Loading...
HomeMy WebLinkAboutSoil Investigation Investigation - PLN General - 8/6/1996 GEOTECHNICAL T I4ST I NC LABORATORY Thomas Swidecki 381 Dartmoor Shelton, WA 98584 Re: Subsurface Soils Investigation for a garage Gentlemen: In compliance with your instructions, we have conducted a soils exploration and foundation evaluation for the above mentioned addition. The results of this investigation, together with our recommendations, are to be found in the following report. We have provided three copies for your review and distribution. During our exploration, three density tests and two borings were advanced and soil samples submitted for laboratory testing from the project site. The data has been carefully analyzed to determine soils bearing capacities and footing embedment depths. The results of the exploration and analysis indicate that conventional spread and continuous wall footings appear to be the most suitable type of foundation for the support of the proposed structures. Some variability was encountered in comparing the soil profiles of the site. Net allowable soil pressures, embedment depth, and total expected settlements have been presented for the site, later in the report. If you have any questions concerning the test results, the procedures used,or if we can be of any further assistance please call on us at(360) 754-4612. Respectfully Submitted, GEOTECHNICAL TESTING LABORATORY Harold Parks Engineering Geologist 10011 Blomberg Street SW,Olympia,WA 98512 Phone#:(360)7544612 Fax#:(360)7544848 SOILS INVESTIGATION REPORT 381 DARTMOOR Prepared For: Thomas Swidecki Shelton, WA By: Geotechnical Testing Laboratory 8-6-96 GEOTECHNICAL TESTING LABORATORY DISCRIPTION The purpose of this section is to enumerate details of the proposed structure. The following information was provided by the home owner. The building will be a one story wood garage structure. No basements are planned. Conventional spread footings and slab-on-grade floors are contemplated. Differential settlements are limited to 3/4 inch. Loads of 2,000 pounds per lineal foot for wall footings and 80,000 pounds for columns were assumed for settlement calculations. FOUNDATION DISCUSSION AND RECOMMENDATIONS General Notes: Various foundation types have been considered for the support of the proposed building structure. Two requirements must be fulfilled in the design of foundations. First, the load must be less than the ultimate bearing capacity of the foundation soils to maintain stability; and secondly, the differential settlement must not exceed an amount that will produce adverse behavior of the superstructure. The allowable settlement is usually exceeded before bearing capacity considerations become important; thus, the allowable bearing pressure is normally controlled by settlement considerations. Considering the subsurface conditions and the proposed construction, it is recommended that the structure be founded upon conventional spread and continuous wall footing foundations. Settlements should not exceed tolerable limits if the following design and construction recommendations are observed. Foundation Design Recommendations: On the basis of the data obtained from the site and the test results from the various laboratory tests performed, GEOTECHNICAL TESTING LAB recommends that the following guidelines be used for the net allowable soils bearing capacity. Net Allowable Footing ASTM D 1557 Soils Bearing Depth Subgrade Compaction Capacity surface 90% 1,500 lbs./112 12 inches 90% 2,000 lbs./ft2 The footings should be proportioned to meet the stated bearing capacity and/or the Uniform Building Code 1994 minimum requirements. Total settlement should be limited to 1 inch total with differential settlement of 3/4 inch. Any excessively loose or soft spots or areas that do not meet the compaction requirements that are encountered in the footing subgrade will require over-excavation and backfilling with at least 2 feet of structural fill. In order to minimize the effects of any slight differential movement that may occur due to variations in the characters of the supporting soils and any variations in seasonal moisture contents, it is recommended that all continuous footings be suitably reinforced to make them as rigid as possible. 10011 Blomberg Street SW,Olympia,WA 98512 Phone#: (360)754-4612 Fax#: (360)754-4848 G EOTECHNICAL TESTING LABORATORY Re: In-Place Density Test Report performed on 8-6-96 Project: Garage Inspector: H. Parks Gentlemen: As requested Geotechnical Testing Laboratory performed on-site density testing in accordance with current applicable standards. The results obtained were as follows: Test Location Percent Dry Material Percent # Moisture Density Type Compaction 1 foundation area 7.5 130.2 A 97 2 7.4 128.7 96 3 7.1 127.5 95 4 5 Required Compaction: 90% Material Type: Gravel Fill A: 133.8 @ 12.8% 134.5 Rock Correction 10011 Blomberg Street SW, Olympia, WA 98512 Phone#: (206)754-4612 Fax#: (206)754-4848 GEOTECHNICAL TESTING LABORATORY MOISTURE DENSITY RELATIONSHIP Source: On-site Date Obtained: 8-7-96 Sample ID: A ASTM D 2487 Classification: Gravel Sample Prepared: Moist: X Manual: Dry: Mechanical: X Test Standard: AASHTO T 99: AASHTO T 180: Medwd ASTM D 698: ASTM D 1557: X A Assumed Point Percent Dry Maximum Optimum% Sieve Percent Sample Sp.Gr. Number Moisture Density Dry Density Moisture Size Passing Specs 2.34 1 8.8 126.1 133.8 Ibs/ft^3 12.8% 3.0" 2 10.4 130.8 1.5" 3 12.2 133.8 ASTM D4718,Correction for Oversize Particles 1.25" 4 14.3 132.5 134.5 Ibs/ft^3 1.0" 7/8" 3/4" 93 Moisture Density Curve 5/8" 1/2" 135.0 3/8" 1/4" 133.0 #4 #8 131.0 410 Dry Density #16 129.0 #20 #30 127.0 - #40 #50 125.0 #60 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 #80 Percent Moisture #100 #200 10011 Blomberg Street SW, Olympia, WA 98512 Phone#: (360)754-4612 Fax#: (360)754-4848