Loading...
HomeMy WebLinkAboutBLD2007-00499 Final SFR - BLD Permit / Conditions - 10/22/2007 r I Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 111426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-00499 OWNER: VINCELLE DURAND RECEIVED: 3/26/2007 CONTRACTOR: ADAIR HOMES INC. LICENSE:ADAIRH*262RZ EXP: 1/9/2009 ISSUED: 6/14/2007 SITE ADDRESS: 80 E TYLER LN SHELTON EXPIRES: 12/14/2007 PARCEL NUMBER: 321322290054 LEGAL DESCRIPTION: TR 5 NW NW LOT: D OF SP#884 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SINGLE FAMILY RESIDENCE BROCKDALE ROAD, R ON JENSEN RD, L ON TYLER LN, TO SITE STOCK#2003-0019 GARAGE OPTION #2 REVERSED ADDRESS AT THE END General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: 2 Occ. Group: R-3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building:1,702 Garage-Attached 440 Valuation: Building Height: 17 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: E 25.0 Ft. Shoreline: 250.0 Ft. Water Body: John's Creek SEPA?: No Model: Width: Ft. Rear: W .0 Ft. Slope: Ft. Shoreline Des Side 1: N 264 i.0 Ft. g" Year: Serial No.: Side 2: S 36.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Planning Review Fee GMM 3/26/2007 $170.00 S12007000 Hosebibs 3 Ventilation Fan 3 Plan Check Fee GMM 3/26/2007 $239.07 S12007000 Kitchen Sink 1 Dryer Vent 1 Building Permit Fee GMM 3/26/2007 $1.12 S12007000 Lavatories 2 EH Plan Review TW 4/12/2007 $75.00 S12007000 Water Closets (Toilets) 2 Building State Fee ARC 4/13/2007 $4.50 S12007000 Water Heaters 1 Building Permit Fee ARC 4/13/2007 $1,200.95 S12007000 Bath Tubs 2 Mechanical Fee ARC 4/13/2007 $43.75 S12007000 Clothes Washer 1 Mechanical Base Fee ARC 4/13/2007 $25.30 S12007000 Plumbing Fee ARC 4/13/2007 $82.50 S12007000 Plumbing Base Fee ARC 4/13/2007 $22.00 S12007000 Total $1,864.19 BLD2007-00499 Please refer to the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2007-00499 CONDITIONS FOR BLD2007-00499 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X .ca 2) Mason County Building Codes Standards for Fire Apparatus Access Roads Chapter 14.17.160 require posting address at driveway beginning---no other issues for Fire/Ems. X------- r-------------------- 3) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X ,.'Y is; - 4) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 5) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 6) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X BLD2007-00499 Please referto the following pages for conditions of this permit. 2 of 5 7). The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated'on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X -� 8) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X } 9) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X " 10) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Tye��,/�M�;ax U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X '"4L 11) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X =+ - 12) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X 13) Stock Plan Identification number: 2003-0019 This project is approved subject to the provisions identified the Mason County Stock Plan Policy. The site plan approved by the Planning Department, original building plans, and all attachments approved by the Mason County Building Department shall be available for the Mason County Building Inspector at each required inspection. X 14) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X -<'=1 15) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation X BLD2007-00499 Please referto the following pages for conditions of this permit. 3 of 5 6) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the Stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 17) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X 18) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shali.be made prior to requesting additional inspections. X ` 19) All property lines shall be clearly identified at the time of foundation inspection. X - 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 21) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 22) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. Xta. 23) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 24) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X BLD2007-00499 Please referto the following pages for conditions of this permit. 4 of 5 25) Water quali�_i5 not to be degraded to the detriment of the aquatic environment as a result of this project. X S 26) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X ;, ; 27) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing must be - installed and maintained until upland vegetation has become established. X s 28) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 29) 1. First habitable floor must be elevated at least 2 feet above surrounding grade. 2. Mobile homes must be securely anchored. 3. Foundation or skirting vents must be within 1 foot of grade. 4. An elevation certificate must be completed by a licenced land surveyor certifying the as-built elevation of the first floor to the nearest 10th of a foot prior to final inspection. X 30) Subject to conditions of Aquifer Notification letter. X �; This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and struct a for revi d_inspection. OWNER OR AGENT: DATE: - - _ BLD2007-00499 Please refer to the following pages for conditions of this permit. 5 of 5 W r . o CONCRETE MECHANICAL MANUFACTURED HOME �/ C o Date � d'1 By LtQ1(, Footings 1 Setbacks G7l Gas Piping Ribbons D o Interior Date I By ( interior-Date BY Date By Z Exterior Date B DIY' - v�/ Y Exterior-Rate B co Set-up < Point Load I Isolated Footings INSULATION Date By Z BG!SLAB INSULATION -- 0 Date By Data By FIRE DEPARTMENT M Foundation Walls r Floors Date By ril Date 6 p-I Byt3r bate By &4L DECKS FRAMING Walla Date By Date$ ILA O-t By L1J1G Data '9 l6 d-7 By L.O- PROPANE TANKS PLUMBING vault Date By Date 11107 By OTHER Groundwork Attic Data By Date _ ByType:Date 8y D.W.V DRYWALL Type: Int Brace Wall Date By W Date I '' BY c�Y Date q a &"I By Boil., FINAL INSPECT N C v Water Lane Fire Separation N m Da1e Q By L14� Date By Date /Q -z 7 By !4/fC-- C `° Pass or Request Inspect c Type of Insp. Fail Date Date Done By Comments P)M tO)L_ 7-r 0 a C Pi-si �1 001 It, in (--011 I,.rz•t\ �.. �S�✓ I�IS Q�s ) �3 i vl � ti s �.,pic,- b Smirk Z '� S1�t t letvka I � � !� ID d`1 o ll �i 0 A 44 tA, C -7 OM PLOT PLAN Name Mailing Address Home #(mo Work # — Cell Property Locotion-00 E, jwd& 1'1, S k U L.-I--c"k-) 0 A Legal Address T5 z \Aj Sec i Tax Lot # County, 5tate of THE I NFORMATI ON ON TPUS PLOT PLAIT I IAS BE EI I PROVIDED A I Jb REV I E%VC I),,,II IE In r)P[n i y OWNER WHO BY 516HI NG 0 ELO%V:1)A CKI 10 WL E b6 E 5 A I It,A ccc P I s r IA L 1;E 5 rot I,I,IL I I Y FOR ITS ACCURACY AND COMPLETVIE55.2)15 RE 51"JI 151 OLE TO El ISUnC II 1,A r I)IC IMPROVE)AENTS TO THE 511 E TAKE PLACE I I it:OIIFOnM At ICE WITI 1 11115 PI.At L 3)%V I I.L SCALE: V 4c)' ESTABLI 511 ALL TI IE CORNER IRONS,LOT LIt)E5 At ID Coor-REq Imm)5E rrIACI:5 n(qIjI nEt)of: THIS PROPERTY.ANY CHANGE(S)TO TI If 5 PLAN MU5 T BE FnE-APPROVED BY II IE GOVEW)MENTAL AGENCIES WI TI I 1L)RI St)IIC T"OtT TIIEIIORTGIrE LEI l)En/AIR) 11F.CONTRACTM AND DOCuM'I ITED. 4 c OWNER SIGNATURE A OWNER SIGNATURE PATE ay Y PLAN PLOT REVISION DATE RECEIVED CJAJ CV APP ED MASON COU Y DCD PLANNING SITE PLAN UIREo TO BE ON SITE CHANG SUBJECT TO APPROVAL By Date -S 102 A0 < C17 h PLANNING . ALL SETBACKS ARE MEASURED FROM THE FURTHEST 3 L_I`ROJECTION OF THE BUILDING L y '30 + 'n/05/2007 08:03 3G042G7557 GERLACH LLC III PAGE 01r'02 tnrormawn ror pelCzn v xs.L vzvv i-vu-tyy roc i ci c MASON COUNTY Government and • • L s Building; Dept ► Some information/ uses may net be displayed ► This information may be outdated and inaccurate Planning dept ► Information is only for the unincoporated areas of Mason County ar show items since April 1st, 1992 Em ironmental Health ► Please contact the Permit Center (360) 427-9670 ext 352 to verify DqA information Records ► This information was last updated: 10/03/2007 at 10:58 am ► Building permits are NOT ready to issue until Case Status is APP a New Sea Ch activity "Approved for Issuance" is listed Assessor/ Information for Permit: BLO2007-00499 Treasurer Case Number BLD2007- Parcel Information 00499 VINCELLE DURAND Case Statu' ISS Applicant 141 W LOERTCHF_R RD Parcel 321322290054 SHELTON WA 98584 Number Project 80 E TYLER LN SHELTON Address Valuation ? $ 136,275,60 Description NEW SINGLE FAMILY RESIDENCE STOCK# 2003-OC GARAGE OPTION #2 REV ERSED Activities Date Date Assigi Description Assigned Done Status To. Wallboard Inspection 08/31/2007 09/04/2007 PASS Framing/Plumbing/Mechanical08/14/2007 08/16/2007 PASS ITEM#2 STILL NOT COMPLETED Insulation Inspection 08/14/2007 08/16/2007 PASS WALL FraminglPlumbing/Mechanical 08/08/2007 08/09/2007 Item#2 still not complete. Framing/Plumbing/Mechanical 07/30/2007 07/31/2007 FAIL 1. FRONT OF GARAGE T-111 NOT NAILED OFF PER ABP REQUIREMENTS 6" OC AND 12" OC IN FIELF 2. NAIL T-1I I TO SILL PLATE AT 6" NOT JUST BOTTOM PLA 3. CAULK AND SEAL NOT COMPLETED 4. IS SUPPLY(WATER)CONNECTED TO COULD NOT FIND TEST GAUGE 5, ALL TOP PLATE SPLICES LESS THAN 2 ARE f TO HAVE METAL CONNECTION Wt77i MIM 6-8,DS EACH SIDE OF SPLICE SEE WF httv� /hxaxnu rn rrYa�nt zxra tticlriarrti,itclrnai„wl,n'7nao..,,..—uT n�nn'7_nna00 '0/05/2007 08:03 3604267557 GERLACH LLC III PAGE 02/02 lmorinauon Ior pit: ss i uavv i-v i vA_P -o_ _ _•- Building Plan Review 06/11/2007 06/29/2007 DONE ARC STOCK 2003-0022 WSEC Compliance Review 0612=007 DONE ARC Environmental Health Review 06/11/2007 06/25/2007 DONE TW BEDROOMS AND PLOT PLANS OK. MUST KEEP 54FT SETBACK FROM SIDE YARD TO THE NORTH. More Info Letter-EH 06/25/2007 DONE TW Need approved two parry well.Two party pending recorded Notice to Future Property owners of Private Two Party well, Need a recorded copy I Fire Warden Review 06/11/2007 06/19/2007 DONE DHS Property cleared and level--no Issues for Fire/Ems Apparatus, Application Received 06/11/2007 06/11/2007 CONE KKK Permit Fees Fee Type Amount Due Amount Paid Building Permit Fee $ 1,402.55 $ 1,402.55 Plan Check Fee $280.51 $280.51 Planning Review Fee $ 170.00 $ 170.00 Plumbing Fee $97-90 $97.90 EH Plan Review $75.00 $ 75.00 Fire Warden Review $64.00 $64.00 Mechanical Fee $60.00 $ 60.00 Mechanical Base Fee $25.30 $25,30 Plumbing Base Fee $22.00 $22.00 Building State Fee $4.50 $4.50 Total Fees. $2,201.76 $2,201.76 Amount Outstanding: $ 0.00 Conditions No Degradation of Water Quality Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project.X Erosion Protection Prior to final approval, all upland areas disturbed or newly created by constnrction activities shall be seeded,vegetated or given an equivalent type of erosion protection(silt fencing or straw matting), x Temporary Erosion Control Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established.X SITE PLAN Approved per dimonsions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X Floodplain without BFE 1. First habitable floor must be elevated at least 2 feet-above-surrounding grade. 2.Mobile homes must be securely anchored.3.,'Foundation or skirting vents must be within 1 foot of grade, 4,An elevation certificate must be completed by a licenced land surveyor certifying the as-built elevation of the first floor to the nearest 10th of a foot prior to final inspection.X RCW 18.27 - ^- http://www.co.mason.wa.us/pe--nnits/Mai-n.php?caseno=BLD2007-01025&case-type=BLD 7111/2007 ADAIR HOMES,INC. 2303 93rd Ave.SW I P I Olympia,Washington 98512 Phone:360-352-7641 Fax:360-943-0701 0 Practical Homes for Practical People! March 19, 2007 Mason County Department of Community Development P.O. Box 186 Shelton, WA 98584 Dear Official, I am applying for the Building Permit for Vincelle Durand. Her site is located at 953 Jensen Rd, Shelton, WA 98584. Included in this application are plot plans, site plans, (3) full sets of plans, environmental permit forms, and the application fee of$410.19. The water adequacy form will be turned in by the homeowner. Please contact me at (360) 352-8571 if you have any questions or if there is anything missing. Thank you, RECEIVED MAR 21 2007� Aura Chamburs 426 W! CEDAR ST, Branch Administrator Adair/Olympia ®FHB ADAIR HOMES,INC. AURORA BEND CALDWELL CRESWELL MEDFORD OLYMPIA WOODLAND a� OR:CCB#593 WA:ADAIRH`262RZ ID: RCE-2703 ,,,,me-Id-A11.11,11- www.adairhomes.com MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT WSEC/VIAQ Compliance Application Owner:y bu,t y, D kuTelephone: v-� Parcel#: 32 3 222 Type of project ( New Residence ( )Addition ( ) Remodel Total Sq. Ft. 15 Floor: i O2 26,1floor: Heated Basement: of heated area:: Heating System Type: • Electric wall heater O Electric Central Furnace O LPG Furnace O Heat Pump with electric furnace O Heat pump with as furnace O Boiler, specify fuel type: O Other: Specify Z Glazing O Prescriptive Option see reverse side circle one: 1 II IV Percentage: Compliance Method O Component Performance , Chapter 5— Calculation worksheets required Check one:: O Systems analysis, Chapter 4 O Whole House Ventilation system O Whole House Ventilation using a Heat Ventilation using exhaust fans&window or wall fresh air Recovery Ventilation System (VIAQ 303.4.4) System vents (VIAQ 303.4.1) Check one O Whole House Ventilation Integrated O Whole House Ventilation using an inline with a Forced Air System (VIAQ 303.4.2) supply fan. VIAQ 303.4.3) Window & Door Schedule (if needed, attach an additional sheet) Total Manufacturer Roomllocation U-Factor Size Quantity Square Feet Windows: Windows: Total Sq. ft. Doors: Doors: Total Sq. Ft Total window and door area Total window & door area /(divided by)total sq.ft of heated area = %of glazing i MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON (360) 427-9670 BELFAIR(360)275-4467 Elma (360)482-5269 FAx: (360) 427-7798 WEB SITE: www.co.mason.wa.us P.O. Box 186, SHELTON 98584 2004 Washington State Energy Code (WSEC) 2003 Ventilation and Indoor Air Quality Code (VIAQ) effective July 1, 2004 Code Compliance Application Form The following information will be required for the WSEC and VIAQ plan review: 1. Complete the Washington State Energy Code/Ventilation and Indoor Air Quality Code (WSEC/VIAQ)application located on the reverse side. 2. Complete the window and door schedule on the reverse side. Include all windows, skylights, sliding glass doors, french doors and any door that is more than 50% glass. Use rough opening dimensions of the windows and doors. Information about the U-factor of the window will also help to expedite the energy code review. If you are complying with the WSEC by prescriptive path and are using the area weighted average method you must include your calculations. 3. On your building plans note the location and fuel type of water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of insulation proposed for walls, floors, ceilings and slabs, 4. Questions? Call Mason County Community Development at (360) 427-9670 ext. 352. Additional WSEC and VIAQ compliance information is available on the internet at: http://www.energy.wsu.edu/code/ Prescriptive Requirements °'for Group R Occupancy Climate Zone 1, Table 6-1 Glazing Glazing Ll-factor Door Wall Wall Wall 4 Area %of U- Vaulted Above interior4 exterior a Slab Option Floor „ a Ceiling Ceiling Grade below Below Floor on 10 Vertical Overhead Factor 2 12 grade Grade Grade I 12% .35 .58 .20 R-38 R-30 R-15 R-15 R-10 R-30 R-10 II* 15%* .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 IV Unlimited Single Family Res .40 .58 .20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 (R-3)Only *Reference Case/Call (360)427-9670 ext. 352 for footnote information. Log &solid timber wall with a min.avg.thickness of 3.5"are exempt from the above grade wall insulation requirements. Mason County Map Output Page Page 1 of 1 Mason County Ma �Q F� v a� �0 ti aka U <M N mac, `b t { o 2sstt DISCLAIMER AND LIMITATION OF LIABILITY: The data used to make this map have been tested for accuracy,and every effort has been made to ensure that these data are timely,accurate and reliable.However,Mason County LWEND makes no guarantee or warranty to its accuracy as to labeling,dimensions,or placement or location of any map features contained herein.The boundaries depicted by these data are . '-''Roaeta F.okat Ltittttls approximate,and are not necessarily accurate to surveying or engineering standards,and are intended for informational purposes only.Mason County does not assume any legal liability Hifl aSdS City of 8helWn or responsibility arising from the use of this map in a manner not intended by Mason County. In no event shall Mason County be liable for direct,indirect,incidental,consequential, ram+RROM sttowns Cmity 8ftndery JONR) special,or tort damages of any kind,including,but not limited to,loss of anticipated profits r Patro6la Comrnisaton Districts benefits arising from use of or reliance on the information contained herein t... r ®2006-Mason County sections Lakes 415 N.Sixth Street r'-j Tomnshos Puget Sage 3 MOW Lakes Shelton,WA 98584 http://mapmason.co.mason.wa.us/servlet/com.esri.esrimap.Esrimap?ServiceName=amason... 2/21/2007 MASON COUNTY PERMIT NO.Jan Q �1 BUILDING PERMIT APPLICATION �.,� 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 -TA VhwL4-) On the web www.co.mason.wa.us APPLICA T INFO MATI I CONTRACTOR INFORMATION Owner VJ�VV'Q Vj. Company Name �. Mailin Address �. LO r Gi' Mailin Address � City Sta:�eyy� Zip Code ,'- City State �—Zip Code 01Z Phone 0' :WOther Ph. Phone 12Q-,WZ_ Other Ph. Lien/Title Holder Contractor Reg. # H 2- xp, E mail address E Mail Address Drivers Lic.# DOB Drivers Lic. # DOB EPTIC ATER SYSTEM INFORMATION - Connect to New Septic k Existing Septic Connect t Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No, Fire District Legal Description "1.5. , LOT-- Site Address (Please include street name, street n tuber and ity) Y q Directions to site ._t3L�OLf't 0.f0 Doil ID I tum rr�jhe ail w e Will timber be cut and sold in parcel preparation? Yes Qp Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasor•al Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Ye TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE U SEASONAL ❑ Use of Building-�V Describe Work aL; .�1 i� -lat�.r 14 ,No. of Bedrooms —No. of Bathrooms_I Square Footage- 1 st Floor i "7 OZ 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage_�H_Q Attached X_Detached Carport Attached Detached MANUFACTURED HOIIA FORM N - Make Model Year Length Width No. of Bedrooms No. of Bathrooms Type of Heat —Bert urc e Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I dec are that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as prc Dosed in the application.I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONT NUAT N Oi'WORK IS BY MEANS OF A PROGRESS INSPECTION X Date: /I�1y7 Owner/Owners Repre:;entative/ ontractor (indicate which one) FOR OFFICIAL USE BI=YOND THIS POINT Accepted by424WU Date -d DEPARTMENTAL REVII:=W APPROVED DENIED NOTES Building Department Planning Department r�j Environmental Health Department) Public Works Department Fire Marshal It> FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee /0 4. 5b Planning Review Fee Mechanical & Base fee . D Other Wood/Gas/Pellet Stove free State Fee • � Violation Fee /V0 ��//; Pre-Paid at Submittal Valuation $ j 27 ' �O TOTAL FEES MASON COUNTY PERMIT NO.VJ;?b6j -06d�_9 PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670-Belfair(360)275-4467- Elma(360)482-5269 On the web www.co.mason.wa.us APPLICA TINFORMATIO CONTRACTOR INFQRMATIO 'v,►�,+� Owner 1 e- Company Name Mailin ddre Mailin Address City Stated Zip Code �-� City _State —Zip Code Phone Other Ph. Phone A OtheL Ph. Lien/Title Holder Contractor Reg. # ADA I" *22RAIExp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No ' 2226I CIO 9-f Fire District Legal Description Site Address(Please include street na e me, street number d city) 5 kd D' ctions t site S Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream__)L—Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units- 1 st Flool-X_ 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric A LPG_Natural Gas_Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer _ Gas Outlets Kithen Sinks I Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF F CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTIONj X �Pf 44L' Date: Owner/Owners Representative/ ontractor (indicate which one) FOR OFFICIAL USE BEYQND.THIS POINT Accepted by Planning Pd Ck# Dat n:I—Bld Pd Receipt No. DEPARTME TAL REVIEW APPROVED DENIED NOTES Building Department Occ Group T e Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES