Loading...
HomeMy WebLinkAboutSWG2024-00401 - SWG Application / Design - 9/30/2024 LTON, WA MASON COUNTY 415NBTHELTON:STREET,SHE7-967 ,EXT 404 SHELTON:36U-427-9670,EXT 400 BELFAIR:%P275-4467,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX:360-427-7787 On-Site Sewage System Permit: SWG2024-00401 APPLICANT RICHARDSON CHRISTIAN & LISA Phone: Address: 23625 253RD AVE BE MAPLE VALLEY,WA 98038 OWNER RICHARDSON CHRISTIAN &LISA Phone: Address: 23625 253RD AVE BE MAPLE VALLEY,WA 98038 SEPTIC DESIGNER PAULA JOHNSON• Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 SEPTIC INSTALLER Bamford Septic Repair, LLC Phone: 360-790-2364 Address: 301 E WALLACE KNEELAND BLVD SHELTON,WA 98584 Site Address: 40 E Creekside Dr Primary Parcel Number: 222215400019 Permit Description: Table IX Repair: 2-bedroom Nu Water BNR500 system Permit Submitted Date: 09/3012024 Pennit Issued Date: 10/09/2024 Issued By: David Anderson Current Permit Fees Paid: $805.00 (additional fees may na Moned upon Installation or system). Permit Expiration Date: 10/08/2025 lased on dale of inspeotion) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Idle 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specked on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/healthionvironmental/onsiteloss-inspection-request.php or call: 360-4278670,extension 400. sl_; a OFFICIAL USE ONLY BY:----------- MR R<EM1'm: 09- 30 - Z MASON COUNTY C N MKVMIE® A_J MTFMOBI m N COMMUNITY SERVICES IUIvMV o m < rn glyEtlyy,(Cmmmunlry XHMM1/EMronmemIDl IMeM) y SWG ZDZq A Z 0 ON-SITE SEWAGE SYSTEM APPLICATION m IT APPLCW 206 920-5340 r Christian & Lisa Richardson ( ) i a MPILINGRDOXE66-STREET CT',STATE,LPCOGE Maple Valley WA 98038 j A 23625 253rd Ave SE o .. ITEAWRE Creekside Dr ESS-ETREETCIT',ZIPCOOE 40 Belfair WA 9B528 v _ xAMECF.sscxe< P 360 898-2255 m I N Arrow Septic Designs ( )PXOXE Q N A! N EOFIN6TALLER (360)790-2364 3 Bamford Septic Repair a N PFAMITTVPEPW>MFl ORINXING NMTFA EDUPCE RESIDENTIALOSS GICOMMUNITYOSS 15COMMERCALOSS PRIVATEINDIVIDUAL WELL 11 PRIWTETWOAARTY WELL Z I � ®PUBLIC WATER SYSTEM , TYPEOF WJRN IHN-"N'Nl 15NEWCONSTRUCTIONIUPGRADES ®REPAIRIREPIACEMENT OT�SURFILS( G EWAG�BE%ISTIN�G FFAILURE (()SHORELINE II�J N I(.11 suMAmALs W I ? DESICN FORM(RFAUIREDI ®SEPTIC DESIGN(REQUIRED) LOT$ME BEDROOMS 2BR .22 acres x o 151WUVER(SI(IF APPLICABLE)) pIRERION$r0&TE ANO SRE LONgTWxE'(o.MWpM1 CD Head north on N 6th toward W Alder St and turn (R). At the traffic circle,take the 3rd exit. Turn (R)onto N 13th St. Continue straight onto E McReavy Rd. Turn (R) onto E Dalby Rd. o I CD Turn (R)onto WA-106 E. Turn (R) onto E Creekside Dr. Destination on (R). iEYUSi NEFIAODED FRDY MAIM NOADAND TEST MOIE9YYSSEEMGGED KiIX FESi ROLE NUYYENB. OFFOAL USE ONLY BELOW THIS LINE My UpG E I FAILURE SOLACE ,CU w�RrC tE TOTARY0'1AIaN Ebcan NmCEUpMMi nP�IlN tsMG 4 ri]e/BUaILDfI NGPE RM IT r]HOMESALE ❑COM PLAINT CO[3M0MTENHTESR BPBCTOR 0LLWE � �3 3 ♦v Y 11" viii of 28',. ?Z" 0 Iz- ( I'. COrvprIONS VfipI '"( t"afw 0Zf" RECORD O.NG ANC m6mll.REPORT ML.00ES: REWIRED FOR FINALAPPROVAL. V.V W G.G VELLY Sz SFXO VLWM S, SVj C�CLAY E-E%IREMELY R-RNT6 CAIE INEPE GNATURE DATE APPLICATION-"'0'OATS RPPUUTION APPROVEq ISSUED BV d bf REVISE. THIS FORM MY BE SCANNED ANCAVAILAdILE FOR PUBLIC VIEW ON THE MASON COUNTY WESSITE rzllmv DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 2 2 1 - 5 4 - 0 0 0 1 9 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dated. "Scaled layout sketch,including all applicable items on checklist Scaled plot plan, including all applicable items on checklist. "Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for public view on We Mason County Web site.Ma imum o er s¢e: II"X/7" :PARCEL IDENTIFICATION Permit N umber: SWG zozq- oONoI Designer's Name: Arrow Septic Designs,Inc Applicant's Name: Christian g Lisa Designer's Richardson Desi er's Phone Number: (360)898-2255 B° Mailing Address: 23625 253rd Ave SE Designer's Address: 171 E Vlaacrest Dr Maple Valley WA 98038 Union, WA 98592 CityState ZipCity Stale Zi -,{ DESIGN PARAMETERS... Treatment Device ❑Glendon Biofilrer ❑Send Filter ❑Mound ❑Said Lined Drainfield ❑Renre.aring Filter,Type: G(AemNc Unit Make/Model NuWato BNR-5W 13Disinfectior,Unit MaktMraiil Other: Drabrield Type ❑Gravity 81(Pressure G(Trench ❑Bed ❑Sub Surface Drip Septic Tank/Drainfreld Specifications Laterals Number of Bedrooms 2 e- Schedule/Class 40 Daily Flow:Operating Capacity 180 — gpd Length 25 ft Daily Flow:Design Flow 240 - gpd Diameter 1.25 in Septic Tank Capacity(working) Nu Water BNR-500 gal Number 4 Receiving Soil Type(1-6) 3 — Separation 5 ft Receiving Soil Appl.Rate 0.8 _ gpd/ft' Orifices Required Primary Area 300 fit Total Number of Orifices 20 Designed Primary Area 300 ftr Diameter 3/16 in Designed Reserve Area 300 fit Spacing 60 in TrenchBed Width 3 ft Manifold Trench/Bed Length 100 - ft Schedule/Class 40 Elevation Measurements Length header IT Original Drainfield Area Slope 3 % Diameter 125 in New Slope,If Altered 3 % Preferred manifold configuration used? Gtf Yes ❑No Depth of Excavation up-ampe 7 in Transport Pipe from Original Gmde Down-Rope 6 in Schedule/Class 40 - Designed Vertical Separation 12+ in Length 80 ft Gravelleas Chambers Required? O Yes ❑No ((Optional Diameter 2 in Pump Required? If Yes 13No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdoses/day 4 Diff.in Elevation Between Pump&Uppermost Orifice 5 it Dose quantity 60 gal DrainSeld Squid Height/Selected Rasidiml(head) 2 ft Chamber Capacity(flood) 1.000 gal Uppermost Drifice If Higher 17 Lower than Pump Shutoff Pump controls:Please check those required ry Capacity @ Total Pressure Head 11.8 SpunB(Timer G(Elapse Meter G Even Counter Calculated Total Pressure Head 7.43 ft If Timer: Pump on 2 initiation; Pump off 6 hours Comments \emPr e1 DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 2 2 1 — 5 4 -- 0 0 0 1 9 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch RJ Test hole locations EX Drainfield orientation and layout Reference depth from original grade: R1 Soil logs Rf Trench/bed dimensions and IK Septic tank Property lines critical distances within layout 19 Drainfield cover ❑ Existing and proposed wells Rr D-Box/Valve box locations ro Reference depth from original grade within 100 R of property � Septic tank/pump chamber and restrictive strata: 69 Measurements to cuts,banks,and locations G( Laterals,trench/bed,top and surface water and critical mess 19 Observation port location bottom ❑ Location and orientation of 19 Clean-out location ❑ Curtain drain collector curtain drain and all absorption Rf Manifold placement ❑ Sand augmentation components 19 Orifice placement Other cross-section detail: 9 Location and dimension of Rl Lateral placement with distance Ed Observation ports/clem-outs primary system and reserve area to edge of bed ig Buildings Other Information Ed Audible/vis eferenced Yes No ib Direction of slope indicator Rf Scale of s on scale 16 ❑ Design staked out Ed Waterlines bar ❑ 9 Recorded Notices attached RJ Roads,easements,driveways, ❑ Rf Waiver(s)attached parking lif ❑ Pump curve attached R1 North arrow and scale drawing ';o .. Ed ❑ Evaluation of failure shown on scale bar FAuIA Jor3sounson'. Non-.residential justification t- It ❑ al�!Waste strength 113 SIF1ow DESIGN APPROVAL The undersigned designer most be no fi by jagm r t time of installation Id ies�� No signature of Designer Date ApRo The undersigned has reviewed this design on behalf of Mason County Public Health and determined i� in ,1 compliance with state and local on-sit q�I 'ons: .tri / 0 Environmental Health Specialist Date 0,1q **e*, ql q T CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may he scanned and available for public view on the Mason County Web site. Updated Date: 1 J]2015 Y ^ t �S fv'L a.M d� Yyy�P � g YI � '•m S EEC � C •w, t •+u. �'• s.p� CIE r!J C IM1 I + n M E y� 00 }` co ----�.q'�'�, —�' �Q r _ 3y�FF,e: q�z`o.��z `5� zc•sRFg9"�y--it ly`S3� � 4 �.Erhpg�F �:1 sga2g �+ 4a a ;EligS [€ "ki ¢-,y j.jlWgg}q}e` 9i9� 1 oa Y ei zgii��+C� Z " '3`z $ SY§s9 s@rE ah T n l ^ ig5rtgFE fig �� E§CY isFeg§ fem A n "-� 2 c<1z fi 2 Eae�tak^$fiae }s,, O r O ^ __�. l x � § i 3=,[xga}•g� dE. 9 �iYffi�rbi pY�T}eie ..a � d v J 1D g `fPs:S1 @jiff E' r a a<qt C SF 0 9^4�EF t 8j U 2$9 �. SIQt.Ic „cajccrl:re „o1Aw.w:-IW.� 10' o-F a.ny Per -PI-L+ --- yy rfo acivaA s s GRKP°C.Y t1: . 0-10" 15 iv is t�l 3q,smee �I � l4°Z4"wetgrn�euy�and, FIV w � z # 2 G-2o"QfS, 2o-Z8" ��' ntck ^v^I S44uca,.tj 2 a� �4 _ — b •F TKEN�FIES@ — I 5- , 0 C- LO I-n F Deck j RESE2��8t7 vE f W/YIURA AJOY J APp ss o: .oz R® ^-- E Creeks ioe �� xe OAudio-visual Alarn- OCTQ Oan Cleout SONCOUNryENVIR0M O2y pVI ENTA(H Pl of plan O NuV✓eter Biz x -soo �+Tv Ta"x A EA(?H O4 1,000` oa ?sh„P�ber t+O,� Glnns}taut tL,.sa �iCha,d�n w J veive Control Box o�Ytel #$22221 54 Ooot9 018Tank +obe !ev✓ ovEtl iD E C�ee�ide D Bel£ lWA98528 or deco y, m [55 i er,ed �7 0 16 Drain P i e.�d to 3� 9 Qbavt donerl Ja-u� CeNTe"t BDX W�i.zS�final W1WE5 ��"�� " � 21T4anfsPeRt t.INe 3° 4D BLS 0 30N 25 t. 25" f[EVER UIJE5 0 25 3 o ,4PPROV Ste_ MAsoNocrog 0?y F� __ ti.zs " care4s+�5 D s o S 20 ry D�fA NMfNTA(HfA(T � r' "'�u� • �-Cry'°" Dr��. -eS �ekd�'L Ill.�eti.-�c' 1 NOW (r ms,,h'rm i fatm for L Y"t) O_Ot w fMpart-mbe4"wM In -f.L5"ls+f^+a I PVC Frye from top ofing?b%or to fmished . 3�C ` q'' gadD. Armlov+bte Saew�lobsw4AMP0d ebxn'�P s SO dw colt be Jaooved. QS�wjF, mom imma of so they I Mhl®weofo acwb%v system- I:merels are mber�tertd mvenches. `z + d.—SCREW ON CAP 45 DEGREE ELBOW OR T"ERALSWEEPING 9U END OF d DITCH DETAIL. CLEAN OV2 �. NOTE, CLEANOUT TO BE 'FROM 0 TO 6 a ." INCHES BELOW FINISHED GRADE. MARK ENDS WITH REBAR- .CLEAN OUT REQUIRED AT END OF EACH LATERAL-' 510 349 V . PAULA JOY JOHNSON'. ZS �5 Ord 6v O.C.(5 Orl im) 30"firm Memfold q 24'fr®Emow EIDow 6'fiomEod of7tmcbfBrd Length Length Orifice # Distance from T Lateral# In. FL S acin Orifices Feeder Line In. i 300 25 60 5 30 2 300 25 60 5 3 30 0 3 300 25 60 5 30 4 300 25 60 5 30 Total Lateral Len N 100 Total#Orifices 20 GPM= 17.8 A Dynamic Head Calculations •A/j� Selected residual pressure'. 2 R. O,, II Length (Ft.) #Orifices ��SCN OOjO v�Q Transport Pipe 80 20 0.22 "64 y 9707y Feeder Total F,yy(RO Lateral Line Length D1 �114 Lateral#2 25 7 32 5 0.05 ft. q TA(HFA( , Lateral#3 25 12 37 5 0.06 ft. Lateral#4 25 17 42 5 0.08 ft. Total Elevation Lift 6.00 ft. Total Dynamic Head 7'43 ft. SECURED LID LVRH a"TIGHT SEAL THREADED UHIOM u.DtAVErERk ACCESS RtM r SERVICE j VALVE FiNISH GRADE - -- r_-.—.Tn rxwNElElo PROP 6EPDO TAM BMRgemm STORAGE 1 ANTI SIPHON VANE• HIGH WATER AlAM LEVEL `— owowwEaT A "consul. �- WORKING VOLUME 1 FLOT STEIN FOR FI.QAT WOU rm ENCLOSED (� E VALVE ttEDIYENT SHROUD i. _ c PULP CENTANIFUGAL ego 3" PUMP t.HAMBEH cAVLA JOY JONNSON•. QYPICAL-1 - '~ . . lOESIGNEp" 'AB NEEDED WAC chapter 246-272C and '"NEEDFIGURE 2 Septic Tanks must eet standards required by P ttlanufacrurer must be on Dept of Health list of registered sewage tanks. 5 W A rxL puell eden 0337-022 Page 35 of65 - 7 B,nm combucdon available(139 series) High head version available(145 series) Double shah sealversions available for added proms om on models 140/145. Flow-Mate For moreinforma on,see Technical Dom5heets FM2282 FM2783. In high head dewatering or effluent applications where pumping oe performance is critical, this robust r family of pumps is known for reliability, durability and performance. These I pumps are especially suited for harsh environmems.Zoellelscoolrun design and corrosion-resistant,powder coated epoxy finish add up to a long-lasting, trouble-free product APPLICATIONS`: a • STEP or.nsite applications y Watertransfer 9 Light cummercia l dewatering BPECIFICATIDNB: 1-1/Y NPT discharge �S 1/2 HP through 1 HP MADE IN THE USA Available in aVtomatc or nonautomatic NnRMWEYlnnitll • Motlel i37,139,140:1/2"(12 mm)s,hancal solids - capacity with vamaelmpeUer • e Model 145:3/4"119 mm)spherical solids capacity with Immocimpeller PUMPPEH CECUHVE MODE 151/1 71163 DOSe-Mate oft Coll"fKT m This is our fastest growing line of effluent to w pumps.The 150 series istrulya workhorse designed for reliability under extreme Is m conditions in an effluent environment. 99 250 Series pump curves cover a wide range g ss of applications. They are weU suited to 7� w applications with low pressure pipe(LPP) $i a to IaI and enhanced Row STEP systems.Zoeller's cool run design and corrosion-resistant a m powder coated epoxy finish, in addition to the hermetically sealed,oil-filled motor Ia and non-clogging vortex impeller add up to a long-lasting,trouble-free product 1p APPLICATIONS: STEP or onsite applications ° M1MADoE I1NN lMEIU1ff1A1 Io N m m )a as N Im Light commercialdewatering iaEUIIHNLLOBHI W.OW o e a avennewnoxa: m Hwv rtx vyn,m 1-1/2•NPT discharge • 3110HP through L2HP � pA AvaiMble in nonautomatic or wldl a variable level piggyback mechanical switch O� 212-(12 mm)sphedul solos capacty won vortex ine eaer For mom information,see Technical Data 5heet FM2784. M�SCNCC((��������0� `�Op -O 0 Atirigho;reserved. 20ELLFR PUMP f0. 1502-TTB-27311800928-188TjteTpe�rpul m 9 ��OM1M1'✓A NMFNTAIH�III,° S-r puALIroRrAlauloR-� i WATERM+M LM`/ENT lh91 � 1 ' RISERS(rTPI 1•wG/1Yi') N w I µiSTIC � I r( PUN0 S. # &REDUCER 1 rm ,•wCSWDSE iIT RENRN LINE rwc DIGESTER CNAMBER CLARiIER III 'I TRABNCNABBER pPEtunNG CAPACITY.all Gn fa!l OMMUR C,,XNG GPACRY,V1 LONE FLCCiD FAC`4"G "3 1W(YLLCNa F,.aop D,RAcrtr.ampw.pNa II Ftpar le,wLi i IAT A A '� 1EE A I Ro� ,r �1 OCTO �® •••DlFNSERSiRe RI N IN�O� ` �O�/, PARALELTOTMKWALL A. ry! 7 } ELIAGE NENRN I Y 1£TIP®1 STpNEFREE NATIVE SOIL OR COMPACTED SAND OVER STONY SOIL INSTAl1AT10N MBINUCTNINB 1)Excavate tank hole Wdh WhiCel Wells W 1 foot al Than Dank on all aides, as —^ 2)If bcnom of hale is stony,install r of compact sand!&final IL pat Wim weedz 3)Install tank in Darner Pf hole.kaeping 1 R wid space Onrall a des.4)Ae tank is fiking W W3Dar,ha in wid sPace Withdgranular(sandy)sdl hoe of large dumps ofay. 3affixrisestoadaptersm u-r 6) rho.6)Pedonn waterdghtrlms test in field as reguiretl bjurlsdiaion. tr LASER7)Upon approval,n batltfill parefally baldtfill wittl nMm Gfn Ci FRsailsovertopoftank. J 8)Final grads the sadeosa avoid Dhanelfng surface ----- WaterfowaMtank IDpNm r -zea AEROBIC TREATMENT TANK DETAIL FOR NuWA TER BNR-500 TREATMENT UNIT ENVIRO-FLO, INC. REUSED: 3101112 Wastewater Treelment Technologies P.O.BOX 321161,Fiowood.MS 39232 suuE: (877)83B 76 (601)Sd647161ax 1" _ 1.4 ft. e Nro- .net -J,1�ct t t�i Water u App� I MASON 00"0 \ cop 7r 910 4 N ENt' 1 014 NMFNrAC NBC NY l ! I \ TH I � I I PARTS LIST NuWater NR Assembly Diagram A DUAL PORTAERATCR M.POLY DIFFUSER MR(2, B.LPRUBBERN'W/CLAMPS(9) N 1-PVC(3 by SECTION) C.A'B"BARBED JIDA TI PTOR Q; O.1lK CLEAR P 6.trz^BtJPX 1IY NPTAOAPiOR P.tIC CLEAR PVC HOSE(OPTIONRL S; P$IREE!X I?HFT SUM.NC(3) O.1/Y WC PIPE Ia,I ALLERI P.t?W'F.LEOW(3) R.1"WC PIPE(BV INSTALLER} G.t'X 1"X 1( TEE S?PVC Pin(By INSTALLER) H.1-90'ELBOW(3) T.Ifr BAREEO ADAPTOR TO 1Ic NPT 9) TXPBUSHING U.I?SMEETX IH'NPTe INQ R) J Y SANITARY TEE v In-PVC COUPLER m K.1'PVC CROW W Z WUMEA IBY INSTALLER} t"COUPL59(BY INSTALLER) ' Revised 2/25/12 8 &�9 Ox QXXOUL SCpfAC g- CO(SfL3, Jae. o � d � rt NuWater BNR Pretreatment INSTALLATION & MAINTENANCE ., } Pressure Distribution Systems ,✓ P�Ur�JOY JoMsomm LYC 1. Install Laterals with contour of the ground. 2. Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the draimock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions;any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals(cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue),after pressure test and Environmental Health Dept. approval,turn orifices down (6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10. Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,inn the filter fabric at least 2 inches down the trench wall. 11. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 12.Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area. 15.Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. I8. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19.All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning.Ensure anti-siphon hole sprays down/away from tank opening. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system,contact your septic installer to discuss setting up a schedule for your required Operation& Maintenance on your NuWater pretreatment system. APp ocTR�VFO 9 ?�24 MASONCOUNry �ROry A MFN744Nf447y