Loading...
HomeMy WebLinkAboutBLD2019-00623 Cancelled ATF Patio, Garage, Bedrooms, Bath - BLD Inspections - 11/6/2024 615 W.Alder St.Bldg 8,SHELTON,WA 98584 MASON COUNTY COMMUNITY SERVICES SHELTON: 360-427-9670,EXT 352 BELFAIR: 360-275-4467,EXT 352 Building,Planning,bnvironmenul Health,Community Ifealth ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2019-00623 Date Issued 01/11/2021 Issued B Project After the fact covered porches&new attached garage with 2 bedrooms and bath on uppe*floor. Site Address 401 W Bourgault Rd W Applicant ARTHUR L TOZIER JR Contractor Contractor Phone Primary Code UPC IBC, IRC, IFC, IEC,IMC,& Type Permit Type ADDITION OR REMODEL- Occupancy RESIDENTIAL -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/ Runners Final Other Materials Testing & Consulting, Inc. Geotechnical Engineering • Social Insoection • Materials Testing • Environmental Consulting Client: Reeve Sherwood Consulting,LLC. Date: September 29,2020 Address: 12680 W Shelton Matlock Rd. Project: Art Tozier Garage Shelton,WA 98584 Project#: 20S213 Attn: Randy Reeves Sample#: B20-1400 Date Revised: Date Sampled: September 24,2020 As requested MTC,Inc.has performed the following test(s)on the sample referenced above.The testing was performed in accordance with current applicable AASHTO or ASTM standards as indicated below.The results obtained in our laboratory were as follows below or on the attached pages: Test(s)Performed: Test Results Test(s)Performed: Test Results • Sieve Analysis See Report Sulfate Soundness • Proctor i 143.3 pcf P.7.2% Bulk Density&Voids Sand Equivalent WSDOT Degradation Fracture Count Moisture Content Specific Gravity,Coarse Specific Gravity,Fine Hydrometer Analysis Atterb erg Limits Asphalt Extraction/Gradation Rice Densitc If you have any questions concerning the test results,the procedures used,or if we can be of any further assistance please call on us at the number below. f Respectfully Submitted, Meghan Blodgett-Carrillo WABO Supervising Laboratory Technician Corporate—777 Chrysler Drive Burlington,WA 98233 • Phone(360)755-1990 • Fax(360)755-1980 Regional Offices: Olympia—360.534.9777 Bellingham--360.647.6111 Silverdale—360.698.6787 Tukwila—206.241.1974 Visit our website:www.mtc-inc.net r' Materials Testing & Consulting, Inc. Geotechnical Engineering • Special Inspection • Materials Testing • Environmental Consulting Sieve Report Project:Art Tozier Garage Date Received:25-Sep-20 ASTM D-2487 Unified Soils Classification System Project#: 205213 Sampled By:Other GP,Poorly graded Gravel with Sand Client: Reeve Sherwood Consulting,LLC. Date Tested:28-Sep•20 Sample Color. Source:Oosite sampled by others Tested By:K Mendez dark-brown ACCREDITED Sam rlc#: B20-1400 •"" R� _ ASTM D-2216,ASTM D-2419,A.STM D-4318,ASTM D-5821 D[st=0.333 mm °tee Gravel=59.0% Coctl_of Curvature.C, 0 45 Specifications DIta1=0.566 mm %Sand=39.5% Coeff.of Uniformity,Cu=20.90 No Specs DpS,=0.784 mm %Silt&Clay=1.5% Fineness Modulus=5.61 Sample Meets Specs N/A 1)tbl=1.733 mm Liquid Limit=tits Plastic Limit=n/a Dt,a1=7.738 mm Plasticity Index=n/a Moisture%,as sampled=n/a DI"=11.839 mm Sand Equivalent=n/a Req'd Sand Equivalent= Dt,ol=40.224 mm Fracture%,1 Face=n/a Req d Fracture%,I Face= Dust Ratio= 12153 Fracture%,2+Faces=n/a Req'd Fracture 0%2+Faces= ASTM C-136 ASTMD-691I3 \ctu:d Interpolated - - Cunudalive Curnulative Grm S¢e Dtlrbulbn Sieve Site P--t Percent Specs Specs US Metric I'a Passin Maa Min ebb �:t+ _ ti a..�. . iaoa.._._..._.•. taaoa 12.00" 300.00 100 100.0% 0.0% 10.00" 250.00 100% 100.00/0 0.0'/0 •S 8.00" 200.00 100% 100.01% 0.0% 6.00" 150.00 100% 100.00/0 0.0°/" 4.00" 100.00 100% 100.01% 0.0% oa 3.00" 75.00 100% 100'/0 100.0% 0.0"/0 °E 2.50" 63.00 98% 100.0% 0.0% 2.00" 50.00 96% 96% 100.0% 0.0% raa 1.75" 45.00 93% 100.0% 0.0% 1.50" 37.50 88% 100.0°/" 0.0% 125" 31.50 84% 100.00/1 0.00/" 1.00" 25.00 80°/" 80"/0 100.0% 0.0% 3/4" 19.00 72% 72% 100.0% 0.00/" 5/9" 16.00 67% 100.0% 0.0"/" " 12" 12.50 61% 61% 100.01% 0.0% 3/8" 9.50 55% 55% 100.01% 0.0% o, 1/4" 6.30 46% 100.00/1 0.0% 94 4.75 41% 41% 100.0% 0.0% #8 2.36 35% 100.00/1 0.0"/" #10 2.00 34% 34% .00.00/ 0.0% #16 1.18 22% 100.0% 0.0% r>R #20 0.930 17"/" 17% 100.0% 0.0% #30 0.600 11% 100.0% 0.0% #40 0.425 7% 7% 100.0% 0.0% io. #50 0.300 4% 100.0% 0.0% #60 0.250 3% 3% 100.01% 0.0% #80 0.180 3% 100.0"/0 0.0% °R • omOM taa000 taaao t.aoo o.too onto #100 0.150 2% 2% 100.0% 0.0% #140 0.106 21% 100.0% 0.0"/ #170 0.090 2% 100.0% 0.0"/" 4200 0.075 1.5% 1.5% 100.0"/6 0.0% sp.e s". -•-Ma.sr.� --.-M,sue, --se.e s«„m a T,a.,rn s•.;=:es.tvvess --w ha a.row 1-.d winub iva.u,-1 pianro, 6r a"pn .1-,u -,M umr.o"ra�.�,�v"m "r.i�.,n,..d.,e�vu•."r wni�.n ..ram ..oKb. a..ate-.:ft. r d� ­de Comments: Reviewed by: ` Meghan Blodgett-Carrillo Corporate-777 Chrysler Drive • Burlington,WA 98233 • Phone(360)755-19" • Fax(360)755-1980 Regional Offices: Olympia-360.534.9777 Bellingham-360.647.6111 Silverdale-360.698.6787 Tukwila-206.241.1974 Visit our website:www.mtc-inc.net Materials Testing & Consulting, Inc. J51M Geotechnical Engineering • Special Inspection • Materials Testing • Environmental Consulting MATERIALS TESTING a CONSVL1lNG,ING. Proctor Report Project Art Tozier Garage Date Received:25-Sep-20 Unified Soils Classification System,ASTM D-2487 ASTM C-136 Project#:20S213 Sampled By:Other GP,Poorly graded Gravel with Sand Sieve Size Percent Specifications Client:Reeve Sherwood Consulting,LLC. Date Tested:28-Sep-20 Sample Color US mm Passing Max Min Source:Onsite sampled by others Tested By:IC Mendez dark-brown 12.00" 300.00 100.0% 0.0% Sample#:B20-1400 10.00" 250.00 100.0% 0.0% Sample Prepared: Moist:X Manual: 8.00" 200.00 100.0% 0.0 Dry: Mechanical:X 6.00. 150.00 100.0% 0.0% Test Standard: ASTM D698: AASHTO T 99: Method 4.00" 100.00 100.0% 0.0% ASTM D 1557:X AASHTO T 180; C 3.00" 75.00 100% 100.0% 0.0% Assumed Sp.Gr. Point Percent Dry Uncorrected Proctor Value 2.50" 63.00 100.0% 0.0% 2.90 Number Moisture Density Max.Dry Density Optimum Moist 2.00" 50.00 96% 100.0% 0.0% 1 .8% 1 .9 1325 Ibs/ft' 9.8% 1. " 45.00 100.0% 0.0% 8 2 .8% 13232.3 1.5050" 37 37.50 100.0% 0.0 3 10.8% 132.1 Value w/Oversize Correction Applied 1.25" 31.50 100.0% 0.0% 4 12.8% 130.2 Max.Dry Density Optimum Moist 1.00" 25.00 80% 100.0% 0.0% ACCREDITED 143.3 lbs/fe 7.2% 3/4" 19.00 72% 100.0% 0.0% 518" 16.00 100.0% 0.0 40 1/2" 12.50 61% 100.0% 0.0 4'0 Moisture Density Relationship 3/8" 9.50 55% 100.0% 0.0% "Q0 1/4" 6.30 100.0% 0.0% l+ao 160 #4 4.75 41% 100.0% 0.0% iio° #8 2.36 100.0% 0.0% iaJ4ao #10 2.00 34% 100.0% 0.0% ixo #16 1.18 100.0% 0.0% 110 #20 0.850 17% 100.0% 0.0% o izao #30 0.600 100.0% 0.0% lzco c lzao #40 0.425 7% 100.0% 0.0 uuo #50 0.300 100.0% 0.0% 1fl0 #60 0.250 3% 100.0% 0.0°o llco 110 #80 0.180 100.0% 0.0% lno Uo #100 0.150 2% 100.0% 0.0°o °% T% a% o% z•v. 11% 12% 13% 14% 15% 16% rl% lax WY M% n% 22% 23% 24% n% #140 0.106 100.0% 0.0% Percrnt Moiriure #170 0.090 100.0% 0.0% • o.. z.n M vo a cti. -c.<ra #200 0.075 1.5% 100.0% 0.0% ASTM D-4718,Miss Oversize Correction Values Spy: No Specs Meets Specs?N/A •Oversize Maeft o %Gravel:59.0% Cc:0.45 Dtjot:0.566 %Oversize Corrected Optimum %Sand:39.5% Cu:20.90 D(30): 1.733 Retained Density Moisture %Sik&Clay: 1.5% FM:5.61 D(60): 11.839 5% _134.3 9.3% 10% 136.2 8.9% LL:n/a PL:n/a PI:n/a r15% 138.1 8.4% 20% 140.0 7.9% Sand Equivalent:n/a Req'd Sand Equivalent: 25% 142.0 7.5% 30% 144.1 7.0% Fracture%,I Face:n/a Req'd Fracture%,I Face: cw r spm,a--..&Te .ialsmia,PS,19 9d Fracture%,2+Faces:n/a Re 'd Fracture°,o,2+Faces: .virmn,.pp>mi.ro,rnwn®nm,..am.la„i,lmeaa..iwm�pra«ixnm.emrz m.p.nee..a�.,war_..n..�.n....e,.,nmm�.,mrw.namna prol�or�imr..ma..mom no.r peu�.em or,ur".mu.«"w,.,.,.em.a.r<r,.Q..pfrau,gwrrcr�,..,•.:.�i„�� �,., „riven,pp-1 Comments: r � Reviewed by: Meghaa Blodgett-CamOo Corporate-777 Chrysler Drive Burlington,WA 98233 • Phone(360)755-1990 ° Fax(360)755-1980 Regional Offices: Olympia-360.534.9777 Bellingham-360.647.6111 Silverdale-360.698.6787 Tukwila-206.241.1974 Visit our website:www.mtc-inc.net MATERIALS TESTING A CONSULTING,INC. Art Tozier Garage - 20S213 - IPD-Soil Compaction: Report #D239714 CLIENT Reeve Sherwood Consulting, LLC. DATE 09/24/2020 PROJECT LOCATION 401 West Bourgault Rd Shelton WA PERMIT # Inspection Information: Inspection Date: Time Onsite: 0900 Weather 50's F rain � 09/24/2020 Conditions: Inspection Performed: {IPD-Soil Compaction Field Data: Work/Location: Center of area Gauge Standard MS: 11339 Equipment ID&Serial#: CPN MC-1,Ser.#MD00405572 Gauge Standard DS: 132220 Test Samples: Sample#:Description: Proctor Value(pcf):Optimum Moisture and Oversize Rock Correction: 1.B204400 GP,Poorly gr aded Gravel with Sand 143.3 OM= 7. % ORC=28% TEST METHOD o ASTM D-1557 /AASHTO T-180 In Place Density Test Results (ASTM D-6938): Test Mode/ Location of Test Elev. Wet Dry Dens. Moist% Sample %Comp. %Regd. # 1 8 center of area _ FG j 161.5 150.2 7.6 1 104.8 95 ❑ Native Soils Soils consistent with Proctor O Yes O No ® Imported Fills Soils found to be firm and stable;and to the best of our knowledge,meet O Yes O No compaction Contractor notified of results O Yes O No Remarks: i MTC Inspector arrived on site as requested to do in-place density testing of material on site.Material has been on site for approximately 10 years. Material is throughout the drive way and in the area where a proposed garage is going to be built. Inspector took one blind shot in the center of the area. Compaction rate is unknown at this time.Results will be updated once proctor analysis is complete. To the best of MTC inspector's knowledge,the above-described work was performed in general accordance with project specifications and approved plans. Images: Environmental•Geotechnical Engineering•Special Inspection•Non-Destructive Testing•Materials Testing Burlington IOlympialBellinghaml Silverdale ITukwila 360.755.1990 www.mtc-inc.net Art Tozier Garage-20S213,0912412020,#D239714,Page 1 of 2 4 MATERIALS TESTING&CONSULTING,INC. is r � .a, a W" B a -"WE"', " y & UPLOADED: 09/24/2020 14:04:54 UPLOADED: 09/24/2020 14:04:56 REPORTED BY:Ray Gean II REVIEWED BY:Robert McNamara,Project Manager Environmental•Geotechnical Engineering•Special Inspection•Non-Destructive Testing•Materials Testing Burl ingtonIOlympialBellinghamISiIverdaleITukwiIa 360.755.1990 www.mtc-inc.net Art Tozier Garage-20S213,0924/2020,*D239714,Page 2 of 2 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 CAC�LLED 360-427-9670 ext 352 www.co.mason.wa.us FNEWATTACHED 9-00623 ADDITION OR REMODEL- RESIDENTIAL DESCRIPTION: AFTER THE FACT COVERED PORCHES & ISSUED: 01/11/2021 GARAGE WITH 2 BEDROOMS AND BATH ON UPPER EXPIRES: 07/10/2021ESS: 401 W BOURGAULT RD W SHELTON PARCEL: 421153200100 APPLICANT: ARTHUR L TOZIER JR OWNER: ARTHUR L TOZIER JR PO BOX K PO BOX K SHELTON,WA 98584 SHELTON, WA98584 VALUATIONS: FEES: Paid Due U VB Utility, miscellaneous 1512.00 $72,273.60 State Fee-Residential $6.50 $0.00 R-3 VB Residential, one- 1512.00 $182,574.00 Change in Tenant - Minor EH $110.00 $0.00 and two-family Plan Review Covered Deck/Carport 280.00 $6,160.00 Mechanical Fees $37.00 $0.00 Mechanical Base Fee $30.00 $0.00 Plumbing Base Fee $25.00 $0.00 Planning Review Fee $240.00 $0.00 Plumbing Fees $77.00 $0.00 Building Permit Fee $2,084.88 $0.00 Plan Check Fee $1,355.17 $0.00 Total: $261,007.60 Totals : $3,965.55 $0.00 FIXTURES (sty Mechanical Fixtures City Plumbing Fixtures 1.0000 Repairs or Additions for the repair or, alteration 1.0000 Number of Water Heaters and or Vent of, or addition to each heating appliance, 2.0000 Number of Hose Bibs refrigeration unit, cooling unit, absorption unit of each heating, cooling absorption or evaporative 2.0000 Bathroom Sink cooling system, including installation of controls 2.0000 Number of Showers regulated by the Mechanical Code 2.0000 Number of Toilets 2.0000 Spot Vent Fan(s) Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 1 of 8 s Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 REQUIRED INSPECTIONS Setback Inspection Rough- Plumbing Inspection Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Inspection Insulation Inspection Shearwall Inspection BLD-Final Inspection Framing Inspection CONDITIONS Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * The foundation/footing must be placed on undisturbed, firm-native soil. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 2 of 8 Mason County ca Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septi c/dra infield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect Iabek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are available in '/4 or'/z sheets. The Mason County Permit Center will also have some available. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 3 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine -4C, Window (Max U- Factor):0.28, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-38, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. * All property lines shall be clearly identified at the time of foundation inspection. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360) 427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. * WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 4 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handier and all ducts are located within the heated space. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * This structure has NOT been reviewed or approved as an Accessory Dwelling Unit(ADU): A second dwelling unit detachec from an existing single-family dwelling for use as a completely independent or semi-independent unit with provisions for cooking, eating, sanitation and sleeping. ADUs are required to meet the requirements under Mason County Development Regulations 17.03.029. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 5 of 8 Mason County Mason County - Division of Community Development 2 �, 615 W. Alder St. Bldg.8 Jul Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 " A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet_A-2_designate wall(s) type —SW-8—with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. Epoxy grout required and specified on the approved building plans shall require a special inspection. The special inspector shall be the engineer of record or their authorized representative, a WABO Certified special inspector, or certified testing laboratory. In addition a Mason County Building Inspector may perform the inspection provided holes are prepared in accordance to manufacturer specifications that are available on-site during inspection. Special inspectors shall inspect the installation of grouted construction anchors as stated in the manufacturers specifications. An inspection report shall be prepared and submitted to the Mason County Building Department prior to the framing inspection of the project. OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 6 of 8 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 Those parts of heating systems that are altered or replaced shall comply with the current IECC/Washington State Energy Code, Section R503.1.2 When a space-conditioning system is altered by the installation or replacement of space conditioning equipment(including replacement of the air handler, outdoor condensing unit of a split system air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger), the duct system that is connected to the new or replacement space-conditioning equipment shall be tested as specified in WSU RS-33. The test results shall be provided to the homeowner AND the Mason County Building Department at the final inspection. The new and replaced heating equipment shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and IMC. New and replaced heating equipment shall be sized in accordance to WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing WSEC Section R403.3.2, all new ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems in accordance with International Mechanical Code or the International Residential Code. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 BM for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least land shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any new duct systems. All new ducts outside the building envelope (not including crawl spaces) must be insulated to a min. of R-8. Duct located within a concrete slab or in the ground shall be insulated to R-10 with insulation designed to be used below grade. DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to WSEC Section 403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * Attic Ventilation: IRC section R806 Enclosed attic and rafter area shall be supplied with cross-ventilation. The net area shall not be less than 1/150 of the area of the space to be ventilated. If 50% and not more than 80% of the ventilating area is provided from the upper portion of the space to be ventilated, then 1/300 is allowed. * The placement of buildings and structures on or adjacent to slopes steeper than one unit vertical in three units horizontal (33.3% slopes) shall conform to the International Residential Code Section R403.1.7 for descending or ascending slopes. Alternate setbacks may be approved subject to approval of the building official based upon the investigation and recommendations of a qualified engineer licensed in the State of Washington. Such an investigation shall include consideration of material, height of slope, slope gradient, load intensity, and erosion characteristics of slope material. * This garage portion of the structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 7 of 8 G FLe._� Mason County Mason County - Division of Community Development �v l 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00623 Applicant/ Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/ Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees) within 50ft, down gradient of Drainfield/ Reserve area. Environmental Health will require applicant apply for two party well approval prior to final of building permit. Well documents supplied with building application were for 331 W Bourgault Rd West. It assumed that 401 W Bourgault Rd West is sharing a well with 331 W Bourgault Rd. Two party well must be approved prior to final of building permit. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions f�n other s t /local law regulating construction or the performance of construction. Issued By: a Contractor or Authorized Agent: Date: Printed by:Kati Dooley on:01/11/2021 01:20 PM Page 8 of 8