Loading...
HomeMy WebLinkAboutBLD2000-00650 Final SFR and Garage - BLD Permit / Conditions - 3/21/2001 Inspection Line (360)427-7262 MASON COUNTY PERMIT ASSISTANCE CENTER Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT - os5o OWNER: ED BLAKE RECEIVED: 06/05/2000 CONTRACTOR: SITE ADDRESS: 172 NE MEEK HILL RD BELFAIR ISSUED: 09/200 0 PARCEL NUMBER: 123307590063 EXPIRES: 02109/2001 LEGAL DESCRIPTION: TR 6 OF SURVEY 2/149 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE AND GARAGE BELFAIR WEST ON N SHORE RD, R ON SAND HILL RD, L ON BELFAIR MANOR, R ON MEEK, ON RIGHT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: 5N Type of Use: SF Insp. Area: No. of Bathrooms: 2 Occ. Group: R3U1 Lot Size: Deck: Type of Work: NEW Fire Dist__ 2 No. of Stories: 1 Occ. Load: Building:1,340 Garage-Attached 533 Valuation: $80,211 11 Building Height: 15 Occ. Status: Primary Basement: Cvr Porch 16 Manufactured Home Information Setback Information Shoreline & Planning Information Make Length: Ft. Front: W 80.0 Ft. Shoreline Ft. Water Body: g Rear: E 197.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: N 60.0 Ft. Shoreline Desig.: Year: Serial No.: Side 2: S 61.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Adjust Plan Check Fee MJB 08/02/200 $4.07 BELFAI Hosebibs 2 Furnace<100K 1 Building State Fee MJB 08/02/200 $4.50 BELFAI Kitchen Sink 1 Ventilation Fan 2 Building Permit Fee MJB 08/02/200 $768.50 BELFAI Lavatories 2 Woodstove 1 Mechanical Fee MJB 08/02/200 $77.75 BELFAI Showers 1 Mechanical Base Fee MJB 08/02/200 $22.00 BELFAI Water Closets (Toilets) 2 Plumbing Fee MJB 08/02/200 $75.00 BELFAI Water Heaters 1 Plumbing Base Fee MJB 08/02/200 $20.00 BELFAI Bath Tubs 1 Planning Review Fee KS 08/07/200 $38.00 BELFAI Clothes Washer 1 EH Plan Review KS 08/07/200 $50.00 BELFAI Plan Check Fee KS 08/09/200 $495.46 Total $1,555.28 BLD2000-00650 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR • BLD2000-00650 CONDITIONS FOR BLD2000-00660 1) This application is subLectlo Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) The use, handling and storage of hazardousat or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 3) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposers to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect yop ject X 4) Proposed structure or any portion thereof greater than 30" in height from grad in , mu maintain a minimum of 5'setback from all property lines, easements and 10'from all County and State Road right of ways. X 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X 6) Approved per dimensions and setbacks on submitted site plan. X 7 All upland areas disturbed or newly creat co truction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 8) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(minimu�) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X BLD2000-00650 Please refer to the following pages for conditions of this permit. 2 of 3 9) ' PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X 10) The plan review corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked APPROVED, they may not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply will result in failure of required building inspections. Every permit shall expire by limitation and become null and void if the building or work authorized by such permits is not commenced within 180 days from the date of issuance, or if the building or work authorized b its is suspended or abandoned at any time after the work is commenced for a period of 180 days. X � 11) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan is not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour (mine 1,�our) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X �� 12) UMC Chapter 7. In buildings of unusually ti c n s�Wc tion, fuel burning appliances shall obtain combustion air from outside (excluding cooking appliances and clothes dryers). X 13) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 14) Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code, 1991 Ventilation and IncLoor Air uality Code, the Uniform Building Code and/or Mason County Regulations must be approved by Mason County prior to constructionX 15) CONSTRUCTION PROCES BE LD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE.x 16) All property lines shall be clearly identified at the time of foundation inspection. X '� ZZ This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied, l� OWNER OR AGENT! DATE: BLD2000-00650 Please refer to the following pages for conditions of this permit. 3 of 3 F E c-p/,® MECHANICAL MOBILE HOME F uetback date - c ` _ � et {� b �� 2 by/ %/I Ribbons .._ y Gas Piping date b a ti, r:;.lation�Walls date b Set Up date by INSULATION date by BG/SL, �Insulation Floors Final date FRAMING by date by date by Walls ,.-/� FIRE DEPT. date 2. -D d 0 by date Z -_G�l'i0 by/ /� date by PLUMBING OTHER Groundwork Attic date b date by D.W.V. _ WALLBOARD NAILING date by date —/ <-- by Water Line FINAL INSPECTION date —2-2 -ccl, by 77Q date /_d� by 7--� date by � �e�s r P•�� �� �-o Ago v P � �IAQi�o �� t3�.9cX Ly�/,ls 16 � •'Y%�� T,���i:>.�� G c.ems �'i�.L r� �.c��'-,-1 . I -Z2 Tidemark Residential Plan Review Entry Checklist See Conditions on reverse BLD2000- OO 6,60 Area Information Applicant: W-g Lot Size: Building: T 3 9 O Construction: Occupancy: Basement: 5 N Deck: Bedrooms: 3 Type of Const: Garage: 533 et Bathrooms: c Occupancy Group: 93 U) Carport: AtUDet Stories: I Occupancy Load: Cvr Porch: 16 Bldg Height:_ Occupancy Status: Other: Plumbing: Mechanical: Water Closets: 7.00 Furnace: 1 13.25 13,35 Lavatories: I I q, 7.00 Heat Pump: 9.50 Bathtubs: i 7.00 Vent Fans: a 6.50 �3,00 Showers: 1 1 7.00 loe 7.°o Range Hoods: 1 9.50 9,5 O Water Heaters: 1 1 7.00 Wood Stoves: j 42.00 w D•OO � Clothes Washers: 1 1 7.00 Gas Stoves: 42.00 Kitchen Sinks: I I 7.00 Propane Tank: 9.50 Laundry Sinks: 7.00 Gas Outlets: Dishwashers: 1 1 7.00 List gas appliances ` Hose Bibbs: t 5 00 Subtotal '?5,IXo Subtotal ?l 7 S Base Fee 20.00 Base Fee 22.00 Total Plumbing `1 S. `'° Total Mechanical Valuation: Fees: Use: Square fee Amount Dwelling R3: 13,1 D 52.18 `131,a 0 Plan Review: y `i s`3 Garage U1: 533 18.92 to,og,4,34, >' Building Permit: 746. so Deck: 9.50 State Bldg : Covered Deck: Flo 12.85 X or.6G Mechanical Subtotal: Carport: 12.85 Mechanical Base: DO Storage: 11.00 Plumbing Subtotal: 7 S,pD Basement: 15.58 Plumbing Base: aO,pp Remodel <50% 16.00 Remodel >50% 52.18 Total Fees $ Prepared by: f3 Total Valuation $ li�o,,�t I i(o Date: .9- o 1001 PLANS REQUIRED ON SITE All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site,approval will not be granted In addition,a re-inspection fee in the amount of$42.00 per hour(minimum 1 hour)will be charged and must be collected by this department prior to any further inspections being performed or approval granted. 1002 POST ADDRESS Pursuant to 1997 Uniform Building Code,all sites must have approved numbers or addresses provided in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee,based on rates as adopted by the jurisdiction and the 1997 Uniform Building Code will be assessed if owner/contractor fails to post address on site prior to requesting inspections. 1003 PLAN REVIEW CORRECTIONS The plan review corrections,along with the Energy Compliance worksheet(when applicable)are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked APPROVED, they may not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply will result in failure of required building inspections. Every permit shall expire by limitation and become null and void if the building or work authorized by such permits is suspended or abandoned at any time after the work is commenced for a period of 180 days. 1005 UNHEATED STRUCTURE This structure is considered unheated space(not to exceed 1 watt/square foot or 3.4 BTU41R/square foot). At such time this condition changes,a change of use permit and a mechanical permit shall be applied for and approved prior to the change. 1006 SLAB INSULATION All slabs within the heated space shall be insulated to a minimum of R-10 for 24"total. Monolithic slabs shall be insulated around the perimeter vertically from top of slab to bottom of footing. 1007 INTERIOR REMODEL Any exterior wall cavities exposed during construction remodel shall be insulated to full depth of cavity and inspected prior to covering. 1008 MECHANICAL PERMIT All furnace installations shall meet the minimum efficiencies set forth in the 1994 Washington State Energy Code(WSEC). Any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth in the 1994 WSEC and the 1997 Uniform Mechanical Code. 1009 ROOF REPLACEMENT Single rafter joist roof replacement shall be insulated to a minimum of R-30 allowing for a minimum of one inch continuous vented airspace above the level of insulation. 1010 ROOF REPLACEMENT/EXPOSED DECKING Enclosed roof systems that are exposed to the sheathing shall be insulated to a minimum R-30 and inspected prior to cover. 1012 PLOT PLAN REQUIRED ON SITE The approved plot plan is required to be on site for inspection purposes. If inspection is called for and plot plan is not on site,approval will not be granted. In addition,a re-inspection fee in the amount of$42.00 per hour(one hour minimum) will be charged and must be collected by this department prior to any further inspections being performed or approval granted 3006 COMBUSTION AIR UMC Chapter 7. In buildings of unusually tight construction, fuel burning appliances shall obtain combustion air from outside(excluding cooking appliances and clothes dryers). 4999 FLAMMABLE& COMBUSTIBLE LIQUIDS The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshall. 5000 U-1 USE ONLY No occupancy. This structure is limited to U-1 use only(private garages,carports,sheds,and agricultural buildings). Any other use will be in violation of the Uniform Building Code and Mason County regulations unless a"Change of Use"permit is approved. 5001 SPECIAL INSPECTION 1997 UBC Chapter 17,Section 1701: Special inspection is required for the 3000psi concrete. All reports shall be required to be provided to the Mason County Building Dept. prior to the final inspection, provide copy of approved testing laboratory certification to the Mason County Building Dept or as approved by the Building Official. 5002 ENGINEERING Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed,approval will not be granted. In addition,a re-inspection fee of$42.00 per hour(one hour minimum) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. 5003 ALL CONSTRUCTION All construction must meet or exceed all local codes and UBC requirements and occupancy would result in permit revocation. Change of use must be approved prior to change. 5004 WSEC RESIDENTIAL HEATING EQUIPMENT Installation of heating equipment in single family residences shall meet the requirements of the 1991 WSEC. The furnace to be installed shall not exceed 150"/o of the heating design load or prescriptive requirements of Chapter 9. Furnace efficiency shall be .78 AFUE or higher. Ducts shall be taped, sealed and mechanically fastened with a minimum of 3 fasteners per joint. Ducts shall be insulated to R-8. 5008 NON CONDITIONED AREAS This is a non-heated addition(separated from existing home by exterior doors or windows or both) and by being designated as such is exempt from and will not be constructed to meet the minimum Washington State Energy Code requirements. 5025 SIDEYARD SETBACK Proposed structure or any portion thereof greater than 30"in height from grade line,must maintain a minimum of 5'setback from all property lines,easements and 10'from all County and State road right of ways. 5026 STRUCTURE SETBACK Proposed structure or portions thereof with a projection over 30"in height from grade line must maintain a 5' separation distance between adjacent structures and that furthest projection. 5030 CHANGES TO APPROVED PLANS Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code, 1991 Ventilation and Indoor Air Quality Code, the Uniform Building Code and/or Mason County regulations must be approved by Mason County prior to construction. 5045 FIELD CORRECT Construction process to be field corrected as required per Mason County Building Department and Uniform Building Code. 5090 PROPANE TANK If the tank size is between 125 and 500 gallons you must follow these guidelines: 1,Tank is to be 10 feet from any building,public way or property line. 2,If the tank is exposed to probable vehicular damage,provide protective bollards. 3,All weeds,grass, brush,trash,and other combustible material shall be kept a minimum of 10 feet away from LP containers. 5095 FUEL PIPING/GAS PIPING Fuel piping shall be inspected after the installation of gas piping is complete,and before the attachment of fixtures,appliances,or shut-off valves. At the time of inspection the test pressure shall be no less than 10psi held for no less than 15 minutes. Appliance attached to the piping shall not be used until the final inspection has been approved by the building inspector. 5510 PROPERTY LINES All property lines shall be clearly identified at the time of foundation inspection. 1000 CUSTOM CONDITION P:.,Y, -C) T PERMIT NO.: BL D �� S'1 MASON COUNTY B DING PERMIT APPLICATION G� 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 1�bz) APPLICANT INFORMATION CONTRACTOR INFORMATION Owner A�ZLJ i/tzi C 6L4KJE Contractor Name ow/VF- C Mailin Address Nc4J 'A A Mailing Address J471fE CityeQReme StatewN Zip Code City State Zip Code Phone 60 3' 7 Other Ph.( Ph.( Other Ph.( Lien/Title Holder Contractor Address Expiration SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic _Existing Septic Connect to Sewer System Name of Sewer System Well X Water System Name of Water System cJ Ei-L L.e W7X 54.S 4t PARCEL INFORMATION-12 digit Tax Parcel No. ,330 / r�/7OD�.,3 Fire District Legal Description 4 TtA cat Cb Site Address(Please include street name, street number and city) / & NE MELX /'(iL.t. Directions to siteBELFArA WEST oAd N. 5He" Q, R Dw %S+lo,0 N.LL R,11 L 6.y &-c4I=A/R Will timber bd cut and sold in parcel p eparation? (Yes/No)A)ep _ Is your property within 200' of the following: Body of Water (Name) A11A Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs PERMANENT RESIDENCX SEASONAL RESIDENCE❑ TYPE OF JOB NewX_Add Alt Repair Other Use of Building RRxAbRAj r-E Describe Work Qu r L a NEW ,3 &&^1 R4M41L&oQ No. of Bedrooms.d No. of Bathrooms SQUARE FOOTAGE-1st Floor/.730 2nd Floor_U4 3rd Floor Loft Basement ,VA Deck AAOs Other sq. ft. Garage )( d Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make Model Model Year Length Width --Seri I No. of Bedrooms No. of Bathrooms Type of Heat PurG�hase Price $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of,the' CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinancb contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be;done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first gbtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. Date X /U Date FOR OFFICIAL USE BEYOND THIS POINT �1 Accepted by ~� DateSubmittal Amount Du -. .4 Receipt No. �,.�; ................. QEPARTM..ENTAI» REVIEW APPROVED DENIED CONDITJON C0pE5 Building Department Occ Group U I Type Constr. 5�J g Planning Department Environmental Health Department Public Works Department I Fire Marshal Valuation $ ...................................... F�1=S Building Permit Fee 76(?,SO Site Inspection Plan Review,.Fee `tr (0 9�� S3 UFC Plan Review Fee Plumbing & Base Fee ' q J Public Works Review Fee Mechanical & Base Fee 9 Ct )S Other SirA.- �,so Wood/Gas/Pellet Stove Fee Other iefattorree r Q Pre Paid at Submittal ( yqs y(o ) OTALFEES FORM MUST BE COMPLETED IN INK PERMIT NO.: PLEASE PRESS HARD MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton(360)427-9670 Belfair(360)2754467 Elma(360)482-5269 Seattle(206)464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATION Owner F Dc.,04" F_ 23 (.04Xf- Contractor Name 414 4 &ME Ot'2&`eA Mailin Address �".�`/� h!� OwtYE6 Mailing Address City >�R1=M AN State LA%OV Zip Code c?e3%Z City State Zip Code Phone( 3�co) 3'fi,Y3 7 Other Ph.L__, Ph.(_ Other Ph.L� Lien/Title Holder Contractor Reg. # Address Expiration SEPTIC INFORMATION-Connect to New Septic___?S_Existing Septic Connect to Sewer System Name of Sewer System PA vr4-TE PARCEL INFORMATION-12 digit Tax Parcel No. /a J 3 / 7S` / ),co 63 Fire District Legal Description _ Site Address(Please include street name, street number and city) i 7.4 NE /'fEek 0,4,<-L Directions to site BELF*I VV 6A) Al 3*XE Rb . P, 8N 3,JA)Z ,1,L Rb : L 0.-1 ACLF-tJ),Z MFk�l;cla d a�3 A%t wf�F_K /+� LL! 2i r�ry %1 Is your property within 200' of the following: Body of Water(Name) Saltwater Lake River/Creek Pond Wetland _Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New__X_Add Alt Repair Other Use of Building RES i a EAjc.E Location of Fixtures/Units 1st Floor ..&_2nd Floor Basement Garage_ Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Fuel Type: Electric_ Type of Fixture No. of Fixtures Fees LPG Natural Gas Heatpump Toilets �_ Type of Unit No. of Units Fees Bath Basins _�_ Furnace Bath Tubs / Heatpumps _ Showers i Vent Fans 3 Water Heater i Propane Tank Laundry Wsher f Gas Outlets Sinks �— Wood/Gas/Pellet Stove Dishwasher "' Direct Vent? Other Other Other _ Other Base Fee Base Fee- TOTAL PLUMBING TOTAL MECHANICAL A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. t X `t'i. 4�kDate 691. nZ' X Date FOR OFFICIAL USE BEYOND THIS POINT Accepted by IkT/ Date Submittal Amount Due Receipt No. DEFARTf1AF..tVT, R£11iE'rN:;:::';: >.'::. '.'AF'RL1V D:: DENIEf? QR[DtTICIT--:CODES.': :::. Building Department Occ Group Type Constr. Planning Department Other Other FEES Permit Fee Site Inspection Plan Review Fee UFC Plan Review Fee Plumbing&Base Fee Other Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( ) Violation Fee TOTAL FEES FORM MUST BE COMPLETED IN INK PLEASE PRESS HARD MASON COUNTY PROJECT SITE INFORMATION Case No. Name F-,hWf f4.h E BLrtKE PARCEL NUMBER /��.3d '75- '7004.3 Date�� SHOW THE FOLLOWING ON SITE PLAN Show Direction by indicationg N, S, E, W in relation to the site plan Lot Dimensions feQG"- E Driveways ` Structure Setbacks `Strvreffm . Water Lines Topography Well Location (including adjacent) Drainage Plan m Easements Names of Fronting Streets Septic System 1 �/ DRAW SITE PLAN BELOW Include adjacent propertie if on shorelin or within 100 feet of adjacent property line. adjacent property lined Fadjacent property line LOT I ' I Aq I I I x 4 I l� r�i4StKtJ`' adjacent property line4 I E-ItA,�� '! I <-adjacent roe line SAMPLE SITE PLAN 1 7- adja t property line--) 3io� _ \ Fadjac nt property line D 30' �rz�saaVe t SE w a L _St I I Hone 6 I GnsEN crlEE1G \ I n I . 1 j PMOP0%Az smpttc �I I 1 — I � bo' —/SO �11 I VAGwT I fi [,y1rtAG6 � I % I d I i T A&R=u_LrLjXAL90, 50 I 80 I I \ 1 \ I c1.eLL I \ I I l_a_.e_LL I adjacent property lined ; ��. \; Fadjacent ro ert' line TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. If possible include height and the degree of slopes. See sample topography profile.) SAMPLE TOPOGRAPHY PROFILE aI s+a.,« to ru.cfit.�►'e � 1;.S to r,cG to Slop¢ fio¢ e1�+3„_ g� t o L Signature Date