HomeMy WebLinkAboutFIR2024-00037 - FIR Plot / Site Plans - 10/23/2024 EDDY—THREAD (ASTM A135, A795) Mason Co Fire Marshal PIPE DIAMETER DIAMETER WALL PIPE WEIGHT SCOPE OF WORK SIZE OUTSIDE INSIDE THICKNESS VOLUME +H2O *Approved with Conditions in in in in gal/ft Ibs/ft INSTALL PIPE AND SPRINKLER HEADS FOR NEW KITCHEN TENANT IMPROVEMENT. 1 1.315 1.083 .116 .048 1.860 GENERAL NOTES 1.25 1.900 1.654 .121 .112 2.754 10/23/2024 10 :09 :31 1.5 1.900 1.654 .123 .112 3.468 1. SPRINKLER SYSTEM DESIGN PER N.F.P.A. 13 2019 ED. 2 2.375 2.123 .126 .184 4.842 2. ALL MATERIALS SHALL BE U.L. LISTED OR F.M. APPROVED FOR FIRE PROTECTION. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. 13. 4. SYSTEM ACCEPTANCE AND APPROVAL REQUIREMENTS SHALL COMPLY WITH N.F.P.A. #13. CONDITIONS: 5. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE Piping shall be secured in accordance with chapter 17 WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE , DELUGE AND OTHER TYPES OF VALVES GENERAL LEGEND of NFPA-13 6. FIRETROLLING PROTECTIONTER CONTRACTOR SHALL NOTSUPPLIES TOLER BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY + EARTHQUAKE BRACING LATERAL AND LONGITUDINAL - Use of CPVC pipe shall be permitted only If piping Is SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. EARTHQUAKE BRACING LATERAL protected above a ceiling assembly 7. ALL ELECTRICAL, PAINTING OF PIPE/ PIPE IDENTIFICATION, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. �- PIPE HANGER — BRANCHUNE RESTRAINT 8. SPRINKLER HEADS ARE NOT NECESSARILY LOCATED IN CENTER POINT OR QUARTER POINT OF CEILING TILE. -� RIGID COUPLING U.N.O. RC REDUCING COUPLING - If it cannot be demonstrated that the work area is 9. MODIFICATIONS AFFECTING 20 OR FEWER SPRINKLERS SHALL NOT REQUIRE TESTING IN EXCESS OF SYSTEM PRESSURE. GROOVED CAP TP THREAD x PLAIN served by an auxiliary drain,one shall be provided. 10. BUILDING IS ORDINARY HAZARD 1 OCCUPANCY CLASS IN ALL AREAS AND OR ROOMS UNLESS OTHERWISE NOTED. • CAP GP GROOVE x PLAIN -Work shall not be considered complete until an 11. THREADED PIPE 1" - 2" PIPING TO BE 'EDDYTHREAD'. PLUG GG GROOVE x GROOVE P N FLEXIBLE COUPLING TG THREAD x GROOVE inspection is performed by this office. OX HYDRAULIC REFERENCE POINT TF THREAD x FIT ATR ALL-THREAD ROD -� PIPE UP 'UP' OR DOWN 'DN' (E) EXISTING RISER NIPPLE 'RN' M L MODEL FDC FIRE DEPARTMENT CONNECTION HT HEIGHT PIV POST INDICATOR VALVE TYP TYPICAL KITCHEN - UG UNDERGROUND NPT NATIONAL PIPE THREAD ORD HAZE BOD PIPE TO BOTTOM OF DECK FOS FACE OF STUD BOB PIPE TO BOTTOM OF BEAM FOW FACE OF WALL BOJ PIPE TO BOTTOM OF JOIST AFF ABOVE FINISHED FLOOR \ CH CEILING HEIGHT CC CENTER TO CENTER k'G\ NEW SPRINKLER PIPE ---------EXISTING SPRINKLER PIPE , -O„ —0" o 0 0 4'-7Y2" o N (n N I� N C— N ' I ICD j N N 1.5 1.5 1.5 1. `ID 1.5 1 4-0 7-10 7-10 3— 0 3-10 4 0= TIE INTO EXISTING BRACNHLINES = I TP TG TG TP _z O =OLn I I I J w- o I LLJ �Iw NIA cj N I Iv � I I I SECTION A KITCHEN PIPING PLAN SCALE: 1/4" = V-0" SCALE: 1/4" = 1'-0" FTTTTaD 0 2' 4' 8' 0 2' 4' 8' 0 SPRINKLERS SYM DESCRIPTION SIN TEMP QTY QTY MAX PIPE SIZE 2.5% X=2.5" RASCO MODEL 'F1FR' OR WHITE SEMI-REC. PENDENT 1/2"NPT 5.6K RA1414 155 8 2 FOR PIPE SIZE 3"&4 X=3" SWG-20 1/4"x-2") GST-20 (1/4"x-2 3" MAX PIPE SI E 2.5" MAXI PIPE S E SWG-25-380 (3 f 8"x-2.5") GSI 3 MAX PE 4" MAX PIPE SIZE • 2"OWNER LANDLORD: TAX PARCEL /: 322335000014 ALL THREAD ROD 1 ALL THREAD ROD NORTH ORTY LODGING PO Box 609 FIRE PROTECTION PLAN ��� UNION WA 98592 4ai1--oaosc Le�•i s " FOR ADJUSTABLE RING —ADJUSTABLE RING 1FoxFiP127Pre 8ton,I 1" FlREP.O.BNXI094INC. Fox FIPI127M8 KITCHEN IMPROVEMENT HANGER HANGER 1 ; PORT ORCHARD, WA 98366 ss " ; ALDERBROOK RESORT & SPA `--------------•-•-•-•-----� T. 360.871.1985 F. 360.871.2262 SAMMY SCREW ROD AND RING HORIZONTAL SAMMY SCREW 1/2" 10 E ALDERBROOK DR FOXFIP1127MB 2" 1" 1/2• UNION WA 98592 www.foxfireprevention.com IF SHEET IS NOT 34" x 22" SCALE ACCORDINGLY DRAWN BY ABC I JOB NO.24-320 DATE 220CT24 I DWG NO. 1 OF 1