Loading...
HomeMy WebLinkAboutBLD2021-01498 SFR - BLD Inspections - 11/1/2024 w M MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 SHELTON:360-427-9670,EXT 352 dal COMMUNITY SERVICES BELFAIR:360-275-4467,EXT 352 Building Planning Em/uonmantal H«Ith.Community Health ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2021-01498 Date Issued 09/27/2023 Issued By Project NEW SFR Site Address 81 E Gibler Ln Applicant PRINTZ RONALD A&JULIA C Contractor Contractor Phone Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED." PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks Slab / Z 2 Footing Per eter - MAIPoint load Footing a— Footing Interior Footing Decks/Porches Foundation Stem Walls IZ/&/Z3 I a Other Rough-In Groundwork Plumbing /2-ZZ_-Z3 D6Ci Framing D - Groundwork Mechanical Plumbing _ -Z Groundwork Gas Pipe Mechanical -2 C Gas Piping Shear Wall Nailing L� Underfloor Other Insulation Slab / /174 ZY � Ceiling 10 12.1 I.ZtA Floor Vaulted Ceiling Walls 5 1y-2&4 DlE Vapor Barrier ///Z/LV 74 Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other fzov+�a, 0+1 �. l Z I 23 0. Sw ►°r t+ Tl2 o C'L s..��►�'�'r `D�JA{ �a%V 0,-Opo-'A MA VJ'* f/ -FW( s 3-Zq aGC .sz,4A' h MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: -SLD 20 Z t - o 14 9$ ADDRESS/LOCATION: FINDINGS: r - K M r F�TZ qr Cotft.c\--Qjn a-o AA& S COIN-64- S 3f AN 1�t7s Sl�,ll 1 l� T1ccl in -it)'� 4 q &r 5s4 t✓o a- (.c *-. a^A Co ry vt cu, AiCj, W 4 t r �Z No- ; aO jr . Qa uoJ'd4-rS (y- W,"-,on WPr GoJ Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: 12 /1 /2-3 ❑ Please contact our office regarding possible Department: 3tD structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector: �CS� CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC 14.12 A,' MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: lz-2L 11 h ffi25 ADDRESS/LOCATION: �,(^ FINDINGS• 1r r( -k YVON r r rti V kS u,S Items listed above must be corrected to lain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Dater ` ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: o;tf �' "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 i 1 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: XZP2QZ 1-O<Y`T8 ;ADD OCATION: aila er i-t.] IN INGS: of -(�Z �w l'o IJ/`e& EiL l7� .�7- oAt ec� �0 zef� � Eu�,.�1( WA j�rmllf- 6 C. reSS' Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make correction , items will be checked on the next inspection. OK to FAGS Date: Please contact our office regarding possible Department: 13LD_ _ structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a " CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 IPage1 INSPECTION RESULTS MASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584 Permit Asslstanu Center,Budding,Planning (360) 427-9670 ext. 352 Application# BLD2021-01498 Application Type NEW SINGLE FAMILY Owner PRINTZ RONALD A& JULIA RESIDENCE C Parcel# 221321100040 Site Address 81 E Gibler Ln Shelton, WA 98584 Inspector Inspection Type Date Status Comments 10-21-24-JQ /-. NO LNI FINAL-PLEASE SEND CONFIRMATION WHEN ELECTRICAL Joshua FINALIZES Quarders BLD-FINAL INSPECTION 10/21/2024 TEMP-OCC,2'Front door roof overhang is tarped please fix roofing and send photo when ((complete calk all exterior penetrations (le water lines and Coax)south side of house OK TO SEND PHOTOS .t i -6. Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2021-01498 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: NEW SFR ISSUED: 09/27/2023 SITE ADDRESS: 81 E GIBLER LN SHELTON EXPIRES: 12/19/2023 PARCEL: 221321100040 APPLICANT: PRINTZ RONALD A&JULIA C OWNER: PRINTZ RONALD A&JULIA C 4516 S 254TH ST 4516 S 254TH ST KENT,WA 98032 KENT,WA 98032 1.206.619.6939 VALUATIONS: FEES: Paid Due U VB Utility, miscellaneous 618.00 $37,005.84 Building Plan Review/Change of $120.00 $0.00 R-3 VB Residential, one- 2955.00 $438,315.15 Use-Onsite Sewage and two-family Plan Check Fee $2,248.06 $0.00 Covered Deck/Carport 438.00 $9,636.00 Plumbing Fees $201.00 $0.00 Plumbing Base Fee $25.00 $0.00 Building Permit Fee $3,458.56 $0.00 Planning Review Fee $240.00 $0.00 Technology Surcharge $123.59 $0.00 Mechanical Base Fee $30.00 $0.00 State Fee-Residential $6.50 $0.00 Mechanical Fees $217.00 $0.00 Total: $484,956.99 Totals : $6,669.71 $0.00 FIXTURES City Mechanical Fixtures (sty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Clothes Washers 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers 1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks 1.0000 Heat Pump(s) 1.0000 Other 1.0000 Propane Tank(s) 1.0000 Number of Water Heaters and or Vent Printed by:Genie Mcfarland on:09/27/2023 11:50 AM Page 1 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2021-01498 (Qty Mechanical Fixtures Qty Plumbing Fixtures 4.0000 Spot Vent Fan(s) 2.0000 Number of Bath Tubs 5.0000 Gas Outlet(s) (1-5) 3.0000 Number of Hose Bibs 3.0000 Number of Showers 4.0000 Number of Toilets 6.0000 Bathroom Sink REQUIRED INSPECTIONS Progress Inspection Shearwall Inspection Progress Inspection Framing Inspection Setback Inspection Rough- Plumbing Inspection SLAB INSPECTION Mechanical Inspection Underground Plumbing Insulation Inspection Slab Insulation BLD-Final Inspection CONDITIONS " The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. Printed by:Genie Mcfarland on:09/27/2023 11:50 AM Page 2 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2021-01498 * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Genie Mcfarland on:09127/2023 11:50 AM Page 3 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O21-01498 Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Genie Mcfarland on:09/27/2023 11:50 AM Page 4 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2021-01498 * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * The foundation/footing must be placed on undisturbed, firm-native soil. * Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * All property lines shall be clearly identified at the time of foundation inspection. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. Printed by:Genie Mcfarland on:09/27/2023 11:50 AM Page 5 of 7 � 1 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2021-01498 * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * AIF changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls,foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration;and the solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3& R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in '/<or'/z sheets. The Mason County Permit Center will also have some available. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. Printed by:Genie Mcfartand on:09/27/2023 11:50 AM Page 6 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2021-01498 Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1Oft setback from all footing/foundations. B.)Septic tank(s)requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/ Reserve area. Applicants must have a satisfactory Operations and Maintenance inspection prior to final occupancy. Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheets S1-1 and S2-1 designate wall(s)type SW2, SW3 and SW4 with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Author d Agent: Date: -i 12-112-3 Printed by:Genie Mcfarland on:09/27/2023 11:50 AM Page 7 of 7 �,,i� rzlsl23 s� ACUTE Contact: Ron And Julie Printz ENGINEERING INC. Company: Ron And Julie Printz 744 S.400 E. Phone: (206) 619-6939 Orem, Utah 84097 Fax: Phone 801.229.9020 Prepared by: BTD/SJ Fax 801.224.0050 BO Letter Number: 951223 info@acuteengineering.com Engineering Addendum Project Name: Printz Lake House (Mason County) 7630821 Project Location: 81 E Gibler Lane Mason County, Washington 98584 Project Number: 7630821 Date: 12/4/2023 The following is in response to an email from Daimon Doyle on 12/04/23. It was requested to find a solution for PAB anchors that were not installed in the footing. • See attached for updated schedules and drawing. This addendum is for the project and location listed. It may not be reused, copied or reproduced without written consent from Acute Engineering Inc. N TOQD m �3 55212 /STER�� \C\� �SS/ONAL ECG 2 EXP:08/04/2024 Valid Wet Stamp In Red c � HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM ANCHOR POST FASTENERS D CS16 10d X 2-1/2" FLOOR STRAP (11"END LENGTHS) (.148 X 2-1/2") ( ) (2)2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2") (FLOOR STRAP) (2)2X POST J HDU2-SDS2.5 SDS1/4"X 2-1/2" SSTB16 (2)2X POST (SDS25212) l K HDU4-SDS2.5 SDS X 2-1/2" ® (2)2X POST (SDS25212) L HDU5-SDS2.5 SDS1/4"X 2-1/2" ® (2)2X POST (SDS25212) 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE"RX TYPE AT RIM JOIST LOCATIONS. 71 m 55212 RFCISTER�� �ss/0 ENG 2 EXP:08/04/2024 Inspire From: Daimon Doyle Sent: Monday, December 4, 2023 8:42 AM To: info@accuteengineering.com Subject: Printz Project 7630821 Hello, We are the general contractors for the Printz project in Mason County,Washington. Walls marked with "K"& "M" are calling for a PAB5 and PAB7 with 5" embedment into the footing, however due to topography,the walls at those locations ended up being 36" and 48"tall. In the past with taller walls,we've been allowed to forgo having the bolt into the footing using alternative embedment. If this is acceptable, could you please provide us with as letter we can submit to the AHJ. If not, please contact us so we can determine an alternate solution. Respectfully, Daimon Doyle MCGP,GMB, CAPS RESNET Accredited HERS Rater, Energy Star/Indoor airPLUS Verifier c: 360.789.8030 o: 360.791.3611 300 Deschutes Way Ste 215 Tumwater,WA 98501 Doyle Construction,LLC dba: Inspire 2 Sarah Jeanne From: Brandon Decker Sent: Monday, December 4, 2023 10:16 AM To: Daimon Doyle Cc: Brandon Decker Subject: RE: Printz Project 7630821 Daimon, The"PAB" bolts are really designed to be in a footing,and they don't give me a lot of capacity in a stem wall. • For the"K" hold-downs, it looks like I should be able to get them to work as SB5/8X24 bolts(or possibly even SSTB24 bolts). • For the "M" hold-downs,they will need 8"wide stem walls and then I can get them to work with SB7/8X24 bolts. We'll get started on a letter for this, but let me know if you have any concerns about these solutions. Brandon Decker, PE I Partner I Acute Engineering, Inc. Oregon Office: 3800 SW Cedar Hills Blvd Ste 145, Beaverton, OR 97005 Corporate Office:744 S 400 E,Orem, UT 84097 Work:801-229-9020 1 Fax: 801-224-0050 This message is intended solely for the recipient and should not be opened, read, or utilized by any other party. This message shall not be construed as official project information or as a direction except as expressly provided in the contract documents. From: Daimon Doyle<ddoyle@inspirehomes.com> Sent: Monday, December 4, 2023 8:57 AM To: Brandon Decker<brandon@acuteeng.com> Subject: FW: Printz Project 7630821 You don't often get email from ddoyle@inspirehomes.com. Learn why this is important Daimon Doyle MCGP, GMB, CAPS RESNET Accredited HERS Rater, Energy Star/Indoor airPLUS Verifier c: 360.789.8030 o: 360.791.3611 300 Deschutes Way Ste 215 Tumwater,WA 98501 Doyle Construction, LLC dba: 1 FH Sm SW4 FH rrP. BL L ii L L L L L SW4 SEE SCHEDULE FOR TIGHTER ANCHORAGE SPACING (P. GT �a a a y 3 � 1 w i r QON r-o mow_TO BE OF THAN 12'd' I, W ME rn REQUIRED SHEAR WALL CHANGES 3 lP 55212 FPS' Fc/STEREO s��NA L QNP' FkP• 2 2 •08/04/2024