HomeMy WebLinkAboutBLD2005-00562 Final Deck Replacement - BLD Permit / Conditions - 9/20/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2005-00562 OWNER: GARY GORDON RECEIVED: 4/5/2005 CONTRACTOR: LICENSE: EXP: ISSUED: 5/25/2005 SITE ADDRESS: 191 NE JOLLY ROGER LN BELFAIR EXPIRES: 11/25/2005 PARCEL NUMBER: 123315100066 LEGAL DESCRIPTION: BEARDS COVE DIV 8 LOT: 66 191 NE JOLLY ROGERS LN BELFAIR PROJECT DESCRIPTION: DIRECTIONS TO SITE: DECK REPLACEMENT NORTHSHORE (SOUTH) TO SANDHILL (RIGHT)TO LARSON BLVD (LEFT) TO LARSON LAKE (LEFT)T JOLLY ROGER (LEFT) General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: Type of Constr.: VB Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: 400 Type of Work: ACC Fire Dist.: 2 No.of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Seasonal Basement: Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: 12 Shoreline Desi SEPA?: No Model: Width: Ft. Rear: E .0 Ft. Slope: 10.0 Ft Side 1: W 12.0 Ft. 9.: Not Applicable Year: Serial No.: Side 2: E 9.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee KS 4/5/2005 $72.31 S12005 Planning Review Fee KS 4/5/2005 $155.00 S12005 Building State Fee ARC 4/14/2005 $4.50 S12005 Building Permit Fee ARC 4/14/2005 $111.25 S12005 Public Works Review AT 5/19/2005 $39.22 S12005 Total $382.28 BLD2005-00562 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2005-00562 CONDITIONS FOR BLD2005-00562 1) The internatioanl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such road� onne t with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X C vs7 6 3) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections.n X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or rr(emoval of approve documents will result in failure of required building inspections. ( 5) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 6) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Departm t prior to any further inspections being performed or approvals granted. X BLD2005-00562 Please refer to the following pages for conditions of this permit. 2 of 4 7) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). x (;,V G 8) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the internati al codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X t V" (, 9) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X C v1? rJ 10) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or r ulation, must be reviewed and approved by Mason County prior to construction. X c 11) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be�made prior to requesting additional inspections. X o?1 (:. 12) All property lines shall be clearly identified at the time of foundation inspection. X (� 13) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X l� ,'I (, 14) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have pre xen (!ction from being taken. No more than one extension may be granted. X 147 15) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and ashing. Install metal connectors approved for contact with the new types of pressure treated material. X 16) This permit does not release the unit for occupancy. Separate occupancy approval must be obtained prior to any occupancy by Mason County Building Department. The unit must remain posted prohibiting occupancy. This permit is for the deck construction only. X (2, "" C BLD2005-00562 Please referto the following pages for conditions of this permit. 3 of 4 17) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at X 800-647-09f person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 18) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X G. v*? 6 19) Prior to final approval, all upland areas disturbed or newly creed by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X �, �yl (, 20) Approved dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 1 Lid (' 21) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading,cuts, fills, etc.) required in the geotechnical report assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X �r This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure fo view and inspection. OWN ER OR AGENT: DATE: BLD2005-00562 Please refer to the following pages for conditions of this permit. 4 of 4 { co r o CONCRETE MECHANICAL MANUFACTURED HOME 0 cn Footings / Setbacks Date By Ribbons 0 Cn 0 Date By Gas Piping Date By N Foundation Walls Date B y Set-up Date By INSULATION Date By B G / Slab Insulation Floors Final Date By Date By Date By FRAMING Walls FIRE DEPT Date By Date By Date By PLUMBING Attic OTHER Groundwork Date B y Date By WALLBOARD NAILING D.W.V. Date By Date By FINAL INSPECTION Water Line Date By Date BY �x " x u : Date By CD cc cc a 0 r o o d 8 N O a 0 U) OO v N 0 hl 7171�Va, j, f h*h N �O J ''f 7 d 4c� 1 1k �71 � P s�,� k , ()b x , I �v x �v 'K HillFILE C/a THESE PLAT � MUST BE COPY ON THE jUei SITE FOR INSPECTION. .S • \ y _� Skh. 5 vs r WEE'I ALL C iJkitkTv1 WASHINCTON STATE COD S L ?7 ,9 Yk� T n"�' �J 1 � � zY- off , E.�ks:� — o f A°":' o MASON BUILDING INSPECTOR Alt � �2 '/ #N CHANCES SUBJECT TO APPROVAL �� $ CHANGES M— n 410S geq . SUBMIT CHANGES FOR APPROVAL \� XG TE , -� PRIOR TO PcR :fq"v11NG WORK 1� S ol 49. AA- G ^ e ; t—p or SP�u. �G�G r✓��� N Lanvf L SE c- Fo vct `5 P Ir-' r V_;';s ,v : Kau Deck, Stair, Landing and Cuarde4ajt Guard installed on all decks over 30"above grade. The greatest riser and the greatest stair E4"max1mum spacing Vertical Pickets at handrail tread shall not exceed the between pickesmallest by more than 3/8." - - Graspable handrail on all stairways with 4 or Stairways and more risers. I Plandings shall Not less than 34"and ! not be less than not more than 38" 36"in Gear vertically from nose of width. tread or walking surface. O -- - --- -— -- } Handrail ends shall C/S. be returned or shall r C k5 Te terminate in newel) posts or safety terminals. f 10"min. 1 Indicate joist size/spacing4 Ledger at wall: Stair nosing not less than Decks shall be positively anchored 314"but not more than for lateral&vertical Indicate beam size/ 1-1/4'on all solid risers bads. Toenails or unless tread depth is at v spacing.Provide positive nails subject to least 11." "' connection post to beam. H. withdrawal are not allowed.Decks shall --- �'= be self supporting if l connections cannot Indicate Indicate post size,spacing be verified during Indicate fasteners stringer size. I and base connector. inspection.R502.2 Space per decking material 4"x4"x16"masonry " � ��✓ � block with asphalt -- --- y Decks installed against manufactured A�2 homes must have beam support at this Provide 4"wood/earth clearance here, r �' location. 6"all other areas. Concrete footing 12"below grade when deck is 30'or �o ---- - - ---more above grade.See foundation info on reverse side. Typical Door with 3 Landings 0 0 - CONSTRUCTION MATERIALS 'f11&inate stairs Decay resistant woods with controls Landings are required on heartwood of redwood,cedar, located at top and each side of each black locust and pressure bottom of stairs. exterior door. preservatively treated wood Exception:A landing are all acceptable material for is not required with use in deck construction. Field 5 two or fewer risers. applied treatment is not an ,, E Iacceptable method. Fasteners °O for pressure preservative ko Landings shall not be treated woods shall be of hot- Zo 36"min more than 1-1/2" dipped galvanized steel, " landing lower Than the top of stainless steel,silicon bronze the threshold. or copper. Field cut ends, Min�ru Exception: notches and drilled holes of � --The landing shall pressure preservatively treated not be more than 7-3/4"lower wood shall be retreated in the than the threshold provided the field in accordance with AWPA 36"min Max.7 3/4"rise door does not swing over the landing. M4• landing Stairs&landings shall not be less than 36"wide. IRC R319&R320. 21 /` Handrail Details All stairways with 4 or more risers shall have at least one handrail. Such handrails shall be placed not less than 34" nor more than 38" above the nose of the treads and shall be continuous for the full length pf the flight. Handrail ends shall be retumed or terminate in the newel post or safety terminals. Handrails adja- cent to the wall shall have a space not less than 1 W between the wall and the handrail. Circular hand- rails shall have an outside diameter of at least 1 '/" and not more than 2." Handrails with a perimeter greater than 6 %" shall provide a graspable finger recess on both sides. Handrails shall not project more than 4 W on either side of the stairway. IRC R311 11/2 IN.MIN. 11/2 IN.MIN. 11/21N.MIN. 1114 IN.TO 2 IN. 11/4 IN.TO 21N. 11/21N.MIN. 11/2 IN.MIN. r�11/4 IN.TO 2 IN. 31/2 IN.MAX 11 /4 IN.TO 2 IN. NOT ACCEPTABLE NOTE: Other shapes may be acceptable If they provide an equivalent gripping surface. See third paragraph of Section 1003.3.3.6. 2s/8 IN. 25/8 IN. 25/8 IN. 21/ M. 2V4 IN. FOUNDATION SUPPORT SYSTEMS • Decks 30"or less above grade: Minimum 12"x12" manufactured pier. • Deck 30"to 5'0"above grade: Minimum 14"x14" manufactured pier set 12" below grade. • Decks greater than 5'0" above grade: Minimum 18"x18"x18" poured in place footing set 12" below grade. All deck posts shall have a positive post to footing and positive post to beam connection. Deck height is measured at the lowest point within 5'0" beyond the walking surface of the deck. y a ramp or a stairway in accordance to applicable C sections 311.6 or 311.5. Egress doors shall be 34. STAIR WIDTH:IRC Section R311.5.1 Stairways shall adily openable from the side from which egress is to be not be less than 36"in clear width at all points above the made without the use of a key or special knowledge or Handrails shall ohandrail height tproject more below the guired than 4hza on either side effordroom he t. of the stairway and the minimum clear width of the 31. LANDINGS:IRC R311.4.3,R311.5.4. There shall be a stairway at and below the handrail height,including treads floor or landing on each side of all doors. Exception: and landings,shall not be less than 31 %"where the Where a stairway of two or fewer risers is located on the handrail is installed on one side and 27"where handrails exterior side of a door, other than the required exit door, are installed on both sides. a landing is not required for the exterior side of the door. The floor or landing at the required exit door shall be not 35,than 1/2 STAIR TREADS &RISERS: IRC Section 311.5.3 The r more an 1 "lower than the top of the threshold of the maximum riser height shall be 7 V.The greatest riser Exception: The landing at an exterior doorway height within any flight of stairs shall not exceed the doorway. P g y smallest b more than 3/8". The minimum tread depth shall not be more than 7 /. below the top of the Y threshold,provided the door, other than an exterior storm shall be 10": The tread depth within any flight of stairs or screen door does not swing over the landing.The shall not exceed the smallest by more than 3/8". A nosing width of each landing shall have a minimum dimension of not less than%"but not more than 1 '/4"shall be provided not less than 36"measured in the direction of travel. The on stairways with solid risers.Open risers are permitted, walking surface of landings shall not have a slope greater provided that the opening does not permit the passage of a than 1/4"per foot. 4"diameter sphere.Exception:Nosing is not required where the tread depth is at least 11". The opening 32. GUARDS:IRC Section R312.IBC Section 1607.7.1 between adjacent treads is not limited on stairs with a Porches,balconies,or raised floor surfaces located more total rise of 30"or less. than 30" above grade or a floor below shall have guards not less than 36"in height. Open sides of stairs with a 36. STAIR HEADROOM CLEARANCE:IRC R311.5.2 totalise of more than 30"above the floor or grade below All parts of the stairway shall not be less than 6'8" shall have guards not less than 34"in ht.Measured measured vertically from the sloped plane adjoining the tread nosing or from the floor surface of the landing or vertically from the nosing of the treads. Open side of guards shall be designed such that a sphere 4"in diameter platform See exception for spiral stairways. cannot pass through. Handrail assemblies and guards i shall be able to resist a single concentrated load of 200 37. USABLE SPACE UNDER STAIILS:IRC Section lbs.,applied in any direction at any point along the top, R311.2.2 Enclosed accessible space under stairs shall and have attachment devices and supporting structure to have walls,under stair surface and any soffits protected on transfer this loading to appropriate structural elements of the enclosed side with 1/z"gypsum board i the building. Intermediate rails(all those except the handrail),balusters and panel fellers shall be designed to 38. ILLUMINATION: IRC Section R303.6,R311.5.7 All withstand a horizontally applied normal load of 50 lbs.On interior and exterior stairways shall be provided with a an area equal to 1 sq.ft.,including openings and space means to illuminate the stair including landings and between rails. treads. Interior stairways shall be provided with an .-A artificial light source located in the immediate vicinity of 33. RAILS:IRC SectionR311.5.6 R311.5.1 All the landing of the stairway, Exterior stairways shall be stairways with 4 or more risers shall have at least one .n O T provided with a light source located in the immediate handrail. Such handrails shall be placed not less than 34) 2 vicinity of the top of the landing of the stairway. Lighting nor more than 38"above the nosing of the treads. �� controls shall be accessible at the top and bottom of each J stairway without traversing any steps. Handrails for stairways shall be continuous for the full length of the flight,from a point directly above the top riser to a point directly above the lowest riser. Handrail � G 3-9. SPEC IAL STAIRWAYS:IRC.Section R31 L5.3.2, ends shall be returned or terminate in newel posts or n, R311.5.8.1. Circular stairways,spiral stairways,winders safety terminals. Handrails adjacent to the wall shall have iS �' d bulkhead enclosure stairwa shall co 1 ys mp y with all a space not less than 1 '/z"between the wall and the -Lqu�ments of stairways except: Winder treads shall handrail. Circular handrails shall have an outside e a minimum tread depth of 10"measured at a point diameter of at least 1 '/,"and not eater than 2". O =� 12"from the side where the treads are narrower. Winder Handrails with a perimeter greater than 6 1/,"shall provide --A ? �t.:�- treads shall have a minimum tread depth of 6"at any a graspable finger recess area on both sides. See handrail t z ' point, Spiral stairways are permitted,Provided the option in IRC Section 311.5.6.3 for additional handgrip m ' minimum width shall be 26 inches(660 mm)vith each tread requirements. Handrails shall not project more than 4 1/2" o N having a 7 Ih" minimum tread depth at 12" from the on either side of the stairway. See#34,stairway width for �S° .�y�nwer edge.All treads shall be identical,and the rise shall Z v 1 • x no more than 9 Ih".A minimum headroom of 6 feet 6 additional information. Refer to handout o p (Anches shall be provided.Unless demonstrated otherwise o �v r� 3�� A 1 MAtom 00j.,\j1Y VCV ROME`% UL SITE FLA 4 R n1 liRl_ T 014 SI T E F V S UU Ei, To Ai P V�� it loll v r - TOPOGRAPHY PROFILE: Direction: Scale: Approval: for office use Building Permit number: Building: Owner/Applicant: Date of Planning: Parcel Number: application: Env. Health: PyoN srArFo� MASON COUNTY 4 h1 C DEPARTMENT OF COMMUNITY DEVELOPMENT O ° S N y= Planning Division o Y n P O Box 279, Shelton,WA 98584 (360)427-9670 1864 NOTIFICATION OF INCOMPLETE APPLICATION April 28, 2005 GARY M GORDON 2916 BUCKLIN HILL RD #254 SILVERDALE WA 98383 Parcel No.: 123315100066 Project Description: DECK REPLACEMENT Dear Applicant: You have submitted a permit application (case no. BLD2005-00562) for proposed construction or development in the county. Upon review of your application, I have determined that the contents of the application are incomplete or do not provide enough detail for review. Therefore, review of your application will not proceed until the necessary information is provided (see the comment section of this letter for details.) Once the information is submitted and the application is complete, I will continue to process your application accordingly. If the additional information is not provided to the County within 180 days of this request, the application shall expire and no further action on the proposed development shall take place. Please contact me at (360) 427-9670, ext. 294 if you have questions. Sincerely, Charles Mead McCoy III Land Use Planner Mason County Planning Department 4/28/2005 1 of 2 BLD2005-00562 NOTIFICATION OF INCOMPLETE APPLICATION 4/28/2005 Case No.: BLD2005-00562 Comments: Due to slopes immediately adjacent to the project a Geological Assessment will need to be done to address slope stability and the other requirements of the enclosed landslide hazard chapter 17.01.100 section E. 4. The report must state that the hazards of the landslide area can be overcome in such a manner as to prevent harm to property and public health and safety, and must also assure the project will cause no significant environmental impact. See Mason County Code 17.01.100, E7. Please review your Geological Assessment prior to submission to ensure that it contains the information required in section E. 4. of the enclosed ordinance. Missing information will result in further delays in the review process. If any grading / excavation is proposed in or near slopes a grading plan will be needed to show any proposed topographical changes, cuts, retaining walls etc. 4/28/2005 2 of 2 BLD2005-00562 06&t i R�ri Department of Labor&Industries f�jcsLi2 '/L MANUFACTURED/MOBILE HOME Factory Assembled Structures Section ,�• ALTERATION PERMIT INSTRUCTIONS: 1. Complete all spaces,including the signature box(marked with an X). Do not MH complete Invoice# 2. Draw a map on reverse side of WHITE copy only. a r shaded - 3. Forward completed permit and fees to the nearest L&I office. See list on reverse. areas Insignia#. 4. Contact and schedule the Inspection(s)with the same L&I office per the checklist ! f iri Owner /`last name first name Day time phone- *�^ I `ate r _ �.!P� ;;1!* ............................. ,1 1. .. .......... .......................4 er�Q.1J:.f...1 Il ')"� `Cy J I.... ............................... ................................................... .......... Address / City State ZIP led Installer/Contractor/Dealer Phone Contractor's registration number ( ) Address City S 2 I0 +4 Serial Numbers) E HUD Number(s) 4 Place fee amount in proper box Place fee amount in proper box , l' Mechanical Electrical - �J. Heat Pump l Air Conditioning Heat pump /. `46" Furnace Installation (gas or electric) Air Conditioner O Gas Piping Furnace Installation (gas or electric) �� Wood Stove---- Serial o. Wood Stove(if applicable) Pellet Stove ---- Serial Pellet Stove(if applicable) Gas Room Heater Gas Room Heater Gas Decorative Appliance Gas Decorative Appliance(if applicable) Range: changing from electric to gas Range: changing from gas to electric Gas Water Heater replacement Electric Water Heater replacement Water Heater:changing from electric to gas Electric Water Heater replacing Gas Water Heater Plumbing Each added or modified circuit Fire sprinkler system (also requires a plan review) Hot Tub or Spa(power from home electrical panel) Each added fixture Replace main electrical panel Replacement of water piping system Low Voltage Fire/Intrusion Alarm Fire Safety Structural Inspection as part of a mechanical installation (cut truss/floor joist,sheet rocking) Miscellaneous Reroofs(may require a plan review) 4�_ lan review Changes to home when additions bear loads on home pereinspection- -- - Original Permit the design of a professional (also requires a plan review) sibnia Other structural changes(may require a plan review) ther Fire Safety Note: This permit expires one year after date of purchase. (Non-refundable) Work is completed at this time. An inspection is requested. Work is NOT completed at this time,I will call when ready. Make check payable to: Dept.of L i Ind . Signature of applicant or authorylefr resentative FEES DUE X Request approved or Request denied because of specific violations of Washington rules and regulations.' o Violations must be corrected and retnspection requested within 20 days of the notice or violation date Failure to comply'' a� may result in penalties per chapter 43.22 RCW. All violations noted are shown on an "Alteration/Factory Permit- c Continuation Form". r; Included are forms required which must be completed and fees submitted before reinspection. Date Area office Inspector 'Dotal pages F622-036-000 mfgd/mobile home alteration permit 11-02 White-Olympia Canary-Inspector Green-Contractor Pink-Purchaser Goldenrod-Purchaser MASON COUNTY PERMIT NO. d��— BUILDING PERMIT APPLICATION 426 W. Cedar • P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner(2APY 41. CoODaAl Company Name Mailing Address -IS [( Mailing Address City C/C tate(..1,4 Zip Code 94 121 City State Zip Code Phoner3L.)-2Gb•7459 Other Phf?6u Phone Other Ph. Lien/Title Holder Contractor Reg.# Exp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic existing Septic Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No. J — 77 V7 F Fire Distric Legal Description Site Address (Please include street name, street number and city) o L7 Directions to site Nu,OtN SNaRLl uurr4 ro SA.yoaa c ( oltr)7. 2.4 a wz lC✓0 a& V 1 O [ Rr Will timber be cut and sold in parcel preparation?Yes/No Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ iI Work - 3LI( = C Xi r/</6 1 T i =C Use of Building Describe o �� / C S yc�U SQ �� ie No.of Bedrooms No.of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq.ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No.of Bedrooms No.of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/No Installer Name Certification No. AD OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. dent of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare tl��t1 entitled ive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessar ao If rmission is required from any easement holder or any other party in interest regarding this application or the work proposed in placation,I .Wa ained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,r rE*n a�the-inYbrmation provided is accurate and grants employees of Mason County access to the above described property and structure for review PROOF OF CO ,U TION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date: Ow r/Owner resentative/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Awl Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee 7 Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee IVO 01VX_, Pre-Paid at Submittal Valuation $ & ® . ' TOTAL FEES MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Processing/Inspections/Addressing Mason County Bldg.III 426 W.Cedar P.O.Box 186 Shelton,WA 98584 (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 September 14,2004 NOTICE OF MASON COUNTY CODE VIOLATION One Up Inc. Trustee PO Box 64700 Tacoma, WA 98464-0700 The receipt of this notice shall constitute service regarding notification of violations of the Mason County Code, Title 14, Building and Construction. The violation(s)are occurring at the following property: Enforcement Case File No.: ENF2004-00393 Parcel No: 12331-51-00066 Site Address: 191 NE Jolly Rogers Ln., Belfair ❑ The Mason County Building Department investigated on 09/03/04 a complaint regarding a Dangerous Building at the above location. The inspector noted that the complaint appeared valid and posted the building with a Do Not Occupy and Dangerous Building Notice4. According to the Mason County Assessor records,parties named above hold legal interest in the parcel and are therefore subject to enforcement action for failure to comply. In order to bring your site into compliance you must: 1)Immediately upon receipt of this notice, secure the building and structures against entry. Apply for and obtain the required permits from Washington State Department of Labor and Industries and Mason County to remodel/repair the mobile home unit and the attached deck. Please make the necessary arrangements to submit for the required building permits prior to October 14,2004. If the permit is not received by October 14,2004,we will pursue additional enforcement action against you, including but not limited to civil infractions, liens against the property through the Mason County Hearings Examiner process and/or criminal prosecution as allowed under Title 14 and Title 15 of the Mason County Code. In the event that you feel you have received this notice in error or that the facts are inaccurate, I strongly encourage you to contact me at(360)427-9670 ext 726 to discuss your concerns immediately. If you have removed the illegal structure,please contact me so that a compliance inspection can be done to close the enforcement case against you. Sincerely, Larry D. Kelly Building Inspector/Code Enforcement Cc:Property File e , -16 h 191 Jolly Roger ENF2004-00393 x r� � Y a� 7/17/2008 Case Activity Listing 1:43:05PM >, Case#: ENF2004-00393 i� Assigned Done Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By Activity Description 9/3/2004 None DONE TFR 9/14/2004 TLG ENFB002 Site Invest 9/3/2004 Rotten decks posted do not occupy and dangerous building 9/7/2004 None KLW 9/7/2004 KLW ENFA010 Complaint Received ENFA500 Photos attached.See Documents 9/7/2004 None DONE LDK 9/7/2004 TLG Photos by TFR ENFB006 Notification of Owner 9/15/2004 None DONE TLG 9/15/2004 TLG Cert and 1st class. Repair by 10-14-04 9/15/2004 None DONE TLG 9/15/2004 TLG ENFBO18 Notify Other Legal Interests Called and spoke with Jim of Arrowhead Realty 830-0122. Faxed him copy of Notice of Violation 830-5204 ENFA900 Telephone Call 10/15/2004 None DONE TLG 10/15/2004 TLG Returned a call to Johnnie Carey and got Gary. He said they just bought both properties at 191 and 181 and it is in escrow. They have L&I permit for deck to show good faith. Told him needed building Permits for both decks on both sites and to check with L&I on the other MH repairs(doors,windows,roofs etc). Gave them until 1/l/05 to submit as escrow is 60 days. They will continually check to make sure the units are secured against entry. LDK 12/7/2004 TLG ENFB002 Site Invest 12/6/2004 12/6/2004 None DONE structure vacant and secured against entry 12/6/2004 None DONE TLG 12/9/2004 TLG ENFA500 Photos attached. See Documents ENFB002 Site Invest 12/9/2004 12/6/2004 None DONE LDK 12/9/2004 TLG no deck demo at this time. 12/7/2004 None DONE TLG 12/7/2004 TLG ENFC050 Complaint Closed As long as vacant and secured complaint is closed CaseActicity_rpt Page 1 of 2 Case Activity Listing 7/17/2008 j Case#: ENF2004-00393 1:43:OSPM 1� Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated By ENFA900 Telephone Call 6/22/2005 None DONE TLG 6/22/2005 TLG LMOR returning Gary Gordon's call. In formed hi m deck issued under sep. permit must be finalled and we need proof of L&I alteration permit and inspection approval for rooftwindow repairs to home before we can lift our tag. ENFC004 Complaint Resolved 11/21/2005 None DONE TLG 11/21/2005 NR Final Occupancy approved when deck was finalled in July 2005. Proof of L&I permit and inspections provided at time of inspection. ENFBO15 Cert.Notification Status 9/14/2004 2/7/2007 None DONE KLW 2/7/2007 KLW UNCLAIMED,LETTER REFURNED ON 10/1/04 Page 2 of 2 caseActivity..rpt