Loading...
HomeMy WebLinkAboutBLD2022-01261 Cancelled MFG Home - BLD Inspections - 12/4/2024 CANCELLED INSPECTION CARD 4p Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2022-01261 PROJECT ADDRESS 800 E WOOD LN SHELTON, WA 98584 PARCEL# 320215602041 PROJECT DESCRIPTION NEW MFG HOME OWNER SHAWN GREEN ADDRESS 8312 SIERRA DR PHONE 206-423-9650 CONTRACTOR ADDRESS PHONE CONTRACTOR LICENSE LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments Setback Inspection Connection has been verified by Footing Inspection BLD-Final Inspection Set-Up Inspection Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FBLD2022-01261 MANUFACTURED HOMEESCRIPTION: NEW MFG HOME ISSUED: 01/03/2023 ESS: 800 E WOOD LN SHELTON EXPIRES: 07/02/2023 PARCEL: 320215602041 CANCELLED APPLICANT: GREEN,SHAWN OWNER: SHAWN GREEN 8312 SIERRA DR 8312 SIERRA DR EDMONDS,WA98026 EDMONDS,WA98026 206-423-9650 FEES: Paid Due Technology Surcharge $11.00 $0.00 Modular/Manufactured Home $275.00 $0.00 Fee-2nd half collected at ready to issue Modular/Manufactured Home $275.00 $0.00 Fee- 1st half collected at submittal Building Plan Review/Change of $125.00 $0.00 Use-Onsite Sewage Planning Review Fee $240.00 $0.00 State Fee-Residential $6.50 $0.00 Totals : $932.50 $0.00 REQUIRED INSPECTIONS Setback Inspection Connection has been verified by Health or Utilities Footing Inspection BLD-Final Inspection Set-Up Inspection CONDITIONS Printed by:Ariane Paysse on:01/03/2023 10:40 AM Page 1 of 5 , Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-01261 * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indicated on the plot plan. * Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 An approved Installer cerification tag shall be placed on the end of the manufactured home directly above or below the HUD certification tag or temporarily located in plain site within three feet of the home's front entry. There shall be one certification tag for each certified installer accounting for the work that each installer performed or installed. Certification number and signature of the certified installer responsible for each major part of the installation. WAC365-210 * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * REQUIRED INSPECTIONS (Footing Inspection-prior to pour(set-up manual must be on-site), Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the current fees adopted by the Mason County Building Dept., and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWN ER/CONTRACTOR(indicate which) Printed by:Ariane Paysse on:01/03/2023 10:40 AM Page 2 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-01261 * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All property lines shall be clearly identified at the time of foundation inspection. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. * The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M. Support configuration shall be clearly marked in the installation instructions. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. Printed by:Ariane Paysse on:01/03/2023 10:40 AM Page 3 of 5 , Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-01261 * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (NCSBCS/ANSI A225.1). * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.)Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.)No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. * PLANNING SETBACKS: Front: 15'ADV2022-00130 (N prop. line) Side: 5'ADV2022-00130 (W prop. line) Side: T(E prop. line) Rear: 20' (S prop. line) *Subject to EH setbacks *Measured from furthest projection of building I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: 1 6 3 Printed by:Ariane Paysse on:01/03/2023 10:40 AM Page 4 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MANUFACTURED HOME BLD2022-01261 Printed by:Ariane Paysse on:01/03/2023 10:40 AM Page 5 of 5 MASON COURN,17 ('-*Q M M UN fn S ER V IC S M :E--XT Asa �k3 zn 3'::sue 94SPECTM CARD AND CERTIFICA-M OF TO Of\ 14. Prooi New UFG HOMEa . She Address ON E VKX)D L AppkwA -0 SHAWN Contra kw UPC d PMM TYpe .A9 r x r HOW PRIM TO CALL eeaf FOR FINAL MSM �ALLCOW - ,� Wt1 .� � 3 AGAahSkS oftNt,' cimmus�' `rvicet tX tA;pare weirr st t; Apt MIN ftwulation lmo � n Sd� �' rs mar,24 N3y'4�+ h,w u 5�� !A. _..,-_.. ,.»,...,.•.��-.K..,.-,..-eta.>-. Ham OWN oft IN ARMIN woc�u►uwianr ARRM CODE CAMPLIANGE ���M� MASON COUNTY � BUILDING DEPARTMENT E � iMP�MIIsn G'�t�fP�l�t Ad��'de plat ' • , mod �60 ALMA tsl`_ t*W MA WK . �rRrart .MAN ufrALN3E R E '=.-,r7AUXT10 i /'1,44.10AL ACQVI'R10 } r t . uvRrING �'N,fPEGY� �' S 19-0 1/9 11 WATER INLET 35-2 F arnwaw PANLL Dox »oTlae J--- ^—^ 0------- ❑+ A.into»nNsw t! (- suafthcw M.rwc • L-'-t 1�1U.J �- Ame to 10 ele]Zd10 �iL-�JF• NEl AYe to»Ue 07C0 [N aor+vh—1 NITtl AwernLLnrtpl NAwAt.we ltI n � •W r[.cNCNrs. L ��_ I.reoTtwax••. �w ® OUT1. UNIT I eI1CM f0(1 tYARu I. 35-2 1/B owr. Wurtstt awa �'LE'A-GUI CONNECTI IN A!u'IYfI MA! rAOT S oM ON 11 TIPP. tell aewa(T[a, SIC. G I A I ' � I —— V I 3.POOT[Ne PM:L -� Fit"ANL Acol"] m n At Ee IYPIT F0.i9. acc INBTnLLnrlpl ® B-UNIT NnwUAL ron n[gaswi- 2 6-1 wra. FLE CT CONNECTION nt El l �o--- --a------- -----o-------o-------o; IL t 1• te_ L/2• ooOA [�_ I rlNOON � I't'_1 I/1• NOODBL@/1 210 maser wrrt 1 '-0• SAGLB 6T=�(Avi� 3:�5 C�G41�7It n �� L'�tiu•rc.Gh 28483S NOR IS FOB IOUNOATH30trAOT HOMES —m r[ru LL[I La Us. 36 IA eCL CATItN flnT lICE Y 4-• `"�Jm IMING CAPKRr OFNATWlt$(XLOBCOWACIENFILLSNN.LWtMLON EXCEED 1 WPM. PISR LAYOUT e 10f ROOF LOAD 1;tL� 1'-11 AlNO+ �"3rA�It �' �`°p `r'd /4G uttFAALBufuNG.lso rsi. Ee-9 I• A 1lDe ��wrren N. !• _ � Gy i�i'�!1 PENmcIc9cI u9U!Boca �_[���/j e 1• A [! J� r?� S� Jj Nl9 R, CTO��IMIFA•lNIM� ml 06/:9/`i .1Nq fOUNOAitONSYSTFMHAS NOT 1'•• A I _ 5 OTHER THAN ASINgr L ol TWOMEai [ 9L COND IN AB9VL 'AtUM EF? OTUDOTN6M if . SP.1E.1 C 21t9I01e3S .I MASON COUNTY BUILDING DEPARTMENT >�( Date .2 m r- m vJocd LaKttr APPROVED MASON COUNTY DCD PLANNING r SITE PLAN REQUIRED TO BE ON SITE CHANGES SUBJECT TO APPROVAL By XJ�,?/;;C Q. Date 11/09/2022 PLANNING ALL SETBACKS ARE MEASURED y FROM THE FURTHEST elkPROJECTION OF THE BUILDING PLANNING SETBACKS: AM Front:15'ADV2022-00130(N prop.line) Side:5'ADV2022-00130(W prop.line) evOh SQo.rtS ri-o f.ucl 3W W Side:T(E prop.line) Rear:20'(S prop.line) mfy. •wt¢. ` `Subject to EH setbacks ,�, CANCELLED ,� a 23 1 OL 4 EH APPROVED Rhonda Thompson 11/0212022 EH Setbacks .706 A-) DrainfieldlReserve requires 19 setback from footing.ioundations B.)Septic tank(s)requires 5'setback from all footing.loundations C)No toundationlPerimeter Drains within 30ft,downgradient of Drainfie"eserve area D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft.down gradient of Drainfield/Reserve area Site Address: Q00 �• v�lec� L�rr`t. iSkc.1-1,f,tr` Direction: Scale: BLD Permit#: Q, 1 loll - 2� li[�ce,a�.. ►�oC0A Date of Application: Owner/Applicant: pp Parcel#: 37-0 2-1 5(o02— 0 4 t -219 1-2-02.1 =- Future Homes REVIEWED FOR of Bremerton CODE COMPLIANCE MASON COUNTY r y BUILDING DEPARTMENT F0. - ' ' DC] ' ;D 1 = ulrY I op, iz 'OR Orr.ov tn* KITCHENBEDROOM#3 BATH 1o'-o"x12'-1a�oz 1 -, MASILR �_ ! r s00i vwv i ' #2 O OATH 1 BATH I W/36" DININO 1 HIGH BAR 1 wAuc,N O i U. AREA —— 0 CLOSET I } WALK-IN 1 1 OPT,CLAMOUR BATH OPf G_UE5Tj1 F f1 13 MASTER BEDROOM LIVING ROOM BEDROOM#2 p, 14'-6"X 131-0" 21'1"x 13'-0" 11'-0"X 13'-0" 1 to ENTRANCE OPT.KITCHEN ISLAND / W/42"HIGH BAR / DORMER EAGLE MODEL 284835 3 Bedroom - 2 Bath • 1,279 Square Feet A 6 Bremerton, WA 98312 360.479.4663 Mon-Sat 9a-5 Sun 12 -S \\ 4021 State Hwy i W � Brem r n, � ( p p p FWtwood www.futurehomesbremerton.com HOMES/. (r 3 39-0 !/1 1-- y ✓ �. L c G L If �••••/ WATER INLET eoetfuc PANLL DO� t•2,L��,�,, — .. ❑ -• rn• y— 1 1 i I J� L ------ �•-------❑I _—i Martefb TInYiYG fi !J LJ ItiIGYLO FM me&O 3TAYIs IY]Y WW= � AW III f0 K [r coratrter[a rtta n r SrC SYiTaGYTirlt tP • kofts Aro.awPGRwbrys G-N 1. rooi[YGb AAt ® MTN DUTL T A-OMIT cIQIY i'M c1IMPGc 1/BSPAciYWlurfvu !LL`Y—OUCH! CONMCCTION RASSP Q1 Iwo"M El10tG CMJtttp, LI —._------------ I 1 —— — I D C P[7211 ARE Rcours= rt AT SUPPORT ADS". 7AL AL MAGAe[M A-UYfS YIWAG PD A002AL- NveR. i- G-0 ! X DUCT CONNECTION I Lo--- --a-------a- ---- -----❑-------o-------E] — A s OP 0o0R I YIYDOU NOODBURX 210 Oi'-0• N-1 rwc EAGLE YS{iC S A zz is Z.a+xya r ci if ' 'Jf�X36,x$ �D. %!4� Cs CP/-: .` 28483S POST DATA i / NOTE IS FOR FOUNDATION HEADY HOMES PNPpIP TIK LAM MrATION S. am"PIE!LOA]• A A t J300 w NEARING CAPACITY OF NATUPALSOIL OR COMPACTED FILLSIW.L EQUAL DR EAOtORMPSF. PIER LAYOUT A 1 1—3ln.��3L�r X.Oy Er? 301 ROOF LOAD 6 11'-F• A sloe ``✓✓ V UTHU1 BEARING•ISO PS1. R !r-�• e C III'-IO 3/E• A 4900 Ar .ilr r�Layton N. C II-!0 T• a 3��� �Ir �� �i. PER IBC(CBC)7Ae1F lBOC2 Prs: 0 35-E 3/4• A 6000 00/70/I6 0 37'-1]//• P .SLI7a/J— •AILS FOUNDATION SYSTEM HAS NOT BEEN DESIGNED TO RESIST LOADS FROAe EXPANSIVE SOILS.ANMt ..• .a. L N'-0• A 3100 L97L[SOTHEA TNANAS INpQTEDINTHE[BCIC50 TABLE I<a.:.SCOUR,FLOODHAUFMS,WATER PRESU[E E 111-0• 1 _ ,�/���p ice, % BYTY[NDQRMVEACnDryMNDSPEEDLREFFECIS.FRCSTAETIOR HIGHGROUNDWATERORMEN 'LNPTT PIES IMD IS CON11M19 IN 1UIOLA ANWL (;� zo �, (,Q 'NATURALEVD?NOTUSTEDONTHEASRINPTIOIIS IIRGMIX& t JIST M'EEirALLTXRREfjr Jt�SH C�iCt�i sT'ATE CODES CANCELLED :'tl, ;7C a�F 'Se' ..* rL�aC ^"'°' �•� rEN .fix YA`•y w } �R.e iahDA:t'tTiT SFAL'NY'S T 3 Per'€t P,u xibe 6L CG[ri: Applicant NarnejhW4 -U, Project Titl t e: Please pro%ride a complete,detailed description of the proposed revisions to the approved plans. Please return this form to the Milason County Permit Center. t-- The following documents are reguired to be submitted with this form. Yes— No— one One set of revised plans or addendum indicating the changes. -- one set of the approved construction plans. Yes— No— (The"Red stamped" approvers site plan must be included Revisions are to be clouded with delta's clearly and accurately identified Yes No, on the revised plants or addendum. — Does the plan contain a structural, architectural or soils engineer analysis? Yes_, No_ (if yes, has the Registered ProfessionaUs approved this revision) 4 esu N0— (is a stamped and signed approval included with this request) Yes— No_ (If no engineering or other changes requiring a registered professional have been made,the plan may be approved without written consent of th&engineer or architect of record) iP Dues the proposed revision modify the footprint or location of the structurets? Yes_ NO— (if YES,is a revised site plan,with all new setback dimensions included with this request?) Yes, No— Additional information: / ,ppiicants Signature: - — J ',�T'AFF REVIEW SECTION Reviewed by: ✓� P Dean^tmc:tE Datev Ass', d Date ev ePW— F.+.xved Ron�we PSP��vod pp °6 Wgina9Valuefol i i _.. �Av4 � AddiBonai Vaivartan: E F uurap s tt � AadffiQ;.a Fees: -- Add*"Ptah Review: Additionsi$ukring Permit: � ' + Additionss PlumWng: Additions'Mec�-,anitw: e err I Other Txai Die: i'd'Jcks Page 1 of 1 A,) 0 CANCELLED 9'-8 1/4" V-9" 6-7 1/4 10'-5' 9'-6 1/2" Palm add cabinet backers 48'-0" 42'-2" 36'-J�" 3Y-3�" U21r-10t 21'-1 I1'- 5-6" 36 1/2x59 EGRESS 1T-IIr 30 1/2x 36 1/zx59 Harbor /4X52 VANITY W3o22 WG2e62 48 It9 HomeS t4el _ 'Q 953655 w1455 COPYRIGHT©2015 �ii z Palm Harbor Homes.Inc UTILITY ��W &i �h og 4'1 1 All Rights Reserved g� BEDROOM #2 y. < W ME p/yf nx MASTER BATH 107.08 SO.FT. 28'_2i �� w Plant 20-Millersburg Y p. ^ 9'-10�" DINING n z J APPR Location �N� c x KITCHEN 106.78 SOFT. = Number X a FURN / 1 k v o 3"Cab Wdl H Drawn z`ym 15'-8�" I ` ° em Date: GJA 12/8/16 32'-5t ? I \ , " . Series American Dream _ al yf 24 k----- i 'n 4 co -- -�Y 30 T BATH #2 a 3 )31 NumModber AD28482K o -- "O - 1 e --{01 y, Page I P e ts �/,' Number. 30 S&R RAG 30 L 21 Designation A i / I 11'-8d" Rev.By__ R.A.G. / I \ Revision:-REVISED I2/8/16 30 S&R / I \ 24 F!; a` MASTER BEDROOM I-26'-3k I \ LIVING ROOM �i < Approvals 168.93 SOFT. ® I \ 240.92 SOFT. n = P E u. OPTION BEDROOM /3 / 2 1 \ 3 82.61 SOFT. / \ / I \ / I \ / \ 1 r \ f23 Im 38 1 4x82 46 1 2x59 46 1 2x59 36 1 2xl2+I__ 2 36 2x80 _�---_— EGRESSx9 FS�._ g_ -- -� _-- 3rd Party 13'-9" 899Z 4'-3" in 19'-4' Default Attribute Value A Column Requirements QShear Wall Requirements(HSWC) Root Poch 3/12 Stud Length 100-2x3Q16O/C•03SPF Version 10 Flow Dead Load 10 STD Joets.2z6 C 16 O/C,#2 SPF Wind Load 15 PSF Marriage Wall Height'.102 Wind Zone 1 Roof Dead Load 15 Sidewall Height.107' SW Joist 02 SPF Floor Width.182 Exposure C Roof Live Load 30 "-Use Single Joist with Bbtk(sl ------- Floor Widm-.16r _ - _ _ Las Add'I 31 GA. Tab Max. Stud# Column Avail DSV Mina Fasteners #� Tab Max. AVE Cant Total Add'I No. Joist Strap Span Stretch Type &Size Block Load No. er L o/c Free Fixed Length PLF Length Floor Ceil' Joists Span Stretch Span Span End End 1 e wA i 1r-s'• o• , KI2.3 N 1987 1 52 150 50" 4 3" 2 19•�4" 0" 0' 0- 1 0' 0.0" 1 A N/A 1 11'-V 0" 1 N 1987 State 2 112 150 107' 2 4 3N" 7 30'-P 0' D' 0" 2.0' 0.0' 2 B N/A 1 11'3" 0" 2 N 1911 3 112 100 110" 1 7114" 1 0" 20" 0.0" 2 A NIA 1 11'3" 0" 2 N 1911 4 155 100 80" 2 3" 1 18'-0" 0' 0' 0" to, 0.0" 3 B N/A 1 8'-2" 0" 2 N 1139 3 A N/A 1 8'-7 P 2 N 1139 4 B N/A 1 6'-2" 0" 3 N 1139 4 A N/A 2 17-T 0" 2 N 2025 5 A N/A 2 12'-0" 0" 3 1 1.2x3 N 2025 6 A I N/A 1 3*4r 01' 2 1-20 N 759 CANCHLED tHarbor lm r 48'-0' V-4 3/8' I—21'-6 7/8' me s I � I v eo. 20'-2 1/8' COPYRIGHT(D2015 uw Palm Harbor Homes.Inc. -- ------------------------------------------------------------------------------------- -- _ _ _ _ Rights Reserved Plant f-13-a' 20-Millersburg w N Location: APPR. X p,ey/t28'—g' Number Drawn X 26-10 7/8' B o - Date 01-23-17 Series: American Dream WwW 40'-1 3/4' Wage. 27'-51/4' Model Orw 0 it Orw p AD28482K --------------- -41-5� ---- ------------ yy- ------------------------ - - - - - -T7 er.b Numer. ------------------------------------------- --------------------------------------- Designation: m 45-5 1/2' Cr34'- 19'-11 1/2' 11'-8 7/8' cauM oaere b °� � �+ � pee vet N EST CW WIeLNS T,3'-g 7/8'PFRRev B41'-9 3/4' T22'-7 3/8' Revision.-REVISED 12-23-16 -- -- ------------------- Approvals ------------------- PER hg -------------------------- -------------------- ----------------8'-1 3/4'---------------- 9cwrvl suawt Pi r;71 15'-6 1 4' ve+ PERssraWva voWElo wafer vtMtEel PUREW vet �_19'-3 I Room IiDr171C 9Dr" t#DOl47'-4' 30'-1 1/2' 5/8' �1V-8 7/8' I-4'-6 5/8' 3rd Party: 48'-0' 19'-8' 8• FOUNDATION LEGEND ® awM PIER PIERSHEARWALL State: =:\400 Series DoubleWides\American.Dream\AD28482Kdwq 1/23/2017 220:42 PM