Loading...
HomeMy WebLinkAboutBLD1232 Storage - BLD Permit / Conditions - 8/9/1991 g0031 Shorelines: Plunnb ing: Setback: Mechanical: Special Interior: Conditions: FINAL: Mobile Home: Smoke Detector: Remarks:rA, lF,,yr noting t, Y nl' i-i Setback: i fvR fv� li.vG 1 Foundation Walls: Framing: Fireplace: Wood Stove: TYPE STORAGE Permit N0.28776 No. Floors Sq Ftg 1232 Owner Robert Herr TeL588-6493 Date 8 9 91 Address 9119 109 St SW Tacoma 98498 Zip Contractor Same Address 1P Legal De scription 34 21 3 Direction to project site Hwy 3 N to Mason L & go to top of Bill, turn R on to 1/4 mi. , turn L on dirt road. Prop�b PlL ing c anic�—Sewer woo tove Fireplace Deck age arport Basement soft Other STRUCTURE OVERHANG MUST BE A MINIUM OF 5' FROM PROPERTY LINE. STRUCTURE SHALL NOT BE OCCUPIED. L_� the, 4� ►, cl e r Date Checklist Prepared IC /2 MASON COUNTY BUILDING DEPARTMENT PLAN REVIEWER AND INSPECTOR CHECKLIST 1991 WSEC AND V&IAQ CODE COMPLIANCE 22134 - `fl- oop30 Permit Number Address Sq. Ft.—LZ22-.5 pl�' Name on Permit PE t� ob Contractor/Phone # Y27- /yfo l Compliance Method: (X Prescriptive l� (Option) ( ) Component O Systems Analysis e/ec{K� HQ-+- 12°Yo— ►'1efa1 Do orb (ti1A1N Q 14.6 Date 01 Insp. Rev. FOUNDATION —i L'PS� ( ) ( ) Slab: R- (Ill.foundation down to frostline/slab bouom:or interior 24"top of slab&horizontal. adtant tin r entire.) ( ) ( ) Below grade exterior wall insulation: R- ( ) ( �Craw space ventilation: - q i:' (I sq.ft.�150 sq.h.floor area-cross vented) e FRAMING ( 'S=dard ( ) Intermediate ( ) Advanced Woodstoves and/or fireplaces: (6 sq.inches combustion air supply duct with damper direct to firebox.) Standard air seal: (Bottom platc/subfloor,rimjoist/mudsill.window/door frames,penetrations condition to non-condition.) Attic ventilation (1 sq.ft.LFA/150 sq.ft.ailing area) Spot exhaust fans. (4"exhaust-banh/laundry 50 cfm @ .25 WG:kitchen 100 cfm @.25 WG. Vented out with dampers.) ( ) ( -rFresh air ventilation: Available to all habitable rooms. Installed and operational. (Integrated forced air,windows,wall ports.) ,.,,,,. .+ .�5 wG Whole house exhaust fan: J CfIn(Intermittent system manual&auto controfs/sone less than or=to 1S at.I WG) INSULATION Attic baffles installed to deflect incoming air(Rigid material resistant to wind-driven moisture,extend 12"above loose fill or 6" above bait insulation) Mechanical ventilation ducts R-4(Exhaust in unconditioned space&supply in conditioned space.) insulation (above grade) R- ) 6T _ (Bata face stapled) ( ) ( ) Wall insulation (below grade - interior) R- (Batts face stapled) Vapor retarders on walls (Faced ban,or a mil poly or perm,paint.-Circle one) Rim joist(Insulated with vapor retarder-rigid foam and caulked or 4 mil poly.) Vaulted ceiling insulation R- 30 (Vapor retarder& 1"air apse) / FINAL �( Floor insulation R- _(Substanual contact w/surface,supports less than or=to 24"OC',not blocking vents.) ( ) ( -�r`Ventilation system is operational (spot,whole house,fresh air to all habitable rooms.) ( ) ( ) HVAC ducts in unconditioned areas R-8 (Joints sealed) ( ) ( -)---Pipe insulation R-3 (Hot and cold lines in unconditioned areas-smite or recirc.see Table 5-12). ( ) ( -Y___SHW heaters: (�IAECA label,separate power or gas shut-off,on R-10 pad if electric in unconditioned or on concrete.) Heating system type: I t' 4 - LJt~ 1 Heat pump, list size. HS PF, and COP. Indoor Outdoor Radon monitor on site with instructions. No. Leh by Inspector ( ) ( ) Ther=Stat: (Heat range 55-75:AC 70-35;both 55-35. Backup heat controls(lockout)present simultaneous operation of primary system) ( ) 'Solid fuel appls.: (Glassimetal tight-fitting doors;dir.comb.air source,or 4"dies.dampered,iodir.source for existing coast.) ( ) ( f�Ground cover: (6 mil black polyethylene or approved equal lapped 12"at joints.extending to foundation wall.) Penetrations (All exterior wall and ceiling penetrations sealed to drywall-plumbing,exposed beams.wall receptacles,fans,recessed lights.) ( ) (ii___­Ceiling Insulation R- (Insulate&weatherstrip access.baffle to prevent spillover-no cardboard) ( ) ( ) Vapor retarder paint. * Less than or equal to 24" on center is code. 'rwine is recommended or supports at 12" on center. �SlZcc d Ae-ki � �S - � /ec . 14eu-t w� /2-`', �j4z/- - J O - s a �a �►S a� wl Wvo�t �d�rs — n v;r:n . v0 6).r y GLAZING `' v3 /ti.rs Plan Reviewer - Fill out this glazing section or attvh a window schedule to this checklist. jm-pector- Verify window information during field inspections. Include skylights. ;lass doors and all usher;lazing on this form. Use rough opening area for calculations. Size Quantity Area Sq. Ft. U-Value Manufacturer Rev. Insp. o S N �O 12 . ti s/ 7. i o �4er r 2 � C� S I-!• i3.7S C 3 0 CSm 7 I I 0 3/ � b s I.7S S Total glazing area: Total conditioned area: 172-2 S Percentage glazing: . 9i)- Verified: DOORS Plan Reviewer-List opaque doors by type (solid core, insulated,etc.)quantity, U-value,and manufacturer. Impector- Verify door information during field inspection. Type/Quantity U-Value Manufacturer Rev. Insp. 3 i or p a� CW Signature of Building Inspector: Date of Final Inspection: 1991 WASHINGTON STATE ENERGY CODE AND VENTILATION AND INDOOR AIR QUALITY CODE PRESCRIPTIVE PATHS OTHER FUELS (GAS, OIL, HEAT PUMP) HVAC' Gazing war war lrltt War ge Slab' Equip. x Floor Glazing Doors Vaulted Above Babes Betbw an Option Ef5c- Area l-Value lJ-V"a Ceii CaWV3 Grade Grade Grade Floor Grade 1. Med. 10% 0.70 0.40 R-30 R-30 R-15 R-15 R-10 R-19 R-10 il. MeC. 12% 0.65 0.40 R-30 X30 R-15 R-15 R-10 R119 R-10 III. High 21 x 0.75 0.40 R130 R•30 R I9 R49 R-10 R-19 R-10 tl/« ,;, 21% 3 r5.v,,b;O R•7Q 3t�7�; [ max, # l tQ... f ,<�, 2Q Reference cue V. law 21 x 0.60 0.40 R•30 R30 R4 Rag R-10 R-19 R-10 VI.' Meld. 25% 0.50 0.40 R-38 R-30 R49 RID R-10 R-25 R-10 Vu' Mad. 30% 0.45 0.40 R-30 R•30 R 19 R49 R-10 R-25 R-10 1 .Yimewaan npawrwrwm for arbh option foxed. Fr aorrw*d a proporA doomr hr S Hoes over wad woom or woo.ad to rrowr w mnddom. a plaarp row to the oordaard Mloor tea d I M/thaw ow"wd1 al d tire laprrenwm at Ow ZI%ptiarp opbort for NpMarl Ptvgwad deargw vA+d tarwtct i Kwluwad almb parrrrer.wtriebon thaw t>..wtr rea.t.nl rrtatrul,mr1lAaGwed trust rre gnfio mmrw rrwran of At limed dipoon above,rtwy caioulam conpirrar for b rdendad vK and rrmalled aoowdwV lo manulamire/a apedlcabom. Sae by CAmpare♦or S at that code. sear"6024. 2 liabuiranrra avOsw b aw oa.frrpa ammnx a.rpia rahw or post vowed oaiiga. 7 Theme aptom Mal be appfioble to bu.WaVe Ve.a then&."m aeon... 'A&V dertoar Adwnod Franwd C 619. • This wall iemuatrrt rewrr.wm d.rwa..R-19 wow awarf rwulabon pia A-S loam" 3 Rowrenwa appl ombb only to-Via talk a pest vauied o--Va mmme to 4 Below grade waft dad be rm"ated edw on em aetard to a nwwn.r level d iZ 9 Um,.w WVAC Ewrpewtt dficmoc,raou.anwnt. Loan donate.n AAJE el 0.74. 1 Q r a ova.sorter b true manes level r.wrr sees.grads. EAtmr w ntuirlOm Use do mom an AFUE al COL. m Q NVK done a an AFUE al ail W w babes pre6a stela Mall b.•wrr worms rrwwtal,rrwrwdaored for he assisted was.and memaabd aaow"M M nrrw4d.er•a a0emwimaewa Sea mocnmt 4= ELECTRIC RESISTANCE HEAT Glazing will war w war exit slaw x Floor Glazing Doors Vaulted Above Bwm Babes an Option Arse U-Value l-Value Cafirig' C &-qA Glade Grade Grade Floor Grade l 10% 0.46 0.40 R38 Rao R-21 R-21 R•10 R-30 R-10 IL 12% 0.43 020 R38 R30 R•19 R-19 R•10 R-30 X10 IQ. 12% 0.40 0.40 R-38 R-30 R-21 R-21 R110 R-30 R-10 a "' % ia0 #1C, Retarsrice case V. 18% 0.39 02o R38 Rao R-21 R•21 R-10 Rao R-10 VI. 21% 0.36 020 R-38 R•30 R•21 R-21 R-io R130 R-10 Val.' 25% 0135 020 R-38 R30 R-19+R-5e X21 R-10 R-30 R-10 Vln.' Sox 0.32 0.20 R-38 R-30 R•19+A-5a R-21 R•10 R-30 R-10 1 Me w am rawraw+wm Oar each spoon bast For aeande.d a oropowed daarpn has S Flom eves w.rl"mom or eapsed to r+owa r adtd4rw a giaap rare b des orrdraared Mbar area d 19%d OWA Doody—all c Ise rawrenw as el nrm 21%gaaarq court for hy+rrl. Pravoe.d des".rre11 earr+ot i Ragtrd Web ow r rwtaratra Maw be a imam reasunt mammal rrwr wadwod "ram Vw odic rwmtmrrwrb d a Wood mom above,may aabule"mnpivtaa for an wowalla l we,aw/weamltd.00moo-9 am nwwwadwrelo apacdcAbona. Sae by CAopewe 4 or 6 d the modm. semen 4024 2 Rewrrwrwtr aedse to v eatinQa•op er'VM caller r pwt vauaed oadir.pa 7 Those coom Maw be appioble to btakimn tau than Owes abnea. 'AN dormant AAvenowd F-real Cedr. 4 That ww rawaaot mwramwr derw.ea FL 19 wow cow.omm",on okra A-S for++ 3 Rewren- aRmcobia a"to mrgit renar or pat reamed o-w9m. anemfrq. ♦ Bebw groom web MW be ommAt hd odP w on tfte master to a mwwra.n bvei of P, Ia.or on the aeerrr to Me anew bid m wdr above presto Exteror■wt wtrdn nmawed on brides praOe weft MM be a wa rra ter mea nw .ww.m %Aact red for b.rtrrra.d rs,rW rwtalrrd adcon"to Ott mwrtAaaUoW$apecd+utrra See robon 6022. NAME ON PERMIT WINDOW SCHEDULE WINDOWS Brand Model U-Value Quant. Size Area (Sq. Ft) 1A 'IF 6 / All X3�6 S icy/ GAser•" e�i�%rrce �ia�c pi 6 Yo a.r- w -, TOTAL WINDOW AREA .2 //. 4— SKYLIGHTS Q/esys�ty� /a Zt7 Brand /V0//P/ Model U-Value Quant. Size Area (Sq. Ft) TOTAL SKYLIGHT AREA DOORS Brand Model U-Value Quant . Size Area (Sq. Ft) Z1,fN1411a/J'Ace/ e TOTAL DOOR AREA 4/p MASON COUNTY BUILDING DEPARTMENT 1991 WASHINGTON STATE ENERGY CODE AND VENTILATION AND INDOOR AIR QUALITY CODE RESIDENTIAL REQUIREMENTS (NEW CONSTRUCTION, ADDITIONS, & REMODELS) THE PROCESSING OF YOUR APPLICATION CAN BE EXPEDITED IF YOU PROVIDE COMPLETE AND DETAILED INFORMATION. YOU ARE ENCOURAGED TO COMPLY TO THE 1991 WSEC BY UTILIZING THE APPROPRIATE PRESCRIPTIVE PATH FOR YOUR PROJECT. THIS WILL ALSO HELP EXPEDITE MATTERS. THE FOLLOWING INFORMATION MUST BE PROVIDED: 1) A complete window schedule must be submitted with your WSEC compliance information, even if a window schedule is included on your building plans. Note that sliding glass doors (patio), french doors, and any door with 50% or more glass in it is considered a window with the area (sq.ft.) being the entire units rough opening dimensions. Any windows in doors (less than 50% of area) must be taken out of the door area and put into the window area on the schedule. This window schedule must minimally show the dimensions of the rough openings of each window, the model (casement, horizontal slider, single hung, awning, picture, etc...), and the units tested U-value. 2) If you are complying to the WSEC by prescriptive path and are using the area weighted averaging method you must include your calculations (worksheet). 3) Indicate type of hot water heater, location of exhaust fans (bathrooms, laundry, kitchen), the location of your whole house fan, and all insulation levels (walls, floors, ceilings, and slab) on your building plans. 4) Indicate how you will comply with the re uirement for introducing fresh air to each habitable room on your building plans window frame env n4; through the wall ports, or an integrated system with your furnace). 5) If your home is 2,000 square feet or less, and using electric resistance heating (excluding heat pumps) be sure to put your Social Security Number or Federal D:)# on this form so that you can receive the $900.00 "Payment to Owner at Time of Construction" rebate from your service utility. Using electric heating or a heat pump in your home= You may want to talk to your service utility regarding Long Term Super Good Cents incentives. Call PUD#3 at 426-0777 or PUD#1 at 877-5249. If you need assistance in showing compliance to the WSEC please ask for the brochure "What You Need to Know to Meet the Energy Code"; call the State Energy Office at 1-800-235-8248; or call and make an appointment with Dan Fitchitt of the Mason County Building Department at 427-9670. MASON COUNTY BUILDING DEPARTMENT 1991 WASBINGTON STATE ENERGY CODE AND VENTILATION AND INDOOR AIR QUALITY CODE COMPLIANCE INFORMATION TYPE OF PROJECT: (t-YKEW RESIDENCE O ADDITION O REMODEL AREA (SQ.FT.) 1ST FLOOR V J1' 2ND FLOOR 7,7j BASEMENT TOTAL SQUARE FOOTAGE OF CONDITIONED AREA / cr? COMPLIANCE METHOD: (WfRESCRIPTIVE PATH — circle option — I II III LN/' V VI VII VIII Glazing percentage f,Z . / `/r (total glazing area divided by total conditioned area) (� COMPONENT PERFORMANCE — Chapter 5 — attach documentation and worksheets ( ) SYSTEMS ANALYSIS — WATTSUN 5.2 — attach documentation and worksheets HEATING SYSTEM: ELECTRIC RESISTANCE ( ) Electric Central Furnace ('eilic Wall Heaters ( ) Baseboard Units ( ) Radiant Panels ( ) Other ( ) 2,000 sq.ft. or less — Name SS or FED.ID# OTHER FUELS ( ) Heat Pump ( ) Gas Furnace ( ) Oil Furnace (q-06ther ;i y,�,�ee T>lJ*^T ( ) Boiler System (indicate type) Make C�i Model A - 1l I,�f�;' �i^ Size AFUE HSPF YENTELATION SYSTEM: (�ot and Whole House ( ) Central Ducted System O Integrated with Furnace ( ) Heat Recovery System (air to air heat exchanger — heat recovery heat pump) GENERAL NOTES: Your building plans should indicate certain compliance measures: framing to be used (standard, toter rf iaate, advanced); type of vapor barriers being used; location of furnaces, hot water tanks and o er equipment; location of solid fuel burning appliances, fireplaces and their combustion air duct runs; and termination points of exhaust ventilation fans.