HomeMy WebLinkAboutSPI2006-00279 - SPI Inspections - 11/7/2006 oN.srATF MASON COUNTY
o P� A C N DEPARTMENT OF COMMUNITY DEVELOPMENT
o
> s N Planning Division
Y ti P 0 Box 279,Shelton,WA 98584
(360)427-9670
1864
Site Inspection
November 07, 2006
TO BE KEPT IN THE
MIKE HEALY PARCEL FILE
2938 LIMITED LANE NW SUITE C-1
OLYMPIA WA 98502
Case No.: SP12006-00279 1-1 -2_ T-
Parcel No.: 321322290053
Project Description: Feasibility to locate home and septic on parcel.
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI)was performed on your property. Below you
will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands must
be included in your specific proposal; these setbacks are included as part of the comments listed
below.
This information is based on County and State regulations as they exist to date. These regulations
may change and may affect the requirements for development of the subject property.
Please contact me at(360) 427-9670, ext. 365 if you have questions.
Sincerely,
Allan Borden
Land Use Planner
Mason County Planning Department
11/7/2006 1 of 3 SP12006-00279
Site Inspection
11/7/2006 Case No.: SP12006-00279
Comments:
Pre-inspection for Mike Healy on October 25, 2006:
The purpose of this inspection was to determine applicability of
planning development regulations to proposed new residence.
The subject parcel is located along Johns Creek, a type 1 stream
in an area of slightly curved creek alignment. The property has a
slight slope from the driveway northeast towards the creek area;
much of the creek buffer has been cleared long ago except within
20 to 40 feet of the edge of the creek. An existing home is
located on both this lot and the one to the south, as viewed from
the drive and following the property corners.
Mason County Development Regulations: The zone designation
for the site is Rural Residential 5. Standard building setbacks for
this zone are a 25 foot front yard setback, and 20 foot side and
rear yard setback (lot line setbacks). These setbacks are
measured from structures or projections greater than 30 inches
above grade, such as roof overhangs or gutters, balconies, stairs,
decks, fuel tanks, heat pumps, etc.
Mason County Resource Ordinance: The Type 1 stream is a
perennial water of significant volume and known fish bearing
capability and falls under the jurisdiction of the Fish and Wildlife
Habitat Conservation Areas Chapter (17.01.110) of the Mason
County Resource Ordinance. The provisions of this Ordinance
establish certain buffers and building setback requirements for
streams; for a type 1 stream there is a 150-foot vegetation buffer
and a 15 foot building setback, for a total of 165 feet from the
channel migration zone (CMZ). In accordance with the Resource
Ordinance, buffers are to be retained in their natural condition.
New residential development is not permitted within Fish and
Wildlife Habitat Conservation areas or its buffers, except for as
approved through a variance or reasonable use exception review
process. A copy of the Fish and Wildlife Habitat Conservation
Areas chapter is available, including details on the contents of an
HMP and the variance public review procedure (if needed).
Staff made measurements from the location for the septic system
and residence (in relation to the existing test holes) to the stream
bank: the test hole closest to the creek at the north was a 170 foot
distance to the creek (40 foot area of native buffer and 130 feet of
maintained yard) as it flows to the east; the test hole farthest from
the creek was 230 feet distant. There was available area (90 feet
deep) where the residence footprint could be moved to meet the
proper stream setback as well as the front yard 25-foot setback.
11/7/2006 2 of 3 SP12006-00279
Site Inspection
11/7/2006 Case No.: SP12006-00279
Floodplain Standards: According to Flood Insurance Rate Map
No. 530115 0200 C (May 1988), the subject property is within the
Zone A 100-year floodplain. Mason County development
standards allows residential construction as long as the level of
the first residential floor is 2 (two) feet above surrounding grade
and the provision of vent panels to allow passage of possible
floodwaters through the foundation at such flood events. These
are typical conditions added to a building permit for structures
constructed in a floodplain.
Aquifer Recharge Area Standards: As noted on Mason County
maps, the property lies in the Class II aquifer recharge area in the
vicinity of Shelton. An aquifer notification statement must be
recorded with the Auditor's Office as a condition of development
permits issued by the county within the aquifer recharge areas.
The fact that an existing residence is situated on lots B and C can
be resolved by adjusting the common boundary line or by
removing the residence from one of the lots. A side yard setback
that is greater than 5 feet from the residence to the new property
line could be proposed.
No other critical areas such as steep slopes were identified on site
that would have an impact on future development.
General process: Future site development must include a site
plan, reflecting all of these setbacks from property lines, slopes
and stream, will be needed for the building permit application
submittal.
Specific standards for future development contained in County
Codes may be found at the County website address
http://www.co.mason.wa.us. If you have any questions please
feel free to call. Thank you.
11/7/2006 3 of 3 SP12006-00279
czC)
MASON COUNTY
PLANNING DEPT. PRE-INSPECTION APPLICATION �C�y
PLEASE PRINT $205.00 Fee Required
1. Owner: Cogora�oN Applicant: tlg4k. Heat,4
Site Address: 953 F, Oe.Nse>,1 R -,SkJ-6,j Applicant Address: 2939 Li e. NW, ve C
Owner Address: Nby,4 e C-I City: 0(V My2',a St-W _Zip 16 4z
City: 01�w1111 c, St��Zip 9U So 2_ Phone:(360 ) "7 D -,7 o day
Phone:(36e ) '-7oq_-jg06 day (360) 9o- 46 7 6
Phone: 36n -9 6 evening Planner:
Email Address:_W1I<Q-@ k 0411 mor+aaae-. Cowl SMP Co A. 11
l Typ of Use )
Water Body
2. Parcel No. 3Z 132 - 22 _ 6 d D 53
Parcel No. - -
Legal Description: 'T ra 4 C 0 Sk,4Sbd;U1'S1"0 ry AJ1, 8.0 eazxe d 11 gO of
A e No• 377 9 3 51 a yor-fi o,J o NW`Iq o N k)l�/ o f Secha v 3 Z,�,�,,,�� 2 t N.lPa.�3/vPlf �j
3. Purpose of Pre-Inspection
S o - oo a is
e A,'1 C. 1 W71 5 'e"4
1. C is
4. Use of building:
5. Do any of the following exist on or adjacent to property?: slope( ) saltwater( ) lake( ) river(
pond( ) wetland(+mil seasonal runoff( ) other( ) stream( ) seasonal creek
Directions to Site: Vi.
rj Ot oj F, k4l ,
L.f C is mgk,4 Y.' Star
s ve
If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the original
application. Pre-inspection reports remain valid only until development changes occur in the vicinity which affect the lot
evaluated in this inspection, or the laws regulating development of the site change after the time of inspection.
Applicant Signature: - Date: /Z ZGo
If you would like to be on site during inspection,please check here: ( )
Return application to: Department of Community Development,Planning Division
P.O.Box 186
Shelton,WA 98584
(360)427-9670
Please include a$205.00 check or money order payable to Mason County Treasurer
When completed, this form becomes part of the parcel file.
FOR OFFICE USE ONLY: Accepted by: Date: n
MORE ON BACK SIDE
IAPLANNING\PAC\PRE-INSPECTION Revised: 01/17/06
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes,wetlands, etc.).,
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEOUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
CJ a�,N�S �rcet✓
30
y
Pere ED ro p�seG b Un[k N) I�-
es D
IOGQ�ON
o�- S��IiLS�S{�� Ea-S�.vri�..f aGi oFt
U ( p
Departmental Review
(For Office Use Only)
Planning Department Findings:
l kwm-1 J M&A 1 lawd 6 L'e�-Y�
MMM
�:
Please illustrate below the proposed building site in relation to critical areas (slopes, streams, lakes, wetlands, etc.)
existing improvements, as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
eye a��
G Ga
F�rG ED rapoSe.GQ b�I�uN� �''
t-�les334-
l�
G
I-
OGA.�ON
o� S�pliC S�S�� Ea��� °� ' OFt•
d be S ►�1 a I t 10�1 ►� wio VP
J
p
Departmental Review
(For Office Use Only)
Planning Department artment Findin s:
61"0 . 5PK Mhw�
c �o~0 M&A, Wd 0 tjL�-�b
�l
NORTHWEST QUARTER (NW4) OF SECTION (32) , TOWNSHIP (21) NORTH,
r RANGE (3) WEST, W.M.
RFC 244 FR. 63
3'77935
Short Plat
Approved_..._6 �14.
Planning Director.
SELLER: STELLA L. WINTER
F
1428 Olympic Highway
"IV South
Shelton, Washington
98584
h x
,U
x �
.Y
,/G \
P
IC�`
n J
SCALE: 1" = 100'
i \\
\ \
No. 44805
• 1
These Lots shall not be used for on-Site sewage dispos or,
dwelling structures without prior written approval of the 1
Mason Environmental Health Department Officer.
.hle:.••"jam' �
I•