HomeMy WebLinkAboutBLD29334 Final SFR - BLD Permit / Conditions - 7/21/1992 TYPE RESIDENCE
Permit No. 29334 No. Floors 1 Sq Ftg 864
Owner pARADISE BUILDERS Tel 01 Date 10-18-91
Address pdE 22552 Hwy 3, Belfair Zip
Contractor Same
Address zip
ti
Legal Descripon Beards Cove Div 6 Lot
ll
Direction to project site down nort s ore to an i
1Pft on Tar.-,on Rd lot is on right
_� ec anica x ewer oo tove
Fireplace Deck x arage x arport
Basement —Loft Other
Shorelines: PlLmbing: c?/("6'/-9�
Setback: Mechanical:a< '
Special Interior:
Conditions: FINAL:. -1/
Mobile cmee
Smoke Detector.—r
Remarks:
Footing:
Setback:
Foundati 9
Walls:
Framing:0 6-/-9z
Fireplace:
Wood Stove:
BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584 �� I
427-9670 DATE ISSUED
PERMIT NO.
OWNER NAME MAILADDRESS CITY&STATE ZIP PHONE
r �• Ater, r - D
DIRECTIONS
TO JOB SITE oy4l
PARCEL LEGAL
NUMBER rp? %D 613OW& DESCR. IeFi
NAME MAILADDRESS CITY&STATE LICENSE NO. ZIP PHONE
CONTRACTOR �1 .e 6 Icy S*zr1 e- FIw
USE
BUILDING Q /v
CLASS OF NEW ADDITION ALTERATION TREPAIR MOVE REMOVE
WORK ✓
DESCRIBE
WORK
S �•
BEDROOMS DECKS 'f CARPORT NOTICE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
BATHROOMS TOTAL SQ.FT. � GARAGE CONDITIONING.
NO.OF STORIES f�= BASEMENT ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
t�/,� COMMENCED WITHIN 180 SAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
TOTAL SQ.FT. FIREPLACE DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.
PERMANENT SHORELINE
SEASONAL
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING
OBTAINING APPROV FROM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT.
X OW DATE 4:�1' X B ATE
FOR OFFICE L145E ONLY
APPROVED APPROVED BUILDING VALUATION
DEPARTMENT DEPARTMENT r e v
YES NO YES NO > 1 :2
HEALTH PUBLIC WORKS FEE
PLANNING FIRE BUILDING PERMIT
D.O.T. BUILDING PLAN CHECK IVA
SPECIAL CONDITIONS BUILDING GROUP PRE-INSPECTION
SHORELINE
WOODSTOVE A -
PLUMBING �—
—
MECHANICAL
STATE BUILDING FEE r
-ST-All:SI IRGHABGP
APPLICATION ACCEPTED BY I PLANS CH CK BY APPROVED FOR ISSUANCE PERMIT VALIDATION
1 0w3 1
1 J BY CASH CK "MO TOTAL /�,_�
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
426 W.CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584
427-9670 DATE ISSUED
PERMIT NO.
OWNER AME MAILADDRESS CITY&STATE ZIP PHONE
c /U
DIRECTIONS 7y
TO JOB SITE 6 N !/L A-
leP`l`3 '
LEGAL I �r /
DESCR. (�l
CONTRACTOR 'ME MAILADDRESS CITY BSTATE I,ICEtjSE NO. ZIP PHONE
_ k4fA /h
USE OF
BUILDING
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
WATER CLOSETS 4j, FORCED-AIR/GRAVITY TYPE FURNACE 6.00
BASINS 1Y FLOOR/SUSPENDED FURNACE 6.00
BATH TUBS BOILER/COMPRESSOR 6.00
SHOWERS REPAIR/ALTERATION 6.00
WATER HEATERS - REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER AIR HANDLING UNITS 7.50
SINKS HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT 6'
LAUNDRY TRAYS FIRE SUPPRESSION 5.00
CONNECT TO CITY SEWER WOOD FURNACE 5.00
DISHWASHER
DISPOSAL 1!
URINALS
PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00
TOTAL TOTAL 16 OV
SPECIAL CONDITIONS: _- NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CONFORMAN E THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRS T IN A ROM THE BUILDING DEPART NT. WITHO RS B� P VAL FROM THE BUILDING DEPARTM T.
X OW _DATE �� � X Y DATE
FOR OFFICE SE ONLY
APPLICATION�CCEPTED BY PIAy ECK B BUILDI GP / APPROVED FOR ISSUANCE PERMIT VALIDATION
T��j/ ail B m+l IBY CASH CK MO
BUILDING PERMIT PLOT PLAN
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. Box 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED
PERMIT NO.
ME
OWNER AIL ADDRESS CITY&STATE ZIP PHONE
DIRECTIONS
TO JOB SITE
PARCEL LEGAL
NUMBER DESCR. (�
Indicate below: O Property lines and dimensions.
O Easements and roads.
O Septic, drainfield and reserve area, or sewer.
O Septic tank and drainfield setback distances from foundations.
0 O Location of proposed construction on property.
O Building& septic system setback distances from all property lines& easements.
Indicate North O Well and water line.
In Circle O Saltwater, lakes, rivers, streams,wetlands, drainage.
O Attach copy of septic system"as built" or septic permit approval.
O Indicate topography profile of property and structure on reverse side.
I
I/We certify that the proposed construction will conform to the dimensions and uses shown above and that no changes will be made without first obtaining approval.
SIGNATURE OF OWNER(S)OR AUTHORIZED REPRESENTATIVE
DO NOT WRITE BELOW THIS LINE
APPROVED
DISTRICT AS NOTED DATE
TOPOGRAPHY PROFILE OF PROPERTY AND LOCATION OF STRUCTURE
JL
i
T r*3UN 5 . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 10/01/91
i'ILE: B:SGC1294 .WS HOUSE ID: SGC1294
Site: BEARD' S COVE DIV 6, LOT 61 Analyst: DEBBERA CORER
BELFAIR, WA Jurisdiction: MASON COUNTY
Utility: MASON COUNTY PUD #3
Homeowner: SAME AS BUILDER
Mail : Floor Area: 868 ft2
Builder: PARADISE BUILDERS Weather Data: Olympia, WA
Address: NE 22553 HIGHWAY 3 Climate Zone: 1
0 '
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. ;
REFERENCE PROPOSED '
' COMPONENT PERFORMANCE 166 166 Btu/hr-F '
' ENERGY BUDGET 2 .23 2 .25 kWh/ft2-yr ;
REFERENCE DESIGN
Reference
Component Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Floor U-0.029 868 25.2
Glazing @15% U-0. 400 130 .2 52 . 1
Doors U-0.200 40 .0 8.0
AG Wall U-0.058 932 54 .0
Ceiling U-0.031 868 26 . 9
Infiltration - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Reference UA 166
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Floor R30 vented Joist 16oc U-0.029 806 23 . 4
**STAIR/LANDING R19 U-0.041 62 2 .5
Glazing @15% **NORTHWEST ALUMINUM - X/O WITH ARGON U-0.390 93 .0 36 .3
**N.W. ALUM VINYL- PATIO W/ARGON U-0.480 35 .0 16 .8
Doors Metal 1 -3/4" urethane flush U-0. 140 21 .0 2 .9
Wood 1 -3/8" solid flush U-0.390 19 .0 7 .4
AG Wall R21 INT T1 -11 U-0.056 900 50 .4
R11 STD T1 - 11 U-0.094 34 3 .2
Ceiling R49 blown Attic STD baffled U-0.027 868 23 .4
Infiltration Standard Air Sealing ACH-0. 350 6944ft3 ( 44 . 5)
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Proposed UA 166
---------------------------
Items in parentheses not included in COMPONENT PERFORMANCE totals.
** Denotes non-standard values - check calculation of thermal value.
Page 1
'f`ijj�SUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 10/01/91
FILE: B:SGC1294 .WS HOUSE ID: SGC1294
--------------------------------------------
Struc Mass Light Frame, Sheetrock walls M-3 . 000 868 2604 .0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Electric: Zoned
Make:
Model:
System Efficiency: 100 %
Modified Efficiency: 100 %
Heating Load(at 53F dt) : 12858 Btu/hr
System Size: 3 .8 kW
Maximum Size @150%: 5. 7 kW
Average Annual Heat: 2826 kwh
Annual Cost: $ 155
Ventilation Type: Non-Heat Recovery
Option: Option 1
Cooling Load(at 5F dt) : 13641 Btu/hr
Recommended Size @125%: 1 .6 tons
Solar Access: Partially Shaded
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
GLAZING ORIENTATION
PROPOSED PROPOSED
South: 32 .0 ft2 North: 32 .0 ft2
Southeast: 0.0 Northwest: 0. 0
East: 32 .0 West: 32 .0
Northeast: 0.0 Southwest: 0.0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
------------------------------------------
Economic and energy consumption estimates are designed for comparative
purposes only. Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors.
------------------------------------- Page 2 -----------------------------------