply with the requirement for introducing fresh air to each
habitable room on your building plans (window frame vents, through the wall ports, or
an integrated system with your furnace).
If you have questions about compliance the 1991 Washington State Energy code or 1991
Ventilation and Indoor Air Quality Codes, call Toni Hermansen or Debbera Coker at 427-9670
or 1-800-562-5628, ext 284.
Prescriptive Requirements'For Residential Occupancies
Heating by Electric Resistance Zone 1
Option Glazing% Glazing Doors Ceiling Vaulted Wall Above Wall/into Walllext4 Floors Slab on
Floor Area U-Value U-Value Ceiling Grade Below Below Grade Grade
Grade
1. 101% 0.46 0.40 R-38 R-30 R-21 R-21 R-10 R-30 R-10
11, 12% 0.43 0.20 R-38 R-30 R-19 R-19 R-10 R-30 R-10
III. 12% 0.40 0.40 R-38 R-30 R-21 R-21 R-10 R30 R-10
IV.' 15% 0.40 0.20 R-38 R-30 R-19 R-19 R-10 R-30 R-10
V. 18% 0.39 0.20 R38 R-30 R-21 R-21 R-10 R30 R-10
VI. 21% 0.36 0.20 R.38 R-30 R-21 R-21 R-10 R-30 R-10
VII 7 25% 0.32 - 0.20 R38 R-30 R-19+R-56 R-21 R-10 R-30 R-10
VIII.7 301/6 0.29 0.20 R38 R-30 R-19+R-58 R-21 R-10 R30 R-10
'Relerence Case
1 Minimum regufrernerts for each option listed.For example,I a proposed design has a glazing ratio to the oondtioned floor area of 19%it shall oonply vAh all of the requirements of the
21%94mih9 option(-higher).Pnapoeed designs which caned meet the specific requiromerds of a feted opton above,may celadade compliance by Chapters 4 or 5 of this Code.
2 Regt*onwtt applies to al oa'hhps except single rafter or joist vaulted caliings.'Adv'decades Advanced Framed Ceiling.
3 Requirement a{plieeble only to single ndter or joist vaulted celigs.
4 Belau grade walk shall be Insulated either on the exterior to a minimum level of R-10,or on the interior to the same level as wafts above grade.Exterior Insulation installed as below trade
wah shall be a water resistant material.manufactured for its intended use,and installed according to the manulacW 's sped5caliom,See section 6o22.
5 Floors over crgM spaces or exposed to antiiert air conditions.
6 Required slab perimeter imu4fion sha0 be a water resistant material.manufactured for its intended use,and insWied according to ma sfagver s apecirridbra.See section 602.4.
7 The following options shall be applicable to buildings Was than three stories:03.5 r axirnu m for glazing area of 25%or less:o.32 maximum for glazing areas of 30%or less.
8 This wall insulation requirement derhases R-19 wall cavity insulation plus R-5 loam sheathing.
Excerpted from WSEC Table 6-1
Prescriptive Requirements'For Residential Occupancies
- Heating by Other Fuels Zone 1
Option HVAC' Glazing Glazing Doors Ceiling Vaulted Wall Wall/into Wall/ext4 Floor Slab"
Equp.% Floor Area U-Value U-Value Ceiling Above Below Below on
EfTfc. Grade Grade Grade Grade
I. Med. 101/6 0.70 0.40 R30 R-30 R-15 R-15 R-10 R-19 R-10
11, Med. 12'/6 0.65 0.40 R-30 R30 R-15 R-15 R-10 R-19 R-10
III. High 21% 0.75 0.40 R30 R-30 R-19 R-19 R-10 R-19 R-10
IV.' Med. 21% 0.65 0.40 R30 R30 R-19 R-19 R-10 R-19 R-10
V. Low 21% 0.60 0.40 R30 R30 R-19 R-19 R-10 R-19 R-10
VI.7 Med. 25% 0.45 0.40 R38 R30 R-19 R-19 R-10 R-25 R-10
VII 7 Med. 30% 0.40 0.40 R30 R-30 R-19 R-19 R-10 R-25 R-10
'Reference Case
1 Minimum requirements for each option fisted.For example.I a proposed design has a glazing ratio to the conditioned floor area of I M it shall comply with an of the requirements of the
21%glazing option(or higher).Proposed designs which earshot meet the specific requirements of a fisted option above.may calculate compliance by Chapters 4 or 5 of this Code.
2 Requirement applies to all ceilings except single rafter or joist vaulted oeiings.'Adv"denotes Advanced Framed Ceiling.
3 Requirsonai applicable only to single rafter or joist vaulted ceilings.
4 Below grade wall dual be isolated efthher on the exterior to a minimum level of R-10,or on the interior to the same"as walk above grade.Exterior insulation istalled on below
grade wall"be a water resistant mnlerFal.man Aadured forts intended use.and installed acroadirg to the manufacturer's specifications.See section 6022
5 Floors over crawl spaces or ex posed b ambient air conditions.
6 Required slab perinster insulation shall boa water resistant materiat manufactured for its intonded use,and ihstalled s000rding to manufaciurer's specifications.See section 6M4.
7 The following options shalt be appic"to buildings less than three stories:0.50 maximum for glazing areas of 25%or less:0.45 maximum for glazing areas of 30%or less.
8 This wall insulation requiremert denotes R-19 wall cavity i suidion plus R-5 foam sheathing.
9 Minimum HVAC Equipment efficiency requirement.'l,ov/denotes an AFUE of 0.74.'Mad.'denotes an AFUE of 0.78.'High'denies an AFUE of 0M.
Excerpted from WSEC Table 6-2
i Log Homes Prescriptive Requirements)
Heating By Electric Resistance
Option Average2 Log Glazing% Glazing Doors Ceiling3 Vaulted4 Floor SIab6 on
Thickness Floor Area U-Value U-Value Ceiling Grade
Climate Zone 1
1.7 5.5' 15% 0.31 0.14 R-60Adv R-38 R-38 R-10
11.7 7.5' 15% 0.40 0.20 FI-60Adv R-38 R-30 R-10
III.' 9.6' 15% 0.40 0.20 R-38 R30 R-30 R-10
'Rderonce Case
1 For Group R Occupancy use Table 6-5 for only the portion of floor area using log/solid linter walls.Use Tables 6-1 to 64 for at other portions of the floor area Minimum requirements
we
by for each
nopor 5 d tion list ed Interpolations between options is not permitted.Proposed designs which cannot meet the specific requirements of a listed option above.may calwlate ocr pliwxoe
e.
2 Required minimum average leg thicluhess.
3'Adv'denotes Advanced Framing.Requirement applies to at ce8iogs mxcept single falter joist vaulted ceilings.
4 Requirement applicable only to single rafter joist vaulted ceilings.
5 Floors over crawl spaces or exposed to ambient air conditions.
6 Required slab peril rotor insulation shelf be water-ressUnt material,manufacturm to,its intended use,and installed according to manvfaciurer a specifications.
7 Those options shall be applicable to buildings less than!hrne sto,;.
MASON COUNTY BUILDING DEPARTMENT
1991 WASHINGTON STATE ENERGY CODE
AND
VENTILATION AND INDOOR AIR QUALITY CODE
OWNER / i ��� � TELEPHONE
COMPLIANCE INFORMATION
TYPE OF PROJECT: ( N RED EJyCE )ADDITION O REMODEL O OTHER
AREA(SQ.FT.) 1ST FLOOR 2ND FLOOR HEATED BASEMENT
Note: Heated basements must be insulated and finished to meet minimum energy code requirements.
TOTAL SQUARE FOOTAGE OF CONDITIONED MUTED) AREA
COMPLIANCE METHOD:
( ) PRESCRIPTIVE PATH — circle option — I II III IV V VI VII VIII
Glazing percentage (total glazing area divided by total conditioned area)
() COMPONENT PERFORMANCE — Chapter 5 — attach documentation and worksheets
() SYSTEMS ANALYSIS — WATTSUN 5.2 -- attach documentation and worksheets
WATER HEATER
K Electric water heater () Gas water heater
HEATING SYSTEM:
ELECTRIC RESISTANCE
Electric Central Furnace () Electric Wall Heaters ( ) Baseboard Units
( ) Radiant Panels () Other
OTHER FUELS
Heat Pump with electric furnace ( ) Heat pump with gas furnace ( ) Gas Furnace ( ) Oil Furnace
() Other () Boiler System (indicate type)
Make Model
Size AFUE HSPF
VENTILATION SYSTEM:
O Spot and Whole House () Central Ducted System ('bQ,Integrated with Furnace
( ) Heat Recovery System (air to air heat exchanger — heat recovery heat pump)
GENERAL NOTES:
Your building plans should indicate certain compliance measures: framing to be used (standard,
intermediate, advanced); type of vapor barriers being used; location of furnaces, hot water tanks and
other equipment; location of solid fuel burning appliances, fireplaces and thei:combustion air duct runs;
and termination points of exhaust ventilation fans.
WINDOW & DOOR SCHEDULE [[[
WINDOWS
INCLUDE ALL WINDOWS, SKYLIGHTS, SLIDING GLASS DOORS, FRENCH DOORS AND
STORE DOORS. ANY WINDOWS IN DOORS (LESS THAN 50% OF AREA) MUST BE
TAKEN OUT OF THE DOOR AREA AND PUT INTO THE WINDOW AREA ON THE
SCHEDULE.
BRAND MODEL U-VALUE QUANTITY SIZE TOTAL SQ. FT.
TOTAL WINDOW AREA
DOORS
BRAND MODEL U-VALUE LOCATION SIZE TOTAL SQ. FT.
TOTAL DOOR AREA
i
\; \ Permit No.
MASON COUNTY
Q �g95 UILDING PERMIT APPLICATION y5g5 ag
42 (tSedar/P.O. Box 186, Shelton, WA 98584 427-9670/1-800-562-5628 b
PLEAS T �I�"
#1 ��✓`�Chi/ A Phone#
� ii; >r,:/
Site!Address E a� STowEf3�A.� A/.�_ Fire District#
City LiN : St Wo— _Zip �g
Directions to Job Site fvo,2 &J�'i 7--0
`r-D S k- La
Owner Mailing Address >��-/y'" ! �� 7-S 4/' � .a _
City �� Sty' Zip
-7
Lien/Title Holder
Address 'f,(f'
City St Zip
#2 Contractor,Name /_ l _� /�'�, / ,%'/J Contractor Reg# V eX-M 'C Iz 65TZ-
Address f S Expiration Date
City st�z Zip :' Phone#, '�i/_ ! '�
#3 If septic is located on project site, include records.
Connect to Septic?--�& Public Water Supply Well
Connect to Sewer System? Name of System 5'r�l�(�,12 4�, A-F e4L S !Is r- -,,n
(If res' ential, proof of potable water is required)
#44arcrcel No.-3 a/3a -�3 - 9D 1,a
JV Legal Description 2 '1-0-TJ Q- o
/off 4 a o `apt aortal
#5 Building Square age: (exis ing/proposed)
1st FI AVA2nd FI 3rd FI —f-- Loft �--
Basement —f- Deck // bedrooms 3 / #bathrooms /
Garage x.52'72L Carport (Circle:( tt h for Detached?)
Other �} sq.ft. /
#6 Use of building �&,.1" Describe work IV44,%) /->Lc7
#7 Type of Job: New Add Alt Repair Other
#8 MOBILE/MANUFACTURED HOME INFORMATION
Model Year Make Model
Length Width Serial No.
# Bedrooms # Bathrooms Type of Heat
Purchase Price $
#9 Indicate by circling the applicable source if any water is on or adjacent to subject property:
River Pond Creek Stream Wetland Lake Marsh Saltwater Seasonal Runoff Other
Show following on the site plan
Lot Dimensions Flood Zones
Existing Structures Fences
Structure Setbacks Driveways
Water Lines Shorelines
Drainage Plan Topography
Septic Systems Wells
Proposed Improvements Easements
Name of Flanking Street Indicate Directional by (N, S, E, W)
Name of Fronting Street in relation to plot plan
APPLICANT TO DRAW SITE PLAN BELOW
� y
I
J
APPLICANT TO AW TOPOGRAPHY PROFILE BELOW
I
Plumbing Fixtures ($3 each) Fee Mechanical Fixtures ($6 each)
No. Toilets CIRCLE FUEL TYPE: Gas, Electric,
•a Bath Basins Heatpump, Other
-O Bath Tubs No. Units Fees
Showers E Furn BTU
Hot Water Htr Heatpumps
Laundry Washer _ Vent Systems
Sinks Spot Vent Fans
Floor Drains No. Boilers/Compressors
Laundry Basins HP
! Dishwasher No. Air Handling
Disposal _ cfm#
Urinals No. Fire Protection Systems
Other _ Auto. Fire Alarm Sys 50.00
Fixed Fire Supp. Sys 50.00
Permit Basic Fee 15.00 _ Auto Fire Sprink Sys 25.00
TOTAL PLUMBING $ . Other
Gas Outlets
Woo<, G�s, ellet Stove 1
NOTICE: THIS PERMIT BECOMES NULL AND VOID IF
WORK OR CONSTRUCTION AUTHORIZED IS NOT COM-
MENCED WITHIN 180 DAYS OR IF CONSTRUCTION OR Permit Basic Fee 15.00
WORK IS SUSPENDED OR ABANDONED FOR A PERIOD
OF 180 DAYS AT ANY TIME AFTER WORK IS COM- TOTAL MECHANICAL $ 3�
MENCED. PROOF OF CONTINUATION OF WORK IS BY
MEANS OF A PROGRESS INSPECTION.
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIRE- I CERTIFY THAT I AM A CURRENTLY REGISTERED
MENTS OF THE CONTRACTORS REGISTRATION LAW CONTRACTOR IN THE STATE OF WASHINGTON AND I
RCW 18.27, AND AM AWARE OF THE MASON COUNTY AM AWARE OF THE ORDINANCE REQUIREMENTS REGU-
ORDINANCE REQUIREMENTS FOR WHICH THIS PER- LATING THE WORK FOR WHICH THE PERMIT IS ISSUED
MIT IS ISSUED AND THAT ALL WORK DONE WILL BE IN AND ALL WORK DONE WILL BE IN CONFORMANCE
CONFORMANCE THEREWITH. NO CHANGES SHALL BE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT
MADE WITHOUT FIRST OBTAINING APPROVAL FROM FIRST OBTAINING APPROVAL FROM THE BUILDING
THE BUILDING DEPARTMENT DEPARTMENT.
XOWNE ��' L� XB
DATE DATE
FOR OFFICIAL USE ONLY: Accepted by Date:
J
DEPARTMENTAL REVIEW
FOR OFFICE USE ONLY
Approved Cond. Hold
Approval
Planning:
Environmental Health:
Building Plan Review Lv
e� ITS
Occupancy Group: 3 t— pe of Const: S�
Fire Marshal:
Other:
Special Conditions: FEES
Building Permit 3� O
Plan Check K -�—
Plumbing Fee SI- d(Z.
Mechanical Fee 5 •
ood/ s/Pellet Stove e:i,
Radon Monitor
Violation Fee
Site Inspection
Building State Fee
Other _ 1F1 D,pn
Other
Building Valuation: ta3 bj 3 7f,::> TOTAL FEE