Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2024-01171 Roof Solar - BLD Inspections - 11/8/2024
INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2024-01171 PROJECT ADDRESS 497 E MCMICKIN RD SHELTON, WA 98584 PARCEL# 220012490090 PROJECT DESCRIPTION Installation of roof mounted 11.84kW DC solar Photo-voltaic generation system. Valuation is for Building materials and labor only. OWNER DYER LELAND G&CHRISTINE E ADDRESS 497 E MCMICKIN RD PHONE CONTRACTOR NATIONWIDE SOLAR ADDRESS 6407 NE 117TH AVE UNIT B PHONE 800.908.8992 CONTRACTOR LICENSE NATIOS'786CW LENDER INSPECTION INSP DATE Comments INSPECTION INSP I DATE Comments BLD-Final Inspection Gf ` i "$5 Mason County Mason County - Division of Community Development 615 W. Alder St. _ Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2024-01171 ROOF MOUNT SOLAR PANEL- RESIDENTIAL PROJECT DESCRIPTION: INSTALLATION OF ROOF MOUNTED ISSUED: 09/30/2024 11.84KW DC SOLAR PHOTO-VOLTAIC GENERATION SYSTEM. VALUATION IS FOR BUILDING MATERIALS AND LABOR ONLY. EXPIRES: 03/29/2025 SITE ADDRESS: 497 E MCMICKIN RD SHELTON PARCEL: 220012490090 APPLICANT: DYER LELAND G &CHRISTINE E OWNER: DYER LELAND G &CHRISTINE E 497 E MCMICKIN RD 497 E MCMICKIN RD SHELTON,WA 98584 SHELTON,WA 98584 CONTRACTOR: Angobung, Fabian PO Box 821959 Vancouver,WA 98682 8009088992 GENERAL CONTRACTOR'S LICENSE: NATIONWIDE SOLAR License: NATIOS'786CW 6407 NE 117TH AVE UNIT B Expires: 02/19/2026 VANCOUVER,WA 98662 800.908.8992 FEES: Paid Due Final Inspection $80.00 $0.00 State Fee-Residential $6.50 $0.00 Solar/PV Base Fee $30.00 $0.00 Technology Surcharge $1.60 $0.00 Solar/PV Fee $608.00 $0.00 Totals : $726.10 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS Printed by:Brittany King on:10/01/2024 09:40 AM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-01171 The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586,1044/800.422.5623 www.orcaa.org * The installation of solar(thermal or photovoltaic) energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two- 3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. _ _ .._ _. . _ .. ... . ........ . ..... ... . . . . . ........ Printed by:Brittany King on:10/01/2024 09:40 AM Page 2 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. C Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-01171 OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued B � L Contractor or Authorize Agent: Date: D Z� Printed by:Brittany King on:10/01/2024 09:40 AM Page 3 of 3 ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE CONTRACTOR INFORMATION PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR NOTE: DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN A. ALL ELECTRICAL EQUIPMENT,INVERTERS/COMBINER,DISCONNECTS, NAMNV/mE SOLAR MAIN SERVICE PANELS,ETC.SHALL NOT BE INSTALLED WITHIN 3'OF PO BOX 821988 LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD O VANCDUV WA M THE GAS METERS'SUPPLY OR DEMAND PIPING. STRUCIDREIB W DIN WAG NATIOSVBBCW NOTE:*CHECK WITH CITY/COUNTY OR LAND SURVEYOR Z I PROPERTY LINE --263_41 �( OI- -- ---G -� NOTE:THERE IS NO FENCE AND GATE IN THIS PROPERTY ELECTRICAL ELECTRILL.NATIO COLE B OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. 1Y— UBI 6017E m SUPERVISOR:COLE BABBITT 9E,ADBABBICV.�B802 FOR ACCURATE PROPERTY LOCATION. W - Em.O;ee,,,naeola3mmer«�;a.:om,.wm PHOTOVOLTAIC MODULES } I E�`vENP VSUN SOLAR VSUN370-120BMH(37OW) Nation ode,' W 69.37" O ' 1 ry NATIONWIDE SOLAR --A \ 6107 NE 11rn1 AYE.SUtiE B 71'-011 / VANCOWE1)IXIIII 2 � Emsl:getsoOler(�mNE 80Da1�i8m�9ae 120'-0" , I G� ) (N)3/4'OR GREATER EMT/PVC/LFMCMcJ CONDUIT RUN(7/8'ABOVE ROOF) O _ _ OG Nj I N A I VERSION DESCRIPTION DATE REV I I INITIAL RELEASE 00.1h2S2f UR PROJECT NAME � o U M CM r i i t Lu Q o U)o }} (E)STRUCTURE(TYP.) 6 z)�0 Z �ZcO wZ'n0rn0 1 1 0 L)D ONC� I 1 z o18o g�ZQNW o ; WLUO2Z� J F— ,� I LEGEND I j Q Q V) I (E)TREE(TYP.) JUNCTION BOX UM UTILITY METER I 1 I 1 I W ACD 60A FUSED AC DISCONNECT I Z SHEET NAME J MSP MAIN SERVICE PANEL — SOL HOME WAVE SITE PLAN WITH � INV SEt0D00H-US STRING-INVERTER ROOF PLAN 1 W 1 , O — PROPERTY LINE SHEET SIZE CONDUIT ANSI B -------- ---- D_ 11"X 17" ,j SITE PLAN WITH ROOF PLAN PROPERTY LINE f TREES SHEET NUMBER � ti SCALE:3/64"-1'_0„ -263.59' oo (ROOF OBSTRUCTION) PV-1 ♦► �"� MASON COUNTY PERMIT NO. DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext.352 taw Shelton,WA 98584 (360)482-5269 Elma ext. 352 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Leland Dyer NAME: Fabian Angobung, Permit Technician MAILING ADDRESS:497 E McMickin Rd MAILING ADDRESS: PO BOX 821959 CITY:Shelton STATE:WA ZIP:98584 CITWWancouver STATE:WA ZIP:98682 PHONE:(775) 299-8467 CELL: PHONE:(800)908-8992 CELL: EMAIL:leedyer(o),hotmail.COm EMAIL :permitdept@mynationwidesolar.com L&I REG 4NATIOS-786CW-UBI:604780695EXP.07 /31 /2025 EXP:2/19/2026 ——— PARCEL INFORMATION: 220012490090 PARCEL NUMBER(12 DIGIT NUMBER): LEGAL DESCRIPTION(ABBRE1,7ATED): TR 9 OF SE1/4 NW1/4 TR 4 OF SP#1265 SITE ADDRESS:497 E McMickin Rd CITY:Shelton DIRECTIONS TO SITE ADDRESS:E Harstine Island Rd N.and E McMickin Rd TYPE OF JOB Prescriptive Solar NEW ADD ALT 121 REPAIR OTHER IZI USE OF BUILDING LOCATION OF FIXTURES/UNITS— 1 sT FLOOR 2ND FLOOR BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel 1 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X �a.��rL.Aru�e6ua� 9/26/24 Signature of Applicant �—° Date X Fabian Angobung, Permit Technician Owner/Owners Representativ ontractor Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PHOTOVOLTAIC ROOF MOUNT SYSTEM CONTRACT -R 82 NATIONWIDE 80LAR PO BOX 8219 VANCOWER.ER,WA Tl SIAUCNRE ICA,XNG:NATIOS'19BCW 32 MODULES-ROOF MOUNTED - 11 .840 kWDC, 10.000 kWAC RI =LS EWSOR WLEE UBI.6041. ELECTRICAL SUPERVISOR:COLS"A9&TT 497 E MCMICKIN RD, SHELTON, WA 98584, USA CENSE ADBABBICV B802 Em.e.permeaepl�myrorommes br.com NOTES: : Na �- " 4ttonw(degl► SYSTEM SUMMARY AI l SOLAR♦ (N)32 VSUN SOLAR VSUN370-120BMH(370W)MODULES 1. PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN (N)1 SOLAREDGE HOME WAVE SE10000H-US STRING-INVERTER ACCORDANCE WITH NEC 2023 ARTICLES 690 AND 705,AND THE 2021 I IRCABC&2021 INTERNATIONAL FIRE CODE,AND APPLICABLE (N)JUNCTION BOX REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING (N)32 SOLAREDGE 5440 POWER OPTIMIZERS JURISDICTION.PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED NATIONNADE SOLAR 200A MAIN SERVICE PANEL WITH E 200A MAIN BREAKER _•.�d S/01 NE 111TN.V SNQ UITEB (� ( ) WITH APPLICABLE WARNINGS,SIGNAGE AND PLAQUES PER NEC 690.13, vn"couvER.wA98S9z (N)60A FUSED AC DISCONNECT 705.10 AND 706.15. "-.1� y PHONE:(800)W0 92 2. PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH Errol:pehol,r�mynAtlor,v.WAAobr.mm THE WIRING METHODS AND INSTALLATION AND MARKING REQUIREMENTS OF NEC 690.31(D). 3. BREAKER LABELED"PHOTOVOLTAIC ELECTRIC POWER SOURCE"AND DESIGN CRITERIA "BREAKERS ARE BACK FED"PER NEC 705.12(D)&NEC 690.59.BREAKER ROOF TYPE:ASPHALT SHINGLE ALSO LABELED"MAXIMUM AC OUTPUT CURRENT AND OPERATING AC • NUMBER OF LAYERS:1 VOLTAGE"PER NEC 690.54.BREAKER SHALL BE POSITIONED AT THE '+ ROOF FRAME:2"X4"TRUSSES @ 24"O.0 OPPOSITE(LOAD)END FROM THE INPUT FEEDER OR MAIN CIRCUIT STORY:ONE STORY BREAKER LOCATION,AND LABELED"WARNING INVERTER OUTPUT t SNOW LOAD:25 PSF CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE",PER ,.r��'t "-"} �" VERSION WIND SPEED:110 MPH NEC 705.12(13)(3)(2). � _ .� DESCRIPTION DATE REV WIND EXPOSURE:CRISK 4. WARNING SIGN PER NEC 706.15(C)(4)and NEC 690.13(B)READING COORDITETE:47.I v} - -4" INITIALRELEABE w.tu9u uR COORDINATE:47.250995,-122.880383 'WARNING-ELECTRIC SHOCK HAZARD-TERMINALS ON BOTH LINE AND - LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." tt�` 5. LABEL"PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH."SWITCH INTERCONNECTION METHOD:LINE SIDE TAP TO BE LOCKED PER NEC 690.13(B).SWITCH TO BE VISIBLE BLADE DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC 1 AERIAL PHOTO PROJECT NAME 705.22. 6. LABEL"PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH"PER NEC Pv_0 SCALE:NTS 690.13(B).LABEL WITH OPERATING CURRENT,OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE,AND SHORT CIRCUIT CURRENT PER NEC GOVERNING CODES: 690.53.SWITCH LOCKED PER NEC 690.13(B). I Kent Q 0 2021 INTERNATIONAL BUILDING CODE 7. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER " - L. V)o- r 2021 INTERNATIONAL RESIDENTIAL CODE INVERTER(S)AND SOLAR MODULES PER NEC 110.3(B). _ •+* -- r 2021 INTERNATIONAL MECHANICAL CODE 8. LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER.(NOT USED) ~rn Z 2021 INTERNATIONAL FUEL GAS CODE 9. BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY. "}° Federal Ways Z Duo o 2021 UNIFORM PLUMBING CODE 10. DEDICATED PHOTOVOLTAIC COMBINER SUB PANEL.LABEL"LOADS NOT T6 °' ^ }`L 0 O m O 2021 INTERNATIONAL EXISTING BUILDING CODE TO BE ADDED TO THIS PANEL." Q 167 - 0()T C)N U 2021 INTERNATIONAL FIRE CODE 11. ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND TaCOma 0-Q Z Z 2021 WILDLAND-URBAN INTERFACE CODE ATTACHED PER APPROVED METHOD. 497 E M CM ICI(In Rd, '`� Z 2 3t O cc:,0 2021 WASHINGTON STATE ENERGY CODE 12. LABEL"BREAKER HAS BEEN DE-RATED PER NEC 705.12(B)(3)."NO NEW iI •- U)fV U) 2023 NATIONAL ELECTRICAL CODE Shelton,WA 98584, ' g Z Q`"Q LOADS. r Puyallup Lu w O g Z 2 13. EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE.SOLID LINES 101 United States Lakewood - -11-H D. DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR. j" I j Q 2 14. WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE .� South Q=J SHEET INDEX READS"SUNLIGHT RESISTANT." i Hill H PV_0 COVER SHEET 15. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND �v 0 PV-1 SITE PLAN WITH ROOF PLAN TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC W Elk Plain PV-2 ROOF PLAN WITH MODULES GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B). "Olympia PV-3 ATTACHMENT DETAILS 16. AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO PV-4 ELECTRICAL LINE DIAGRAM SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15(B)(2).CONDUIT TUm ater SHEET NAME PV-5 ELECTRICAL CALCULATION ELEVATED MIN.1I2";ADDER 33 DEG F. PV_6 WARNING LABELS 17. ALL EXTERIOR EQUIPMENT TO BE NEMA 3R. - I - COVER SHEET PV-7 PLACARD 18. THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE PV-7.1 ELECTRICAL PHOTO FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX, - SHEET SIZE PV-8 ADDITIONAL NOTES DISCONNECT AND DEVICE WHERE ENERGIZED,UNGROUNDED CIRCUITS Z. EQUIPMENT SPEC SHEETS MAY BE EXPOSED DURING SERVICE: 2 VICINITY MAP x ANSI B WARNING:ELECTRIC SHOCK HAZARD.THE DC CONDUCTORS OF THIS 11"X 1 T' PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Pv-n SCALE:NTS A H SHEET NUMBER PV-0 ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE CONTRACTOR INFORNAMN PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR NOTE: A. ALL ELECTRICAL EQUIPMENT,INVERTERS/COMBINER,DISCONNECTS WI , NATIONDE SOLAR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN MAIN SERVICE PANELS,ETC.SHALL NOT BE INSTALLED WITHIN T OF ygNPO WX COWER,1096663 LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD I THE GAS METERS'SUPPLY OR DEMAND PIPING. STRucTURE,aUIUNNG:NAnos'7 w OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. I O ELECTRICAL NAn-766TW -263.41 �&R^.M� NOTE:*CHECK WITH CITYICOUNTY OR LAND SURVEYOR PROPERTY LINE NOTE:THERE IS NO FENCE AND GATE IN THIS PROPERTY ELECTRICAL SUPERV SOR:CO E SAfiB FOR ACCURATE PROPERTY LOCATION. W \N ULENSE:ADBABECW 6603 Z G Emel:pem,XEspt®my,uEonwtlamMr.com PHOTOVOLTAIC VSUN SOLAR VSUN370-1P S BMH(370 ) Ndflonwide4► 69.37" --1 SOLAR♦ LU I , I CL 1 0 NATIONWIDE SOLAR �J 6Q7 HE 117TR AVE.SUITE S I 711_ON I / -^ \ VANCOUVER,WA 95661 0eNolerePHONE lrrynetl n�992 Ee obr.mm 1201-0° (N)3/4"OR GREATER EMT/PVC/LFMC CONDUIT RUN(7/8"ABOVE ROOF) /I_// •• I W \ \\ I -lk GN A�L I L� VERSION I o DESCRIPTION DATE REV I I INITIALRELEASE 9F/4MM UR U I I PROJECT NAME o U c+7 co ch W I t I I <a (E)STRUCTURE(TYP.) =F o F- rn L vZo oL)1nLO°N° U I �<z—z I I Z 0cO - I Q W z N I J r`- D_7 .,,...... I LEGEND W F Q 2 Q j r j JB JUNCTION BOX In I (E)TREE(fYP.) � UM UTILITY METER I I I I I W ACD BOA FUSED AC DISCONNECT Z SHEET NAME I I J MSP MAIN SERVICE PANEL SITE PLAN WITH SE10000 GE HOME WAVE � INV SE10000H-US STRING-INVERTER ROOF PLAN W � O — PROPERTY LINE SHEET SIZE ANSI B a CONDUIT 11"X 17" SITE PLAN WITH ROOF PLAN PROPERTY LINE TREES SHE ATTIC FAN ET `NUMBER VENT /-1 SCALE:3/64"=1'-0" -263.59' of OBSTRUCTION(ROOFOBSTRUCTIONrv- MODULE TYPE,DIMENSIONS&WEIGHT ARRAY AREA B ROOF AREA CALC'S BILL OF MATERIALS CSNTRACTORINFORNATION NUMBER OF MODULES=32 MODULES NATIONWIDE S01— MODULE TYPE=VSUN SOLAR VSUN370-120BMH 370 MODULES AREA OF ROOF(PLAN EQUIPMENT OTY DESCRIPTION Po nim ( W) AREA OF NEW ARRAY TOTAL ROOF AREA VANCOIWER.WA 95582 MODULE WEIGHT=46.9 LBS/20.8 KG (Sq.FL) VIEW] COVERED BY ARRAY% RAIL 17 UNIRAC SM RAIL 168"DRK STRUC—DRUI DING:NATIOS988CW MODULE DIMENSIONS=69.37"X 41.26"=19.88 SF (Sq.Ft.) ELECTRICAL.NATIOS-7— UNIT WEIGHT OF ARRAY=2.31 PSF SPLICE 8 BND SPLICE BAR PRO SERIES DRK UBI.8 780998 638.05 3311.34 19.21 ELECTRICAL SUPERVISOR:-LE BABBITT MID CLAMP 52 UNIRAC UNIVERSAL AF SERIES MID CLAMP DARK UCENSE ACBABBICW=' DISTRIBUTED DEAD LOAD=2.71 PSF 19.21% ROOF AREA(ARRAY<33%of ROOF AREA) Eriui:F.mea.MCAmrrew�wacsolxr.com AVERAGE ROOF POINT DEAD LOAD=24.66 LBS END CLAMP 24 UNIVERSAL AF SERIES END CLAMP DARK TOTAL SYSTEM WEIGHT:1726.D4 LBS GROUNDING LUG 6 ILSCO LAY IN LUG(GBL4DBT) NaflonWldelp. FLASHING 70 FLASHKIT PRO,DIRK IOPK SOLAR♦ (N)3/4"OR GREATER EMT/PVC/LFMC RETAINING CUP 32 MLPE MOUNT AS CONDUIT RUN(7/8"ABOVE ROOF) ROOF DESCRIPTION ...NA'nONNADE SOLAR ROOF TYPE ASPHALT SHINGLE BA07 COUVNAVE.SUITES PHONE IBM) 9m PHONE(BOOT 008d992 *OF 00 TRUSSESTRUSSES Er I:o•I.oI.r�RnA.9.n"ieesnl.r.mm ROOF ODULE1 TILT AZIMUTH SIZE SPACING #1 32 16- 244' 2'X 4" 24"S.0 (N)(70)UNIRAC FLASHKIT PRO T Qp'\'P• n PHOTOVOLTAIC MODULES ATTACHMENTS SPACED AT 48"O.C. F\� �O `- VSUN SOLAR VSUN370-120BMH(370" \�f 4, �L I~ 69.37" VERSION DESCRIPTIONDATE REV / a INITIAL RELEASE OM4f024 UR / (N)STRING#3 0 PROJECT NAME / /0/ a 0 IS U) CD z LEGEND LU Z CD CD LO 5-U�O � JB JUNCTION BOX 0-Q Z N Z Z 3�Oo0 / UM UTILITY METER g Z(n N co Q ACD BOA FUSED AC DISCONNECT LU LU O 2 Z J I.-I.- d (E)2"X4"TRUSSES(71j 24"O.0 / / MSP MAIN SERVICE PANEL a 2 Q Q QSOLAREDGE HOME WAVE (n J INV SEt0000H-US STRING-INVERTER (N)UNIRAC SM STANDARD RAIL / ■ SOLAREDGE S440 POWER OPTIMIZERS / (N)STRING 92 CONDUIT SHEET NAME (N)STRING#1 / / UNIRAC SM STANDARD RAIL ROOF PLAN WITH /�I'�p'(" ROOF ATTACHMENT MODULES A. ALL ELECTRICAL EQUIPMENT, HALL NOT BE INSTALL,DISCONNECTS, / P" • FLASHKIT PRO(;B"O.0 SHEET SIZE MAIN SERVICE PANELS,ETC.SHALL NOT BE INSTALLED WITHIN 3'OF / EQ THE GAS ;'SUPPLY OR DEMAND PIPING. F\a NOTE:ACTUAL ROOF CONDITIONS AND VENT,ATTIC FAN ANSI B TRUSSES LOCATIONS MAY VARY.INSTALL O❑ (ROOF OBSTRUCTION y PER MANUFACTURER(S)INSTALLATION 11"X 17" GUIDELINES AND ENGINEERED SPANS FOR --- SHEET NUMBER ROOF PLAN WITH MODULES TRUSSES ATTACHMENTS STRING PV_2 SCALE: 3/32"=1'-0" NOTE:ACTUAL ROOF CONDITIONS AND TRUSSES(OR SEAM) CONTRACTOR INFORMATION LOCATIONS MAY VARY.INSTALL PER MANUFACTURER(S) NA��mOP SOOUR INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR VANCOWER,WA 90692 �+ ATTACHMENTS STR�C Ei CRTRRIICALL O NO - UW WI7 80898 PVMODULES D EFC ENSECAL PAOSASSCW-22 Eml:9.m,lmePt®mymoomMeeeoV r.com NaflonvAde�$+► SOLAR SEE ENLARGED VIEW Zp"0�0 rm 5�5 55 NATIONIMDE SOLAR ASPHALT SHINGLE ROOF ^XA T BAOT NE VANCOU R. M 98662 SUITE 9 1112 PHONE:(8M)—992 \4 Eml:9etsoler�&mynaConw.Eesalsi.mm ATTACHMENT DETAIL VERSION DESCRIPTION DATE REV SCALE: NTS INITIALRELEASE 094.,m2A UR PROJECT NAME END/MID CLAMP PV MODULES U)a H w 7z z w��0rn0 (� L-FOOT }p V Z N< U U Z23i0o0 v ASPHALT SHINGLE ROOF g m Z Q cc j Q LUwo2;� (N)UNIRAC ROOF DECK MEMBRANE }a SM STANDARD RAIL _ Q zi Q co :D 2.5"MIN. EMBEDMENT SHEET NAME ATTACHMENT (E)2"X4"TRUSSES @ 24" O.0 DETAIL FLASH KIT PRO FLASHING SHEET SIZE ANSI B BUILDING STRUCTURE 5/16"STAINLESS STEEL LAG BOLT 11"X 17" TTACHMENT DETAIL ENLARGED VIE WITH SS EPDM BONDED WASHER, 2 2-1/2"MIN.EMBEDMENT. sHEETNU3 SCALE: NTS PV- 32 VSUN SOLAR VSUN370-1208MH 370.0 MODULES SERVICE INFO BILL OF MATERIALS CONTRACTOR INFORMATION (32)SOLAREDGE S440 POWER OPTIMIZERS EQUIPMENT OTY DESCRIPTION runoNwloE sous (02)STRINGS OF 11 MODULES 8 UTILITY PROVIDER:MASON COUNTY PUD wr PoowEn wA 9esez (01)STRING OF 10 MODULES CONNECTED IN SERIES PER STRING MAIN SERVICE VOLTAGE:240V SOLAR PV MODULE 32 VSUN SOLAR VSUN370-120BMH(370.01A/)MODULES sTRULTURE/BLILOING:NATIOS'796 MAIN PANEL BRAND:SQUARED ELECTRICAL:NAT10s'788TW MAIN SERVICE PANEL:(E)200A INVERTER 01 SOLAREDGE HOME WAVE SE10000H-US STRING-INVERTER UBI:fi017 R: SYSTEM SIZE:32 x 370W=110.00 kVVDC EIFCTRK:ALSUPERJISO CIA78S BABBITT SYSTEM SIZE:1 x 10000W=10.000 kWAC MAIN CIRCUIT BREAKER RATING: - 200A JUNCTION BOX 01 600V 55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION EmAP p rm'Mhq m�jm6itlonxMA�wbr.com MAIN SERVICE LOCATION:NORTH-WEST SERVICE FEED SOURCE:UNDERGROUND OPTIMIZERS 32 SOLAREDGE S440 POWER OPTIMIZERS �t NOTE: Na 110n w f de d 3/4"OR GREATER EMT/PVCILFMC AC DISCONNECT 01 60A FUSED VISIBLE LOCKABLE LABELED AC DISCONNECT WITH 60A FUSES,240 VAC I�r1/) CONDUIT RUN(7/8"ABOVE ROOF) SOLAR♦ .....NATIONWIDE SOLAR 8607 NE 117TH AVE SUITE B VANCOUVER.WA 9802 PHONE:(800)908 2 11 MODULES IN STRING#1 E-L9—l.`o" ,ti°° ...I""', #11 ••• #2 #1 AC DISCONNECT SHALL BE LOCATED _ WITHIN 10 FEET OF I UTILITY METER L—————————————— VERSION 11 MODULES IN STRING#2 1 DESCRIPTION oATE REV(N) SO E HOME WAVE $ElDCOOHIDOOOH-US(240W) INITIAL RELEASE 8946d026 I1R OUTPUT:240 VAC,42.OA #11 • #2 #1 1 99%CEC WEIGHTED EFFICIENCY NEMA 3R,UL LISTED,INTERNAL GFDI 1 (N)JUNCTION WITH INTEGRATED DC DISCONNECT BOX LINE SIDE TAP I (N)BOA FUSED VISIBLE PROJECT NAME 1 _ LOCKABLE LABELED AAC- AC DISCONNECT WATH -— BOA FUSES,240 VAC (E)MAIN L--------------� 200A SERVICE PANEL, 10 MODULES IN STRING#3 60A FUSES 200A RATED, 1201240V #1C • #2 #1 I AC, I L2 �' 200A2P,240EAKER C D>_ FL--- -- -- -- - -- W Y Lo CO p rn 01 0()0)U N U NGBOND I (3)#6 AWGW THN I z >Q>Z O o Z U>U)O I _ (1)#10 AWG)THHWN CU#6 AWG ONO 3/4"EMTP)#A AIN CONDUIT I g z<NQ L— —___--------J (1)#B AWG THWN CU GND Q 3/4"EMT/PVGLFMC CONDUIT I LU W�2 Z (3)#10 AWG PV WIRE+RED EXISTING GROUNDING J�J}O_ (3)#10 AWG PVWIRE-BLACK (3)#10 AWG THWN-2+RED SYSTEM W I—Q Q (1)#10 BARE CU ONO (3)#10 AWG THWN-2-BLACK (1)!10 AWG THWN-2 GND SOLAREDGE POWER OPTIMIZER S440 3/4"EMT/PVC/LFMC CONDUIT RATED DC INPUT POWER-440 WATTS MAXIMUM INPUT VOLTAGE-60 VDC MPPT RANGE-8 TO 60 VDC MAXIMUM SHORT CIRCUIT CURRENT-14.50 ADC MAXIMUM OUTPUT CURRENT-15 ADC STRING SHEET NAME LIMITATIONS-8 TO 25 OPTIMIZERS, ELECTRICAL LINE 5700 WATTS STC PER STRING MAXIMUM DIAGRAM SOLAREDGE OPTIMIZERS HAVE INTEGRATED RAPID SHUT DOWN SHEET SIZE ANSI B 11"X 17" ELECTRICAL LINE DIAGRAM SHEETNUMBER SCALE: NTS PV-4 SOLAR MODULE SPECIFICATIONS DC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: CONTRACTOR INFORMATION ARRAY TO JUNCTION BOX: INVERTER TO INTERCONNECTION: NgT10N""DE SOAR MANUFACTURER/MODEL# VSUN SOLAR VSUN370.1206MH(370W) PO B mites VANCDWER,WA e5s82TWOS EXPECTED WIRE TEMP(In Celsius) 30° EXPECTED WIRE TEMP(In Celsius) 30° sTRucnIBEiBULd w,Tlos NO •7escw VMP(1/) 34.50 TEMP.CORRECTION PER TABLE 310.15(B)(2)(a) 1 00 ELECT US "n�os•7asTw TEMP.CORRECTION PER TABLE 310.15(B)(2)(e) 1.00 IMP(A) 10.72 ELECTRICAL SUPERVISOR:COLS BARRITT NO.OF CURRENT CARRYING CONDUCTORS 6 NO.OF CURRENT CARRYING CONDUCTORS 3 UCENSE:AOBABBICWle802 VOC m 41.40 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(e) D.80 CONDUIT FILL CORRECTION PER CEC 310.1 RB)(3)(a) 1.00 E-1.cermaa.or@mr�+nomwww.com ISC(A) 11.26 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR SIZE 6 AWG Nationwide MODULE DIMENSIONS 69.37°L x41.26"W x1.38°D CIRCUIT CONDUCTOR AMPACITY 40A CIRCUIT CONDUCTOR AMPACITY BSA SOLAR INVERTER SPECIFICATIONS REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B) REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(B) ,�„ •� MANUFACTURER I MODEL# SOLAR EDGE HOME WAVE SE10000H-US 1.25 X MAX.DC OUTPUT CURRENT 18.75A 125 X INVERTER OUTPUT CURRENT 52.SOA NATIONWIDE SOLAR DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(a) DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(BN2)(a) SQ7 NE I MH AVE.SUITE B NOMINAL OUTPUT VOLTAGE 240VAC VANCOUVER,WA RSS112 NOMINAL OUTPUT CURRENT 42A TEMP.CORRECTION PER TABLE 310.15(BX2)(a)X 32 o0A TEMP.CORRECTION PER TABLE 310.15(8)(2Xa)X 65 DOA PHONE:(SRN BB&8Ra2 CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)X CIRCUIT CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)X CIRCUIT Em 4:yeewl.rNm+A.uo.wm.:oMr.�om AMBIENT TEMPERATURE SPECIFICATIONS CONDUCTOR AMPACITY CONDUCTOR AMPACITY SANDERSON FIELD RESULT SHOULD BE GREATER THAN(18.75A)OTHERWISE LESS THE ENTRY FOR RESULT SHOULD BE GREATER THAN(52.50A)OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY CIRCUIT CONDUCTOR SIZE AND AMPACITY RECORD LOWTEMP -B° DC CONDUCTOR AMPACITY CALCULATIONS: AMBIENT TEMP(HIGH TEMP 2%) 3D° JUNCTION BOX TO INVERTER: CONDUIT HEIGHT 7/8• AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT CONDUCTOR TEMPERATURE RATE(ON ROOF) 90° PER CEC 310.15(B)(3)(c)(7/8.RULE) CONDUCTOR TEMPERATURE RATE(OFF ROOF) 75° EXPECTED WIRE TEMP(In Celsius) 30° VERSION MODULE TEMPERATURE COEFFICIENT OF Voc -0.-%1C TEMP.CORRECTION PER TABLE 310.15(B)(2)(a) 1.00 DESCRIPTION DA1E REv NO.OF CURRENT CARRYING CONDUCTORS 6 IN!nAL RELEASE a-1Asou uR NUMBERS OF CURRENT CONDUIT FILL CORRECTION PER CEC 310.15(8)(3)(a) 0.80 PERCENTAGE VALUES CARRYING CONDUCTORS CIRCUIT CONDUCTOR SIZE 10 AWG IN EMT CIRCUIT CONDUCTOR AMPACITY 40A 0.8 4-6 PROJECT NAME 0.7 6-9 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER CEC 690.8(A&B) 18.75A 0.5 10-20 1.25 X MAX.DC OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER CEC 310.15(B)(2)(8) ELECTRICAL NOTES TEMP.CORRECTION PER TABLE 310.15(BX2)(a)X 32.00A Q= CONDUIT FILL CORRECTION PER CEC 310.15(B)(3)(a)X CIRCUIT In(L 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED CONDUCTOR AMPACITY do}c FOR ITS APPLICATION. RESULT SHOULD BE GREATER THAN(18.75A)OTHERWISE LESS THE ENTRY FOR Q Z CD 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90 CIRCUIT CONDUCTOR SIZE AND AMPACITY (QjJ Z 00 O DEGREE&75 DEGREE C WET ENVIRONMENT. }'y 00 O v U 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL U 02 U N BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO 0 Q Z O Z THE NEAREST RIDGE,HIP,OR VALLEY. Z L) U)N VO) 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING 2 2 Q a Q ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. LIJ W O 2 •2 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. ti J d-'i CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, W P Q Q SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE _ CODES AND STANDARDS. f- 6.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE OPTIMIZER SPECIFICATIONS NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. POWER OPTIMIZER SOLAREDGE S440 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND DC INPUT POWER 440 W READILY VISIBLE. SHEET NAME B.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE ELECTRICAL FRAME AND MODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. CALCULATION 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. SHEET SIZE 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE ANSI B 11"X 17" ELECTRICAL CALCULATION SHEET NUMBER SCALE: NTS PV-5 CDNTRACTOR INFORMATION NATIONWIDE SOLAR WARNING: • • • PO BOX 61t959 PHOTOVOLTAIC VANCOUVER WA 9B6b] • STRUCTURE9UIlOING'.NATIOS'7BECW ELECTRIGL.NATIOS-7.TN . SOURCE LABEL LOCATION'. UB:6017806'95 PEIR CODE:NECCE I690.73(B))T/UTILITY METER SOLAR PV SYSTEM ELECTRIGLSE ADB SOR:COLEBABBITT LABEL LOCATION: ucENSE:AOSABBicwreaDz EMT/CONDUIT RACEWAYS - .: 27 Erma:p�mAd�pr®mymM1onwlaeaohr.com EMTICOD TRACEWAYS2) EQUIPPED WITH 480 MAXIMUM NattonvWdeS► • • • PHOTOVOLTAIC . • N SOLAR 45 CURRENT(Isc) EQUIPPED WITH MAN 111] • I:x ..- • LABEL LOCATION: F 7HE I17 IDE H AR LABEL LOCATION. RAPID ® W07 HE iU AVE.AWE SURE B AC DISCONNECT DC DISCONNECT,INVERTER vnxcouvER.WA eaBBz NEC 690.13(B) LIBEL LOCATION: (PER CODE:NEC 690.53) Erma:gPHONE'(—)tlomltlAaoYr.mm UTILITY SERVICE ENTRANCE/METER(WITHIN Y), INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. TURN RAPID SHUTDOWN SWITCH TO PER CODE(S):NEC 2D23:690.12(DN2) THE"OFF'POSDTON TO SHUT DOWN DUAL POWER SUPPLY PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOURCES UTILITY GRID _ AND PV SOLAR LABEL LOCATION: ELECTRIC SYSTEM SOLAR ELECTRIC BREAKER IS BACKFED MAIN SERVICE PANEL PER CODE(S):NEC 2D23:690.56 S IFC 2D21:1205.•.1(1) VERSION LABEL LOCATION: POINT OF INTERCONNECTION DESCRIPTION DATE REV PRODUCTION METER LABEL LOCATION: 4" INITIAL RELEASE DIPI G UR NEC 705.30(C)S NEC 690.59 MSP(PER CODE:NEC 705.30(D)S ELECTRICAL SHOCK HAZARD NEC S90.59 TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN • • THE OPEN POSITION PROJECT NAME THE DISCONNECTION OF THE THIS EQUIPMENT FED BY DISCONNECT GROUNDED CONDUCTOR(S) LABEL LOCATION: MULTIPLE SOURCES TOTAL INVERTER (V MAY RESULT IN OVERVOLTAGE (S),AC DISCONNECT(6),AC RATING OF ALL OVERCURRENT COMBINER PANEL(IF APPLICABLE). ON THE EQUIPMENT • DEVICES,EXCLUDING MAIN PER CODE(S):NEC 2023: Q NEC 705.20(7)S NEC 690.13(B) SUPPLY OVERCURRENT � R PARALLEL LABEL LOCATION: INVERTER DEVICE SHALL NOT EXCEED Q O_u) PER CODE:NEC 690.31(E) AMPACITY OF BUSBAR GENERATI• 0��O r ELECTRICAL SHOCK HAZARD O Z LABEL LOCATION: Z 00 O POINTS OF CONNECTIONIBREAKER LOCATION:NEXT TO AC DISCONNECT W z �Lo CQ O CODE:NEC 705.12(BM2) TERMINALS ON LINE AND LOAD 0 L)m L)N U 5" POWER SOURCE SIDES MAY BE ENERGIZED IN 4. 0—Q Z O Z DO NOT RE OUTPUT �OCATE THIS NNECTION THE OPEN POSITION SOLAR Z METERU N U) OVERCURRENT DEVICE LABEL LOCATION: r2 Z Q N Q PHOTOVOLTAIC INVERTER(S),AC DISCONNECT(S),AC W LU O 2 Z 2 COMBINER PANEL(IF APPLICABLE). PARALLEL I.-F d LABEL LOCATION: • • PER CODE(S):NEC 2023: O W}Q= SERVICE PANEL IF SUM OF OPERATING iAMP NEC 705-0(7)a NEC 690.13(B) _ a Q BREAKERS EXCEEDS PANEL RATING _ ih =J_ NEC706.12(Bx3H2) • • 1 • GENERATION • co p LABEL LOCATION' AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINTOFINTERCONNECTION. PER CODE(S):NEC 2023:690.51 ELECTRIC SHOCK -i SHEET NAME IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED LOCATION:NEXT TO METER C NDUCTORS MAY BE WARNING LABELS UNGROUNDED AND ENERGIZED SHEET SIZE LABEL AD AND SUB PIANEL ANSI B 11"X 17" SHEET NUMBER PV-6 CONTRACTOR INFORMATION NATIONWIDE SOUR PO BOX-X. VANCOLVER,WA 9 2 STRUCTUREIBUtLY HATIOS.TS6CW ELECTRICAL:NATIOS'TBBNJ UM 8 7B06B5 ELECTRICAL SUPERVISOR:COLE BABBITT UCENSE:ADBABBICWi 2 Em n:permiWepit�mynahonwMeaoler.wm Nationwidep► SOLAR♦ (E)20DA MAIN SERVICE PANEL NTH (E UTILITY METER ♦ ,,—, NATIONVADE SOLAR^ . BA07 NE 117TH AVE.SUITE B VANCOUVER,WA BBBB] (N)INVERTER PHONE:(B )BO N2 Email:pAhWArQmynAtionviEAsobr.wm ♦• • VERSION DESCRIPTION DATE REV INITIALRELEASE 041440E UR . PROJECT NAME Q0- �0_ pOrolr- wvZoZ WzioO0O �2oo0m DIRECTORY 0 U U cV Z PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE Z 2�ZO c O SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. g L Z Q N Q (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC Lu LU O 2 Z nt; ..d 690.56(B)&(C),[NEC 705.101) m r Q= =J Q THE REQUIREMENTS FOR THE PLACARD ARE: U j MADE OF METAL OR HARD PLASTIC HAVE A RED BACKGROUND WITH WHITE ENGRAVING LETTERS SHOULD BE 9MM(1/4")TALL(COMPARABLE TO 25 POINT ARIAL FONT) SHEETNAME PLACARD SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-7 CONTRACTOR INFORMATION -� NATN)WXa SOLAR .I• PO BO2t956 VANCOWER.WA9 2 • III I II STRI ELECT ONLgNTINAT105•)B6CW r ELECTRIGL'.NATOS')BfiIW "��. ' ELECTRIGL SUPERVISOR.COLS BASBRT JCENSE:A09AE81CW)8802 ,I E-1_adept®myraMnxiEes W.. I ) ♦� �` Nationwide.,,. SOLARM "tJ .....NATIONWIDESOLAR� eM7 HE I l"N AVE.SURE R VANCOUVER.WA 66662 PHONE:IBM)BOB88B2 �,• Em l:6ANAI•lQmyN6A ...W- LLLL .r` 6R1DSTREAR RF F06F6667 \ VERSION DESII REUT S GATE EUR INITIAL RELEASE 06-14]MA i I PROJECT NAME t Type FOCUS AXR-SD y p _. FORM 25 CL200 240V 3W 60Hz TA=30 Nh 7.7 (!`. - a N d MASON COUNTY PUU No.3 e 20-03061 1 285-068-00005 O 147967707 ° - •1 �Za�Djo� �,�, III a IIII IV':'tl II It II u W_an }Q��pNOU zoz .f zU�Oo0 gLU011)N Q Q wwOgZg 7 J o J d } a=F-a¢ O • �--- o-(',}/' SHEET NAME ELECTRICAL PHOTO T. SHEET SIZE ANSI B 11"X 17" ELECTRICAL PHOTO SHEET NUMBER SCALE: NTS PV-7.1 CO CTOII INPORIIIAMN 1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER NATIOM&VESO AR MANUFACTURER'S REQUIREMENTS.ALL SOLAR MODULES, EQUIPMENT,AND VANCOER,WA WWER,M IWI STRUCTURFlSL7LdNG:NATIOS']BSCW METALLIC COMPONENTS ARE TO BE BONDED.IF THE EXISTING GROUNDING EEC RGL NA pb']S6TN ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, EIECTRIGL SUPERVISOR:COLE 61ERITf LICENSE:ADSABBICW/eeOl IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL E"l°"""°°°°""""°"°'"""°" GROUNDING ELECTRODE. NattonWde� SOUR 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL v ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC,ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL NATIONNADE SOLAR BE UV RESISTANT IF EXPOSED TO SUNLIGHT. BMTNE„TTH AVE.SUITE9 VANCDUVER,WA SUIT PHONE:(epp)pp 9. Ema9:peHolar®myneEonxiEnebr.mm 3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED,"CAUTION DC CIRCUIT"OR EQUIV. EVERY 5 FT. 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.138(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO VERSION CONNECTING INVERTER.VERIFY SERVICE VOLTAGE IS WITHIN INVERTER DESCRIPTION DA E REV VOLTAGE OPERATIONAL RANGE. INITIAL RELEASE 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 0 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL ai r MEANS DESIGNED AND LISTED FOR SUCH USE,AND FOR ROOF-MOUNTED °Z ~ SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE of Z CO Z)o Z) ROOF SURFACE.NEC 110.2-110.4/300.4 }Y co u v-o ❑L)M cv p-Q Z o Z z��ONO z¢c.Ia Luwo2Z� J I,—J as v Ll j < =J �F SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-8 CONTRACTOR INFORMATION NATIONWIDE SOLAR PO BOX 821959 VANCOWER.WA 98692 STRUCTURESUILOINO'.HAMS— ELECTRICAL:HATOS'7B6TN UBI:60a780695 V��� EIECT LICE SUPERVISOR.COLS BABBITT LICENSE:EWSOR COL 01 Emell:prmedept®mlmaWnwNesokr.com Electrical Characteristics at Standard Test • Innovative N Smart Maduls Type VSBN310-noe- VSUN]65.I20aMH 1SUN3S01N3BMN VSUN355-12.14. ��•tEj� Manimum Power PmaA(W) 310 365 Ifi0 355 NaflonvAde4► ocenomaavwrage.vxM 414 41.1 4ce 4c4 SOUR♦ Sh--.11:Current-I1(A) tl.l6 uJ9 ll.l2 11.05 v sumum Poser Voltage Vr,PP N) MS 34.3 N 337 Maslmum Power Current Impp lAl 10.12 10.66 10.59 11,11 •-•���^^��^'-w•—"^ Module ERkiency xo.04% 19.1i% 1X,S 19.2M6 NATIONWIDESOLAR Standard Test Conddilll(SrC):imadiam. 2m; l,;nwdulelemperaun25C.pmanSordng.0-SW.Mea..Ing tolerance:i 3%. 647 N E117THAVE.SUITEB 25 �O nt iH types. VANCOUVER WA 99681 Remain:Etettncal data do nor toter m a single module aM Mey are not part of tM1e offer. ey only sme lercompanson among diNere module pes. PHONE:(900)WA 9802 Emai:eetsolnr�mrynnaonwidasobr.com YEAR YEAR Pm..lw) VeeCV) W(Al Vmpp Dr) ImpP(Al Impp(A) Iss 41.40 11,82 M.W 10.38 5% 407 41.40 12.31 3'1'" 10.3E lU% 4a3 4150 13.51 U40 11.S7 20% VSUN370-120BMH <61 4150 14 B 144 12.36 2M VSUN370-120BMH VSUN365-120BMH Material Characteristics VSUN360-12OBMH VSUN355-120BMH oimP 1... 176211048x351mlLXWIHi NOCT 45'C(t1'C VERSION weignt 19.6kg Voltage Temperature Coelficlenl 4.2W/-C DESCRIPTION DATE REV frame Silver arwdiaM aluminum profile C.,rem Temperature C«Nicienl w.0544%PC INITAL RELEASE aM4Z024 UR Front bless wNXe toughen,safety glass,32 mm Power Tampere—C-M,Wnl ().32%rC C,11370W 20.04% PPlat� Tninsp(ElM1yleoe Vh AMetwe,o 1D6 Back Glass Transparent mesM1 eacksheet •, Cells 11x 10 pteces 611aclal mpnperystalline sPlnr Highest power output Module efficiency cells woes mrt, Maximum SO—Mug.M 1000/t500 lunnion sot IP6e,3d.—I serKs rosr Radng(AI 20 PROJECT NAME <a61MCpnneetpr Cobb knglM1=llOUmm BilacialHY 7—W Connet—W.lA4mm ABOUTVSUN Invested oy Fuji Sclar,VSUN SOLARisa solar Solution p—der with Olmeml—ILx WxH) 1820.n25x118lm1 Temperature lung, X,'Cto•85'c Q headquartered in To,%io,Japan that offers reliability,high efficiency Container20' lg6 Wit6slaMMg Xall Maaimumdlarneterol25mm <0— solarproduasandtechnologVglobally.VSUNis rated asBNEFTerI conuinerw' w3 w,mimpxTaPeedprz3ml. Q��,o PVtnonulemanuf.3cturer.PVEL Lib'Best pertOrnsel'and ECOVadls Manimumsurf_1l d 5,w0 Pa KEYFEATURES 'S,o Award'. Cn i„e.w'HC ens A tbnda:: d—A V Z rn Z ppira LU Z 00Lr) � Iwo: PERC Cell Technology DimensionsIV-Curves r0(Yj OD O N O Higher output power PRODUCT CERTIFICATION got„� A_.A Q Z O O Z Fr.— ZU�ON }y Lower risk of micro-ack ,w C g ® _ g 2 Z Q N Q ® ` 3 a _�_- wlu02Z� 4 Positive tolm we Offer J J d .n+v O }Q= ! Lower risk of hot spot L B-ibwt lie Ible • I+eear•+1(t =J Q LU PRODUCT CERTIFICATION a 4 Plxa to— Better shading tolerance $ s Munich RE 1W w..N QCertiBad for aelvammonia mrrosicn gay reeietance 11gWt l Load cWfimtea:wind to 240OPs and 0 4m. C-Yann Ible snow to%OOPa 4 pi p1w �•� ,.� SHEET NAME s lower LCOE 3 SPEC SHEETS N,,6 t05e+r: 11— 2ow.n 25 yeas 30 yrors • • " iota I s1a31 s••r+v• •AIM enwi ae warrey PM0 tier 11"M tips t.w.r'••s'-`•r•-e•a'•w" SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-9 CONTRACTOR INFORMATION NATIONWIDE SOUR PD Sc.821959 VANCOWER,WA 86662 STRUCTURE/BUILDNO:NATIOS']66CW ELECTRICAL'.NATIOS'7B6iW U&:60a]80695 / SoIarEdge Home Wave Inverter ELECTRICALS Email uw mnEe q ADOJC OLc OiABBI rT � DmBVBAA�B�C�6.8b .Pnm SolarEd a Home Wave Inverter g z For North America Nationwide.:• For North America E�0000H us sE„aooH us SOLAR* ii SE3000H-US/SE380OH-US/SE5000H-US/SE570OH-US/ m SE6000H US/SE7600H US/SE10000H US SE11400H US ourrur N7 NE 117THAVELAR - WO]NE 1 WIDE SO RE B 1M00 6 24W VANCOUVER.WA 988S2 ;.. .'.r"W 10LC� 10DJ]0 200V ___ VA PHONE:(WO)BOBd9B2 M em,m AC Per OLIpx Iowa I= 241N VA E-1:Babdaremyna6onMNawh— _ IDD00®208V MAC Ou pn Vd09rNk-Na -Mu. J J Vac Al111 Wtgrt Vdbpe M".-Nan-M+c - J V. a3-206-? 0 O KP R19Rna0 59.3-60-60Y A M'wrum Cabawt OMixA Carts•24W 42 4.5 A Marmarn EONlnuaa OuWtn Curlart Oa78V 4.5 A Pwrt P.avn P LAg.Stabh-Offiw085 GPD Tresbp 1 P O O UiNry MaYraing,Isbntllrg raectgn _.. Ves Cant C abk Thresholds VERSION INPUT DESCRIPTION DATE REV layrrxrm DC Pacer 024ov 1N00 176SO W .o) L4vnam DC P—02M IS500 W INmAL RELEASE 6F14,A34 UR O aulnr,y.,^•^ .J® O O •" •.••.• —to) m Trar'¢'ama.krt an0.W YOE • J " lAixmu I V 48D WC, • min O wm,N DC Inpn VdpLp - 3p Vdr Mw lnwr Cur-0240YO Z7 305 Ad, O I O MaarumInp.t ct—@20W i 27 Adr PROJECT NAME Mar.npU Shot Ceivir Carets 45 A& R everse-Puld anN Dra�__ ft a p O a G.W Wit lsdaS n DekRon SON tk _ lAuir�-n Inverrei EMc' 992 % - - _ CECWe hWErrsenly 99 �®2 % ry Dort evrwa ra�uaryHnn .7z w 'a ADDITIONAL FEATURES 0 m it Optimized installation with HD-Wave technology wPPaNd`mvnnkallPn XYrlares RSa95.Fdwrret.Wrekss Hare NeNArt +.wl-fl CNL3ar'"PO0na6 X a Z O Z p 9Y Nevin G — ANLC)a Uj Z Go D LanV nnMWwi W—LC3 O rn O Specifically designed to work with power / UL1741 SA certified,for CPUC Rule 21 grid P^e^Hcom.^m l `""^"`r. 1no0ikaPPi`.iOOniSYi9&i° A"'P1i1rP"°°"" onnP1iO^ Q(Yj Qw2 U N V Rap. HEc 20M-2023 Par+tkhs optimizers compliance 6%,11 and 690.12 A'A°^'ak Rapti SAAOoxn upon AC GW Ds<mnen 0 C Q Z 1 Z ___....._ ..__._ Z O C�� Record-breaking 99%weighted efficiency / Small,lightweight and easy to install both STANDARD COMPLIANCE cavaPHroun4Lu174nAunasbut699a g ZQNQ sdmoutdoors Of indoors Cerww CSA 77N137.1 QI aF3 C22.3P9.AH 9540 W W O M Z Quick and easy inverter commissioning directly GW Cm"Mw'SVib tls 1EE154a W SEE'l5421. 14H - --- - EmsNm. J KC Part 15 Chss B n J d from a smartphone using SoIarEdge SetApp / Built-in module-level monitoring 02 Q= INSTALLATION SPECIFICATIONS <'W_ Q KDx nCcM sze/AWC 1"MpnaAn/M-4AWG =J Fixed voltage inverter for longer strings / Optional:Faster installations with built-in DC"M Ca."sze]ad /Awc rAEaiwan2l-3 /16-6AWG U) consumption metering(1%accuracy)and Dmem'raS swm Sabry srAa 111,10) 2106.N6a73/515.37D r.185 ZI06e146 e81/535a370a20F°I h/RPA D Integrated arc fault protection and rapid production revenue grade metering(0.5% vk yn„1r sa'rn swnm 36a/17.6 43.9/20.M+ bfhg shutdown for NEC 2014-2023 per articles accuracy,ANSI C12.20) tide "0 r& 690.11 and 690.12 - .._._._-----.— NWnelcaNamPn rena,an:re -40 w•M0/40.-6000 'E/-C SHEET NAME PrctMva�Re4a3 KMk 4x ft..W h SAly S.1kN SPEC SHEETS iANpn lv ma.b.�z ee n..v.xe rnenrM na�n�mme rJ:�Nrq. nr'- mrr rlamno.nM tome SLrEq�e More aexlaw RAcrono-,mN..T Re.F.»oaf r,ow�na.,n,eco„wmr+ •*..r^irr.sw..Musmmru.Ear.eba....na•••m..eEo,.>rovaawernr:<w+er srAeroxo-zmHA.zo n Am zo�nar x a».. SHEET SIZE �1 om-�s..,e..snme�m+tan�+.iroyn>uHxw s.ra.,..e.rnr<,..,n4.Aa.Pe.�e<.-,nr.r<.,.wro.wn mode.6cLu�Ne ue.,,om ma�nwwa,IH.w.DI:;�" ANSI B so I a r3E,�'[' solaredge.com S .: �e..^�me „_ m n ��a�•n+x,H._m� n .a �, eE 11"X 17rr .•„e..,...ae.. .�,.,o.._._,�u.vm„w,a... v _. SHEET NUMBER PV_10 CONTRACTOR INFORMATION RATIO DE SOUR m BOX 921969 VANCOWER.WA9M02 STRU TuREARAL01NG:NATIOS•766CW ELECTRIGL'.NATIOS'786.1W ELECT UCE SUPERVISOR.COLS fiA9aRT / Residential Power Optimizer EmedCENSE ADSABBICW BeO2 '.prmedapt®mynelpnw.aol.r.can Residential Power Optimizer O For North America NaflonvAde�,• For North America S sago S500B/S650B SOLARO G INPUT ..®`. 5440 S500B/S650B ---- - �__• "" `—' Rated li9*ul DC VUWr'^ 4tl'� ,m 650 W NATiONNADE SOLAR T A6 dC MM mxn"ypw 60 _ _ 85 bd07 HE 117TH AVE.SUITE 8 AiPf 8-G 1'.S-l:s 12.5-85 Ya[ VANCOUVER.WA 99662 _...-.Qm _ PHONE:(800)9058992 r7 Magnum hpM CtneM PAaxWun H;dConccm IN fApQlel N5 A rm0 Ad, E :9ebolxr�myna6onvMesoler.wm SWmum`,P,SlutC't c-, 15.7S AV Mnimum E 99.5 95 yAaiJRNA FAICNncy _ 99.6 99 rNenre C:teunry H 0 OUTPUT DU RI NG OPERATION'POWER OPT IM 12 ER CONN EC7 E D TO OPERATING SOLAREDGE INVERTER) 1F ACt CC VJt OUTPUT DURING STANDBY(POWER OPT IMI7_ER DISCONNECTED FROM SOLAREDGE INVERTER OR INVERTER OFF)_ M uvc.UVenneci 1 t 81 Vh — Sn! UaIPut VJWAIvrP _ STANDARD COMPUANCIE _ VERSION phxtm:llar Rdpld ShlShwt Syx stem N=C 201a-2023 DESCRIPTION GTE REV EMC KC Pan t5 c'W 8 KC 61900fi-2.KC 6100D6-3 ._ - INITIAL RELEASE P9-to-2M1 UR SAkty KC 62MI(claa fl ,UL 1741 _-- Ma1Mdl LA 94 V D W Rat4erA N ROHS Ve VOE-AR-E 7100.7127013-OS TINSTALLATION SPECIFICATIONS PROJECT NAME Dxnemive(WvlxM 1Ax155x 30/ 1111 99,IS5 x 45/S.B7 x a49 x 1.77 mm/In S 07 v6.10 W�rl 720i l.6 79(1/171 /E Iry.rt Ga MCI Q Input Wtre lnnIi: __ - (11/032 m/R Q Q QnPw V. .' (•12.3.1�1010/(•)751,(-)032 MIR Q �O F PV power optimization at the module level LL yT r,�,,.FI ,ot 85 c v Z o z PP twt Rat g KU NE— Q Z Z O Wa. H,aNy _. 0 IN 96 In O)O / Specifically designed to work with SolarEdge / Faster installations with simplified cable P� � - - _ }Y� residential inverters management and easy assembly using a single wT O U V U N bolt vrc' l...m.,.�hd�:�:asc�.wir.- .. .., I_._3 _.....� Q >Q Z 0 Z / Detects abnormal PV connector behavior, �+ Z U> N O preventing potential safety issues / Flexible system design for maximum space W W Z Q CV< utilization r< id rV Grid J Z N6rt num Svlrv)1e1V9A(Faw•r 561C t`_j -/ Module-level voltage shutdown for installer op' - - - -- - r i - J}< ��:e.•1 ssme.s6s�9 �, 1. and firefighter safety / Compatible with bifacial PV modules NW.num st_n9 Le gth(P—P Opt-ft,s) 25 x'� 2 J Q rMv vui UvCIe I"—Dtli avttt St' 57M am 12750 w U) / Superior efficiency(99.5%) / Meets NEC requirements for arc fault wenR— Per ae reRnC:Psam.m rnM protection(AFCl)and Photovoltaic Rapid AL p :570M a A,WP W / Mitigates all types of module mismatch loss, Shutdown System(PVRSS) Nti.11-Alkn Cmrur!C.f .pn +wet Ra 5700 Ore.19 R00 15,000 Poxes.P^5vin.T o AC P a Ftpnyr Tw snxts a IWxe 79DO from manufacturing tolerance to partial nRalee 9w,pny.e,i:rpPe.s�Ne shading t_ 'ri ALP 7tiuuW _at Na .__gin _ y�...._— __. .__ _...._..._....._._. SHEET NAME �rl eSnn �I ple entl Q,n axris t Pw.e,+]gmsv n,rta rn xl+psn q SPEC SHEETS 'roBV3'd nti mununn Mm'e!u-hMm*e dYww��<a.w-M N.Nw.w M'7M M60W SYu GIn n 1m v a 7»/ayI V 9^a*Re maxaMae m1nead wey efnn Ve Mnerce n mxR[M 7.aW bwnraga2900WW NM SHEET SIZE ANSI B solaredge.com solar= • • "- ^:�".r .,.- ° 'p�:~ .,�""m°"�"�"r ..""°""'`x" °'�". Q RoH3 1111 X 17" . ..m.,x x.m a...„aR p mW aW ......e.....e. SHEET NUMBER PV-11 CONTRACTOR INFORMATION NATIONWIDE SOLAR PO WO 821958 W VANCCER.WA 98S82 STRUCTUREAtUILOINO:NATIOS-)S6CW ELECTRICAL:NATIoS'TSSTW Uo 604TSOS85 ELECTRICAL SLIFEWSOR:COLE EASSITT UCENSE:ADRASRICW)8802 PRO SERIES END CLAMP PRO SERIES MID CLAMP /,"BOLT LOCATION Em"a:�rmm.q@mv".m"ae"."ur.""m Nationwide.: SOLARI 1�6" U%S" 11�" `NATIONNADESOLAR~ SMT HE I ITTH AVE.SUITE R VANCOUVER.WA SBSS2 1" PHONE:(SW)9-992 Emsl:pahol"r�mynetlanwitlezoler.cam 30mm to 51mm MODULE FRAME PART#TABLE 2 S" U PIN DESCRIPTION J� 302035M ENDCLAMP PRO 302030M MIDCLAMP PRO-MILL VERSION 302030D MIDCLAMP PRO-DRK DESCRIPTION DATE REV INITIAL RELEASE OF1420t! UR BOLT LOCATION PROJECT NAME PART#TABLE MID CLAMP P/N DESCRIPTION LENGTH d 320132M SM RAIL 132"MILL 132" p p H 310132C SM RAIL 132"CLR 132" Z O Z 320166M SM RAIL 168"MILL 168" LLJ tn 00_ 0 Y Y D a END CLAMP 310168C SM RAIL 168"CLR 168" U m(>N ❑2>QZ—Z 320166D SM RAIL 166"DRK 168" Z 0> N U) Z 320208M SM RAIL 208"MILL 208" m Q N Q 310208C SM RAIL 208"CUR 208" J LL!0 Z 2 �t ..D.7 END CAP 320240M SM RAIL 240"MILL 240" LU�_Q Q INCLUDED WITH END CLAMP 310240C SM RAIL 240"CLR 240" =J 310240D SM RAIL 240'DRK 240" u•U N I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE o ■■ PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ��� ALL DIMENSIONS ARE ~ ii U N I RAC ALL DIMENSIONS ARE 1-1 C SHEET NAME DRAWING TYPE: PART&ASSEMBLY NOMINAL Q DRAWING TYPE: PART DETAIL NOMINAL o 1411 BROADWAY BLVD.NE 1411 BROADWAY BLVO,NE SPEC SHEETS ALBUQUERQUE,NM 87102 USA PRO SERIFS PRODUCT PROTECTED BY DESCRIPTION: nLBpuERquE,NH Bno2 USA DESCRIPTION: STANDARD RAIL PRODUCT PROTECTED BY X BONDING CLAMPS PHONE:505.242.6411 ONE OR MORE US PATENTS SHEET SIZE PHONE:505.242.6411 ONE OR MORE US PATENTS WWW.UNTRAC.CON REVISION DATE: 9/11/2017 WWW,UNIRAC.COM REVISION DATE: 10/26/2017 LEGAL NOTICE SHEET LEGAL NOTICE SHEET ANSI B 11"X 17" SHEET NUMBER PV-12 CONTRACTOR INFORMATION NAT101—E SOLAR PO[IO%521959 VANCOWER,WA TICS SIRUEXTRICA:N TI NAT7057OSCW ELECTRICAL:NATOS•]OSTW ELECTRICAL SUPERVISOR:COLS 9ARSITT LICEMSE FLASHKIT PRO :6m'UNI RAC� FLASHKIT PRO :s:UNI RAC� E*1 �r�A ruluelxa O SHED 6 SEAL Tic.-... INSTALLATION GUIDE 1rA/UnII15 O SHED S SEAL TECMIIOWAY SOL.AR)P,- FLASHKIT PRO is the complete attachment solution for composition shingle roofs.Featuring Unirac's patented FLASHKIT PRO IS THE COMPLETE FLASHING AND ATTACHMENT SOLUTION FOR COMPOSITION ROOFS. SHED &SEAL technology,a weather proof system which provides the ultimate protection against roof leaks. "A110"""DE SOLAR W7 NE 117TH AVE.SUITE S VANCOUVER,WA—12 Kitted in 10 packs for maximum convenience,flashings and hardware are available in Mill or Dark finishes. PHONE I'm)Oa&8892 E-1:41 pelaolar®mynatlonxitleaala r.wm With FLASHKIT pro,you have everything you need for a quick,professional installation. INSTALL FLASHKIT PRO FLASHING INSTALL LFOOT ATTACH L-FOOTTO RAIL Ir PRE-INSTALL Drive the lag boll down until the L toot is held firmly in place It is VERSION numlal for the EPDM an the underside of the stainless steel backed DESCRIPTION DATE REV Locate roof rafters and snap chalk lines to mark the installation EPDM washer to compress and expand beyond the outside edge of INITIAL REL -EASE W M4 UR point for each roof attachment. the steel washer when the proper torque is applied. Drill a 7132"pilot hole at each root attachment.Fill each pilot hole. TIP. with sealant. •Use caption toavond Over lorgueWhe lagboll if usingan impact driver. PROJECT NAME STEP 1 INSTALL FLASHKIT PRO FLASHING •Repeat Steps I and 2 at each roof attachment point. Add aU-shaped bead of roof sealant to the underside of the flashing STEP3 ATTACHLFOOTTORAIL with the open side of the U pointing down the roof slope.Slide the aluminum Bashing underneath the row of shingles directly up Insert the included 3/8"-16 Lbolls into the lower slot on the Rail < slope from the pilot hole asshown Align the indicator marks on the (sold separately).spacing the bolts to match the spacing between o F— lower end of the flashing with the chalk lines on the roof to center the roof attachments. v Z o Z the raised hale in the Bashing over the pilot hole in the roof.When LU Z 00�CD� installed correctly.the flashing will extend under the two courses of •Position the Rail against the L Foot and insert the threaded end of y Y CC O Ov shingles above the pilot hole. the'r Boll through the continuous slot in the LFoof.Apply anti seve L)M U w Z to bolt threads to prevent galling of the T.bolt and included 3r8" U ZO o p serrated flange nut.Race the 3/8'flame nut on the T bolt and rn a STEP 2INSTALL L--FOOT finger tighten.Repeat SFEP 3 until all LFeet are secured to the Rail g ¢w¢ Z with aT-boll.Adjust the level and height of the Rail and torque each w O Z Fasten L-toot and flashing into place by passing the included lag boll to 30fLlbs. rn-r Q= 40 bolt and pre.installed stainless steel backed EPDM washer through a=t_ ¢ TRUSTED WATER SEAL FLASHINGS YOUR COMPLETE SOLUTION CONVENIENT 10 PACKS the L-foot EPDM grommet.and the raised hole in the Bashing,into the pilot hole in the roof roller. ~ 1-111na A SHED s SEAL ucntlomar flashings,lags..coin inuousslot LFeet and hardware Packaged for speed and ease of handling SHEETNAME THE COMPLETE P ROOF ' ' ATTACHMENT E SOLUTION FASTER INSTALLATION. A ' A R WARRANTY RRA SPEC SHEETS SHEET SIZE FOR QUESTIONS OR CUSTOMER S[RVICE VISIT UNIRAC.COMOR F5) 248-2702 FORQUESTIONS OR CUSTOMERF F F5) 248 2702 ANSI B 11"X 17" SHEET NUMBER PV-13 COMPACTOR INFORMATION NATIONOmE SOLAR PO BOx 62— NOTES: VANCAWER.WA-2 STRUCTUREIBUI ]LOINO:NATIOS' W 1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN SPECIFICATIONS ELECTRICAL.NAnosTfieaW AND INSTALLATION INSTRUCTIONS. ELECTPoGL SUPERVISOR.COLE BABBITT 2.PACKAGING:KITS OF 10 4CENSE:ADBABelec68O3 Emea'.CENSepADBA I e aler.rgm Nationwide SOLAR NATIONNADESOLAR —NE1 HAVE.SUITEB - VANCOUVER.WA M62 PHONE:(SCC)9O 992 E-11:pehohr®rryvtlonvAtlesaYr.00m 12" 17/8" VERSION DESCRIPTION DATE REV INITIALRELEASE WA4 UR 2P 8 1/6rr SS SERRATED T-BOLT PROJECT NAME SS SERRATED FLANGE NUT 3/8" L-FOOT WITH GROMMET Q 5/16"x 4"SS LAG BOLT Q d t W/SS EPDM BONDED WASHER o 27/e" ''ZoZ - LU In0 O rn0 co p L) 0 c%l Z O o 0 V� 8"FLASHING g Z Q N Q WLu02Z2 D_� PART X TABLE 2 J Q Q P/N DESCRIPTION In F- 004055M FLASHKIT PRO MILL 004055D FLASHKIT PRO DRK __. ....... SHEETNAME U N I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE C @:on ALL DIMENSIONS ARE SPEC SHEETS DRAWING TYPE: KIT DETAIL NOMINAL SHEET SIZE BROADWAY BLVD,NE ALBUQUERQUE,NM 87102 USA DESCRIPTION: FLASHKIT PRO PRODUCT PROTECTED 8Y H ANSI B PHONE:505.242,6411 - - ONE OR MORE US PATENTS 11"X 17" WWW.UNIRAC.COM REVISION DATE: 4/28/2020 LEGAL NOTICE SHEET SHEET NUMBER PV-14 CONT UACTOR INFORMATION NATIONWIDE SOLAR .;; SM SOLAR CODE COMPLIANCE NOTES;':�� ENO SOLAR STANDARD SYSTEM GROUNDING ■ 6.EE FJBOUIR•■ W:NA 'B ; MOUNT „l I ;PACE •• ;��MOUNT INSTALLATION GUIDE:PACE L UBL6w1Bp C ELECTRIG SUPERVISOR:COLS BABBITT LICENSE:ApflABBICWIeBOi UL9105 CERTIFICATION MARKING IABQ 3 WEEBWG y tERNN NR. E-1:prmiOdApIIBPrgmatlanwitlpoYr.wm Un ra SOLARMOUNT-tsted to UL 1703 CertiM1cation markl ,embossed 11 E imps a,,hasvn.Labels with UNMAC .- n9 SlnBle Ux Only �g aUOit I'InFullallon,lilt he pipvidM.After"ra<klrsg system Is Nlly asu hl d I gle label should M app, �1! —_�l J— tne 50URMOUNT 1 at the cage of the array Before t,-i9 .I ed 1 the f M IaDM toot do riot perti n m �. _ /�� NafAon" hsys M rp I Lled must he remp-1 so mat., the.but R d system ype h n9. `` - �I as [e^FAR Note.the st[ker laep shoved be phced sum mat d-s v sak.but na outward facing. C US / ONE.,[RI ROW OF MDWLES: \� SOLAR S 0 u I e Per row f d 1 lEGgo9 =_, rerW ea See wge e day I -- ��— IuBt equ4ed for covens on IMnrc 7 WEEBLUG CONDUCTOR UTW►M 00BW7S NATjjI iiRSOLAR .;,!_.•-'" BaSt NE 117TH,WA SUITE B _-. ! ApplyA USeIxaM In ert abolt intneatuminum rallaM thrpugnlhe clearance VANCOUVER.WA 86889 holealoe itaiM¢fs steel ft.,washer.Place me Aainles,Meet n.washer an the PXON E'.(B00)BDB-BBBg —'i hole,orlenled,o me dimples willroma[t the 11m1w1raIL Plxethe Lug po— Gila,g,haptoo) nwidesolsr.rom Rh.bolt and-ihi ,Meet it.wafhtt InstatL fla bless Meet ftx wafher,lock 000 r ono nut Tighten the nut until the dlmples+re cdmpletety emheddedm— be—� TORQUE VALUE IOR to,. J 's Mad INO WEEBWGE1 MI SM STANDARD L •.:—.-- �..•. SINLIGHT RAIL .� -_.-_"---! ce ne4 GROUND INp LUG,dt,,bMOUNTING th DETAILS / - a Is are provided for ooth me WCEB M II prodlKts The WE[OL q Ms a ground N fy t located on me lug Ny Tn IUcn IUg has a green colored set spew for Around nq riti t w P design,P must hem �� al.[ xtwdarce with NFPA NEC)0,hovaeve Uie 1 Ideflgrier al reeved tauW rel"to the latest revision of NEC to,actual 9—.d,N cmNuctor cable size. nTtry_�•' / -/ , V TgXWALioaqut, Required it not ufingapproved Integrated grounding mitrainveters j%}y✓'`� ._.�� - : L�,"_C�_ a VERSION NG 106• S@ - [�� u so I.Awcnld w.� DESCRIPTION GTE REV CRWNO LIIG BOLT SIZE ORILLSiZE ILSCO LAY-IN LUG CONDIICTOR-UNIRAC P/N 003MP'.AltemNe Grounding INITIAL RELEASE 08 Ih1AE/ UR WEEBI.q t/4- Luq-DriLLd<bun hole aM bolt mru both rail walls per taole. IISCO UR a10 33 7/!a'in TORQUE VALUE S h lot. Torque vNu<depends an roMuctor sia See ILSCO p,odun data Mfeet for mare details,Model No.GBL-408T. • See Product data sheet fw torque value. NOTE:ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION PROJECT NAME ON t SM.SOLAR BONDING CONNECTION GROUND PATHS'■ MEN SM SOLAR ENDCLAMP& FIRST MODULE ■ ago: i iNSTALLATION GUIDE:PACE on MOUNT INSTALLATION GUIDE;PAGE a a 1 ........................................... ---...................................... / i rEt/ w v ZoZ �J, a 0 Z Do ,f Z a� ON, w� O . ZV�O p o� wSTALLMODUE ENOCLAMPS:The En,tamp Is INSERT ENDCLAMP TBOLT:im-l/4-T-ooltinto ROTATE ENDCLM/P T BOLT,ft—Tbolt rdo mnl Z Q N< BONDING MIDCIAMP ASSEMBLY BONDINfi MIDQAMASSEMLY BONDING MIL SPLIQ BAR MILTOLF00T va/BOIIDIIIG T-BOLT G suppled of an assembl The a Too1L serrated iaiL ton.Wrily that the wN[an indNAtor 6 T bolt MUR -J lJJ Q C Z 0A^ m � � IRargem,t.anewamer.Tnewame.retaim(ne areargwatnecmectOPMtan. H au.aM,�inM m ii1P1u" •i wr ©�"" aMa«[ao mPwbro darn"at the mp Uf lne asumbly This will a.W J�J Q2 ©sin.lesr,uei mn pmf,euminmu auanla.a a«i-uon ©`+ s .ii""`ua sn,aa the clamp to remain 1,ght for module installation. Endtlam—POMtlonedon As prior to 1.hrtt LLI� ©v s mrc.mralarcaunw„n eo-Hihwi.nw.,.am>..n „„ eiMmod,W,RRinstatkdefterthe Wot tM module. =J E - [T SHEET NAME an Na e. SPEC SHEETS aver srua y,LdBLi��tYlll� ' BONDING MRROINVERTFA MOVNT RACK STSTEM GROUND INSTALL FIRST MODULE-.I M Il heft and mod- POSITIONMDICATOR SERRATED TBOLT.Verify the POSITION - OTE SHEETSIZE INDICATOR NOM-SEtRATEDTBOIT: ANSI B O mme 0 r•„. « I N w +r, I -I E Sag od I f h Erb T Mil p sition ri0urtdr s perpend'cukr to[he Verify FOR bolt pot LL FINISH angled as clamps Verify mat the pos Lan ri iliotor 8 T bolt rail. mown.OR USE W TH MILL F N SN FAIL ONLY 11 N X 17" a� ---- - — ©�' ©� r, Slug arc arpled'n the wren posi[bn --,.'C TORQUE VALUE:1/4'nut,W l0 ft-lbt.wftn SHEET NUMBER �, rp• r.r.i r.a,.x, Anti Selee A PV-15 aL.a: a� CONNUCTOR WO-MN NATIONWpE SOLAR PO BOX 821959 VANCOWER,WA BB6B2 ■■ ' SOLAR BONDING MIDCLAMP : N 6 RUCTURPJBUIIOI NATIO6.186CW ELECTRICAL:NATIOS-)B6TW ELECTR GL Uo'%60R CO E BA801T LICENSE:ADSASABBICWI8802 S M ��■ MOUNT INSTALLATION GUIDE ; PAGE "atloVde- ----------------------------- ------------------------------------------------------------------------------- 0 NATIONWIDE SOLAR ♦ \ 6Q7 NE 117TH AVE.SUITE B VANCOUVER,WA M62 PHONE'(BOO)9OB-6882 EmeO:Beholer@myvdonxldesohr.com 1 1 O , y JL VERSION INSTALLMIDCLAMPS:Midclamp is supplied as INSERT MIDCLAMPASSEMBLY:Insert 1/4"T-Bolt MIDCLAMP:Rotate midctamp assembly and slide DESCRIPTION DATE REV an assembly with a T-bolt for module installation. into top slot of rail until clamp is against module frame.Do not tighten INITIAL RELEASE B &u DR Clamp assemblies may be positioned in rail near nut until next module is in position.Ensure bolt is point of use prior to module placement. perpendicular to rail. PROJECT NAME 0 Q r T O d �ofvZOpZ j WZ�pC,0 L U Zz :0o0 _j <"< uJw02Z J C,J a VLUH Q Q I =J PLACE ADJACENT MODULE AGAINST CLAMPS: POSITION INDICATOR-SERRATED T BOLT: Modules must be tight against clamps with no gaps. Verify the T-bolt position indicator is perpendicular Tighten nut to required torque. to the rail. SHEETNAME SPEC SHEETS TORQUE VALUE:it ft-tbs.No anti-seize. SHEET SIZE ANSI B 11"X 17" SHEETNUMBER PV-16 COMRACTOR IWORNUITx)N NATIONW709 SOLAR PO BOX n"S' VANCOWER.WA SSS82 saaecc LRElBt9L01NO'.WMOS-Itli ELEOTRIGL NATOs']661W U&'.60a]Ba6B5 S� ^SA Descriptive Report ELELTRICALSLFERVISO1-dedaABBITT (! LICENSE'.EWSOR cOL 02 Em.l GROUP ' :permdd.pi Qmyre onwN.m.,.nor Naficinwide 1, SOLAR♦ MASTER CONTRACT: 0000266909 REPORT: 70131735 ----•-----•—= PROJECT: 80219156 NATIONWIDE SOLAR 6M7 NE 117TH AWE.SUITE B VANCOUVER.WA 98662 PHONE:(8DO)BOB-0992 Fml:9eMOI,rQmyn.tlon W E,sobr.mm Edition 7Ts�uMUn Project Location PrcpercdBy Authorized By SM : COMPATIBLE MODULES 134s CchtionI Sepletnher 20,2017 70131735 Irvme Michael Hoffnagle Michael l loffnlgle WONI I -- _ on ; SYSTEM CERTIFICATION;PAGE Edmon 31 March 2G,2024 80198760 USA Irvine Michael Hoffnaglc Michael Hoffnagle Edttion32 July 10,2024 90215255 USA Irvine Michael HoiTnagle Michael HolTnagle ElectrlolBoMirrgandGrourNingTeatModule, --- Fdition33 'Au ust08,2024 80219156 USA Irvine Joseph Garcia Joseph Garcia_ n sh df,pmpiammoamesa,isnowstr,osemxroveneenevawxeaarmrounamxelec Alym mbu,w,i SOLOW1Otaosysrem. 1 ��toos.o00 s.pope.prcaolos.os ~ E1SK"' VERSION Tn�su. oec,s"c:a Aocusrc Ann vows..,«x«o DE6CRIPTON DATE REV Certificate of Compliance+Supplement-Page 1 to 14 eE'e•0F49''° IINTUL RELEASE Description and Tests-Page I to 47 " _ Ts-2- vw"... 0 OFt4.i9a1 uR -,pse"" AttI Installation Manual SM-Pages I to 51 Att2 Schematics SM/ULA-Pages I to 134 Att3 Installation Manual ULA-Pages I to 29 Att4 RMS Installation Guide-I to 23 ---------- - 1p1"•'�"'"�°B PROJECT NAME AU5 RMDT Installation Guide-I to 24 a.y.._. --u.w.w,u.«Q.we swMa-ss DaaWH1AaUN,p1»vMaAMMI "� h,a xnnn'S"q Anti RMseriesschematics-I to40 Att?GFT Installation Guide-Pages I to 42 " `+"'�fe"�'`N1iM6L n+arves.nx - r.a" Mod l,S "^a' Aug GFT HD Rail Installation-Pages I "°"' "" so-° Att9 GIFT Schematics-Pages I to 69 v.,>w ;.Eros oHr.o,wps AttI0 NXT UMOUNT Installation Manual-Pages I to 40 roa>swirxi. �d Attl1 Schematics NXT UMOUNT-Pages I to 147 asHp.,« 0 C r Att12 SM Ascender 2P Elevated Installation Manual-Pages I to 37 °ini a`"'N'"D°"' Z v z O j Att13 SM Ascender 2P NON Elevated Installation Manual-Pages I to 36 vHs,xH,_s,sv,p p�2 Q Att14 SM Ascender IP Non Elevated Installation Manual-Pages 1 to 33 >-U- N U An 15 SM Ascender I P Elevated Installation Manual-Pages I to 36 C,-Q Z O Z Att 16 Schematics SM Ascender-Pages I to 52 ZQ �O o A"17 SM Ascender Flush Mount Installation Manual-Pages I to 28 ..7)Z Q cJ Q Att I8 S-5 schematics and installation-Pages I to 19 :weess pthelwi:<nmed.all—les listed aooae imlude aa,wttign arm spume morels vdmm that series,v,r t4e w,t",are remesemM as"-,,*,, C e Wrenthesis are[haae,hx mar p maY nx be presem Ina[mnpatihle madnle's model iD LU LU 0 G C Attl9SM NXT Tilt Leg Install Addendum--Pages I to 13 •smsnesy'heneenoneorm�rehemsimisatess�xrimerormosrnemsmarxmeooemanspresentm,moeme:moxuD J 1- d 7 •The frame pro9le must not have any fexure[oat qi t 1-11 re with the MnalnO drvlres chat ara ImnJralM Imo the r+rking sycem •Use with a maaimum over cu,rem protection device OCPD of 30A a LU Q= Report pages reissued:All •Lined....,can kurea to xN—aa.,A n,e mt•m rxln9 for steep slope and I slope appacxl.ns.See MOe 30 =— Q Attachments Added/Revised:AttI-Updated,51 pages N Att3-Updated,29 pages This report shall not he reproduced,except in full,without the approval c CSA Group, SHEET NAME Irvine 34 Bunsen,Irvine,CA 92618 SPEC SHEETS Telephone:949-7334300 Fax:949-733.4320 SHEET SIZE ANSI B QUI3"Rev,202443-27 in2024 CsiA t'roW.All right,reserved. ��°x irr SHEETNUMBER PV-17 CONTRACTOR INFORMATION NATIOMMDE SOLAR PO BOX 92,969 VAN ER.WA 9e6B2 STRUCTURIDBUI NG'.NATIOS'7 W ELECTRICAL:NATIOS'79 UBI'.6aC SGR" ELECTRICAL SUPERVISOR:COLE BABBITT IJCENSE'.ADBABBICWlt16O2 CSA E_,Po_e.lx@myre,bnw4 W1a'ec S� CSA GROUP GROUP ceHincate:70131735 Master Contact:2t(9(N Nallo�ded► SOLAR♦ P,oJect:80219156 Date Iss,rd 202408-08 Certificate of Compliance treebtotsn.annmeing fors. Ann end chded The mAWC;duLs bonded to the Lab rt lI II satin T Us IngT.`LAR nud cnngn with percng poit,u."Ihe srt grounded lh 10 AWG q,per m to bundml/ETa ndinE IuL� Fire misue. f C.W.s A with NA710NVJIDE SOLAR Type I.2.3(with m in ar etank Ratre),4(wth tint),51 with m,).10(with—oink:fmnne),I9,_2,-5 29,or 10 for.,.ep slope.Class A with W7 NE l ITTH AVE.SUITE e VANCOUVER,WA9N62 Type I,L 29 or 30 for low slope.Tested at 5"nterslhnl gap which alkws iutalbi n m any suind-off hcgla. PHONE:(Sean 9Na992 Certificate: 70131735 Master ConlTacC 266909 Er J:fsnol..Dmyna,lonwiesulPr.mm The LTotmdu,g of the system is ntenled to comply with the latest edition of the Notioral Electrical Code,to include NEC 250&690.1Xeal P is remjeet: 80219156 Date Issued: 2024-08-08 cafes c I®nee o,ry qused n addition to ,imul caQs.AA ITandmgtwnd"u,q cavectiots ere to be torqued in accordance with the Issued to: Ulimc hntalati n Manual and the snnugs used luring the cenif ratin testing for mm the cue edition of the project report. 1411 Bma,lsmy NE S 16TMoun Tit Legs n a variation of tie SslarMount system dint,¢ilvc]strucmml stardotTanackrcnts,o e<liese n mrtEc of nxxhsle tiff Alh,que que.N'ew Mexko 97102 angles.The SobrMo nt-1,h Legs rsmllatkn mtructntn are capered in an In tallahon AdkM,m that casts both the SohrMom,I Tik United States Lcg sys,rm and,he Nh7 Tit Leg system Sob,Main,Tile Leg has mechanical lard mtngc i deperdent of the Solar.Malm not N)Cf UMOUNT mechanial kad rating. Attention:Roh D'Anastasia VERSION ll,c system may crrgrloy,lpiI111SR!RdCR>-mverterl and used for groondi n!when n 11ed Nr vtttalbtin.,ructions. DESCRIPTION DATE REV The products listed below are eligible to bear the CSA Marls shown with adjacent NITIAL RELEASE of-,4-0aM UR I Atest So6rMouml Install Mamml revkin:PUB2(YIAJULI2 indicators'C'and'US'for Canada and US or with adjacent indicator'US'for US only or without either indicator for Canada only. Le,cs,Sn arMamt NXT Tik Legs hit nlbt inn Ad e,din reunion:PUB2024JAN I S PROJECT NAME SnbrMnut UL 2703 Meehonical load ratio: Jt" G—io S ® Ixsucd by. Aesign Dad up u,22.2 sq R Joseph t78mm Ibwnward Design Lad(biR') 113.3 0 Fllw�xw Design Lxd 11Nn') 3n.7 a CP uS lbws-Slope lined lk,7N1 _ 1613 }} D��o~ rn XaZoZ 00 r Moduli Arcs un to 27.I2 sq ALU Z to O 0)O n Dowward Design Inad Wnrl 1 33.9 0 U 00 U N U ffi41Z1i06 t y,w:ra Design Lead ib/n') von-- o 0 >O Q Z o Z ... _ > O Class5313 02 POWfR Sl TPI.IfC P11OTt7VOLTAIC'S--PV Reeking Ik�wn-SkpeLoad(bill') 16.5 Z---- .— U N 1n Class 531382 POWER St 1PP1 IDS-PHOTOVOLTAICS-PV RacksVa Icla TlsiV system-Certiid to US Shndard ..__ ZQNQ Module Arcs up to 29.49 s4 R W LU O 2 SOIARMOUN'I'Hush-to-Roof N an extruded altmintan nail PV mcki,ry;system that is installed parallel to 11e roof in n,w re.nl Dolgn lard(Nit') 71.18 J 0)J d landsca�orInrtmit orientntione. the rd Dee yin Loud(Nit') 31.18 at LU Q Q Uni.,I arge Array is a gro-d nnu 9 s3h tea using the SnlarMrOW(S11)platform forth,hooding and grounding of M Lo.n-Slope Land I bRP). 9.8 f,A ImdWes. SnhrMrnaa Test Laads: EDdeYsl SM.UVs ModuleAxe up b 22.2 p It SHEET NAME __... Downward Load INn'1 I7020 1lpwrrd lnaJ tna'n') 7ts.m SPEC SHEETS —ourlMo,mt Down-Slope load(biR') 24.2 SHEET SIZE The system fisted is desigd to pmvidc Mndinggro inning,arcl mechanical stability for phutovokac n ndules.The system is secured to the Module Ann tow 27.12 p A ANSI B roof with the LFool cunporenlrs through the roofing ITnterul to building strucnce.Modules arc secured to the racking system with smnkss 11"X 17" 1XA Im Re,2019d430 C202a CSA Cm .Nl ndaa om 1 P_ QR]Y7 Pit 2m9-04Jr1 C'Jt24 aik(kip.Ak right, d hp: SHEET NUMBER PV-18 CONTRACTOR INFORNIAMN NATIONWIDE SOLAR -SOx B2IS. VANCOWER.WA 98882 STRUCTUREIBUILOINo NAT1C15'788CW ELECTRI-WnOS'786w/ UBI:BDa7Bo895 ELECTRICAL SUPERVISOR:COLE M913mr LICENSE ADBA43BICw18802 Em•1'.permBE•p!@mlmetnnvMesobr.com 701 Engineering Alliance,Inc ��� Engineering Alliance,Inc NationvAde2 https.11www.engallionce.com https://www.eng-oIhanrn.com SOLAR♦ 11-December-2023 Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape-PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is .._.��.��..�...�..� Unirac mounted on the long side. NATIONWIDE SOLAR Portrait-PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel Is _7 NE 11TH AVE.SURE B 1411 Broadway Blvd.NE VANCOUVER.WA Mn Albuquerque,NM 87101 mounted on the short side. o h•I.rQ(8y0"E-1: awl.r.wm Tel:505 242 6411 M Components and Cladding Roof Zones: Attn,Engineering Department The Components and Cladding Root Zones shall be determined based on ASCE/SEI7-10&7.16 Componentand Cladding design. Subject:Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. The Unirac SOLARMOUNT Flush-to-Roof Is an extruded aluminum rail system that is engineered to hold most framed solar 2. Risk Category II per ASCE 7-16. modules to a roof structure and installed parallel to the roof. 3. Topographic factor,kzt is 1.0. 4. Array Edge Factor Yt=1.5 We have reviewed the SOLARMOUNT system,a proprietary mounting system constructed from modular parts which are S. Average parapet height is 0.0 ft. VERSION intended for rooftop installation of solar photovoltaic(PV)panels;and have reviewed the U-Builder 2.0 Online tool.This U- 6. Wind speeds are 1-RFD values. DESCRIPTION DATE REV Builder 2.0 software includes analysis for the SOLARMOUNT rails ISM LIGHT rail,SM STANDARD rail,and SM HEAVY DUTY rail) 7. Attachment spacing(s)apply to a seismic design category E or less. INITIAL RELEASE nHa UR with Standard,Universal AF,and Pro Series hardware.All information,data,and analysis are in compliance with the following codes,city ordinances,and typical specifications: Design Responsibility: The U-Builder 2.0 design software is Intended to be used under the responsible charge of a registered design professional where Codes: 1. 2015-2021 Washington State Building Code required by the authority having jurisdiction.In all cases,this U-Builder 2.0 software should be used under the direction of a 2. ASCE/SEI 7-10&7-16 Minimum Design Loads for Buildings and Other Structures. design professional with sufficient structural engineering knowledge and experience to be able to: PROJECT NAME 3. International Building Code,2015-2021 Edition w/Provisions from SEAOC PV-2 2017. 4. International Residential Code,2015-2021 Edition w/Provisions from SEAOC PV-2 2017. •Evaluate whether the U-Builder 2.0 Software is applicable to the project,and S. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels, •Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. November 1,2012 by ICC-ES. 6. Aluminum Design Manual,2015&2020 Edition. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush,when installed according to the U-Builder 2.0 engineering fQ d report and the manufacturer specifications are in compliance with the above codes and loading criteria. >- Following are typical specifications to meet the above code requirements: O=�:o This certification excludes evaluation of the following components: IX It Z O Z Z 00 O CDDesign Criteria: Ground Snow Load=0-100(psf) 1)The structure to support the loads imposed on the building by the array;including,but not limited to:strength and W_U)O rn O Basic Wind Speed=85-190(mph) deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects of snow V m O C4 U Roof Mean Height=0-60(ft) accumulation on the structure. >Q -Z Roof Pitch=0-45(degrees) Z 2>O O 2)The attachment of the SM SOLARMOUNT Rails to the existing structure. U) Exposure Category=B,C&D 3)The capacity of the solar module frame to resist the loads. g M Z<N Attachment: Shingle Roof: Q Z L-Foot,Flashkit Pro,Flashloc Comp,Flashloc Duo,Flashkit Pro SS This requires additional knowledge of the building and is outside the scope of the certification of this racking system. J h��(L Metal Roof: Cl)W Q= Standing Seam attachments,PM-9000S,PM Adjust Slotted Please feel free to call or email for any questions or clarifications. QO� =J Q Tile Roofs: y9 - fn Solar Hooks,Tile Replacement tAQ' • O'.s D Attachment Spacing: Per U-Builder 2.0 Engineering report. Prepared By: tN Zj Engineering Alliance,Inc q I Cantllever: The maximum cantilever length is L/3,where"L"Is the span noted In the U-Builder 2.0 online Sugar Land,TX Gftsa7 tool. � AL_.C1 SHEET NAME Clearance: 2"to 10"clear from top of roof to top of PV panel Tolerance(s): 1.0"tolerance for any specified dimension In this report Is allowed for Installation f SPEC SHEETS t i-DEC-2023 exP.:15-DEC-2025 SHEET SIZE 4603 April Meadow Way,Sugar Land,TX 77479,Ph:832 9654757,Email:sahmad@eng-alliance.com 4603 April Meadow Way,Sugar Land,TX 77479.Ph:832 8654757,Email:sahmad@eng-alliance.com ANSI B II X If SHEET NUMBER PV-19 CONTRACTOR aIFORIMTION NA—q E SOLAR Po Box a21959 VANCOWER,wA Basso STRUCTUREISUILDING:I'iATIC S-78i ELECTRICAL NATO—67w UBI:6D4TB069 EEC R I 5 VS�� ,—B PESORCOLEBABBITT LICENSE ADBABBIC Electrical Characteristics at Standard Test Conditions(STC) COLE Emea:perm4deplB�mynalionwitlesolar.com IgnOVaTiV! & $mitt Module Type V UN3101206NH 11UN365-12-11 V5UN360-128BNH VSUN]55-1200MN Ma.imum Power Pmar(WI 370 365 360 355 NaflonwideP open CkcVil Vollage'—ry) 41.4 41.1 — 40A SOLAR♦ Shan Circuit Current-Is,IA) 11.26 MAY 11.12 IL06 Meaimum Power Voltage-Vmpp151 34.5 343 34 33.T MA a—.Power Curren-Impp(A) 10.R 1066 30.59 Io33 °-'•'--�^' ModuleElficiency 20.04% 19.TT% A.Sn'A 19.2M NATIONWIDE SOLAR Sunder!Teat fendlooe,ISTC):imdiancet• Wm;AMt;module temMAP.,25-C Pmaa Soning:p-Sw.Meesunng Tolerance:23.6. g40T NE i t TTH AVE.SUITE 25 30 Remand Electrical data tlo of tern tea n le madulea tlt he oRer The or com different matluk VANLOWER,WAB98s2 g n dryarenot peso yonyxrve pansorramong types. PHONE:(E,WA962 Emafl:peboNr®mynetlorrwidseolr.cpm YEAR YEAR PeoWN) Vum 1.(A) Vmp,(V) Imyp(A) IInM(A) 388 41.40 11.8E 34.90 10.38 5% 40T 41.40 12.39 34.50 10.88 1016 N3 41.50 13.51 MAD 11.17 2U% VSUN370-120BMH 461 41.. 14aA 3440 35» VSUN370-120BMH VSUN365-120BMH Material Characteristics VSUN360-120BMH VSUN355-120BMH 1imen:iona n62x1048x35mm(LXWXH) m, e5•G(3re) VERSION Weighl 196kg —1�1.- -o2las C DESCRIPTION DATE REV White anodizrnf foygl prollk Cumnt Temperature.111deknt '4.12%VY INITIAL RELEASE OM41a14 UR Front Glass WhXe toughened selety glau,3]mm Power TemperahsreCuRicknt -0.1296/'C ['ell Encapsula[lon EVA(Eth yi—Vinyl Acetate)or POE 370W 20.04% Bx—l— Transparent meal,W<k neet Highest teas 12xlD metes bllecul moracrysUlhne ider 9 power output Module efficiency �ensurrea sUings Mealmum System VeXAge ry) IOODJI500 unction Bos m68,3 diodes Series Fuse Rxhng(A] p PROJECT NAME Ce01e8tonnrno, fable lengt0=IIOOmm Bll,ckily TO%35% ConnectorMC41%4mm, A80UTVSUN Invaded by Fuji Solar,VSUN 50LAP is a solar solution provider with Dimenaionx(LZWx HI 1B20z1125x 1181mm Tempwatu,e Range <0'C so flS'C headquartered in Tokyo,Japan that nlf—reltablbty,high efficienry, Contelner 20' 186 Maximum dlamMm or 25 mm Q d WlMslanding Hail (n Solar poductsardtechndogygloOBlIy VSUN is raretl as BNEF Tierl Contalner40' 403 wiMlmpxtsBYdM23aA/s KEY FEATURES pVmoduleroanur3cturer,PVELLab'Bestperforrner'andEcoVadis .-PxmSanac.Load 5.sDOP, 'Errnze Award". contMner 40'HE 906 c),Z Applitatbn lass ctnsA �Z O LLJz t17�8 oez PERC Cell Technology Dimensions }.4 ED V C1 O m U N V Gt Higher output power PRODUCT CERTIFICATION a U A-A 0 Q Z Z P }� Lower risk of microcrack - CE eyna ® ® N� _ Z OO N Q ` .. z¢ © Positive lolerenu offer h-0 d j Lower risk or hot spot g I V U1 Q= PRODUCT CERTIFICATION _ rwaanlw Ike• 777���...---..��---..����4� =J Q d Banat shading tolerance 4 y). CedlfM1ed for selt/ammonla corrosion '.b Munich RE _ re,at..- •Lo�wr:v ym,A'.er Mea31 Load Cerllllcatea:wind to 2400Pa and MBja'4 i'-� y[ O snow to 540OPa U �° Ni3' g t SHEET NAME a Lower LCOE ' SPEC SHEETS lea t t>A2t w'wm� 3■ WUN •were W— PHONE Yin MR TIY e.rs.+--a.-.r4e...e... SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-9 CONTRACTOR INFORMATION NATIONWIDE S01 PO Box 821959 VANCOUVER,WA 98662 STRUCTURMOILDING:NAMOG-786CW ELECTRICAL NATIOS`/861W UBI:60e709696 / OLE C BASS T'T SoIarEdge Home Wave Inverter ELECTRICAL SUPERVISOR 12 LICENSE AOBABBIC DLE SolarEd a Home Wave Inverter Eld OemilCePtEm a110m Cambr.om g z For North America NaiionW eo For North America C E,0000H us SE1140OH-US so I, Q SE3000H-US/SE380OH-US/SE5000H-US/SE570OH-US/ m SE6000H-US/SE760OH-US/SE10000H US SE1140OH-US OUTPUT NATIONWIDE SOLAR 6407 NE 11 TTH AVE.SUITE VA VANCOWER,W IN00.24D✓ PHONE:I000'908-8992 8A992 MrFvnACPd OIW I= 100W �/ VA E-1:9etsoWr�myna lorNAOesdr.com O,l�A Al VRBage Mn_Nwn-Mv. • 2tl Ya _ TNwµn- -M- V V. ._ ........ --- - —s ----- • O AC,163-208 Fr lN9rr✓wW 593-6D-60.Y w MainunCarFraa CURet•141V Q O.I A MNnum(reruee Cadre•MW 485 A FOAr Fetbr t -aswoas O • _GFd TNre#00 t A C ".ftkh VERSION I T DESCMI N DATE REV MaeRxn DC Purr•240V 1550D 1765D w • eder.�.±? �� • mlxr,�,Tj .JI ID M4viNm Dc P e288V Issm w INITIAL RELEASE 09.1436M UR • • TrrwmN+ea Yn V 49D Vh • O N I DC"VOIN7e----_- 3w V& I.taxhn�rn Irpx cu-1 o"',' _ n 311.5 Ah O e W.—lipsc-01 27 Ad, PROJECTNAME MID.tU SNOB C_Cu"ere 45 AY � Rex+SePdm6y Ndecxn YIN • e e o Gro -rWt wWon Dehctbn 600x _ _ _ Mmnun�imrtn ykr+ 933 % - CEC We Pw EN wi 9050�208V % <zs w a ADDITIONAL FEATURES ` Optimized installation with HID-Wave technology "'Cr"e"CeN°"'"" E"""""`"` "°""""°`p°°°"'9�'""�` `"d' Z o Z Powerry AN9(V 7D w Z cone, Met V)O m O encAe Commis wm 6e mob WN.W.,A—I gWlW I—I Crngpn }Y� �(-) / Specifically designed to work with power / UL7741 SA certified,for CPUC Rule 21 grid C]U CA Z N RyNO L 690.n-NFC 20N-2023 V.+s4k. optimizers compliance 690II stl 69D.4 AMmtik RepM SleAdu<m upon AC Cana DNcaw[t ��Q Z O Z STANDARD COMPLIANCE Z U 5 CO O / Record-breaking 99%weighted efficiency / Small,lightweight.and easytD install both sir -- _-_"-- coiiymsio uL nn ui i�iiSn u nat5a Ia issse g Z Q N Q outdoors or indoors Cwtlfio b CSA 221/101.1 C2214330 CT23PA AN54cANAA 9510 / quick and easy inverter commissioning directly GRB C°nrok°"5taWrae eLEI54T Wd EEE-ISGA MY 21 Rde NN-- J O from a smartphone using SoIarEdge SetApp / Built-in module-level monitoring E'"I"9fS-_.- _ _..... rccPanls.[Lea 03 J r Q= INSTALLATION SPECIFICATIONS LU F Q / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in AC kW CORonwlslx 7 AWG d rtt.mxxn/t4-4AMG C0J OC xIPx Oq Sire/P /AwG 1'L/aerrexn/1-3 /M-6 AMG (- consumption metering 0%accuracy)and CM�mxiorenl8r SWAN DIxWr 21D6x N.6,73/s35,3M,185 2LD6e M6e01/535Y37D.Ma^ W— / Integrated arc fault protection and rapid production revenue grade metering(0.5% wxt swlmi 3ae/17.6 44a/2II4^+ er shutdown for NEC 2014-2023 per articles accuracy,ANSI C12.20) Nobe <50 .•^ _ 690.11 and 690.12 weir camr9oR R-p -4C..ND/-40..611. T/Y SHEET NAME Wotealen NE MA 4x6"wRw S ao.. eR+.+P+..�Ee.Eae.EPRL SPEC SHEETS ';A I.yv".r+m.wr�rA E.e.�.w Iti a IwAa.wn a e..ra.e. ?.I,..n..nx.....6mPR,fesm etlCepelelmAMr IVIt SfmMIR06aY w mrw;Feoe e.l.ero Rnwee.eEa""e,et,4a raa..4Muwv sFACToni29olu-m w sFACTmv-<aaN+-axmvelep.I.n. SHEET SIZE -;1;f!'NW"USmtlM nbu9eelM VN,6RixP SlINOIHiRa,ret eN eE a eMitrx..Mpurare b.nflNbbou modE kX'-l4rK ve rint w Ene,me IrUWtlI: rle JxeeamwntrsdY11m1IEoMMw3U/RAL6fIgINriOf<L6.]3/535v3A<g3NNm,Larsabgy ANSI B solaredge.comsolar�• 11"X 17" SHEET NUMBER PV_10 CONTRACTOR INFORMATION NATIONWIDE SOLAR PO BOX 82196P VANCOUVER,WA 8BBB2 S TiUCTUREEUILDING:NA7IOS•2B6CW ELECTRICAL NATIOS•286TN UB I:-- ELECTRICAL SUPERVISOR:COLE BABBITT / Residential Power Optimizer LICEN Email:permSE.ADBABBICN"BBD2 Idepl�mynatiomvitlesoMr.com Residential Power Optimizer O For North America Nationwide.Pi ElFor North America o S5006/S650B SOLAR* 5440 S500B/S650B g1Nryuta Pe1` 60 w _,N.ATIO NWIDE SO IDESO LAR T A n A e Ma Mien bP R V ryoO 60 25 85 Yd 6 0T NCOLNER AA 98 62 MPPE R 8-60 12S-VS 12.S-8S Vd[ VANCE(800,WA98582 OluZ a t PHONE:(B00)900 i i Maxiaam l shi c Oeaanm NtW Caw«tM PV MahMI %5 15 Atic Email:geryolar®mynattwrwldesdar.mm MaxMxlm BYAa Sh«t Chad Cur«il0YEAR 18.75 AAc Maxweml 01 99.5 % O WekfeME 911 -AO ,. A mrxMra9e G egmY II '0 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Ma martvWc I AOC leaaerurn O.rlp IJW1aya -_.... 60 I 80 I Vd, OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR INVERTER OFF) — sa4ryc imut voltage,'_'o"irrirer STANDAR shi COMPLIANCE VERSION TOW�Mex P RIM apq slutdpwn Sys%m _ NEC 20%-2023 _ DESCRIPTION GATE REV Ell KC 115 Om 9,IEC 601 IEC 61WD-6-3 5dely — UR IEC U109.1 IOa%E gill UL 1241 INITIAL RELEASE OB-16302/ UV ftslhPft N RaR6 yes —. ree Sde y WEAR-E 21o0-11221N3-GS T INSTALLATION SPECIFICATIONS PROJECT NAME MaxirunrNbxetl System Voltage Y100 Vd, T r 5jD?155 x 30/Omcrsbn(NxLVH) 129x165s A5/"a 01x6a9,1.1/ mm/In SAla6.10 a/.18 We' TA/16 A0/1.2! /b kPACarlrxTtgr MCe F Wee DI/032 m/a Q CE CNtpalE«m«ur MCA ov"PAwre (.12.3,E)D.V/HI 2.KE)032 PV power optimization at the module level '°i c Z o Z P-otecibn Raling a68/sSi W Z Z O RebwINOmBlly, D-1oo % O rn O t Specifically designed to work with SolarEdge / Faster installations with simplified cable „s,cw�«"x«tlmeP=..*=w x=•ILAv ex,.xr,a,,,,,A,v,,,,, w,v„ ,rq,,,r,,,,a,,,d. O(Yj DO U N U residential inverters management and easy assembly using a single aI,�Nev is m�v�.re«mexegw.xa.w.a:exaxnmm a.wenr rcrro«w«...r.a:e.a+a+ ..rom�m.a«a.....u..ac.e Z bolt alw.wa«.i:vxro7xda.mrn wro«aw.r+l�.-as•c/.ms•r a.way.Mxrr.m,.M xmreM,re,A.,K. cr,arrr„ssxa u"..mr _ Q Z p leeaurv"a mR.aa, Z �O o O / Detects abnormal PV connector behavior, U [J)N U) preventing potential safety issues / Flexible system design for maximum space Z Q N Q utilization J W O:E Z 2 Module-level voltage shutdown for Installer µOle Mio SB Letglh Ili -6 -' —iers) 14 - J CEZ OptIn s 1 S6SG8 6 B and firefighter safety / Compatible with bifacial PV modules Abxataxn sadly l«OA P«.croPd 1---- _ -- zs —---- sDv UJ tZ Q =J Maxmrnr Usable Pgaar DeMered P«6vi1g _s/00 B000 II./50 W U) / Superior efficiency(99.5%) / Meets NEC requirements for arc fault Ima Iftl ded PF me,reaYsrt�ilunpe�t protection(Al and Photovoltaic Rapid AC Paws 520OW a / Mitigates all types of module malnatch loss, Shutdown 5 tem(PVRSS) IAa"nAn ABvned Camcted Imae%rswftl s200 Is,t00 w Ys Paw P«SMrgr'm AC Pow of fi000av Teo safirgs arc .."/B00 from manufacturing tolerance to partial Parald% d CMMI:m a w 6800.ma y wlxMO on « shading pp*flb Ye SHEET NAME SPEC SHEETS m awN u e. �Pnm x raw a xRr.eus m E«N a%v P6 ew nwxrxxx I,q«x+a,d«y x,wr Me¢aa.ri«a mom wNw IaN«n mmp,a t.am w«lea m a«ere zRo v«m/"p v PrMy e.nr«,raan x PemAl,e«rry.lrm h alkwnm M mr.�«.a p«m Iaexeen axx'91 x,aoP w«ar. SHEET SIZE ANSI B solaredge.com solar • w.r'°`a". "."` ."":®x:`,+<°". �.:m�p�e, ua �.«""""°""" RoNS 11"X17" SHEET NUMBER PV_11 CONTRACTOR INFORMATX2N NATIO E SOLAR PC BOX B21989 VANCOUVER,WA SSS82 STRUCTUREIBUILDINO:NATIOS?W9 ELECTRICAL:NATID—TW USI:SWi .1 ELECTRICAL SUPERVISOR:COLE BABBITT LICENSE.-138ICWlB302 Emei:pem.meol�mr"auw.,;eesabr.�m PRO SERIES END CLAMP PRO SERIES MID CLAMP /"BOLT LOCATION Nalionwideo► T SOLAR♦ I�6 L ifi" 11V" ....NATIONWIDE SOUR ITTH + BGP O E:(BD)W8SUREB V NCOUVER,WA 98882 97�I" PHONE:(BOB)808A992 ol Eme9:getwbr®mynellomvleefolBr.tOm 30mm to 51mm MODULE FRAME PART#TABLE 2 P/N DESCRIPTION 302035M ENDCLAMP PRO 302030M MIDCLAMP PRO-MILL VERSION 302030D MIDCLAMP PRO-DRK DESCRIPTION OATS REV LF INITIAL RELEASE 1-1 24 UR BOLT LOCATION PROJECT NAME PART#TABLE p MID CLAMP P/N DESCRIPTION LENGTH <D_ 320132M SM RAIL 132"MILL 132" p 5�o 310132C SM RAIL 132"CUR 132" W Ofob�oO j 32016BM SM RAIL 168"MILL 168" Q U O r O END CLAMP 310168C SM RAIL 168"CLR 166" p L o I: 32016BD SM RAIL 168"DRK 168" Z o N 320208M SM RAIL 208"MILL 208" Z Q N Q WwO2Z2 3102OBC SM RAIL 208"CUR 208" J r,F- d J 320240M SM RAIL 240"MILL 240" W QEND CAP Q INCLUDED WITH END CLAMP 310240C SM RAIL 240"CLR 240" 310240D SM RAIL 240"DRK 240" DRAWING NOT TO SCALE �� PRODUCr LINE: SOLARMOUNT DRAWING NOT TO SCALE u U N I RAC PRODUCE LINE: SOLARMOUNT .� ��• ALL DIMENSIONS ARE �� U N I RA ALL DIMENSIONS ARE C SHEET NAME DRAWING TYPE: PART&ASSEMBLY NOMINAL Q DRAWING TYPE: PART DETAIL NOMINAL n 1411 BROADWAY BLVD.NE PRO SERIES 1411 BROADWAY BLVD.NE SPEC SHEETS ALBUQUERQUE,NM 87102 USA DESCRIPTION: PRODUCE PROTECTED BY XBJQUERQLJE,NM V102 USA DESCRIPTION: STANDARD RAIL PRODUCE PROTECTED BY 'n PHONE:505.242.6411 BONDING CLAMPS ONE OR MORE US PATENTS PNONE:505.242.6411 ONE OR MORE US PATENTS SHEET SIZE WWW.UNIRAC.COM REVISION DATE: 10/26/2017 wWAN,uNiRAccoM REVISION DATE: 9/11/2017 LEGAL NOTICE SHEET LEGAL NOTICE SHEET ANSI B 11"X 17" SHEETNUMBER PV-12 CONTRACTOR INFORMATION NATIONWIDE SOLAR PO SOX 821%9 VANCOBVER,WA 9G062 STRUCTURE/SUILDING:NATOS'186CW ELECTRICAL NATIOS•78- USI60a1S0695 ELECTRICAL SW ERVISOR.COLE BABBITT FLASH KIT PRO dwn U N I RAC E FLASHKIT PRO U N I RAC ❑CENSEADR/.6B.OWISBO2 Emea:CENSE A11nauonwlaeeoleccom IN RIBBING A SHED B SEALucxenmcr INSTALLATION GUIDE FEATURING Q SHED O SEAL n c NN a 10Sl SOLARI FLASHKIT PRO is the complete attachment solution for composition shingle roofs.Featuring Unirac's patented FLASHKIT PRO IS THE COMPLETE FLASHING AND ATTACHMENT SOLUTION FOR COMPOSITION ROOFS. OLAR SHED &SEAL technology.a weather proof system which provides the ultimate protection against root leaks. 6 NA 5I1"H VE.SUR S WA Kitted in 10 packs for maximum convenience.Oashings and hardware are available in Mill or Dark finishes. VANLOWER. 966fi2PNONE(60R.906A992 Email:Selmbr@mynallomvl0esdar.wm With FLASHKIT pro,you have everything you need for a quick,professional installation. INSTALL FLASHKIT PRO FLASHING INSTALL LFOOT ATTACH LFOOTTO RAIL Ir PRE-INSTALL olive the lag bolt down until the Ltoot is held firmly in place.It is VERSION normal for the EPDM an the underside o(fhc stainless steel backed DESCRIPTION DATE REV locate rout rafters and snap chalk lines to mark the installation EPDM washer to compress and expand beyond the outside edge of INITIAL RELEASE GA—GGEA EAR point for each roof attachment. the steel washer when the proper torque is applied. Drill a 7/32'pilot hole at rich Fool attachlnenf.rill each pilot hole TIP: with sealant- •UsecautionWavedoveFtorquringthelagholtitisinganimpactrimer PROJECT NAME STEM INSTALL FLASHKIT PRO FLASHING •Repeat Steps I and 2at each roof attachment Taint. AcidaU-sharedheadofFoolscalanttotheundersiden(Wenashing STEP3 ATTACH�FOOTTORAIL with the open side of the U pointing down the Fool slope.Slide Q the aluminum flashing underneath the row of shingles directly up Insert the included 3/8 16 T bolls into the lower slot an the Rail cA 1 slope from the pilot hole as snowy Align the indicator marks an the (sold separately),spacing the bolts to match the spacing between 0=)I CD F ower end of the Gashing with the chalk lints on the roof to center the goM attachments. Z o Z the raised]rule in the flashing over the pilal hole in flue,mul.When W Z� o 0 installed carrectly,the noshing will extend under the two courses at Position the Rail against the L-Foot and insect the threaded end of Y co O v� shingles above the pilot hole. that Bolt through the cortmomns slot in the Lroot.Applyanti-seve U m U N Z to boll threads to prevent galling of the T bolt and included 3/8` Z U<O o OZ fingered Garage not.Place the 3/8'Gunge not ec the Lbhl and to w STEP 2 INSTALL LFOOT finger tighten Repeat STEP 3 until all LFeel are secured to the Rail g LU ZO 2 a 2 with aT bolt.Adjustthe level and freight at the Rail and torque each � F— Z .. •Fasten Lfoot and Flashing into place by passing the included lag bolt to30tt lbs. rn > Q= boll and pre installed stainless steel backed EPDM washer through = Q TRUSTED WATER SEAL FLASHINGS YOUR COMPLETE SOLUTION CONVENIENT 10 PACKS the L foot EPDM grommet,and the raised hole in the flashing.into cl)d ~ nLrUeLvcfISHED.SEAL ncNNomor Flashirlgs lags,continuous slot[feet and]ranlware the pilot hole in the roof rafter.Packaged � SHEET NAME THE COMPLETE P ROOF „ ATTACHMENT , SOLUTION FASTER INSTALLATION. A ' A R WARRANTY. R11A SPEC SHEETS SHEET SIZE FOR QUESTIONS OR CUSTOMERF r FOR QUESTIONS OR CUSTOMEROR r ANSI B 11"X 17" SHEET NUMBER PV-13 CONTRACTOR INFORMATION NATpNWIDE SOLAR PO BOX 8]1959 NOTES: -COWER,WA 9B882 STRUCTURMUILOING:NAt105'1NCW 1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURERS WRITTEN SPECIFICATIONS ELECTRICAL:NATIDs•786TW : AND INSTALLATION INSTRUCTIONS. ELECTRIou 6N7806B5 SU UBI PERVISOR.COLE BABBITT 2.PACKAGING:KITS OF 10 LICENSE.ADBABBICWr 2 Emai:permitlrol�mY^atiomntlesoWr.com - Nationwide y SOLAR♦ _ NATIONWIDE SOLAR 640 NE i17TH AVE.SUITE 8 VANCOWER,WA 9NU PHONE:(800)908499 �•Q� E-11:gad W,@,yOall—I-Id =M 12" 1 7/e ® II wAwM: VERSION DESCRIPTNIN DATE REV INITIAL RELEASE OB•14i02{ UR 2" 81, SS SERRATED T-BOLT PROJECT NAME LL RATED FLANGE NUT -FOOT WITH GROMMET 1�" ;/e" o W/S x 4" LAG BOLT U d W/SS EPDM BONDED WASHER 27/8" zoz ww z �Yco0-'r pUrnUc.IO zv30o0 8"FLASHING g Z Q N Q J0)J o PART#TABLE _ Q Q Zi P/N DESCRIPTION F 004055M FLASHKIT PRO MILL 004055D FLASHKIT PRO DRK -- _...._._._........ - - SHEET NAME ��•U N(RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE C an• ALL DIMENSIONS ARE �'� SPEC SHEETS DRAWING TYPE: KIT DETAIL NOMINAL a 1411 BROADWAY BLVD.NE SHEET SIZE ALBUQUERQUE,NM 87102 USA DESCRIPTION: FLASHKIT PRO PRODUCT PROTECTED BY (A ANSI B PHONE:505.242.6411 ONE OR MORE US PATENTS 11"X 17" WWW.UNIRAC.COM REVISION DATE: 4/28/2020 LEGAL NOTICE SHEET SHEET NUMBER -- PV-14 CONTIUCTORINFORNATION NATK)NWIDE SOLAR SM SOLAR CODE COMPLIANCE NOTES: .;� SM SOLAR STANDARD SYSTEM GROUNDING BTRUETUR�BOX NG: OS.766CW MOUNT INSTALLATION GUfDe PAGE on COUNT INSTALLATION GUIDE,PAGE ELECTRICALNATIO5 W UBI11111 b655 EIECTRICALSUP DBABLIC-8802ON BBITT UL2701 CERTIFICATION WRONG LABEL „r••�� - u2'111_ - hoe / UC 5 aelCvn8802 Un 50LARMOUNT'�Fled[ UL2705Catl0catlon mxtl IS embossed on all mid Cl uMRac _ Emeil:pe td @ ynalihnw tlesolar.,om r9 the do Lab ell Myth Y Sinplp Usp Only M � add'[ L fo t o Ill b p v ded.ARet the,.,Ling system't fully assemMed a s ngle Ubet slwuld W applied o the SUlARMOUN E a L t the edge of the Wray Before applying the label,the corners of the label tort do not pertain:p the yst being iMLMmurtbelemovedsoNrtmlY[IeinsuOedsYstemrype:snowing. `` ./�/ NalionWide.: Note:The sticker label be plattdsu<h W[It is wslble out not putwartl Uc ng. C US ONLY ONE LUG PERRQY OE MODULES: j,ya SOLAR♦ 0 Iy I e per a of ddities is 24G909 rep M See pr I.p. ,diurnal 9 q d or e.p I'rts. � L NATIONWIDE SOLAR WEEBLUG CORD L, OR UNIMC PM 0000025 6a0T NO tNVAI AVE.SURER Seize and insert a bolt in the aWTn—,u[ through Mecleara.. VA NO 1177HUVER,WA 98882- ..., holeinthe stainlesss[eel Nc washer.Plate the stainless sVel.Ile washer on the PHONE.f800)908.89W bolt o,i,,I,dsoIle dimples will co mac[the aluminum rail Place the lug portion E-11:geneolar@mynatlanwldesolar.cdm me bolt and stainless—I Rat—nJ,B,Imtall sUlnt-1-1 flat—rer lob ,en washer and Z Tighten the not until the dimply are contptetelyembedded iota SooTO and T011QU Wg. ___ .-- TORQUE vAIUE 10 R on. Sooppd deM lheMb deledelelt,Modal No.WEEK-WG67 UG ca......`.... ._ GROUNDING Lyn,MOUNTING DETAILS: nd lug U nt poses IWolutonh s green SM STANDARD MIL "" --/ $M LWNTPAIL - "-! groundi D to dance tM1 f.A NEC 70,Wind—N NbettnOly l�conOucCArazwotedsl¢uld 9 [o the latest revision of NEC(or actual 5 ng apuF. Requ'cd If not us ng approved inlegrated grouts ng micro sveten .,'�'�• /� I- / / s �r VERSION •BOLTSILEGDRLLL K' .AM4.io nova DESCRIPTION DATE REV GROUNDLW BOLT52E DIUUsm I1.50)JOHNWfiCOlIDIR70R-1110RAC WIN 00B00WAllernate Guound ng INITIAL RELEASE OB•1430E4 UR WEEBLu9 1/4- N*RwrysM 4n va Lug-Drill deburr hole aM bolt Mru bets raK walls per able. le. Lug eto-S2 7/32- TORQUE VALUE 5 R Its,. • Tomue W.d,EXI on wnd—r1 Sea ILSCO product datp sM1eet for more debita,Model N.G9L.4DBT • See wo0ucl data sheet forlwque value. NOTE:ISOLATE COPPER FROM ALUMINUM CONTACT i0 PREVENT CORROSION PROJECT NAME .;; SMSOLAR BONDING CONNECTION GROUND PATHS; 1s .;; SM SOLAR ENDCLAMP& FIRST MODULE •• MOUNT ;PAGE •• MOUNT ;PAGE Q - --------- -------- ------- -- -- - -- --- ----- --------- .r ii @eel f wYD�oO 0 pUQZ�Z p`Qi` r-NJi� °•aV © ,/ /may*r'' l�.t�/S' Z 0 N O BONDING MIDCLAMP ASSEMBLY BONDINGMIOCLAMPASSEMBLY BON DING RAIL SPLICE BAR RAILTOLFOOTw/BONDINGTBOLT INSTALL MODULE ENDCLAMPS'The EW,I..p is INSERT ENDCLAMP T-BOLT.Insert 1/4*tbcrinto ROTATE END CLAMP T-BOLT:Relate l-out No posh Z Q N Q O F.w• m w m mm,rter O R Ne T. w ppned a•an as:emmvw n a rbmt mated ail donv¢riry mac t� ican inm,atw a r Soh s.rt W W O Z �n��anmomomm,mmukmraeUe m�oyn°0a pm "era moece o.m. Range nut.and—he,rh¢washerietams the are angled inthe,or,-Pull- J f— d clamp stee top.Lhe n..bLYThi,mUeI111 �J Q Q the[lamp t,en'aln Uwlght for mpdUte installa[pn. End damps se poslu-1 en:ails 111.1 to the flat W ©- waif.. ,..rt.cem�.u.e entl momne andltstalled ahe,iM1e last end motlule =J O"°M a a"` E`'Qe E �� D cm /'® T6HEET NAME ';oEEND= SPEC SHEETS SHEET S ZE BONDIHG MK:RDINYERTER MOUNT RACK SYSTEM GROUND INSTALLFIRST MlR1ULE Install the fl R nd mcd POSITION INDICATOR SERRATED T 00LT.Verify me P05MON INDICATOR NON-SEWnDT--BOIT l Oma «ne n,.w..n.utl�oratmlA 0..wemtrn..mrx.aly 1e�w uleontdralsEngagemodulelramewhM1End iboltposition'ndcatorisperFendialar[othe Verify[beTbpllpostbnindicrtorisargledas ANSI B ,Ump&Verify that the posltlor.iroKat4r GTbolt al. Shown.FOR LSE WITH MILL FINISH RAIL ONLY a— © ,: h„„m,;,e ©w ro shell an angled m the correct positlan. 1 1"X 17" awxvA _•'� m�nu..�n ww.nrr.�.y u�.. TORQUE VALUE:1/I.—to lO R-Us.whM1 m ....mn.,.w�„r.- ,�.�. �_^+' "^'°' Ami Seiee SHEET NUMBER PV-15 CONTRACTOR INFORMATION NATIONWIDE SOUR PO BOX B]1959 VANCOWER,WA 90801 ■■ S MSOLAR BONDING MIDCLAMP : 4 STRUCTUNEIBUIL DING NATOS'TBBCW ELECTRIC AL:NATIOS'TBBTW UBI:SWTBOS95 ELECTRICAL SUPERVISOR:COLE BABBITT Em 0LICENSE ceeeee00l@mYe ABe ilomAEeOwlar com won ; MOUNT MUM wTIO rlwmc ; PAGE Nat(onswoideg► ------------ ------ ---------------------------------------------------------------- NATIONWIDE SOLAR A E.SUITE VANCOWERWA9888]B PLOW: mB'/e'Bleeceomv,tleaoler.wm VERSION INSTALL MIDCLAMPS:Midclamp is supplied as INSERT MIDCLAMPASSEMBLY:Insert 1/4"T-Bolt MIDCLAMP:Rotate midclamp assembly and slide DESCRIPTION I DATE REV an assembly with a T-bolt for module installation, into top slot of rail until clamp is against module frame.Do not tighten NI AL RELEASE 09-11 1124 UR Clamp assemblies may be positioned in rail near nut until next module is in position.Ensure bolt is point of use prior to module placement. perpendicular to rail. PROJECT NAME a� rn 0D o� -1i Z o Z W�DO (Y,)2O NU p Q Z Z Z 3:Oo0 t'' I ��ZQNQ LuwO2Z� f— i Jew~< 1 U F PLACE ADJACENT MODULE AGAINST CLAMPS: POSITION INDICATOR-SERRATED T BOLT: Modules must be tight against clamps with no gaps. Verify the T-bolt position indicator is perpendicular Tighten nut to required torque. to the rail. SHEET NAME SPEC SHEETS TORQUE VALUE:11 ft-lbs.No anti-seize. SHEET SIZE ANSI B 11"X 17" SHEET NUMBER PV-16 CONTRACTOR INFORMATION NATIONWIDE SOLAR PO BOX 621969 vANCOWER,WA 98662 STRUCNREIBUILDING',NATICS•766CW ELECTRICAL:NATIOS•786TW Descriptive Report UBI:b)68fi9fi EIECTIgILAL SUPERVISOB' BABBITT S A 4CENSE AOBABBICW BB02 �GROUP'��V Emeq:parmndept�mvnalionwidesobr.wm NaflonvLAR�eyl► so MASTER CONTRACT: 0000266909 REPORT: 70131735 PROJECT: 80219156 NATIONWIDE SOLAR BA07 NE 11 TTH AVE.SUr B IN VANCOWER,WA 96662 PHONE:(Boo)w8B 8992 Emaq:gatwler�mynellomvlde,oler.com -- - - _ MAOUNTCOMPATIBLE MODULES : ■ Edltlun 'leaned OR Project Location Prepared Authorised By �� 1 1 Edition 1 Se tember20,2017 70131735 Irvine MichaelHoffnagle Michael Hoffnagle son, ERTIfICATI R Edition 31 March 26,2024 80198760 USA Irvine Michael HofTna le Michael Hoffnagle I is i, i PACE Edition32 Jul 10.2024 80215253 USAIrvine Michael Hoffna a Michaellloffna le El----...ecMu-l-6antlina at-tl-Waundlna THbst Mo. auln`-..-.-- ----------------------------------------------------------------------------------•---------------------- _-. - —_ - Edition 1, August 09,2024 80219156 'USA Irvine Jos hGarcia Jw9hGarcia The 110 ew.w•h ONalbantiva d camenam ,k,1bat1h""a tNwe aMt trr aaen«A,xad ane rwne t,:al rkanyb P.R,Le weh tna sOLARa Uw YRam. µ eM,.IWf.tlfN,.tg06.Df0a.(Rr.0 vSl N.mb»BIIVSUN. 11- oe,swn VERSION w sNc.mlat rcc�W.c.sa�n vxNse-.aaR«.ec Certificate of Compliance+Supplement-Page I to 14 ° .)6�uiiaui DESCRIPTION DATE . REv rsN Nt .m Description and Tests-Page 1 to 47 El INITIAL RELEASE Oa•1Mt0f° UR a, tcsw AQI Installation Manual SM-Pages I to 51 - Att2 Schematics SM/ULA-Pages I to 134 Ana Installation Manual ULA-Pages I to 29 N. N.. -® Att4 RMS_Installation Guide-1 to 23 ""`"" PROJECT NAME AttSRMDT Installation Guide-Ito24 Dwa, An6 KM series schematics-Ito 40 ..urran.:ara•a•c ` At 7 GIFT Installation Guide-Pages I l0 42 'rw...vate 1 ^" rw...Nruaa m1 a AttR GFT HD Rail Installation-Pages 1 Att9 GIFT Schematics-Pages I to 69 Q Att10 NXT UMOUNT Installation Manual-Pages 1 to 40 -- °AEO°""'01i2''"''0f - N d Att11 Schematics NXT UMOUNT-Pages 1 to 147 ;-;M�'w:�;�. �1 O o rn Att12 SM Ascender 2P Elevated Installation Manual-Pages I to 37 r• �'"'°MiOP'« Z o Al:2 SM Ascender 2P NON Elevated Installation Manual-Pages I to 36 „roN,s a,yr,e UJ Z lt)00 0)0 An 14 SM Ascender I P Non Elevated Installation Manual-Pages I to 33 U co U N U Atll5 SM Ascender 1P Elevated Installation Manual-Pages I to 36 0—Q Z O Z Att16 Schematics SM Ascender-Pages I to 52 Z U�8 N 0 Att17 SM Ascender Flush Mount Installation Manual-Pages I to 28 fA Att I S S•5 uhematics and installation-Pa es I to 19 •unless innerw�se namd.mo maame,u,tee ahwe mnDae al wattage,and,Peaigc madel,vdlhin trot serve,Wnahle wa"a9n era IePre,enled a,•.,, g Z Q N Q B .Items In Parentness are those that may or may mt ee Pesent in a campattle module',model IO Att19SM NXT-Tilt Leg Install Addendum_—Pages Ito13 •SI hetYhe,weanm»ormareRem,-t—the,end»rafmouitem:maynameonematI,P—Itmamodmesm tIn Jti d— •The frame Profile must gat 1,—any feature that mi"ht t,rfe w,h the hooding devlces,M1a1 am Integrated In'.-'.oino system •Use whM1amaeimum oNer currant protection device OCPDof 30A Ql W Q.T. Report pages reissued:All •Luo-e modals,al ha oRa m.emeNaael,.,AnR,yR.a rmngbaleep ilape arts lo.,mpe avpu,xlon,.xe wge eo d'=_ Q Attachments Added/Revised:All I-Updated,51 pages CO Att3-Updated,29 pages This report shall not he reproduced,except in full,without the approval of CSA Group. SHEET NAME Irvine 34 Bunsen,Irvine,CA 92618 SPEC SHEETS Telephone:949-733-4300 Fax:949-733-4320 SHEET SIZE 04 139N Rcv u'_0`_4 CSA GmuP.An rlghrs rexrrcd. ANSI B 11"X 17" SHEET NUMBER PV-17 CONTRACTOR INFORMATION PUCrIONWIDE SOUR PO Box vim VANCOUVER,WA 9(av STR'MRE W 11-DING:I—OS'1BBCW ELECTRICAL NATIOS'78— UBIBDiTBBa95 ELECTRICAL SUPERVISOR'.COLE BABBITT CSA LICENSE ADBABBICW1a603 Emal:pxmAaeDl�,mynalionwiaeaDler.ram Shk CSA GROUP GROUP Cer90e•te:70131735 CIP \7aster C'ootraeC 2669N NQtiornvfde OO► sou Pnvject:90219156 — Date Issued:2024-09-0R • steel a al rni unit mid chnps and Airman n end ebapa.The nledlul s ere horded to the making system with the stemless-steel hooding, rr+......r.�+-...... Certificate of Compliance nndcbra"with Piercing Ponu.The system n E uxkd with lO AWG c.Me,wits to borxfng/pwvng k�.Fie ratings of Class A x uh WNATIDNWIDE SOLAR Tv1c I,Z,3(wdr nd;tulE f mc),4(with trun),5(wig trig),10(wkh mctaAk frame),19,2Z 25,29,or 30 f r steep.akpc.Cass A with e4B]NE„]ins AVE.sutrE B VANCOWER,W .12 Type 1.2,29 a 30 fa k"v sl pe.Tested at S"nlenti.1 kMP which alkrvs nsmll Lion al any stand-off he*ht, PNONE:(eoo)9aea99z C'ertitkate: 70131735 llastcr Contact 266909 E,nal:gelaDlar@mynanomvioesaar.mn The grotadng of the synem n intcn ed to conic ly with the latest edition ofthc National Electrical Code,to whak NI:C 250 @ 690.Lnal Pajeet: 80219156 Date ksniud: 2024-08-08 codes corrplumce is reMrkcd,in ahlhinnational to codes.Al groutdng/Ixaaing cotmectkxs am to he IMLed in Bceorderace with the Instalkuin Manwl and the setting,used dining the cenifCatin testing feu the current eduina of the Proles,repooL Issued to: Uruac 1411 Bna.&-y NE: SobrMou t Tik Legs is a varbtix,of the SohrMoutt system that tnilinx snucmral surdli f attachments to achieve a range of track tih NlNrgnc rque,New M-kir 87102 angles.The SobrMa,m Tik Logs nstal tin ium,etidLc am captured it an Insullatin Addendum that coats both the SokarMotart Tilt United States Leg sy,,e.,a,d the NXf Tat Legs system.SolarMrnm Tl Leg has mechanical kind rating,independent of the SobrMn,m and NXf LIMOUNT mechanical kind ratings. Attention:Rob D'Ar task, VERSION The system may c,rpby optic-m/nrkno-ktvenen and used for groording when inaal'cd Per nstalbtnn i—actins. DESCWI'T)ON DATE REV The products listed below are eligible to bear the CSA MarA shown with adjacent INITIAL RELEASE Latest SnhrMoomt Insult Manual re,dsion:PUB?(124JULI2 indicators'C'atul'U.S'for Canada and US or with adjacent indicator'LlY far US only or withoul either indicator for Canada only. Latest&,brMour,NXT TlA Leg hnstablin Addendum re-Kin:PUB2024JAN Ix PROJECT NAME SBbrMotaa UL 2703 Mcchaninl Load ratings: JrcL•ph G.,iu Module Am Io 2a.-"11 Isstrd by: aP -" I Joseph Garen DDwm.. ago[oad(Rvn') Il)_.5 n afn 1a1 Ik'tV1 501 d k,pc fual(k,r, 11,13 C ®US Q do O ownw �co 4Zoz Module.Ara,up n,2T.1 Lu Z to Z)pOj 0 Dard Dccian Loved Ilhdl') 33.9 o" N U �IM LJrxard lk-p L,ud la,Il'I tJ.9 Q Q Z t 7 0 ER Ckein 5313 02 POW SUPPLIES-PHOTOVOLTAICS--PV Rackkp tk"'"-sk,Pe.u,ad 1m Ii'1 16.3 Z U O o fin Ckns 5313 82 POWER SLTPPf.IFS-PI IOTOVOI.TAICS-PV Rackix,ant ckulpktg.V+'I ITN-Ccnih'r11.us Slanlanis -- - - 52 Z Q N Q Mo,duk-Ara,,N,1u 29.49 eq B Lit w O 2 Z J SOIARMOLTT Elmhto-Rnof is an cxtrvdcd slununum ail P\'ackillg s3lcm Thal is ilutallcd Iulallcl to t1r roof in Ibwnwand Iksien Imd IIblBa) 31.19 W J}d hnralscape or pomait orientations. tpu and u.igntad(NB') 31.18 =JQQ flume IrnJe,\rras is x gauml mm�n s)slrm,niry;tin Snla,'1Uowtl(.SJ17 pWtfoal fur tla•Inmkry;and gmwdlilq;of Pk' I m Skj.L-d(a'dk') 9.8 V)F nadhid— SobrMo nt Test Loads: Modekq I SM,I]UIMMbdc.tren uP t„'-,.-=y n SHEET NAME llh11=1 71120 tfiwara L,:d(It�n�) 76.07 SPEC SHEETS SoYrMo•nl IA,a-o sW,,,I.—[(11,11", 24 2 SHEET SIZE The system Bted s designed to Provide Ixadreg,amditg and rrcchunical stahlky for photook is modules.The system is secu and no the, hk,duk Aru,1,,,,''-7.I2,n ANSI B ntof wih the tlFna raanponents thnngh the—lii g tmlernl to building strnau re.61uduks hit secured to the racking system with stai,k„ 11"X 17" QE611W 0.v 201a 30 02024CSA(hw All nr/aanmmwl Ppl pf>•13yt 14+'bn4A0-M, c\IZA LS1CFdry A9 n(hu Rcn„1 I'2 SHEET NUMBER PV-18 CONTRACTOR INFORMATION NAM NWIDE BOLAR PO Box 921959 VANCOWER,wA 96(a2 tmaUCTUREIBUILDING:NATIOS'7915CW ELECTRICAL:NATIOS-78- UBI:"'78""' ELECTRICAL SUPERVISOR:COLEBANITT LICENSE.ADBABBICw789O2 E119:Ixmnitdept@.y,at-,deoolar.mm Engineering Alliance,Inc Engineering Alliance,Inc Nationwide. https://www.eng a11ionce.com hftps.11w .eng-itiance.com SOLAR} 11-December-2023 Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape-PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is ....,�....�_..,.4�._..._.. mounted On the long side. NATIONWIDE SOLAR Unirac 6107 NE 117TH AVE.SURE B Portrait-PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel Is 1411 Broadway Blvd.NE VANLOWER,WA 99982 Albuquerque,NM 87101 mounted on the short side. Email gp-1xr@r,y t1,n,19 Wanton Tel:505 242 6411 Components and Cladding Roof Zones: Attn.:Engineering Department The Components and Cladding Roof Zones shall be determined based on ASCE/SEI 7-10&7-16Component and Cladding design. Subject:Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. The Unirac SOLARMOUNT Flush-to-Roof is an extruded aluminum rail system that is engineered to hold most framed solar 2. Risk Category II per ASCE 7-16. modules to a roof structure and installed parallel to the roof. 3. Topographic factor,kzt Is 1.0. 4. Array Edge Factor YE=1.5 We have reviewed the SOLARMOUNT system,a proprietary mounting system constructed from modular parts which are S. Average parapet height is 0.0 it. VERSION intended for rooftop installation of solar photovoltaic(PV)panels;and have reviewed the U-Builder 2.0 Online tool.This U- 6. Wind speeds are LRFD values. DESCMMON DATE Rev Builder 2.0 software includes analysis for the SOLARMOUNT rails(SM LIGHT rail,SM STANDARD rail,and SM HEAVY DUTY rail) 7. Attachment spacing(s)apply to a seismic design category E or less. INITIAL RELEASE 1194"M UR with Standard,Universal AF,and Pro Series hardware.All information,data,and analysis are in compliance with the following codes,city ordinances,and typical specifications: Design Responsibility: The U-Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where Codes: 1. 2015-2021 Washington State Building Code required by the authority having jurisdiction.In all cases,this U-Builder 2.0 software should be used under the direction of a 2. ASCE/SEI 7-10&7-16 Minimum Design Loads for Buildings and Other Structures. design professional with suffident structural engineering knowledge and experience to be able to: PROJECT NAME 3. International Building Code,2015-2021 Edition w/Provisions from SEAOC PV-2 2017. 4. International Residential Code,2015-2021 Edition w/Provisions from SEAOC PV-2 2017. •Evaluate whether the U-Builder 2.0 Software is applicable to the project,and 5. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels, •Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. November 1,2012 by ICC-E5. 0 6. Aluminum Design Manual,2015&2020 Edition. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush,when installed according to the U-Builder 2.0 engineering Q= a report and the manufacturer specifications are in compliance with the above codes and loading criteria. N Following are typical specifications to meet the above code requirements: CT= This certification excludes evaluation of the following components: of O z Design Criteria: Ground Snow Load=0-100(psf) 1)The structure to support the loads imposed on the building by the array;including,but not limited to:strength and LU?L0=0 0 OD Basic Wind Speed=85-190(mph) deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects of snow, V N U Roof Mean Height=0-60(ft) accumulation on the structure. _-Q Z e-Z Roof Pitch=0-45(degrees) >0 O0 2)The attachment of the SM SOLARMOUNT Rails to the existing structure. Z > Exposure Category=B,C&D 3)The capacity of the solar module frame to resist the loads. 0 Z Co N Q Attachment: Shingle Roof: Q L-Foot,Flashkit Pro,Flashloc Comp,Flashloc Duo,Flashkit Pro SB This requires additional knowledge of the building and is outside the scope of the certification of this racking system. J ti d Metal Roof: O I j Q 2 Standing Seam attachments,PM-9000S,PM Adjust Slotted Please feel free to call or email for any questions or clarifications. OP�'I-AF1 =J Q Tile Roofs: r �OF W'S ,4',?o fA Solar Hooks,Tile Replacement Attachment Spacing: Per U-guilder 2.0 Engineering report. Prepared By: 'N C, Engineering Alliance,Inc - ' Cantilever: The maximum cantilever length is L/3,where"L"is the span noted in the U-Builder 2.0 online Sugar Land,TX 9 51947.0 tool. G75T SHEET NAME Clearance: 2"to 10"clear from top of roof to top of PV panel Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation ,� , SPEC SHEETS 11-DEC-2023 EXP.:15-DEC-2025 SHEET SIZE 4603 April Meadow Way,Sugar Land,TX 77479.Ph:932 8654757,Email:sahmad@eng-alliance.com 4603 April Meadow Way,Sugar Land,TX77479.Ph:832 8654757,Email sahmad@eng-alliance.com ANSI B 11"X 17" SHEET NUMBER PV-19 OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- - Project Information Property Owner Name: Leland Dyer Project Address: 497 E McMickin Rd Parcel# 220012490090 City:Shelton State:WA ZIP:98584 Day Phone: (775)299-8467 Contractor Name Nationwide Solar, Fabian Angobung Contractor License#: NATIOS*786CW Contractor Day Phone: permitdept@mynationwidesolar.com (800) 908-8992 PV system description (N) 32 VSUN SOLAR VSUN370-120BMH (370W) MODULES (include manufacturer (N) 1 SOLAREDGE HOME WAVE SE1000OH-US STRING-INVERTER and model#of PV (N) 32 SOLAREDGE S440 POWER OPTIMIZERS modules and inverters): ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that X ❑ is code compliant to setbacks and height, or code allows expansion of nonconformity for solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, ❑ metal roofing, lightweight masonry, or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] 15a ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to X❑ ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended by WA State. [IRC M2302.2] 7. The PV system is designed for the wind speed of the local area,and will be installed per ❑ the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] Gd ❑ 9. Total dead load of modules,supports, mountings, raceways and all other appurtenances weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] X❑ ❑ Enter total dead load of system (Ibs/ft2): 2.71 PSF 10. To address uplift, modules are mounted no higher than it"above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] I 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty(50) pounds. X❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for X❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, X C1 Cl rodents, and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. X C [IRC M2302.2.31 Comments: Meets Prescriptive "Installation" Requirements If you answered yes to all of the above questions, the project qualifies for the over-the- counter permitting process. © Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] Mason County N* As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: 4Atr6U Date:9/26/24 Applicant Name (Please Print): Fabian Angobung --------TO BE COMPLETED BY CITY STAFF------ Qualifiesfor OTC Building Permit? ❑Yes :]No Permit Application#: Staff Initials Date: