Loading...
HomeMy WebLinkAboutFIR2011-00040 Final Modification to Sprinkler System - FIR Permit / Conditions - 7/29/2011 i MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670, ext. 352 Shelton, WA 98584 l� FIRE PROTECTION PERMIT FIR2O11-00040 APPLICANT: LES KRUEGER RECEIVED: 7/22/2011 CONTRACTOR: LICENSE: EXP: ISSUED: 7/22/2011 SITE ADDRESS: 30 NE ROMANCE HILL RD BELFAIR EXPIRES: 1/22/2012 PARCEL NUMBER: imonn2 LEGAL DESCRIPTION: SAM B. THELER'S HOME &GAR TRS PCL 1 OF BLA#01-13 PTN TR 5 N 140' PROJECT DESCRIPTION: Modification of sprinkler system-add head(s) to existing system GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood&Duct?: N Dry Chemical?: Y Pressure Switches:: Smoke Detectors: Duct Detectors: Wet Chemical?: N Zones: Heat Detectors: Sprinkler?: Y Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:() - Second Floor: Sprinkler System Permit Ff $168.50 $168.50 Auto Fire Alarm?: Third Floor;: p y Total: $168.50 $168.50 FIR2011-00040 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FI R2011-00040 _ CONDITIONS FOR FI R2011-00040 1.) Own , Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X. 2.) Valid mit Must be on-site. X 3.) P he fire sprinkler company, Fox Fire, the existing system is a dry pipe system. The additional head is to be added on the new exterior canopy. An unheated area, the existing system must be a dry pipe system to meet the requirements of NFPA 13. Additional work may be required based on the interior remodel being done on the building. If any of the existing heads are blocked or obstructed. The heads will be required to be moved and a addi 'onal permit will be required. x This permK1 becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access tv the a ove des ibed property and structure for review and inspection. OWNER OR AGENT: DATE: 7/..)>Z FIR2011-00040 Please refer to the following pages for conditions of this permit. Page 2 of 4 -n CONCRETE MECHANICAL MANUFACTURED HOME X N C Footings /Setbacks as Piping ByGas Ribbons M � � Interior Date By Interior•Date By Date By M OC Exterior Date By Exterior-Date By Set- up p Point Load J Isolated Footings INSULATION r Date B BG i SLAB INSULATION y- - m mm-- Cl) Date By Data By FIRE DEPARTMENT Foundation Wails Floors Date By Date By Date By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Date By Date a OTHER Groundwork Attic Date B pate By Type y Date C3y 0.W.v DRYWALL Type. Date B Int.Brace Wall Dam y B y y Date By FINAL INSPECTION N Water Line Fire Seperation Date By Date By Date By O o Pass or Request Inspect. CD Type of Insp. Fail Date Date Done By Comments c 0 Ski cc U) y M O n O 7 a o' 3 U) O r. N N N (C] (D W O A t MASON COUNTY FIRE MARSHAL Mason County Bldg.III 426 W Cedar St PO BOX 186 Shelton,WA 98584 (360)427-9670 Ext.273 Permit# Mason County Fire Protection System Permit Application Incomplete application will not be accepted Owner: il E.C�E2 '� <<2uF,C1 L__P Phone#: Mailing Address: ';D lAE V- l' City:'r),gLJE&G� State0k Zip: % ?L_ -!1F\o\Site Address:3o tCY2z LAAh1cF_ kL.t_90 City:'SEL_FA;/L State: QA-Zip:5�3� Parcel #: VZ S ;Z-So -000 0L Legal Description: Lien/Title Holder: Address: City: State: Zip: Contractor:1:5,p?1r, Phone #:3(Qp al I L'IS S Address:'Pm '6a K (59-1 City:P-OV4AkAp_p State:&Zip.Cjj�. (o{o Contractor Registration #: 1�0x r_� RS-- IZ--M Expiration Date: iz� Building Square Footage (existing& proposed): 1St / 2nd / 3rd Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry Y- New System: Standpipe: Wet Dry Modification: AFA: Hood& Duct: Dry Chem: Wet Chem: Fire Pump: UL certified Monitoring company: Phone #: Contractors Bid Price: $ Plan Submittal Requirements Your plan submittal shall include the following_ • Plans shall be on standard 24"x 36"paper,drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls,partitions, stairway enclosures,concealed spaces,etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones,circuits,devices,and end—of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50. A plan review fee will be calculated at 65%of the permit fee(minimum$109.50)and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: Date: O v! � 1 DYNA—THREAD (ASTM A-135) GENERAL LEGEND NOMINAL OUTSIDE DIA. INSIDE DIA. WALL THICKNESS LBS/FT H2O GAL/FT PIPE SIZE IN. mm IN. mm IN. mm PLUS PIPE 4 EARTHQUAKE BRACING AND #OF BRACES DIR. (DEFAULT OF 1) PIPE 1 1.315 33.4 1.080 27.4 .118 3.0 1.73 .048 � GROOVEDN CAP AFF ABOVEHEIGHT FINISHED FLOOR 1V4 1.660 42.2 1.408 35.8 .126 3.2 2.54 .082 CH CEILING HEIGHT 1Vi 1.900 48.3 1.639 41.6 .131 3.3 3.22 .111 p R C. REDUCING COUPLING 2 2.375 60.3 2.104 53.4 .136 3.5 4.57 .195 0p� y RI�GIPD CWPLIN?I UNLESS NOTED ) OUTLET COUPLING 1 PLUG ' WELDED OUTLET pP� FI'r FITTING CENTERUNE E/C ND TO CENTER QX HYDRAUUC REFERENCE POINT C/C CENTER TO CENTER Q BOO I PIPE TO BOTTOM OF DECK C/E CENTER TO END VEGROOVE NEW CANOPY BOJ PIPE TO BOTTOM OF JOIST TG THREAD%GROOVE �lv FOS FACE OF STUD TxF THREADCFIT' fOW FACE OF WALL ATR ALL-THREAD ROD I NEW SPRINKLER PIPE ----EXISTING SPRINKLER PIPE I aaC DRUM DRIP IDENTIFICATION SIGNS AT EACH VALVE TO INDICATE ITS FUNCTION AND WHAT IT CONTROLS PER NFPA 13(ED.1BBB)PARA 3-93!5-14.1.1.12 I ILLJ ®�ELECTRIC BELL(Br OTHERS) — SYSTEM VOLUME U �1on 155 GAL.CAP 4'nix COUP AIR COMPRESSOR c0 /MOUMOUNTED TO ra cI. 1' � MOUNTED RISER GENERAL NOTES `� 9'ARE 9"MiKLER HEAD CARNET ATTACHED To WALL NEAR RISER SPRINKLER SYSTEM DESIGN PER N.F.P.A. 13 2010 ED. 4'RASCO DRY PIPE VALVE + W/6 SPARE HEADS AND WENCH SPRINKLER PIPING PLAN ALL MATERIALS SHALL BE U.L. LISTED OR F.M. APPROVED FOR FIRE PROTECTION W/PRESSURE 6WTCH L�/J, FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. 13 s Hi/LOW AIR ALARM\ SYSTEM ACCEPTANCE AND APPROVAL REQUIREMENTS SHALL COMPLY WITH N.F.P.A. #13 SCALE: 1/4' = 1'-0' FTI IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT 2'aTAN� �4 FLANGE ADAPTER THROUGHOUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND /�4'CHECK VALVE 0 2' 4' 8' OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO 6x4CON Rm ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF ALL ELECTRICAL, PAINTING OF PIPE/ PIPE IDENTIFICATION, FURRING, CUTTING OR PATCHING TO BE BY OTHERS SPRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE x FOR CLARITY NOT ALL HANGERS ARE SHOWN, BUT WALL BE INSTALLED PER NFPA13 + BUILDING IS LIGHT HAZARD OCCUPANCY CLASS IN ALL AREAS AND OR ROOMS UNLESS OTHERWISE NOTED 5'W6xINS'35ODA'GxGG THREADED PIPE 1' - 2' PIPING TO BE 'DYNA-THREAD' BACKFLOW PREVENTm CHANLOCN VALVES m 2T4'z2N'x4'FDC 4'FLEX COUP 6'NC FLANGE/ 6'x-0'STAINLESS REDUCER I V ANNULAR ACE i FLOW TEST 6'U.C. 94 PSI STATIC (UG BY O—) 87 PSI RESDUAL EXISTING RISER DETAIL I FLOWING 608 GPM BY MASON COUNTY FM 06-03-03 SCALE: 3/8' = 1'—O' Q��4, I �MeuvcEI�'a R° SPRINKLERS SYM DESCRIPTION SIN TEMP QTY UG DI_Y_x—x_x — a. _�_ RASCO MODEL 'F30R' QR CHROME DRY HORIZ. SIDEWALL 1'NPT 5.6K R5734 200 1 i O EXISTING UPRIGHT -- 155 -- AU CF WK /WI6MW O I 6'UG DI v� N 'm ex on,Inc, p SWG-20 (144 x-2') q�`'�e Cert(rj� Ar GST-20 �V4�X-2' 3' MAX PIPE SIDE i 3 5 E erd2Vi. MAIPE IZE -SW�-25-380 (�3fi GSI-30 Y4 x-3' 4 MAX PIPE ZE 4 MAX PIPE SI E -N. ATR _3b' ATR I B.Cok TENANT IMPROVEMENT I 2, TAX PARCEL ►: 12332-50-00012 N s'UG DI n - ry~ FIRE PROTECTION PLAN RK 'HANR ADJUSTABLE RING -HANGER ADJUSTABLE RING I t`oO Abu ���~ FOR 6 EXISTING SITE PLAN SAMMY SCREW ROD AND RING HORIZONTAL SAMMY SCREW I SCALE: 1' = 30' ne4xm�t� 1' CLFTON RIDGE FIRE PREVENTION, INC. COAL COMPLEXP.O. BOX 594 1/2• 30 ROMANCE HILL qp PORT ORCHARD 19 5 98366 2' 1' BELFAFI INA (FOXFIP1127MB IF SHEET IS NOT 34' x 22' 1/2' SCALE ACCORDINGLY DRAWN BY ABC JOB NO. DATE 20JUL11 1 DWG NO. 1 OF 1 Bulletin 157 Rev.H ® Model F3QR CD R liable CD Quick Response Dry Sprinklers Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- T kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent Pendent Pendent/HB • Concealed • Horizontal Sidewall (See Fig. 1) (See Fig. 2) • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2"(38mm)escutcheon adjustment on pendent sprinkler. 4. 112" (13mm) escutcheon adjustment on recessed sprin- kler with push-on/thread-off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on/thread-off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. Recessed FP Pendent Concealed 7. Attractive appearance. Employs 3mm frangible glass (See Fig.3) (See Fig.4) bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" -to - 48" (51mm-to- 1219mm), in '/4" (6mm) increments. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. y US Patent Numbers 5,775,431 and 5,967,240. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Cer- Recessed F1 Pendent Horizontal Sidewall tified for Canada (cULus) (See Fig.5) (See Fig.6) Style Response S s emkl r e Hazard de ll Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction R5714 Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light Horizontal Sidewall/HB R5734 All Preaction (See Fig. 7) 2. Certified by FM Approvals Sprinkler lux" Style Response System Type Hazard Pendent Wet Pipe Light ffAllp I Recessed F1 Pendent QuickOrdinar Ordinary, Dry Pipe Groups I R5714 All Preaction P 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light Recessed FP Recessed F1 R5734 All Preaction Horizontal Sidewall Horizontal Sidewall 3. NYC MEA 258-93-E (See Fig.8) (See Fig.9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F30R Dry Pendent Sprinkler "A"Dim. 1 2"to 48"(51 mm to 1219mm)in 1/4" 6mm increments Finishes"' Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Bronze Brass(3) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Ratina Temp. White Polyester(2) White Ordinary 135-F (57°C) 100-F (38°C) Orange (')Other finishes and colors are available on special order. Ordinary 155-F (68-C) 100-F (38-C) Red I1j Consult factory for details. Intermediate 175 F (79 C) 150 F (66 C) Yellow (2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate 200 F (93 C) 150 F (66 C) Green White High(') 286 F 141 C 225 F 107 C Blue (3)Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. Inlet Pr.traei..Elevated t'>Listed and Certified only by cULus. Above maid.Pipe Inlet Pmtm w slnn Elstsd r-- -y�y Ab—land.Pipe F --- Y system Tea Syetsm Tee 1/9" 1'NPT 72 De. [s4.omm] 2 1/2•Id3.Smm] 1•NPT •A•Dimension Hole in Ceiling "A•al i Ran qa,H.M In Gelling I Adjustment Range Adjuefmmt Range 1 4• 6.4mm 3 1/2• Dia. m] / t- ] 1 [42.5.Die' +1/Y[+1xJmm] Fxu D'a. +1 1/4•[+31.emm] [L2.Smm] 1 1/2"[3e.1mm] i Total Adjustment I 1/2-[12J J. mn] SpK �"""nklsr Co.Can Ceiling 1 1/4•[31.8nm] -Ce Cm �c«Ilno 1•125.43/4 t4mm] tal Adj. Ewuteheon Escucheon Eccheon 1/2'I ]iin Adjustment Eaouto AaJ. u I Position Spnrikhr Can f Escutcheon Nominal Position ' S/e. 1-1/4'(31.5. 1 1 3/e• of Escutcheon [41.3mm] Nominal ProW.ua [41.3 mm] 1/4*(6.4mm]F— —A Protrusion 3"po. 2 13/64•[SS.eemm] r3ncree [75.2mm] Is fm1-a �. Fig. 1 Fig. 2 Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nomi- position. Escutcheon adjustment provides'/4"(-6mm)to +11/4" nal position. Escutcheon adjustment provides'/2"(-12.7mm)to (+32mm)"A"dimension adjustment range. +1/2"(+12.7mm)"A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN):R5714 Model F3QR Dry Recessed FP Pendent Sprinkler ------ "A"Dim. 31/z"to 48" 89mm to 1219mm in 1/4" 6mm incrementsi Inlet Protrusion Elevated c ------ ----T-- Above Inside Pipe t Fi i h —Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated system roe White Polyester(2) White 2 1/2" Dia. 1" NPT t']Other finishes and colors are available on special order. [63.50mm] Consult factory for details.Cup remainds unfinished. "A" Dimension Hole in ceiling Only the escutcheon will contain desired finish. Adj°'t±1/4 Range 2 19/64'Dia. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or [t6.35mm] [56.34mm] White. Nominal h Position Sprinkler Standard Temperature Ratings of Escutcheon Cup Assembly Sprinkler Max. Classification Temperature Ambient Bulb Color Tcei ing I Escutcheon Rating Temp. — ce;I;; Ordinary 135-F (57-C) 100°F (38aC) Orange 1/4" [6.35mm] Ordinary 155°F (68-C) 100°F (38°C) Red Escutcheon Adjustment Intermediate I'] 175°F (79°C) 150°F (660C) Yellow 1/4"[6.35mm] 3 7/32"Dia. Intermediate 200-F (93oC) 150°F (66°C) Green Escutcheon 2"(12.7 L [6,.76mm] High(') I 286°F 141°C 225°F 107*C Blue I Total Adjustment t37FW2-C Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig.3 for interior applications. Note: Do not install the Model F3OR Dry Recessed FP Pendent Sprin- t']Listed and Certified only by cULus. kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 2. Model F30R Dry Pendent Concealed Sprinkler "A"Dim. 31b"to 48" 89mm to 1219mm in 1/4" 6mm increments Inlet Protrusion Elevated Above Iodide Pipe CCP Cover Plate")Finishes`2' Standard Finishes Special Application Finishes '' r_, _ _ r_t Chrome Plated Bright Brass Plated System Tee White Black Plated Black Paint 1"NPT Off White z 1/2'Dia. Satin Chrome [63.50mm] i "A"Dimension (1)Utilizes the 1/2"cover plate with 3/8"total adjustment. Adjut;n76Rang° Hale in ceding (2)Other finishes and colors are available on special order. [34.76mm] 2 19/64"Did. Consult factory for details. [56.34mm] Nominal Position I Sprinkler of Coverplote Cup Assembly Standard Temperature Ratings Coverplote Sprinkler Cover Plate Max. suing Assembly Classification Temperature Temp Rating Ambient — cem� . 9� Rating Temp. 3/16"[4.76mm] Coverplote AdjustmentOrdinary 135°F (57°C) 135°F (57°C) 100°F (38°C) 3/16"[4.76mm] Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Coverplote Adjustment 3 5/16•Di.. Intermediate t'j 175°F (79°C) 165°F (74°C) 150°F (66°C) 3/6"[9.53mm] [64.13mm] ment Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) Totes Adjust 15lFC°i-c Hight') 286°F(141°C) I 165°F (74°C) I 150°F (66°C) Fig.4 Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Note: Do not install the Model F3OR Dry Concealed Pendent Sprinkler brass and recommended for interior applications. in ceilings which have positive pressure in the space above. (')Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A"Dim. 31b"to 48" 89mm to 1219mm)in 1/4"(6mm)increments Finishes S rinkler Escutcheon Collar Inlet Protrusion Elevated czzz� —j- --jyr�=-'o Above Inside Pipe - Chrome Plated Chrome Plated Chrome Plated White Polyester(2) White White (1)Other finishes and colors are available on special order. System Tee Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or 163 s0-1 1'NPT Mite. Hole in Ceiling 1 75/16" "A" Dimension [49.2mm] Standard Temperature Ratings Ad;uat 1/4Range i [36.35mm] 75/18" Sprinkler Max. Nominal Position [23.6mm of Escutcheon Sprinkler Classification Temperature Ambient Bulb Color Cup Assembly Rating Temp. VL44Cenin9 1/6" Ordinary 135°F (57°C) 100°F (38°C) Orange ce_i""9� [3.2mm] Ordinary 155°F (68°C) 100°F (38°C) Red Esoafceo`6Adjuatment Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow 1/4"[6.35] Intermediate 200°F (93°C) 150°F (66°C) Green Escutcheon Adjustment --se. High(1) 286°F(141°C) 225°F(107°C) Blue '/Adjustme fm] 2 27/32- 157FOW [72.2mm] Listed and Certified only by cULus. Fig.5 Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 3. Model F3QR Dry Horizontal Sidewall Sprinkler "A"Dim. 1 2"to 48" 51 mm to 1219mm in 1/4" 6mm increments Finishes"' Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Bronze Brass(3) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Ratin Tem . White Pol ester(2) White Ordinary 135°F (57°C) 100-F (38aC) Orange (1)Other finishes and colors are available on special order. Ordinary 155°F (68aC) 100°F (38°C) Red Consult factory for details. Intermediate(1) 175aF (790C) 150OF (66°C) Yellow (21 cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate 200-F (93-C) 150-F (66aC) Green White. I Hi h 286°F 141°C 225°F 007C Blue (3)Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. 1 1/2" [38.10mm] (1)Listed and Certified onlyb cULus. Total Adjustment _ — y r� r Ceiling --------------I 1'[25.4mm]I=r TotOI Adjustment 4• [101.60mm] Min. _--__—_-_Ceiling_--_--� 72"[304.80mm] Max. r t 1/4� [31.75mm] t/2"[72.7mm] T Escutcheon Adjustment Escutcheon Adjustment' 4•[101.60mm]Min. f'-^] �-- 1/4• [6.35mm] t4"[304.60mm]Max. System lee II Escutcheon Adjustment 1/2'[12.7mm] 1, NPT Eeeutche0n Adjustment 2 3/32• \\ 11\ 2 3 32- c System Tee [53.18mm] [53.18mm] \ 1"NPT i ' q\r ICJ 11 _ — %^ [76.20mm] _—____ — _ [55.88 [BB.B/2]--1J • -iA oio. Escutcheon'No. 2 2 t/2" D 1/8• Oil. I c iO. [53.98mm] ;1 [63.5mm] Hole in Wall L"•J 1/4•[6.35mm] Hole in Woll 1_1/4•[31.75mm]Nominal Sprinkler Co Protrusion Prot..'.- Fp'kler Con •A" Dimension LA•gmandOn FxutcMon Adjustment Nominal Position Adjustment No final Position of Escutcheon Ronge+ 1/2"[+12.7mm] of Escutcheon rs.ucw-D Range - 1/4• [-6.35mm] ,�,.co.r - 1/2'[-12.7mm] rvFca-D + 1 1/4 [+31.75mm] Fig. 6 Fig. 7 Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal Note: The sprinkler can protrudes 1'/4" when escutcheon is in nomi- position. Escutcheon adjustment provides'/4"(-6mm)to +11/4" nal position. Escutcheon adjustment provides'/2"(-12.7mm)to (+32mm)"A"dimension adjustment range. +1/2"(+12.7mm)"A"dimension adjustment range. Sprinkler Installation Wrench: Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5734 Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A"Dim. 31/z"to 48" 89mm to 1219mm in 1/4"(6mm)increments G;Iing Finishes(" 1 13/32' Eseutcneon [35.7mm] Sprinkler Escutcheon 4'[101.6mm]Min. Bronze Brass Sy.eem T°° c°° 12'[304.6mmjM0°.* Chrome Plated Chrome Plated NPT White Polyester(2) White ;;= -" (1)Other finishes and colors are available on special order. 3[7/82m Consult factory for details.Cup remainds unfinished."See page 2" J•�-�==—tom 2,/z•Dio. 1 (2) cULus Listed as a Corrosion Resistant sprinkler in-standard Black or �.5mm White. Hde in Well Nominal Position 11t11 2 1s/64•D'a. 01 Escutchean [58.3mm] 1/4'[6.35] Standard Temperature Ratings Fsextehwn 'C,2.7 nt AdiurtmanlnRan ,/2'[,2.7mm] 4•" a heo E—tcn M —t Classification Sprinkler Tel Max. Bulb Color cka.35m�m] 1/4'[6.35] 1u Fxuteheon Adjustment refute Rating Ambient Temp. yr.FOR FACTORY MUTUAL(Fu) Ordinary 135-F (57°C) 100°F (38eC) Orange 4'-6'FOR UNDERWRITERS LABORATORIES(UL) Ordinary 155°F (68°C) 100°F (38°C) Red Fig. 8 Intermediate(1) 175oF (79aC) 150°F (660C) Yellow Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Intermediate 200-F (93°C) 150°F (660C) Green Sidewall Sprinkler in walls which have positive pressure in their High(1) 286°F 141°C 225°F 107°C Blue I side space. • Listed by cULus for Quick Response. Approved by FM for (')Listed and Certified only by cULus. Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus Sprinkler Installation Wrench: for installation of min.4"(100mm)-to-max.6"(1 50mm)below Model G3 R/C Sprinkler Wrench ceiling and approved by FM for installation of min.4"(1 00mm) Sprinkler Identification Number(SIN): R5734 -to-max.12"(300mm)below ceiling. 4. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A"Dim. 31/2"to 48" 89mm to 1219mm in Y4" 6mm incrementsFinishes... —..Deiin9 Escutcheon [3.2mm] i S rinkler Escutcheon Collar r_� Sprinkler Cup 4 [101.6mm]M..*, Chrome Plated Chrome Plated Chrome Plated 5n`°m T°° Assembly 3 z [3o4.emm]Ma.. White Polyester(2) White White I'NRT �- (1)Other finishes and colors are available on special order. /;;;{`,``e Consult factory for details. ;r j," z v/3z] [7z.zmm (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. z 1/2'ova. I [63.5mm] Standard Temperature Ratings Male,n Wall !3 P 9 Nominal Position 1 15/16' of Escutcheon [49.2mm] Sprinkler Max. 1/4'[6.35] Escutcheon Adjustment Classification Temperature Ambient Bulb Color •A•Dimension 1/2- [12.7mm] Rating Temp. 157FG07A Adjustment Range Adjustment [i6.35mm] 1/4-[6.35] Ordinary 135-F (57'C) 100-F (38'C) Orange .. FOR FACTORY MUTUAL(FM) Escutcheon Adjustment Ordinary 155-F (68aC) 100-F (38'C) Red 4-— 6•FOR UNDERWRITERS LABORATORIES (UL) Intermediate(1) 175'F (79'C) 150'F (66'C) Yellow Intermediate 200-F (93'C) 150-F (66'C) Green Fig. 9 High(1) 286-F(141'C) 225'F(107'C) Blue Listed by cULus for Quick Response.Approved by FM for Standard Response. ')Listed and Certified only by cULus. • Recessed Horizontal sidewall sprinklers are listed Sprinkler Installation Wrench: with cULus for installation of min. 4" (100mm) - to Model G3 R/C Sprinkler Wrench -max. 6" (150mm)below ceiling and approved by Sprinkler Identification Number(SIN): R5734 FM for installation of min.4"(100mm)-to-max. 12" (300mm)below ceiling. Technical Data: Ordering Information Orifice Size: '/2" (15mm) Specify: Thread Size: 1" NPT per ANSI B2.1 1. Sprinkler Type (select one): Working Pressure: 175 psi(12 bar) (a)Model F3QR Dry Pendent Nominal K Factor-US/(Metric): 5.6/(80) (b)Model F3QR Dry Pendent/HB Product Description (c)Model F3QR Dry Recessed FP Pendent Reliable Model F3QRDrySprinklersare quick response sprinklers (d)Model F3QR Dry Recessed F1 Pendent utilizing a durable 3mm frangible glass bulb. This quick response (e)Model F3QR Dry Concealed Pendent enables these sprinklers to apply water to a fire much sooner than (f)Model F3QR Dry Horizontal Sidewall standard response sprinklers of the similar temperature rating. (g)Model F3QR Dry Horizontal Sidewall/HB Model F3QR Dry Sprinklers are intended for use in dry and preac- (h)Model F3QR Dry Recessed FP Horizontal Sidewall ton systems and in areas sub]ectedto freezing temperatures,such (i)Model F3QR Dry Recessed F1 Horizontal Sidewall as freezers and unheated portions inside and outside buildings. 2. Sprinkler Temperature Rating. Environments wherein dry sprinklers are employed can be cor- 3. Sprinkler Finish. rosive.For this reason,Model F3 Sprinklers have a special wax fillet 4. Escutcheon type (F1 or FP). placed in the gap between the cup that supports the bulb and the 5. Cover Plate/Escutcheon Finish. wrenching bass.This wax will not interfere with the operation of the 6. Length: sprinkler, and it prevents contaminents from entering the internal "A"Dimension(face of tee to face of ceiling or wall)in portion of the drop nipple.The wax must not be removed. (6mm)increments. Operation 7. Model F3QR Dry Pendent (a) is available without The glass bulb consists of an accurately controlled amount of sprinkler can and escutcheon. special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide Note: fast thermal response. When the temperature increases sufficiently, 1. The "A" dimension is based on a nominally gauged due to a fire,the bulb shatters allowing operating parts to clear the pipe thread "make-up" of 0.600" (15mm) per ANSI waterway. This enables the inlet seal to release air or water and 132.1 [71/2 threads approximately]. subsequently, cause water flow over the deflector in a uniform 2. All platings and paintings are decorative and intend- spray pattern,controlling or extinguishing the fire. ed for interior use. 5. • I. General Installation Instructions Maintenance Model F30R dry sprinklers must be installed only in stan- The Model F3QR Quick Response Dry Sprinklers should dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected quarterly and the sprinkler system maintained pipe tees in the horizontal position,even at branch line ends. in accordance with NFPA 25. Do not remove the factory They should not be installed into elbows or pipe couplings applied thermally sensitive wax fillet between the bulb sup- located on drop nipples to the sprinklers. For these and porting cup and the wrenching boss. Do not replace this other fittings including CPVC', the dry sprinkler should be wax with a substitute substance. An Alternate substance installed into a fitting to allow protrusion into the fitting in ac- may interfere with proper operation of the sprinkler. Do not cordance with the diagrams. The "A" dimension of the dry clean sprinklers with soap and water,ammonia or any other sprinkler, which extends into the freezers or a freezing zone cleaning fluids. Remove dust by using a soft brush or gently from wet pipe systems, should be selected to provide, as a vacuuming. Remove any sprinkler which has been painted minimum,the specified lengths in inches shown in Fig. 10. (other than factory applied)or damaged in any way. A stock Caution: of spare sprinklers should be maintained to allow quick Do not install Model F3QR Dry sprinklers into CPVC replacement of damaged or operated sprinklers. Prior to adapter fittings or tees that have an internal obstruction. installation, sprinklers should be maintained in the original This will damage the sprinkler and/or the fitting. Refer to cartons and packaging until used to minimize the potential Fig. 11. for damage to sprinklers that would cause improper opera- tion or non-operation. During installation, the following steps must be followed: 1. Cut the specified size hole(see illustrations)for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on /thread-off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed In- stallation Instructions • The Model G3 R/C wrench (Fig. 12) is designed to locate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard 1/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model G3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 6. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT AMBIENT TEMPERATURE _ rt_____ _ _ PER ANSI B 16.3 (CLASS 150) TEMPERATURE _-- -�-- *T OR CAST IRON THREADED TEE FITTING OF PROTECTED 40'F/4'C 1 50'F/10'C I 60'F/16'C -1� 1 I � nn PER ANSI 16.4 (CLASS 125) ONLY. AREA-AT THE yr- DISCHARGE END EXPOSED MINIMUM BARREL LENGTH" OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) - IN. MM IN. (MM) IN. (MM) 11J IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40-F(VC) 0 0 0 r CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED 30-F(-1'C) 0 0 0 I BARREL WITH INSULATION, FOAM INSULATING 20-F(-7'C) 4 (101) 0 0 TAPE OR EQUIVALENT. i 10-F(-17C) 8 (203) 1 (25.1) 0 O'F(-18'C) 12 (305) 3 (75) 0 MINIMUM (HEATED AREA) I SEAL THE CLEARANCE SPACE -10-F(-23'C) 14 (356) 4(101) 1 (25.1) EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE [IF AIR INTO THE PROTECTED -20-F(-29'C) 14 (356) 6(152) 3 (75) LENGTH AREA AND CONSEQUENT FORMATION OF -30'F(-34'C) 16 (408) 8 (203) 4(101) I CONDENSATE AROUND THE FRAME, WHICH LOUL➢ INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR -40'F(-40'C) 18 (457) 8 (203) 4(101) RECOMMENDED'A' CLEARANCE METHODS. -57F(-46'C) 20 (508) 10 (254) 6 (152) DIMENSION HOLE -60-F(-51'C) 20 (508) 10 (254) 6 (152) •THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. i THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. --THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. ESCUTCHEON NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 3OMPH CEILING WIND VELOCITIES IN THE PROTECTED AREA. (PROTECTED AREA) DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE _----------1 rt 1 ---- -------- -41- 4p i__ ' _''''II L J L J (HEATED AREA) i MINIMUM I (HEATED AREA) MININUN EXPOSED I EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING INSIDE FACE SEAL LENGTH (SEE ABOVE RASCO #4003910 I (SEE ABOVE) (RECOMMENDED) i CLEARANCE HOLE i INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING (PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) DRY SPRINKLER IN COLD AREA IN COLD AREA Fig. 10 7. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNNO OBSTRUCTION INTERNAL OBSTRUCTION I I FEMALE I FEMALE PIPE PIPE THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL-LINE OF MODEL F3-PL, MODEL F3QR-PL, AND MODEL DH56 HSW-PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD I MODEL F3-PL, STANDARD MODEL F3QR-PL OR MODEL F3, MODEL DH56 HSW-PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 015fg08 Fig. 11 8. � �$ Fig. j2-Ga±C Wench Fig. ]S-GSR/C Wrench Fig. l4-GaSC Wench �\^ \ } B& is-Ga Wrench 9. BRANCH OUTLETS FIG. 7045 CLAMP-T FLOW DATA Clamp-T, FPT Branch (FRICTIONAL RESISTANCE) Branch Size FIg.7045 Threaded Branch Inches C.V.Value Equiv.Pipe 4 The Gruvlok Clamp-T provides a quick and easy outlet at any Length Feet location along the pipe.A hole drilled or cut in the pipe to receive Uwmm Meters the locating collar of the Clamp-T is all that is required.The full, '/Z 22 1.0 smooth outlet area provides for optimum flow characteristics. ' e.s /4 25 2. The Clamp-T housing is specially engineered to conform to the pipe 2 - 0.6 O.D.and the Clamp-T gasket providing a leak tight reliable seal in 1 44 2.0 both positive pressure and vacuum conditions.The maximum a.s 1'/< 76 2. working pressure for all sizes is 500 PSI(34.5 bar)when assembled tt_a on standard wall steel pipe. L21/2 89 4.0 ;M- 12 The Gruvlok Clamp-T provides for a branch or cross connection in a...r...�.M.� :.,�.,_ 164 3.5 light wall or standard wall steel pipe. r The Fig.7045 Clamp-T female pipe thread branch is available with NPT or ISO 7/1 connection and 152 12.5 the Fig.7046 Clamp T has grooved-end branch connection. 3.8 3 318 8.5 Clamp T cross connections are available in various sizes allowing greater versatility in piping design. I a6 4 536 8.0 NOTE:Variable End Configurations are Possible— 100 - 2.4 Thd x Thd and Gr.x Thd. Sizes—Z'x'/2"through 8"x 4" MATERIAL SPECIFICATIONS � ANSI BOLTS&HEAVY HEX COATINGS: Heat treated,oval neck track head bolts conforming to ASTM A 183 ❑Rust inhibiting paint Color:ORANGE(standard) Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex ❑Hot Dipped Zinc Galvanized(optional) nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B,or ❑Other Colors Available(IE:RAL3000 and RAL9000) J995 Grade 2.Bolts and nuts are provided zinc electroplated as standard. For other Coating requirements Contact a Gruvlok Representative for METRIC BOLTS&HEAVY HEX NUTS: more information. Heat treated,zinc electroplated oval-neck track head bolts made of GASKETS:Materials carbon steel with mechanical properties per ISO 898-1 Class 8.8.Hex Properties as designated in accordance with ASTM D 2000 nuts are zinc electroplated followed by a yellow chromate dip. J Grade"E"EPDM(Green color code) LJ-BOLT: -40°F to 230°F(Service Temperature Range)(-40°C to 110°C) Cold drawn steel and zinc plated. i Recommended for water service,diluted acids,alkalies solutions,oil- free air and many chemical services. STAINLESS STEEL BOLTS&.NUTS: NOT FOR USE IN PETROLEUM APPLICATIONS. Stainless steel bolts and nuts are also available.Contact a Gruvlok Representative for more information. J Grade"T"Nitrite(Orange color code) HQUSIN -20°F to 180`F(Service Temperature Range)(-29°C to 82°C) Ductile Iron conforming to ASTM A 536,Grade 65-45-12 or Malleable Recommended for petroleum applications.air with oil vapors and vegetable and mineral oils. Iron conforming to ASTM A 47,Grade 32510. NOT FOR USE IN HOT WATER OR HOT AIR. LUBRICATION: ❑Standard Gruvlok ❑Gruvlok XtremeT""(Do Not use with Grade"C) PROJECT INFORMATION APPROVAL Project: ❑Approved Address: ❑Approved as noted Contractor: ] Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: 12/08 BRANCH OUTLETS ()Amm Y Z Y I �Z� Clamp-T, FPT Branch T V T ' -�- -� W 1 Fig.7045 U I Fig.7045(U-Bolt) FIGURE e45-FPT BRANCH(TABLE CONTINUES TO NEXT PAGE) Hole Dimensions ♦Max. Clamp-T Dimensions Specified Torque§ Approx. Nominal Size O.D. Working Bolt Size Min,Diameter Max.Diameter pressure T U v Threaded W Y qi�16 Min. Max. Wt.Each In,%DNimm) in./mm O./mm In.1mm PSIPoar inlmm in.,mm In"Mm In.tmm tn.%mm In.1mm R-l.ba'N-m tks.4lg 2 x'/z 2.375 x 0.840 1 Yz F% 500 2/1e 9i1e 2'/8 %2 57z %z U-Bolt 30 40 2.3 50 x 15 60.3 x 21.3 38 41 34.5 56 14 67 12 140 7.O 2 x% 2.375 x 1.050 1'/2 1% 500 2Yie V16 2Ye 1%2 5%z 3 %2 U-Bolt 1 30 40 2.3 5O x 20 60.3 x 26.7 38 41 34,5 52 14 67 1 38 140 1 76 1.0 20 1 2.375 x 1.315 1'/2 1Ye 500 VVIia Y16 2% 1 Y2 5Y2 3 V2 U-BOft 30 40 2.6 50 x25 60.3 x 33.7 38 41 34.5 51 14 67 38 140 76 1.2 2 x 1'/4 2.375 x 1.660 2 2'/e 500 Via Via 27/e 1%2 5% 3'/z /z U-Bolt 30 40 2.7 50 x 32 60.3 x 42.4 51 54 34.5 55 14 73 38 140 89 - 1.2 2 x 1'/2 2.375 x 1.900 2 2'/e 500 2'/1a 1/16 27a 1%2 7 3'/2 %2 U-Bolt 30 40 2.5 50 x 4O 60.3 x 48.3 51 54 34,5 55 14 73 38 1 178 89 1.1 21/2 x 1/2 2.875 x 0.840 1 Y2 1 Ya 500 27/1a Via 27/e 1 V4 5'/2 3 /2 U-Bolt 30 40 3.0 65 x 15 73.0 x 21.3 38 41 34.5 62 14 73 44 140 1 76 1.4 21/2 x% 2.875 x 1.050 1'/z 1% 500 2%6 Via 27/e 1 Y4 5%z 3 '/2 U-Bolt 30 40 2.9 65 x 2O 73.0x26J 41 34.5 5;9 14 73 44 140 76 - 1.3 2'/2 x 1 2.875 x 1.315 1'/2 15/e 500 2Y16 Y16 2% 1 Y4 6'/e 3 %2 U-Bolt 30 40 2.9 65 x25 73.0 x 33.', 38 41 34.5 55 14 73 44 156 76 1.3 2'/2 x 1'/4 2.875 x 1.660 2 2'/s 500 2%6 %s 3Ye 1 Y/4 6'/e 3% %2 U-Batt 30 40 3.4 65 x 32 73.0 x 42.4 51 54 34.5 62 14 79 44 156 86 1.5 2'/2 x 1'/2 2.875 x 1.900 2 2Ye 500 27/16 Y16 3Ye 1 Y4 6'/a 3% '/2 U-Bolt 30 40 3.4 65 x 40 73,0 x 48.3 51 .54 34.5 62 14 79 44 156 86 1.5 3 x Y2 3.500 x 0.840 1 V2 1 Ye 500 26/i6 Y16 3 2Ye 7 3% '/2 U-Bolt 30 40 2.8 80 x 15 88.9 x 21.3 38 41 34.5 65 14 76 54 178 95 1.2 3 x Y4 3.500 x 1.050 1 Y2 1 Ye 500 27/16 Yie 3 2Ye 7 3% '/2 U-8011t 30 40 2.7 80 x 20 88.9 x 26.7 38 41 34.5 62 14 76 54 178 95 1.2 30 1 3.500 x 1.315 1'/2 1% 500 2Y16 Y16 3 2Ye 7 3Y4 '/2 U-Bolt 30 40 2.7 8Ox25 88.9x33.7 38 41 .34.5 59 14 76 54 178 95 1.2 3 x 11/4 3.500 x 1.660 2 2'/s 500 2'Y16 1'/2 3% 296 67/e 3Y4 '/2x 2% 80 100 3.4 80 x 32 88.9 x 424 51 .54 34,5 1 68 38 86 54 175 95 1.5 3 x 1'/z 3.500 x 1.900 2 2'/e 500 21'/16 1 Yz 3% 2% 61/e 3% /2 x 2% 80 100 4.4 BO x 40 88.9 x 48.3 51 54 .34.5 68 38 86 54 175 95 20 3 x 2 3.500 x 2.375 2Y2 2% 500 2'Y1a 1'/2 3Ye 2Ye 67/s 4'/a /2 x 2Y/4 80 100 4.6 BO x 50 88.9 x 60.3 64 67 34.5 68 38 86 54 175 105 2'1 4 x'/2 4.500 x 0.840 1%z 1% 500 3Yi6 Y16 3'/2 2% 7Y/4 3% 'A U-Bolt 30 40 2.9 100x 15 114.3x 21.3 38 41 34.5 76 14 89 67 197 1 .95 1.3 4 x Y4 4.500 x 1.050 1 Y2 1% 500 3'/1a Vie 3'/2 2% 7% 3Y4 '/2 U-Bolt 30 40 2.8 100 x 20 114.3 x 26.7 38 41 1 34.5 78 14 89 667 197 95 7.3 40 1 4.500 x 1.315 1'/2 1% 500 2'Yie Vie 3'/2 2Ye 73/4 3% Y2 U-Bolt 30 40 2.7 100 x 25 114.3 x 33.7 38 41 34.5 73 14 89 67 197 95 1.2 4 x 1'/4 4.500 x 1.660 2 2'/e 500 3Yh6 17a 3% 2% 7'/2 3% /2 x 2% 80 100 4.5 100,02 114.3 x 42.4 51 54 34,5 81 48 98 67 191 95 20 4 x 1'/z 4.500 x 1.900 2 2'% 500 3Yi6 1'/e 37/e 2% 7'/2 3% /2 x 2% 80 100 4.6 100 x 40 114.3 x 48.3 51 54 34.5 81 48 98 67 1 191 95 2.1 4 x 2 4.500 x 2.375 2'/z 2% 500 3Yi6 17/e 4 2% 7%2 41/e '/2 x 2% 80 100 7.7 70O x 50 114.3 x 60.3 64 67 34.5 84 48 102 67 191 705 3.5 4 x 2'h 4.500 x 2.875 2% 2% 500 311/4 17/e 4 2% 7'/2 4% /2 x 2% 80 100 5.2 100 x 65 114.3 x 73.070 73 34.5 78 48 102 67 191 111 24 4 x 3 O.D. 4.500 x 2.996 2/1 2;4 Soo 3 17 y 4 2% T/z Iri is x 24 80 100 5.2 100 x 80 114.3 x 76.1 70 73 34.5 76 48 102 67 191 111 2.4 40 3 4.500 x 3.500 3'h 3% 500 3'/4 1% 4'/4 2% 7'/z 5'/4 '/2 x 3'/2 80 100 6.5 100 x 80 114.3 x 88.9 89 92 34.5 83 48 108 67 191 133 2.9 NOTE:2h",5"and 6"Nom.Run pipe sae Clamp-T may be used on 3"O.D.,5'h"O.D.and 6%"O.D.pipe (Additional larger sizes an nmd page.) V Based on use with standard wall pipe. Not for use in copper systems. See Installation&Assembly directions on page 156. §-For additional Bolt Torque information,see page 178. 12108 _ _ I BRANCH OUTLETS FIG. Y Z Y Z.., _ Clamp T, FPT Branch �-T iI I T i V V T i -�- -� I w '// _.: ' Fig.7045 I U I Fig.7045(U-Bolt) FIGURE e•5-FPT BRANCH(CONTINUED FROMPREVIOUS Hole Dimensions ♦Max. Clamp-T Dimensions Specified Torque§ Approx. Nominal Size O.D. Working Bolt Size Min.Diameter Max.Diameter pressure T U V Threaded W Y 731/� Min. Max. Wt.Each InfiNlmm) In.lmm In.lrnm In.lmm PSt/bar In.knm In.imm fn.tmin In✓mm lahnm 1nlmm Ft.-tbsvN-m Lbsaxg 5 x 1'/4 5.563 x 1.660 2 2'/a 500 31'Afi 1%a 4a/a 3'/ 9%'a %x 3%4 100 130 5.4 12-,5 x 32 141.3 x 42.4 51 54 34[+ 94 48 111 83 232 2,4 5 x 1'/2 5.563 x 1.900 2 2'/a 500 TYle 1'/e 4% 3'/4 9'/e 3% Ye x 3'/4 100 130 5.5 125 x 40 141.3 x 46..3 51 54 34.5 94 48 11l 83 232 95 - 2.5 5 x 2 5.563 x 2.375 21/2 2% 500 3"/,e 1'/a 4'/2 3'/4 9'/s 4'/e %x 3'/4 100 130 5.7 125 x 50 141.3 x 60.3 64 67 34.5 97 48 114 83 232 105 2.6 5 x 2'/2 5.563 x 2.875 2e/4 2'/e 500 3%6 1'/e 4'/4 3'/4 9Ya 4% %x 3'/4 100 130 7.0 125 x 65 141.3 x 73.0 70 73 34.5 97 48 121 83 232 711 3.2 5x30.0. 5.563 x 2.996 2'/ 2' 500 3'/ i'1 4% 3'/ 974 4/1 I/.x F4 130 180 7,0 125 x 80 141.3 x 76.1 70 73 34.5 95 48 121 83 232 111 - 3.2 5 x 3 5.563 x 3.500 3'/2 3% 500 4 17. 5 3'/4 9%a 5'/4 %x 3'/4 1 w 130 8.7 125.x 80 141.3 x 88.9 89 92 34.5 102 48 127 83 232 133 3.9 6 x 1'/4 6.625 x 1.660 2 2'/e 500 011e 2 4% 3'/e 10'% 3% Ys x 4'/4 100 130 7.8 150 x 32 168.3 x 42.4 51 54 34.5 106 51 124 98 257 95 ?.5 6 x 1'/2 6.625 x 1.900 2 2'/s 500 43/e 2 4Vs 3'/e 10'/e 3% 5/a x 4'/4 100 130 7.8 150 x 10 168.3 x 48.3 51 ,4 34.5 106 51 124 98 257 95 - 3.5 6 x 2 6.625 x 2.375 2'/2 2%8 500 011a 2 4'/e 3'/a 10% 4'/e %s x 4'/4 100 130 7.8 150 x 50 168.3 x 60.3 64 67 34.5 106 51 124 98 257 105 - 3.5 6 x 2'h 6.625 x 2.875 2% 2Ve 500 4e/is 2 5'/s 3'/s 10'/e 4% Ya x 4'/4 100 130 8.4 150 x 65 168.3 x 73.0 70 73 34.5 106 51 130 98 257 Ill - 3.8 6 x 3 0.D. 6.625 x 2.996 0/1 21/3 500 41h 2 5ri 314 10ij Ph %x 4'/+ 100 130 8.4 150 x 80 168.3 x 76.1 70 73 34.5 105 51 130 98 257 111 - 3.8 6 x 3 6.625 x 3.500 31/2 3e/a 500 4% 2 5a/e 3'/a 10'/a 51/4 %x 4'/4 100 130 9.6 150 x 80 168.3 x 88.9 r;) 92 34.5 Ill 51 137 98 257 133 - 6 x 4 6.625 x 4.500 4%2 4% 500 4% 2 5'/2 3% 10'/e 6Y2 Ye x 4% 100 130 10.5 150 x 100 168.3 x 114.3 114 117 34.5 Ill 51 140 98 257 165 - 4.8 8 x 2 8.625 x 2.750 2'/2 2% 500 5Yle 2'/4 5'/e 5 12Y4 4'/e '/4 x 4'/4 130 180 11.3 200.x 50 219.1 x 70.0 64 67 34.5 132 57 149 127 324 105 - 5.1 8 x 2'/2 8.625 x 2.875 2%4 27/e 500 5% 2'/4 6'/4 5 12'/4 4Ys %x 4'/2 130 180 11.1 200 x 65 219.1 x 73.0 71) 73 34.5 134 57 159 127 324 ill - 5.0 8x30.0. 8.625x29% 714 2A 500 5/ 2.4 6%4 5 121% 4'/e 'i.x4Sr 130 180 11.1 200 x 80 219.1 x 76.1 70 73 34.5 133 57 159 127 324 111 - 5.0 8 x 3 8.625 x 3.500 3'/2 3Ye 500 5Y, 2'/a 6% 5 12%4 5'h '/4 x 4%2 130 180 13.0 200 x 80 219.1 x 86.9 89 92 34.5 137 57 162 127 324 133 5.9 8 x 4 8.625 x 4.500 4'/2 4a/e 500 5% 2'/4 6'/2 5 12% 6'/2 Y4 x 4'/2 130 180 16.2 200 x 100 219.1 x 714.3 1 114 117 34.6 137 57 165 127 324 165 7.3 NOTE 2'/2".5 and 6"Nom.Run pipe size Clamp-T may be used on 3"O.D.,516"O.D.and 6'/2"O.D.pipe (Additional smaller sizes on previous page.) V Based on use with standard wall pipe. Not for use in copper systems. See Installation&Assembly directions on page 156. §-For additional Bolt Torque information,see page 178. 12108