Ventilations Compliance:
Whole House Ventilation system Whole House Ventilation
using exhaust fans Integrated with a Forced Air
System
ther,describe:
Instructions:This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed.Based on the size of the structure,the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and
Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits.
Marine 4(Table R402.1.3)
Fenestration U-Factor b,1 0.30
Skylight U-Factor b 0.50
Ceiling R-Value a 60
Wood Frame Wall R-Value 9i 20+5 or 13+10
Floor R-Value 30
Below Grade Wall`b 10/15/21 int+TB
Slab d,f R-Value&Depth 10,4ft
R-values are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design
thickness of the insulation,the compressed R-value of the insulation from Appendix A Table A101.4 of chapter 51-11C WAC shall not be less
than the R-valuespecified in the table.
b The fenestration U-factor column excludes skylights.
"10/15/21+STB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R-
C 21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall."10/15/21+STB"shall
be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or
exterior of the wall."STB"means R-5 thermal break between floor slab and basement wall.
d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.29.1.
For single rafter orjoist vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth extends over the top plate
of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied
f to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall meetthe requirements for thermal barriers protecting foam
plastics
For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for
a climate zone 5 of ICC 400.
Prescriptive Path—Single Family 2021 Washington State Energy Code-R
Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard framing 16 inches on
h center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation.
The first value is cavity insulation,the second value is continuous insulation.Therefore,as an example,"R13+10"means R-13 cavity
insulation plus R-10 continuous insulation.
i A maximum U-factor of0.32 shall apply to vertical fenestration products installed in buildings located above 4000 feet in elevation above
sea level,or in windborne debris regions where protection of openings is required under Section R301.2.1.2 of the International
Residential Code.
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2(Energy
Equalization credits)and Table 406.3(energy credits)to achieve the following minimum number of
credits.To claim this credit,the building permit drawings shall specify the option selected and the
maximum tested building air leakage and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit:5 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit:8 credits
All dwelling units that are not included in#1 or#3
3. Large Dwelling Unit: 9 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet:2 credits
All other additions shall meet 1-3 above.
- Summary of Table 11406.2
System
Type Energy Equalization Credits Credits E )ecf-ONE System Type
-- --- __-- _ ___-- -- Single Family-.. ;
-- ----- -
1 For combustion heating equipment meeting
i minimum federal efficiency standards for the 0.0 ❑
equipment listed in Table C403.3.2(5)or C403.3.2(6)
f2 I For an initial heating system using a heat pump j I
Ithat meets federal standards.for the equipment
listed in Table C403.3.2(2)and supplemental 15 ❑ I
i heating provided by electric resistance or a i
combustion furnace meeting minimum
standards listed in Table C403.3y2(5)b
3 For heating system based on electric resistance only ! I
(either forced air or Zonal) 0.5 ❑
4` For heating system using a heat pump that meets -
j federal standards for the equipment listed in Table
C403.3.2(2)or C403.3.2(9)or Air to water heat pump 3.0 !
units that are configured to provide both heating and.
cooling and are rated in accordance with AHRI
550/590
I
5 For heating system based on electric resistance with
I
1. Inverter-driven ductless mini-split heat pump j
system installed in the largest zone in the dwelling,o, 2"0 ❑
12.With 2kW or less total installed heating capacity j
per dwelling
1b.The gas back-up furnace will operate as fan-only when the heat pump is operating.The beat pump shall operate at all temperatures above 38'F
I(33`C)(or lower).Below that"changeover"temperature,the heat pump would not operate to provide space heating.The gas furnace provides heating I
below 38'F
(3.3"C)(or lower).
F.Additional points for the HVAC system are included in Table R4063.
Prescriptive Path—Single Family 2021 Washington State Energy Code-R
♦1
En
Energy Credit Option DescriptionsPlease indicate* :-' .
Options chosen credit Details
11 Efficient Building Envelope 0.5
1:2 Efficient Building Envelope _-- 1.0 --
1.3 Efficient Building Envelope 1.5
1.4 Efficient Building Envelope 2.5
2.1 Air Leakage Control and Efficient Ventilation ( 1.0 X
2.2 Air leakage Control and Efficient Ventilation 1.5
! 2.3 Air Leakage Control and Efficient Ventilation 2.0 1
1 3.13 High Efficiency HVAC 1.0
High Efficiency HVAC 0.5 iv
i 3.3'4d High Efficiency HVAC 0.5 1�
3.4'•d High Efficiency HVAC 1.5
3.5 d High Efficiency HVAC 1.5
1 3.6' N High Efficiency HVAC 1.0 1
3.7°de HughEffiaenc�HVAC 2.0 s
I- 3`.8',d High Efficiency HVAC 1.0
i E
3.9 High Efficiency HVAC 1.5
3.101 High Efficiency HVAC 2.5
3.11` High Efficiency HVAC _ ( 0.5
4.1 High Efficiency HVAC Distribution System 0.5 I X
5.1d !Efficient Water Heating 0.5
5.2 i Efficient.Water Heating _ O.S
5.3 ;Efficient Water Heating 0.5
5.4 Efficient Water Heating_ 1.0
5.5 i Efficient Water Heating 1.5 j f
' 5.6 j Efficient Water Heating j 2.0
S.7 Efficient Water Heating 2.5 i
5.8 i Efficient Water Heating 2.5 j
6.1 Renewable Electric Energy(3 credits max) 1.0
7.1 iAppliance Package OS
i
Credits
T f
its I
a. An alternative heating source sized at a maximum of 0.5 Watts/ft2(equivalent)of heated floor area or 500 Watts,
whichever is bigger,may be installed,in the dwelling unit.
b. See Section R401.1 and residential building in Section R202 for Group R-2 scope.
c. Option 3.11 can only be taken with Options 3.1'and 3.3.To qualify to claim Option 3.11 with 3.3,the system shall be a 1-2 speed
heat pump system.Variable capacity heat pumps are ineligible from claiming this option.
d. This option may only be claimed if serving System Type 4 or 5 from Table R406.2.
e. Primary living areas include living,dining,kitchen,family rooms,and similar areas.
f. Option 310 may one be taken with Efficient Water:Heating Option 5.1 or5.2.Equipment sizing for space
heating shall be calculated as provided in Section R403.7 with increased capacity to provide a minimum
of 75 percent of peak hot water demand or shall be sized in accordance with approved manufacturer's
specifications or guidance.Supplementary heat for water heating shall be in accordance with Section
R403.5.7
Prescriptive Path-Single Family 2021 Washington State Energy Code-R