Loading...
HomeMy WebLinkAboutBLD2006-02133 Final Detached Garage - BLD Permit / Conditions - 3/29/2007 Inspection Line(360)127-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2006-02133 OWNER: TONI BEACRAFT RECEIVED: 12/20/2006 CONTRACTOR: LICENSE: EXP: ISSUED: 1/8/2007 SITE ADDRESS: 800 E OLDE LYME RD SHELTON EXPIRES: 7/8/2007 PARCEL NUMBER: 321275400068 LEGAL DESCRIPTION: LAKE LIMERICK 5 TR 68 PROJECT DESCRIPTION: DIRECTIONS TO SITE: DETACHED GARAGE LAKE LIMERICK: MASON LK RD TO OLDE LYME. GO TO 'Y' IN ROAD. FOLLOW TO LEFT. General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: Type of Constr.: V-B Type of Use: SF Insp.Area: OT No.of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: ACC Fire Dist.: 5 No.of Stories: 1 Occ. Load: Building:720 Valuation: Building Height: Occ. Status: Unknown Basement: Manufactured Home Information Setback Information Shoreline&Planning Information : y Make: Length: Ft. Front: N 74.0 Ft. Shoreline: Ft. Water Body: No Model: Width: Ft. Rear: S 25.0 Ft. Slope: Ft. Shoreline Desi Side 1: W Ft. 9•: Not Applicable Year: Serial No.: Side 2: E 20.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KKK 12/20/200 $190.61 S22006000 Planning Review Fee KKK 12/20/200 $155.00 S22006000 Building Permit Fee JRN 12/26/200 $293.25 S22007000 Building State Fee JRN 12/26/200 $4.50 S22007000 EH Plan Review TW 12/28/200 $35.00 S22007000 Total $678.36 BLD2006-02133 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2006-02133 CONDITIONS FOR BLD2006-02133 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X1'1 2) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X Z.b 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X '`� b 4) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspection. X 7W 5) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be applied for, reviewed and approved prior to the change. X G 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X --T,.,2d3 7) Per 2003 IRC - SECTION 1609 -WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WI D SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X TF, BLD2006-02133 Please referto the following pages for conditions of this permit. 2 of 4 8) . Per 2003 IRC -SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordancp with the applicable provisions of this section and the manufacturer's installation instructions. ,X ' 1 9) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X , 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X TE$ 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X —TT-IS 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X �T 13) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X -Tg 14) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 15) All property lines shall be clearly identified at the time of foundation inspection. X —T-T-6 16) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X BLD2006-02133 Please referto the following pages for conditions of this permit. 3 of 4 17) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder revented action from being taken. No more than one extension may be granted. X F� 18)• Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X IL6 19) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 20) This parcel is located in a smoke management zone. Please contact a fire warden at (360)427-9670 ext. 459 for further information. X -- ,6 21) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X j4 22) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 1-6 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property Qand structure for review and inspection.OWN ER OR AGENT: P— DATE: 1 -8 -O-7 BLD2006-02133 Please referto the following pages for conditions of this permit. 4 of 4 W o CONCRETE MECHANICAL MANUFACTURED HOME o0 m Footings/Setbacks Gas Piping Date By Ribbons n N interior Date By Interior-Date By Date By CA) Exterior Date 0� ?� p7 By �(� Exterior-Date B Sot-up Point Load!Isolated Footings INSULATION Date By —i BG f SLAB INSULATION Date By Data By FIRE DEPARTMENT Z Foundation Walls Floors Date By Date; rf 9-7 B Data By DECKS FRAMING wails Date By Date By",, Data By PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Date By Date By Type: Data By O.W.V DRYWALLType: Date By Int Brace Wall Date By W Date By FINAL INSPECTION 0 w Water Line Fire Separation c Date By Date By Data 3 By p m 4M Pass or Request Inspect. Type of Insp. Fail Date Date Done By Comments Tr CDFk T 1�' - �,cf> , w s t' ��7 �.3G• i;7 CD ff 8 ScrBckkS -J7 41CL CA —d 0 CD 0 ki FA-MINVIL Owl � _rrr rrr�� 14, ■r rrr - ,���= �r r arm see . 0 Go Date of application: iM rYf g ,tz QG► 00'oop Ice 0' 30 • ut tD G a� 3� *Z ,Tr'► �o�'�t P�',• '•',8 d ° ��rfi• o a 8 o RECEIVED 0 DEC 2 MASON COUNTY . a 4k'IJ •° O ti DE � Q,n? 1 Al � sb, � V F�• '�'a�� 4 J1 ry APti A ,�2 p 00 N +p to IW ? '�► c4 ��' A l oo- N° \p4 r i 4 ` a I*I • \ O i I W t. P - � 4 •� O MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST Owner's Name: 11 Date: i a a Reviewed B Documents:/ CE�D B riding Permit Application Completed RE ✓Planning Intake Checklist Completed, tC 20 TO f ite plan includes:Allowable building area,roofLNI h MA hangs,decks,etc. Q Fire Apparatus Access Road info required? Yes sot4 cous-y —Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pu with LPG furnace O Boiler(heat type O Other:Specify: () 7 P A— Ig OL_ Mechanical/Plumbing Application-WATER HEATER 7L TYP Engineering? Yes (Need 2 sets of calculations)No 1, 1nDI linical report or assessment? Yes No Snow load: pZJ Seismic Zone(circle one) Cr D2 Construction Plans: COMPLETE SETS / Mans Legible �eco nized Scale _✓ L/ g Elevation Views _Cross Section Foundallb an _Roof Framing Plan _Flonr Plan_r ic.. DfFOOM.noted(all floor levels) -a floor levels represented? Loft,crawlspace,etc. Plan Det�ailss v Roof framing details,truss lay-out may be needed,truss or stick framed? WWall Framing-Does bearing-wall height exceed 10'?(Engineering may be required) ✓Window headers marked on plans: Typical header: —F C_Q==te Walls 11 Height `" ei�fe�set xcee ngineenng may a required) —Landings at all exits? Less than 30"above grade? Y / N Heated By Furnace-Location of FurnaceWifidew Sizes ans — Braced wall panels(shear walls)marked on plans or lateral engineering? (Plans may not be approved if not provided.) . , s ory o a o-s ory o,Dz— o COMMENTS: ENGINEERING REQUIRED: Braced wall panels/braced wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 IRREGULAR BUILDINGS(Irregular Shape)R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3)End of BWP extends more than I ft. over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. DESIGN CRITERIA: Wind 85 mph exp B(unless proven otherwise), Seismic Zone: Snow: psf ., ..?—ewxas;e��.ma ?�.-:..r.'Wan,e..w;e.;—r•-.as:n��x!rm.�.r,,.;:w+n..�,.w...:r., .. .ve:.,. MASON COUNTY PERMIT NO. '.��� BUILDING PERWT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 �- CCU On the web www.co.mason.wa.us APPLICANT INFO 11�ATION CONTRACTOR INFORMATION Owner Company Name Mailing dares Mailing Address City St e V IrA Zip C6de Gity State�,:._ Zip Code PhoneOther Ph Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address m E I ail Address Drivers Lic.# DOB Driver Lic.# DOB SEPTIC J-WATER SYSTEM INFORMATION - Connect to Ne Septic Existing Septic Connect to Water System Name of Water System Well Sewer Systerla Name of Sewer System f PARCEL INFORM TI , 12 i t ar el No. Fire District Legal Description _ Site Addres inc tr�et.name,,str' et,,iuffteran y), S Di a tions tq- Wil(timber be cut and sold in parcel preparation?Yes o Is property ithin 200' of Saltwater ��-Lake River/Creek X) 6 Pond 'U U Wetland`F ,'' t Seasonal Runoff Stream�f Slopes or Bluffs /o Is this permit submittal the result of a Stop Work Notice,Correction Notice or other eiiforcem nt action?Yes*gl TYPE OF JOB --New- -dd"-- Alt ---Repaif- Ot of — -- -- PRIMARY RESIDENCE ❑ SEASONAL ❑ Use ofP6Iding " Describe Work No. of Bedroom No. of Bathrooms Square Footage- 1st Floor 2nd Floor ..� _.___.. .__...�. Deck ..... C-overed-p6ck.-- -------��`Other Sq. ft. 3rd Floor Basement Deck Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - M;�?-,r � Model Year Length Width Serial No. Igo. o Bedrooms No. of Bathrooms Type of Heat Ilurchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order�ermit rev_occaa ion. Acknowledgement-of such..is.bys►gNatuce_belew.-�-leek ners eg n'fauve,orThe contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MAPROGRESS INSPECTION.INACTIVITY OF THIS PERMITAPPLICAT,ION OF 180 D YSWIL INVALIDATE THEAPPLICATION. VDate: 12Z/r/—wner/Owners epresentative ntractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted lovam I I Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department nc- Planning Department Environmental Health Department Fire Marshal C _M FEES Building Permit Fee el, _ Site Inspection Plan Review Fee " EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ — TOTAL FEES