HomeMy WebLinkAboutDIS2017-00006 - FIR Inspections - 12/11/2003 05/03/2017 WED 12: 00 FAX 3602756224 ... MS50r1 Bldg Dept Z001/001
IT Q 0(p
�vvfs•tiz /i1���
i
11.0. Hum 277 - NR 460 Old Relralr llwy H.elfrir, WA 9952N
• • • . • • • AGENCY CASE NUMBER
North Mason Regional Fire 17-0741
Fire Marshal's Office 17-FM0017
DATE OF FIRE
.5 ;/ 2017
PARCE -
1233250000
L064TION OF FIRE
2254 ate Route 3 kelfair )K5?8
70WNERCtil OCCUPANT
hil Oliver ,(It's Hide-away
AMOUNT OF LOSS: $ 5,000 REPAIRABLE: Yes
STRUCTURALLY UNSAFE CONSTITUTES DANGER TO HUMAN LIFE Yes
*REFER TO HEALTH DEPARTMENT: NO
*REFER TO ASSESSOR If a (cable : N/A
*REFER TO BUILDING DIVISION: Yes
-REFER TO CODE ENFORCEMENT: N/A
ALERTS: HAZARDOUS MATERIALS OR SUSPECTED DRUG METH LAB NO
REFER TO HEALTH DEPARTMENT N/A
REFER TO MCSO No
NOTE: Fire Report cm lilt at rlh ML on Regional lire
Submitted b
.Fire Marshal .1. 1 ticks' rt 14 OP V1
Phone; 360 275 — 6711 x2
;'All referrals are to be done by the DFM ASAP.
Il- _
1 ;
rG-
1.
Mason County Fire District 2 Fire Prevention Officer:
>t 460 NE Old Belfair Highway / PO Box 277
(360)275-6711 Ext. 2
Belfair,WA 98528 • 360-275-6711 • www.mcfd2.com
Date Time _ Phone _ Last Service Date
y 7t 27- ( - 4- S /D Extinguishers
Busirhess Name Fax Alarms A
Sprinklers
Owner/Manager Name Occ ancy Hood
IwAN04 G Knox Box J
Address Correction Date
17• Re-inspected
Your attention is called to the following violations of the International Fire Code
and/or other applicable Local,State and National Codes.
Fire Prevention Inspection Report
❑ No Deficiencies Found
Please correct the following violation(s)on or before the date listed.
` r[E] 901 Have your fire alarm system,fire sprinkler systems and A re-inspection will be made at the end of a specified time.
portable extinguishers serviced by a certified technician.This must When you change door locks,call 360-275-6711.
be accomplished on at least an annual basis.
� ❑ 703.1 Maintain fire rated construction.
❑ 609.1 Have your range hood suppression system serviced every
six months by a certified technician to comply with IMC. ❑ 703.2.2 Remove door hold open devices/doors equipped with
❑ 30433 Dumpsters shall not be within 5 feet of combustible wall or eve. automatic door closers shall be maintained in the closed position.
❑ 315.2 Storage of combustible materials in buildings shall be ❑ 901.6.1/2 Provide service and test records for fire protection
orderly.rderly.
❑ 903.3.7 Fire Department connections shall be provided with
❑ 315.2.1 Ceiling clearance.Storage shall be maintained 2 feet or threaded caps or covers/FDCs shall be immediately accessible.
more below the ceiling in non sprinklered areas of buildings or a
minimum of 18 inches below sprinkler head deflectors in sprinklered ❑ 1003.E Obstructions shall not be placed in the required width of a
areas of buildings. means of egress.Exits shall not be obstructed in any manner.
❑ 315.2.2/3 Combustible materials shall not be stored in exits or ❑ 1006.1 The means of egress,including the exit discharge,shall be
exit enclosures.Combustible materials shall not be stored in boiler illuminated at all times.
rooms,mechanical rooms or electrical equipment rooms. ❑ 1008.1.8 and 1008.1.8.3 Exit doors shall be openable from the
❑ 404.4 Provide approved evacuation plan. inside without a key or special knowledge or effort.Double keyed
deadbolts are not allowed.Post a sign"This door to remain unlocked
❑ 505.1.1 Address numbers for commercial buildings shall be: during business hours."
0"-50"from street or less: 6-12"minimum height;
50'to 100'from street: 12-18"minimum height; ❑ 1011.1 Exit signs shall be internally or externally illuminated.Faits
more than 100'from street: 18-24"minimum height. and exit doors shall be marked by an approved exit sign readily
El506.1 Provide a Knox Box to be installed in an approved location. visible from any direction of egress travel.
Provide keys necessary for access. ❑ 3003.2 Stationary and portable compressed gas containers,
cylinders,tanks and systems shall be marked and secured against
❑ 605.3 A working space of not less than 30 inches in width,36 unauthorized entry and safeguarded in an approved manner.
inches in depth and 78 inches in height shall be provided in front of 3003.2.1,3003.2.2,3003.2.3 and 3003.3.1.
electrical service equipment.
El605.1 Identified electrical hazards shall be abated.Identify all 22 Provide at least 50 pounds of rice hulls other approved
absorbent and at least 25 approved absorbent pads,
s,minimum
breakers.Provide cover plates for all electrical boxes and remove all dimension 16 inch by 16 inch and/or other spill control equipment.
multi-plug adapters.
❑ 3403.3.2 Provide a flammable liquids storage cabinet.
❑ 605.3.1 Doors into electrical control panel rooms or fire protection
systems shall be marked with a plainly visible and legible sign. ❑ 3403.5.3 Warning labels.Individual containers,packages and
cartons shall be identified,marked,labelled and placarded in
❑ 605.5 Extension cords and flexible cords shall not be a substitute accordance with federal regulations and applicable state laws.
for permanent wiring.Extension cords shall be used only with Provide MSDS sheets.
portable appliances.
❑ 3404.2.13.1.2/3 Underground storage tanks need to be capped
❑ 605.6 Open junction boxes and open wiring splices shall be within 90 days and removed within 1 year.
prohibited.Approved covers shall be provided.
a, V J,..,
Owner/Manager: Inspect r:
Q ✓t vtA``G' [p✓ �t l4'
Lam`
7
CA
N
1 - � oo ► -7