HomeMy WebLinkAboutWEL2024-00044 - WEL Application, Design, Letter - 10/16/2024 MASON COUNTY IDENOWED
COMMUNITY SERVICES OCT 16 2024
mawap ra.�wa eww„sad arm,rn.,.+srr lrrw
415 N 6s Street, Bklg 8, By
Shelton WA 98584
Shelton:(360)427-9670 ext 400 4 Seller: (360)275-4467 ext 400 -} Elma: (360)482-5269 ext 400
FAX: (360)427-7787
APPLICATION FOR WELL SITE INSPECTION
Permit Number ! Payment Information Instructions
I 1. Complete Part 1. Incomplete applications will be rejected.
WEL Receipt Number 2 - 2. Attach a detailed plot plan.
QO/tr-OWQy ❑ Cash 3. Clearly slake out or flag the well site.
g Check ,/ 4. Submit application and appropriate fee to Mason County
Dale of Payment /0 'Z7 Public Health. Refer to Mason county Environmental Health
Fee schedule for cost.
PART 1:Applicant I Parcel Identification
Water System Name Rolling Acres
Site Address 1100 E Johns Prairie Rd. Shelton, WA 98584
Applicant Thomas Wolter Phone (206) 200-3325
Mailing Address PO Box 76, Allyn, WA 98524
City Shelton State WA Zip 98584
Parcel Number 320082100000
Directions to Site From Northcliff Rd turn right onto E Johns Prairie Rd then turn tight at 1100 E Johns Prairie Rd. Follow
the dirt road, go straight at the first intersection then turn left at the first and second forks in the road.
Water Source is: ® New ❑ Existing System Type: ® Well ❑Spring No.of Proposed Connections 14
PART 2: Health Department Review(Staff Use Only)
YES .NO NA
❑ IEt ❑ Evidence of existing sources of contamination within 100 foot radius of water source?
7 (drainfields,tanks, buildings; indicate distance on plot plan)
❑ �, ❑ Are there roads within the 100 foot radius of the water source? If so,is road private, County or State.
What is distance to ROW?
❑ ❑ Does the ground slope away from the water source site? (show slope on plot plan)
❑ ❑ 151Zrrcc Is the well cap satisfactory?
❑ ElScreened and vented?
The well casing extends above level ground/concrete slab? (circle one)
❑ ❑ Is there evidence of a surface seal?
❑ ❑ 1p Does the seal appear adequate?
❑ % ❑ Is a variance necessary for well site approval? �7 7Z�� 7
Com ents ,
(01
- a3. 1z0 _
Pass ❑ Fail Inspector l 1( Date 110—21 —2,V _
This form maybe sc nd available for ublic view on the Mason Coun Web site.
nrvlaw reeect observed co m Itions es they etlsted on the day or aie rile Inspecean.No dakw b made,expnm or en ed tithe lulu
re of this system.Well Site passage does not constitute water system approval.Water system approval is a two pan process.
1118 well site.2)Approval of the wabr astern design.Once the wes site Is passed the waters n may be submitted for review
]:\EH Forms\DRINKING WATER FORMS\Drinking Water Well Site Inspection App.docx Revised: 1/2 012 0 1 7
i
City of Shelton Letter of Denial - fwd 8/15/24
Thomas Wolter <tom@thomaswolter.com>
Thu 8/15/2024 1133 AM
To Allison Whittle <allison@nwwatersystems.com>
Cc:southshore@q.com <southshore@%com>;Thomas Wolter<tom@thomaswolter.com>
Hi Allison(with a copy to Rich):
This is what I reed last August. I just requested an update.
Sent:Tuesday,August 15, 2023 1:32 PM
To:Jason Dose<jason dose@sheltonwa.gQy>;Thomas Wolter<tom@thomaswoltercom>
Cc:Brent Armstrong<brent.armstrong@sheltonwa.gy>;Jae Hill<jae hill@.sheltonwa.gov>
Subject:RE:Water Moratorium
Thomas:
Yes, we currently have water storage deficiencies in Mountainview Pressure Zone per the 2023 Water
Comprehensive Plan. Phase 1 of the Olympic Heights subdivision (near Olympic College) submitted a
land use application with the City and is proposing to complete a water line extension project from the
Upper Mountainview reservoir system to remove the dead storage from the Mountainview reservoir
which should add capacity for their development and potentially some capacity for additional lots in the
pressure zone. We should know if there is any additional capacity for others to connect to the system in
the next month or so.
Long term, future phases of the Olympic Heights subdivision will be constructing a new 750.000 gallon
Mountainview Reservoir per the 2023 Water Comprehensive Plan to serve their project and the ultimate
buildout needs in the Mountainview pressure zone.
Currently we do allow some limited connections to the existing water system for single family home lots
adjacent to an existing waterline and for some expansion of existing uses, but not for new subdivisions
without completing some system improvements.
Thank you,
Jay Harris I Director of Public Works
City of Shelton,Washington
T:(360)432-5125
M:(360)490-8567
E:joy harms@sheltonwa.gov
The City of Shelton is subject to the Washington Public Records Act, Chapter 42.56 RCW.
This message and any attachments may constitute records subject to public disclosure pursuant to the Act.
� k!
, q Z ( \
` �i§ - � ( ! 4■!!!
\ / #§)§ ®
# , G .
§ ?� `
\ I) ) -
, ■
; . | |
� , \
§ ! :
)§§ |
§; !
_, ,
| z /§ \
M0 !
§ �
Directions to the Rolling Acres Proposed Well Site:
Address: 1100 E Johns Prairie Rd. Shelton,WA 98584
Front Gate:The gate should be unlocked.
Parcel Map:
Front Gate
Go Straight at
Intersection Well Site
Second Fork
First Fork
Second Fork to Well Site Location:
Proposed WeLL Site Location:
w
;}e.
f
i'
NOTES: LEGEND
SUE INFORMATION PROVIDED BY THE CUENT AND — PARCELBOUNDARY
MASON COUNTY GIS — DIRTROAD
THIS IS NOT A SURVEY.PROPERTY LINES MID 100 SCA
ELEVATIONS SHOWN ARE BASED UPON THE AVAILABLE
INFORMATION AND ARE APPROXIMATE ONLY.
DISTURBANCE OF EXISTING SURVEY MONUMENTS IS A
DROSS MISDEMEANOR UNDER ROW 5T04.015
ONLY RELEVANT PARCELS SHOWN FOR CWiITV
'E
y 100'scA�
e`
P�
Q
y TPN3000d1
3.52 ACRES ACRES
W
PROPOSED
WSITE
ELL
ELV.2]0 EV,270
'
FUTURE RESIDENTIAL
DEVELOPMENT
(14 SITES)
TPN 3200821 XXXX
W.SSACRES
.... AIIII Whine ROLLING ACRES
x.u®BgeWSION M 220307 SITE MAP
July 14, 2024 — 1" =300'
NORTHWEST WATER SYSTEMS, INC.
DESIGN CONSULTING-MMIMEMENT
P 0.BOX IA
PORIORCXARDWAffi96s
(M)8]60358
AIX"I
Planning • Management• Engineering
P.O. Box 123•Port Orchard, WA 98366 • 888-881-0958•360-876-0958
www.nwwatersystems.com
October 7, 2024
Jeff Wilmoth
jwilmoth@masoncountywa.gov
Environmental Health
Mason County Public Health
415 N 6th St
Shelton WA, 98584
Subject: Rolling Acres Proposed Group A(ID# Pending), Well Site Application
Dear Mr.W lmoth,
A well site inspection application and supporting documents are enclosed for the proposed
Rolling Acres Group A water system. The system is seeking approval to become a new Group A
Community water system that will serve 14 full time single family residential connections.
The developer has met with Kell Rowan, the Mason County Building Department Head, who
has assured the developer that they would push for the water system approval, as connecting
with the City of Shelton would be cost prohibitive for the client as well as untimely.
Correspondence from the City shows that they are currently prioritizing other development for
water connections and major infrastructure installation would be required to reach the
developers future subdivision.
The proposed well site is located on the undeveloped 40 acre parcel #320082100000 and is
accessed through parcel#320053300041 off of E Johns Prairie Rd. The proposed well location
is 120 ft south and 110 ft east from the northeast comer of the parcel#320082100000. The 100
ft SCA will be entirely within the parcel. Future development will be 200 ft plus away from the
well site and will also pose no potential risk to the well.
Should you have any questions or require further information, please feel free to contact me.
Sincerely,
NORTHWEST WATER SYSTEMS, INC.
Allison Whittle
allison(a)nwwatersystems.com
(360)876-0958 ext: 121