HomeMy WebLinkAboutCOM2023-00071 Plumbing - COM Inspections - 11/20/2024 INSPECTION CARD
Mason County
615 W. Alder St.
Building 8, Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
PERMIT# COM2023-00071 PROJECT ADDRESS 791 NE SAND HILL RD Belfair, WA 98528
PARCEL# 123301350010 PROJECT DESCRIPTION DISHWASHER REPLACEMENT
OWNER SCHOOL DISTRICT#403 ADDRESS 71 E CAMPUS DR PHONE 1.360.277.2300
CONTRACTOR WESTERN MECH CONTRACTORS INC ADDRESS 8209 SOUTH 22ND ST PHONE 1.206.605.2202
CONTRACTOR LICENSE WESTEMC798MF LENDER
INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments
Mechanical/Plumbing Final ` t�D I(-2p-
a +
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
COM2023-00071 MECH/PLUMB - COMMERCIAL
PROJECT DESCRIPTION: DISHWASHER REPLACEMENT ISSUED: 07/25/2023
SITE ADDRESS: 791 NE SAND HILL RD BELFAIR
EXPIRES: 01/21/2024
PARCEL: 123301350010
APPLICANT: SCHOOL DISTRICT#403 OWNER: SCHOOL DISTRICT#403
71 E CAMPUS DR 71 E CAMPUS DR
BELFAIR,WA 98528 BELFAIR,WA 98528
1.360.277.2300
GENERAL CONTRACTOR'S LICENSE: WESTERN MECH CONTRACTORS INC License: WESTEMC798MF
8209 SOUTH 22ND ST Expires: 07/02/2024
KENT,WA 98032
1.206.605.2202
FEES: Paid Due
Technology Surcharge $2.46 $0.00
Final Inspection $80.00 $0.00
Plumbing Base Fee $25.00 $0.00
Technology Flat Convenience $5.00 $0.00
Fee
State Fee-Commercial $25.00 $0.00
Plumbing Fees $18.00 $0.00
Totals : $155.46 $0.00
FIXTURES
Guy Plumbing Fixtures
1.0000 For each backflow protective device other than
atmospheric type vacuum breakers 2 inch
(51 mm)diameter and smaller
1.0000 Number of Dishwashers
REQUIRED INSPECTIONS
Printed by:Annie Wilson on:07/25/2023 10:02 AM
Page 1 of 3
Mason County
Mason County - Division of Community Development
615 W. Alder St.
w Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECH/PLUMB - COMMERCIAL COM2023-00071
Mechanical/Plumbing Final Inspection
CONDITIONS
* All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy
code(WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth
in the WSEC and international mechanical code.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
* The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency
(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos
containing materials have been identified and removed from the area to be demolished. Work shall not commence on an
asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B
Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
Printed by:Annie Wilson on:07/25/2023 10:02 AM
Page 2 of 3
Mason County
Mason County - Division of Community Development
615 W. Alder St.
N 9Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECH/PLUMB - COMMERCIAL COM2023-00071
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized Agent: Date:
Printed by:Annie Wilson on:07/25/2023 10:02 AM
Page 3 0(3
MASON COUNTY COMMUNITY SERVICES Permit No: Lom
PERMIT
BUIL ASSISTANCE DING •PLANNING CENTER:
MARSHAL RECEIVED
615 W.Alder St-Shelton,WA 98584
www.co.mason.wa.us JUL 2 4 2023
Phone Shelton:(360)427-9670 ext. 352- Fax:(360)427-7798
Phone Belfair:(360)275-4467- Phone Elma:(360)482-5269
615 W. Alder Street
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:NonwasonSchoolDlstrictlH03 SAND HILL ELEMENTARY SCHOOL NAME:westem Mechanical Contractors
MAILING ADDRESS:7+E.Canpus or. MAILING ADDRESS:a2o9 s.z22nd st.
CITY:Balfair STATE:wA ZIP:98528 CITY:Kant STATE:wA ZIP:9e032
1st PHONE:3602772300 PHONE:2539a59544 CELL: —5222
2'PHONE: EMAIL:permits@westemmech.us
EMAIL: L&I REG#wESTEMC798MF EXP. 07-20J4 /
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number):123301350010 Zoning:
LEGAL DESCRIPTION(Abbreviated):
SITE ADDRESS:791 NE Sand Hill Road CITY 6elf-
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB:
NEW=ADD=ALT=REPAIR=OTHER=USE OF BUILDING School
LOCATION OF FIXTURES/UNITS-1 sT FLOOR=2No FLOOR=BASEMENT=GARAGE[-_—]OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric=LPG=Natural Gas[]Ductless=
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
Dishwasher + Kitchen Exhaust Hood
Hose bibs Dryer Vent
Other 2back4ows Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
x-4(L'1L"-n ACot-/12E�, Lorric-LD -7- Zo-��--3
Signature of Owner U0 rn-tra ton r- Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
i C:".': 1127 Z016 TN
Project North Mason School District • � •
� JHOBART
AIA# 515#
Item# Quantity C.S.I.Section 114000
AM16T—BAS STANDARD FEATURES
+ .67 gallons per rack pumped final rinse
TALL BASE ELECTRIC + 60 racks per hour— hot water sanitizing
High Temperature + User-friendly smart touchscreen controls
+ WiFi connectivity
Door-Style Dishwashing Machine + SmartConnect app and cloud with machine status,temperature M
logs, error code reporting, and cost, consumption and usage �
analysis r7
+ Two stage filtration
+ Pillarless opening
+ 3-sided hood D
+ Single point electrical connection standard,field convertible
to dual point connection
+ 3 phase standard,field convertible to single phase
+ Temperature and chemical lock outs(with Hobart equipped
chemical pumps) i
+ Pumped drain
+ Timed wash cycles for 1,2,4 or 6 minutes
+ NSF pot and pan rating for 2-, 4- & 6- minute cycles
® + Sense-A-Temp'"70'F rise electric booster heater -�
+ Self-draining, high efficiency wash pump with stainless steel
impeller r
+ 27" door opening for 18"x 26" sheet pans or 60-quart r
mixing bowl
+ Stainless steel drawn tank,tank shelf, chamber,trim panels, D
l frame and feet
+ Spring counterbalanced chamber with UHMW guides rn
+ X-shaped revolving, interchangeable upper and lower M
anticlogging wash arms r
+ Revolving, interchangeable upper and lower rinse arms rn
+ Slanted, self-locating, one-piece scrap screen and basket
r� system
C US HSF + Automatic fill ;0
+ Door actuated start
+ AutoGean
+ Vent fan control
SPECIFIER STATEMENT + Service diagnostics
+ Straight-through or corner installation
Specified unit will be a Hobart AM16 Tall Base + Delime cycle with notification (field activated)
electric high temperature dishwashing machine. + Sheet pan rack
Features include 3-sided pillarless hood, touch-
screen controls with WiFi connectivity, NSF OPTIONS & ACCESSORIES (Available at extra cost)
pot and pan rating for 2-, 4- & 6-minute cycles, ❑ Peg, combination and wine rack
27" door opening, pumped drain, auto door start ❑ Chemical pumps
with auto fill, interchangeable stainless steel ❑ Splash shield for corner installations
rinse arms and X-shaped wash arms,delime cycle, ❑ Flanged and seismic feet T Cunningham
❑ Water hammer arrestor kit Approved as Noted
advanced diagnostics and service connection, pp
❑ Rapid fill kit
OL NTI
u to 60 racks per hour, .67 U.S. gallons per rack '�"""_ DE
P P � g P ❑ Sink integration kit COMNLn1TY DE—OPMEFT
pumped final rinse. — Sink saddle &3" leg extension
— Sink rail kit 07/25/2023COM2023-00071 AM16T-BAS TALL
1 year parts and labor warranty. — Fold down table BASE ELECTRIC
❑ Drain water tempering kit COM2023-00071
❑ Door lock kit Mason County
Prison package
J Marine package Permit Document
• Pumped drain air gap kit
Approved by __-- Date Approved by _ Uar
Printed in U.S.A. HOBART • 701 S Ridge Avenue,Troy,OH 45373 • 1-888-4HOBART • www.hobartcorp.com r48565(07/21)Page 1 of 4
kHOBARTI AM16T-BAS TALL BASE ELECTRIC
High Temperature
Door-Style Dishwashing Machine
17"
171/2" 143/4'
I I
253/16" I
I 90 5/8"
P5 MAX
OPEN DOOR
I 121/2" HEIGHT
I I � III
1 78 3/16"
MAX.
HANDLE
HEIGHT 1
67 9/16" \
27" \
641116" DOOR \
MAX. OPENING P4
HANDLE
HEIGHT
i
P3
67 5/8"
291/2"
SERVICE 33 5116"
CLEARANCE TABLE
37" HEIGHT
MIN.
16 3/8" HANDLE 30 3/4"
HEIGHT
I
FLOOR
75/8" CLEARANCSERVICE L CLEARANCE ~9
CLEARANCE
Front View Right Side View
10 3/4"
51/16" E4
� P5
WALL
o E3
El E2
P4X P4
P6653/4" 9
Pi
P7
- - - - - - - WALL
P3 DM2023-00071
P'Mason County
Permit Document
MODEL:
AM16T-BAS
3 3/4" E-950440
Top View
Left Side View
Page 2 of 4 CAD and/or Revit Files Available AM16T-BAS TALL BASE ELECTRIC
� HOBARTJ AM16T-BAS TALL BASE ELECTRIC
High Temperature
Door-Style Dishwashing Machine
WARNING: Electrical and grounding LEGEND
connections must comply with the applicable Electrical Connections
portion of the National Electrical Code and/or E1 Electrical connection:wash pump motor&sump heater,
other local electrical codes. 1" or 3/4" conduit hole; 12-11/16" AFF.
Plumbing connections must comply with Electrical connection: electric booster& controls only or
applicable sanitary,safety,and plumbing codes. E2 single point electrical connection (3PH only) 1" or 3/4"
conduit hole; 14-11/16"AFF.
Electrical connection: detergent& rinse agent feeders, (DPS1
E3 & DPS2) 1.5 amps @ nameplate supply voltage, (RPS1 & RPS2)
1.5 amps @ nameplate supply voltage; 1/2" conduit hole,
15-11/16"AFF.
II Electrical connection:vent fan control(VFC1 &VFC2)
E4 switching circuit only 1.5 amps @ nameplate supply voltage;
1/2" conduit hole, 17-3/16"AFF.
Plumbing Connections
P6 Common water connection including booster heater:
Pi 110°F water minimum, 15-65 PSI recommended; 3/4"female
E4 -- garden hose fitting on 6' long hose supplied with machine;
11-15/16"AFF.
E3 Detergent probe sensor: remove cap and stud assembly to
p� P3 E2 access 7/8" hole; 16-3/8"AFF.
Et P4 Detergent feeder:two locations available. Remove cap and
3413/16" stud assembly to access 7/8" hole; 30-3/4"AFF.
Rinse agent feeder: remove 1/8" NPT pipe plug to access
173/16" 1411/16"� O00 — f P5 1/8" NPT tapped hole; 67-5/8" AFF.
1115/16" Drain connection: 5/8" barb fitting with 6' tong hose supplied
1s71/16" 1211116" 915/16" p6 g g PP
with machine; 34-13/16"AFF. Maximum height 40" AFF.
93116" Optional- cold water connection: 550E water minimum
11'. P7 (drain water tempering-when ordered); 3/4"female garden
53/4" p7 hose fitting on 8' long hose; 9-5/16"AFF.
7 7/16"
Rear view SPECIFICATIONS
30" Capacities
237/16"' Racks Per Hour(maximum).. . . . ... ... . . ...... ............. ....60
1111/16" Dishes per Hour(average 25 per rack) .. . . . ..... . .. ..... .. . .. .1,500
Glasses per Hour(average 45 per rack) . . . . ....... ........ . .. .2,700
Wash Tank(U.S.gallons).... .. .. .. .... . ........ . ............. 10.5
Motor Horsepower
113/8" Rinse Pump . . . . . . . . . . . . ... . . .. .... . .. .. .... . . ....... . . . ..0.18
WashPump.. . . . ... . . . . .... .. ...... . ... . .... . . .. ..... . . .... . .2
i
251/4" Drain Pump.. . . . .... .. . .... .. ...... . ........ .. ....... . .. ..0.21
Rinse
Gallons per Rack.... .. .............. .... .... . . . . .. . . . . . . ..0.67
Gallons per Hour(maximum consumption) ... ...... .. .. .... .. ..40.2
Peak Rate of Drain Flow
1011116" Gallons per Minute(initial rate with full tank) . .... .. . . .. . . . .. ... 18.5
2131$"
Heating
Bottom View Electric Booster(kw)........ .. ........ ... .... .. .. .... . . ..... 7.1
COM2023-00071 Electric Heating Unit(kW)... . .. . .... ..... . . ... . . .. .. .. . . .. ... 5.4
Exhaust Requirements ..... ... .. . ....... ... .... . . .. .. . . . . 450 CFM
Mason County Shipping Weight(approximate). . . . ...... .. ... ... . .. .. ... . . ..357 lbs.
Permit Document Crated Dimensions.. .. .. . .. .. .. . . .. .. . . . . .73.75"H x 36.5"W x 36.5"L
AM16T-BAS TALL BASE ELECTRIC Page 3 of 4
H O BA RT AM16T-BAS TALL BASE ELECTRIC
High Temperature
Door-Style Dishwashing Machine
FieldAM16 with Electric Heat Electric Booster&Controls
El E2
to Dual Point)
Minimum Maximum Minimum Maximum
Am
Voltage Rated Supply Circuit Protective Voltage Rated Supply Circuit Protective
Amps Ampacity Device ps Ampacity Device
208-240/60/1 39.6 50 50 208-240/60/1 42.3 50 50
208-240/60/3 26.9 30 30 208-240/60/3 25.6 30 30
480/60/3 10.5 15 15 480/60/3 12.9 15 15
200-240/50/3* 1 22.1 30 1 30 200-240/50/3* 25.6 1 30 30
380-415/50/3* 1 11.8 20 1 20 380-415/50/3* 14.7 1 20 1 20
*These electrical specifications are not submitted for UL or CUL listing
AM16 Single Point Electrical
Approximatei
Service Connection as Shown . • •••
Rated Minimum Maximum Type BTU/Hr.
Voltage Amps Supply Circuit Protective Latent 12,300
Ampacity Device Sensible 5,700
208-240/60/3 52.5 60 60
480/60/3 23.5 30 30 Plumbing Notes:Water hammer arrestor(meeting ASSE-1010
— standard or equivalent)to be supplied (by others)in common
200-240/50/3* 47.7 60 60 water supply line at service connection.
380-415/50/3* 26.5 30 30 Recommended water hardness to be 3 grains or less for best
*These electrical specifications are not submitted for UL or CUL listing results.
Miscellaneous Notes:All dimensions taken from floor line may Note:Electric heating unit& booster(kW)calculated at 208V.
increase 7/8"or decrease 3/8" depending on leg adjustment. Recommended building flowing water pressure to the dishwasher
Vent hood(if required)to provide a minimum 450 CFM exhaust at or above 20 PSI. Pressures lower than 20 PSI may affect
(ref installation instructions).
machine fill/start-up times.
Net weight of machine including booster:340 tbs. This is a pumped rinse machine. Pressure regulating valve is not
Domestic shipping weight including booster:360 tbs. necessary on hot or cold lines.
Size of racks—19A"x 19%.". For convenience when cleaning,water tap should be installed
near machine with heavy duty hose and squeeze valve.
AM16T-BAS TABLING CONFIGURATIONS AND TRACK DESIGN
NOTE:REPOSITION RACK
30" TRACK BRACKET FOR 30"
Zp" CORNER INSTALLED UNITS 1 7
25" DISPLAY DISPLAY
Pass Thru Installation Tall Corner
Installation
DRILL 0 0.344 HOLE THRU TANK WALL
5�16-18 SST TRUSS HD SCREW
5/16-18 SST LOCKWASHER
5�16-18 SST HEX HD NUT
1.5"ROLL COM2023-00071
TANK Mason County
23" FLANGE DEPTH Permit Document
MAX. TO BE 1"MAX. USE SILICONE SEALER
BETWEEN TABLE AND
LIP OF TANK TO
Suggested Table Design PREVENT LEAKAGE
As continued product improvement is a policy of Hobart,specifications are subject to change without notice.
F48565(07/21)Page 4 of 4 HOBART • 701 S Ridge Avenue,Troy,OH 45373 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.
ES-LF009
For • Applications
Job Name Contractor
Job Location Approval
Engineer Contractor's P.O. No.
Approval Representative
Series LF009 -
Reduced Pressure Zone Assemblies U
Sizes: '/4" —3" (8— 80mm) J
Series LF009 Reduced Pressure Zone Assemblies are designed to JAB
.
protect potable water supplies in accordance with national plumbing r.
codes and water authority requirements.This series can be used in a
variety of installations, including the prevention of health hazard cross
connections in piping systems or for containment at the service line
entrance.The LF009 features Lead Free`construction to comply with LF009
Lead Free'installation requirements.
This series features two in-line,independent check valves,captured
springs and replaceable check seats with an intermediate relief valve.
Its compact modular design facilitates easy maintenance and assem-
bly access. Sizes'/4"-1"(8-25mm)shutoffs have tee handles. Test Cock No.3
Test Cock No.4
Ball Type
Features Test Cocks
•Single access cover and modular check construction for Test Cock
ease of maintenance No. 2 (�
•Top entry-all internals immediately accessible
•Captured springs for safe maintenance Second
PFirst Check Check
•Internal relief valve for reduced installation clearances Module Module
Assembly �'
•Replaceable seats for economical repair �j �/„ Assembly
•Lead Free'cast copper silicon alloy body construction for durability
'/4"-2"(8-50mm)
•Fused epoxy coated cast iron body 27/2"and 3"(65 and 80mm) R.P.Zone
•Ball valve test cocks — screwdriver slotted'/4"-2"(8-50mm) Water Outlet
Relief Valve Assembly
•Large body passages provides low pressure drop
•Compact, space saving design
•No special tools required for servicing Now Available
Specifications WattsBox Insulated Enclosures.
A Reduced Pressure Zone Assembly shall be installed at each potential For more information, send for literature ES-WB.
health hazard location to prevent backflow due to backsiphonage and/
or backpressure.The assembly shall consist of an internal pressure
differential relief valve located in a zone between two positive seating
check modules with captured springs and silicone seat discs.Seats and Inquire with governing authorities for local installation requirements
seat discs shall be replaceable in both check modules and the relief
valve.There shall be no threads or screws in the waterway exposed to
line fluids.Service of all internal components shall be through a single
access cover secured with stainless steel bolts. Body and shutoffs shall
be constructed using Lead Free'cast copper silicon alloy materials. The information contained herein is not intended to replace the full
Lead Free`reduced pressure zone assembly shall comply with state product installation and safety information available or the experience
codes and standards,where applicable,requiring reduced lead content. of a trained product installer.You are required to thoroughly read all
The assembly shall also include two resilient seated isolation valves, installation instructions and product safety information before begin-
four resilient seated test cocks and an air gap drain fitting.The assem- ning the installation of this product.
bly shall meet the requirements of: USC;ASSE Std. 1013;AWWA Std.
C511;CSA B64.4. Shall be a Watts Series LF009. 'The wetted surface of this product contacted by consumable
water contains less than 0.25%of lead by weight.
COM2023-00071
Watts r t s ec�caf in U.S.customary units and mehic are approximate and are provided for reference only.For precise measurements,
Ma sar�rp�eco9 =;Yal ySferrvice.Watts reserves the right to change or modify product design,construction,specifications,or materials with- ` ��
Perm Q'�pU V' 1 1 1 C l ng any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Available Models: '/4" - 2" (8-50mm) Pressure/Temperature
Suffix: Sizes'/4"-2" (8-50mm)Suitable for supply pressure up to
QT -quarter-turn ball valves 175psi(12.1 bar).Water temperature: 33°F-180°F
S -strainer (0.5°-82°C).
LF -without shutoff valves Sizes 21/2" and 3" (65 and 80mm)are suitable for supply
PC -internal polymer coating pressures up to 175psi(12.1 bar)and water temperature at 110°F
(43 C)continuous, 140°F(60°C)intermittent.
W/Press* -press inlet x press outlet('/"-2"only)
Prefix: Standards
U -union connections USC
Available Models: 21/2" -3" (65-80mm) ASSE No. 1013
AWWA C511
Suffix: CSA B64.4
NRS -non-rising stem resilient seated gate valves IAPMO File No. 1563.
OSY -UL/FM outside stem and yoke resilient seated
gate valves
S-FDA -FDA epoxy coated strainer ASSE UL S P® U Pc CN�F
QT-FDA -FDA epoxy coated quarter-turn ball valves
LF -without shutoff valves 0
Approvals
Note:The installation of a drain line is recommended.When ASSE, AWWA, CSA, IAPMO
installing a drain line,an air gap is necessary(see ES-AG).
Approved by the Foundation for Cross-Connection Control and
Materials: 1/4" — 2" (8-50mm) Hydraulic Research at the University of Southern California.
Lead Free`cast copper silicon alloy body construction, silicone Approval models QT, PC, NRS, OSY.
rubber disc material in the first and second check plus the relief UL Classified
valve. Replaceable polymer check seats for first and second 2112" and 3"(65 and 80mm)with OSY gate valves.
checks. Removable Relief valve seats. Stainless steel cover bolts. 3/4" - 2" (20-50mm)without shutoff valves(-LF)
Standardly furnished with NPT body connections. (except LF009M3LF)
Model LF009QT furnished with quarter-turn,full port,resilient
seated, Lead Free`cast copper silicon alloy body ball valve
shutoffs.
Materials: 21/2" and 3" (65-80mm)
•(FDA approved)Epoxy coated cast iron unibody with plastic seats
•Relief valve with stainless steel seat and trim
•Lead Free cast copper silicon alloy body ball valve test cocks
Air Gaps and Elbows --------- A ----------
MODEL BRAIN OUTLET DIMENSIONS WEIGHT
for 909,009 and 993 sizes A B
in. mm in, mm in. mm lbs. kgs.
909AGA Y"-'/z"009, 141 13 21/8 60 31/ 79 0.625 0.28
a/4"009M2/M3 B
909AGC '/4"-1"009/909, 1 25 3'/4 83 4'/8 124 1.5 0.68
1"-1'/2"009M2
909AGF 1'/4"-2"009M1, 2 51 4% 111 6'/4 171 3.25 1.47
1'/4"-3"009/909,
2"009M2 4"-6"993
909AGK 4"-6"909, 3 76 61/8 162 9% 244 6.25 2.83
8"-10"909M1
909AGM 8"-10"909 4 102 7% 187 11'/4 286 15.5 7.03
909ELA '/4"-'/2"009 3/4' 009M2/M3 - - - - - - - -
909ELC '/4"-1"009/909 - - 2% 60 2% 60 0.38 0.17
* 909ELF 1'/4"-2"009M1, - - 31/8 92 35% 92 2 0.91 -
1'/4"-2"009/909,
2"009M2 4"-6"993 B
* 909ELH 2'/2"-3"009/909 - - - - - - - -
Vertical
COM are optional factory-installed fitting on each end of the
approved/certified assembly.
Mason County
Permit Document
vv�� y tCJ c`7 O O c('7 oo Co r—
p�N N N M cIJ CD I� M I, Y V �IJ M CC
y IlLlll M I� I� GO
U.,N cD O M oo
,gyp L(7 O N c2 O O N N
O
CD E o 0 0 0 0 0 0 0
O QJ NO N V m E N N N N N N N N
E Co CD LO t\oo r /R
V � �
r
(d CJ C 0 0 0 0 0 0 0 0
C \\\M M\V ur
N N N N M
E I m O O) I N N N
N N N
E O O O m M
E cD CD r CO m-N -
t` n co of of
LL
co V'V Ifj C....
U O COD c00 COD COD cOD cOD 1OD cc
G V V V V V V V V
E O O O O M M J
E V V 7t`N c K cnT E O O
Q
J 00 o2202ao
O r M
Q � G CD cD c0 N N N
0 cz a
J — LO O W
m -----------V ---------
m m m -G -
E c c O� c
I O
E _ cm C� _
Q -------- \\
m r N N N M.-- � I ''� r r G r r r r r r r r
KJ I E c0 cD co cmcD Q] N I �i co V
co C
` l -
N
m\M \ N I E N N E I O W Lo I O N OHO
1 c M M M M M M C ' } E V N r M r
N j ` ^ r— CD CD CD
Q^ Q G O G I \ O I N
O
I J m W f CYJ O
Q n E cO n E LO u7 0 0 o p
a -
m co of o7 00 00
_ a N
O O O M oo r T M
E f` Co cc-)�
w� E N N N N M T In •A, O
LO
a 3 � U N = E � � m coo oo cCD
oo
000CD�m r- U E ++
r N
_ r E Lo o
E o O
N z c n
' cn
0 0 0 0 0
5ca
W
a
Capacity
Performance as established by an independent testing laboratory. 'Typical maximum system flow rate(7.5 feet/sec., 2.3 meters/sec.)
kPa psi 1/4" (8mm) LF0090T kPa psi 11/4" (32mm) LF009M20T
138 20 -
172 25
117 17
96 14 138 20
76 11 103 15
55 8 69 10
35 5 35 5
0 .25 .60 .75 1 1.17 gpm
�P 0 .95 1.9 2.9 3.8 4.5 Ipm 0 QP 0 10 20 30 40 50 60 70 80 gpm
0 38 76 114 152 190 228 266 304 Ipm
5 7.5 10 15 fps
kPa psi W (10mm)LF0090T 1.5 2.3 3.0 4.6 mps
138 20
117 17 11/2" (40mm) LF009M2QT
96 14 kPa psi
207 30
76 11 172 25
55 8 138 20
35 5 103 15
0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm
�P 0 .95 1.9 2.9 3.8 4.8 5.7 9.4 11.8 Ipm 69 10
35 5
kPa psi 1/2" (15mm)LF0090T o 0
* 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm
172 25 AP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm
5 7.5 10 15 fps
138 20 1.5 2.3 3.0 4.6 mps
103 15 2" (50mm) LF009M2QT
69 10 kPa psi
207 30
35 5 172 25
0 1 2.5 5 7.5 10 12.5 15 gpm
�P 0 3.8 9.5 19 28.5 38 47.5 57 Ipm 138 20 --
5 7.5 15 fps 103 15
1.5 2.3 4.6 mps 69 10 --
35 5 -
kPa psi *a" (20mm)LF009M30T 0 0 0 20 40 60 80 100 120 140 160 180 200 gpm
207 30 �P 0 76 152 228 304 380 456 532 608 684 760 Ipm
5 7.5 10 15 fps
165 24
1.5 2.3 3.0 4.6 mps
124 18
83 12 kPa psi 21/2" (65mm) LF009
41 6 172 25
138 20
0 0 103 15
0 2 6 10 14 18 22 26 30 34 38 42 46 gpm 69 10
AP 07.6 23 38 53 68 84 99 114 129 144 160 175 Ipm 35 5
7.5 15 fps
2.3 4.6 mps 0 0 0 25 50 75 100 125 150 175 200 225 250 gpm
AP 0 05 10- 295 380 475 570 665 760 885 950 Ipm
1" 25mm LF009M2QT 5 .5 10 15 fps
kPa psi ) 1.5 2 2.3 3.0 4.6 mps
207 30
172 25 3" (80mm)LF009
138 20 kPa psi
103 15 172 25
138 20
69 10 103 15
35 5t�771- 69 10
35 5 -
0 0 0 0
0 5 10 20 30 40 50 60 70 80 gpm 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm
AP 0 19 38 76 114 152 190 228 266 304 Ipm A P 0 95 190 285 380 475 570 665 760 855 950 1045 1140 1235 Ipm
7.5 15 fps 5 7.5 10 fps
2.3 4.6 mps 1.5 2.3 3.0 mps
X%IWATM
C - USA: T:(978)689-6066•F:(978)975-8350•Watts.com
Mason County Canada: T:(905)332-4090•F:(905)332-7068•Watts.ca
Permit Document Latin America: T:(52)81-1001-8600•Watts.com
ES-LF009 1813 0 2018 Watts