HomeMy WebLinkAboutBLD2024-01210 Modular SFR - BLD Application - 10/10/2024 Permit No —o 11
Aft MASON COUNTY RECEIVED
COMMUNITY DEVELOPMENT f Z21
Permit Assistance Center,Building,Planning OCT
BUILDING PERMIT APPLICATION 615 W. Alder Steet
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:Brandi Bogosian&Liana Mezo Trust NAME:Wolf Industiies/Jahnee Dragoo
MAILING ADDRESS:3048 Belvidere Ave SW MAILING ADDRESS:607 SE Eaton Blvd mom
CITY:Seattle STATE:WA ZIP:98126 CITY:Battle Ground STATE:wA ZI.P:98604 Z
PHONE#1:206-937-5766 PHONE:360-912-M7 CELL:
PHONE#2:206-607-7432 EMAIL,:jdragoo@wotfind.com
EMAIL:Brandi.Bogosiani§hotmail.com L&I REG#WOLFIIi921 BD EXP.�/2 /2025
PRIMARY CONTACT: OWNER❑ CONTRACTOR OTHER❑
NAME. EMAIL
MAILING ADDRESS CITY STATE ZIP
PHONE CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 321225000037 'ZONING RR5-Rural Residential 5ac
LEGAL DESCRIPTION(Abbreviated) LAKE LIMERICK#3,LOT 37 FIRE DISTRICT Distinct 5
SITE ADDRESS Not yet assigned CITY Shelton
DIRECTIONS TO SITE ADDRESS E Shetland Road to E ST Andrews Dr to E Way To Tipperary Street
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO CI SNOW LOAD:—Z&sf
IS PROPERTY{i'ITHIN 2�00/FT OF THE FOLLOW ING: (l'lrcck rdl tl at aPPb)
SALTWATER❑ LAKE Ly RIVERICREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW g' ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residers,Gamge,Cm-urwrcial Blatt,Etc.)Primary Residence
IS USE: PRIMARY 10 SEASONAL❑ NUMBER OF BEDROOMS 2 NUMBER OF BATHROOMS 2
HEATED STRUCTURE? YES(IYholeBldg)V YES#artlsJofB14❑ NO❑
DESCRIBE WORK 28'x44'Wolf Industries Modular home placed as primary residence on subject property.8'xi a,80 SF covered porch on back entry.
SQUARE FOOTAGE:(pmpa+ed)
I ST FLOOR 1,232 SFsq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK 80 SF sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIALNUMBER
ENVIRONMENTAL HEALTH:
SEWAGEISEWER SOURCE: SEPTIC Ef SEWER❑ 1 NEW EXISTING❑
PLUMBING IN STRUCTURE? YES 0a NO❑ jfyes,attach completed Water Adequacy Form
PERIMETERIFOUNDATION DRAINS PROPOSED? YES❑ NOD EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS 2 TOTAL BEDROOMS 2
OWNER acknowledges that submisslon of inaccurate Information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and 1 further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or pates of Interest regarding this project.The owner or legal
representative,represents that the information provided is accurate and grams employees of Mason County access to the above described property
and structure(s)for review and inspection.This permiVapptication becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
Brat dr So�ouas7 M� 10/09/24 10/09/24
x _ ,or...�,r nx Qo m rip-•
Signature of OWNER('Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTESICONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
Permit No: � �p�to
MASON COUNTY
COMMUNITY DEVELOPMENT RECEIVED
Permit Assistance Center, Building,Planning OCT 10 2024
PLUMBING & MECHANICAL PERMIT APPLICATION 615 W. Alder Skeet
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:Brandi Bogosian&Liana Mezo Trust NAME:wolf Industries/Jahnee Dragoo
MAILING ADDRESS:3048 BELVIDERE AVE SW MAILING ADDRESS:607 SE Eaton Blvd
CITY:Seattle STATE: wA ZIP:98126 CITY:Battle Ground STATE:WA ZIP:98604
1"PHONE: PHONE:360-912-9507 CELL:
2°d PHONE: EMAIL :jdragoo@wolfind.com
EMAIL: L&I REG#WOLFn1921BD EXP.
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number):321225000037 Zoning:RR5-Rural Residential 5ac
LEGAL DESCRIPTION(Abbreviated):LAKE LIMERICK#3,LOT 37
SITE ADDRESS: Not yet assigned CITY:Shelton
DIRECTIONS TO SITE ADDRESS:
E Shetland Road to E ST Andrews Dr to E Way To Tipperary Street
TYPE Of JOB:
NEW=ADD=ALT=REPAI OTHER=USE OF BUILDING
LOCATION OF FIXTURES/UNITS—I ST FLOOR=2ND FLOOR=BASEMENT=GARAGE=OTHERO
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UN TS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric[ LPG=Natural Gas=Ductless=
Toilets 2 Type of Unit No.of Units Fees
Bathroom Sink 2 Furnace
Bath Tubs 0 Heat Pump
Showers 2 Spot Vent Fan
Water Heater 1 Propane Tank
Clothes Washer 1 Gas Outlets
Kitchen Sinks 1 Wood/Gas/Pellet Stove
Dishwasher 1 Kitchen Exhaust Hood
Hose bibs 1 Dryer Vent
Other 0 Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
Emil 8oaatian Lcarr�Meta- 10/09/24 10/09/24
X Brandi Bogo�024 19:45 PDT) Liana Mezo(Oct 9,2024 20:01 PDT)
Signature of Owner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Rev:1/27/2016 JBN
f
Name Wolf Industries/Jahnee Dragoo Parcel# 321225000037 BLD# 10
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code, Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
Buildings 23 X 44 = 1232 SF
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas) 1232 SF
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor. I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for
orrr review and inspection as may be required.
X „ Owner/Agent/Contractor(circle one)Date:9/20/2024
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name___ Parcel# BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
hgp//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed-
in it entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
Mail:P 0 Box 1850, Shelton WA 98584
Physical: 415 N 6th St,Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone: (360)-427-9670 EXT.352
Mail:P 0 Box 1666, Shelton WA 98584
Physical:426 W Cedar St,Shelton WA 98584
A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X ... Owner/Agent/Contractor(circle one)Date: 10/9/2024
Page 2 of 2
..yV,..l.. r-
�� w� �� � ` PROPOSEDDRAINFlELD - BOGOSUWLOT i
n--- NEIGHBORING LOT
_8114 - - Properly Owner:
_ �_-}-^' W,,,,�.µ Liana S Brandi Bogosian
_ I
'•"� � I Sfte Address:
INOTYETASSIGNED
Parcel:
321225000037
i
MIN 10'SETBACK FROM DRAINFIELD i Wolf Industries
' 607 SE Eaton Blvd.
( IBattle Ground,WA 98604
)dragoo@wolfind.com
EH APPROVED ) �.l - PROPOSED1797SFGRAVEL (360)912-9507
I ) Cam' !' DRIVEWAY WITH TWO PARKING )Impervious Area
Rhonda Thompson 11/12/2024 r EL2 yr 0• SPOTS
7lF iv_ I House:1232 SF
m N PROPOSED WATERLINE Deck:80 SF
l A o 1!-0' + PROPOSED POWERLINE
I Driveway:1797 SF
Total:3109 SF
EH Setbacks ' , m I New:3109 SF
A.) Drainfield/Reserve requires 10'setback from footing/foundations ) _ 115'SETBACK I Total Lot Area:14219 SF
B.)Septic tank(s)requires 5'setback from all footing/foundations to Building Coverage:1232 SF
C.)No foundation/Perimeter Drains within 30ft,downgradient of i I Lot Coverage:8%
Drainfield/Reserve area g 11 1/32• ) _
D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within )
50ft,down gradient of Drainfield/Reserve area
I )
IGarage � i i
HousNOT AN APPROVED SEPTIC DESIGN ) ' I .
Must use SWG 2024-00281 for septic installation � Hmse + )
I b I
I o ----- COMMON LINE i
SETBACK
WATER LINE I o ) o I
--- SEWER LINE (_ _ N - - DEL 220 -_- PROPOSED SEPTIC TANK
POWER LINE APPROX-OHWM
PROPOSED WOLF INDUSTRIES MODULAR HOME,44'X
NLevel 1 - 0,-0' - \, -- -- �u• 51 =�� J_ - 28,,1232
`l _ SF WITH 9.5"OVERHANGS, 1348 SF ROOF COVERAGE
APPROX.SHORELINE - a-- ---- DOWNSPOUTS TO SPLASHBLOCKS AT REAR CORNERS.
DECK
ENTRY
Site Plan ?
WOLF INDUSTRIES Bogosian °" °" Datei30A)Z}-o�alo
— — _ _
- — - Proled number 22664
- - ----- - --- Date 9/20/2024 A 101
id R i rmary Residence - Drawn by JahneeDra oo -
www.wolfind.com P g
Checked by Noelle Christ Scale As indicated 5
"'':""`+ 21l wAYT TIPr23tAin ,�
PROPOSED DRAINFIELD BOGOSIAN LOT —�
12Lj�E00]!a. ,12ta50R114 aasaaoeia nl E WAY TO
--- -3z, ..�,a NEIGHBORING LOT —
0' _6 114" - Property Owner:
Liana&Brandi Bogosian
3212
Site Address:
NOT YET ASSIGNED
o
- I -'
t I Parcel:
-� ( �321225000037
11MYaooEV I
a2,22Wa760r 3 21225 00 003 6 a MIN 10'SETBACK FROM DRAINFIELD Applicant:
cwaYmnvreru�ni Wolf Industries
607 SE Eaton Blvd.
wAVTo mrcru�m � I Battle Ground, WA 98604
- c2 jdragoo@wolfind.com
I I� (360)912-9507
aooaor ara
.- -_ PROPOSED 1797 SF GRAVEL
00 M SPOTS
WITH TWO PARKING Impervious Area
N EL 240— 12'-0"
I House: 1232 SF
cv rn Deck: 80 SF
CD I PROPOSED WATERLINE I Driveway: 1797 SF
N : 18'-0" PROPOSED POWERLINE
Total: 3109 SF
I a; New: 3109 SF
o 115' SETBACK Total Lot Area: 14219 SF
0) Building Coverage: 1232 SF
I I I Lot Coverage: 8°/O
9'- 11 1/32" 1 5'-0"
M
Garage M I
House
o>
N
I �
J House I I
I I
Deck I I o I
I M O b
M
COMMON LINE
c' SETBACK
(V to
— - WATER LINE o i °O o
c — iv — `^°EL 220 —I PROPOSED SEPTIC TANK
SEWER LINE I co
- POWER LINE APPROX. OHWM
Level 1 _ �L� (6_p^ `— 28ROPO 2ED WOLF INDUSTRIES MODULAR HOME, 44'X
N111 30'_01124'-5 1/3 �f _ SF WITH 9.5" OVERHANGS, 1348 SF ROOF COVERAGE
APPROX. SHORELINE _ _ �� DOWNSPOUTS TO SPLASHBLOCKS AT REAR CORNERS.
No. Description Date Q
WOLF INDUSTRIES Bogosian site Plan �LDaDaq-olalo
Project number 22664 a;
Date_ 9/20/2024 Al 01
Primary Residence Drawn by Jahnee Dragoo N
www.wolfind.com ----- Cl
Checked by Noelle Christ Scale As indicated
r