Loading...
HomeMy WebLinkAboutBLD2007-01767 Final Attach Garage DDR2007-00305 - BLD Permit / Conditions - 1/7/2010 F �� MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 i� RESIDENTIAL BUILDING PERMIT BLD2007-01767 OWNER: CHRIS ARCHAMBEAU CONTRACTOR: LICENSE: EXP: RECEIVED: 10/4/2007 SITE ADDRESS: 760 NE LARSON BLVD BELFAIR ISSUED: 10/25/2007 PARCEL NUMBER: 123305300063 EXPIRES: 4/25/2008 LEGAL DESCRIPTION: BEARDS COVE DIV 6 BLK: LOT: 63 PROJECT DESCRIPTION: DIRECTIONS TO SITE: ATTACH GARAGE TO EXISTING SINGLE FAMILY RESIDENCE. NORTH SHORE LEFT ON SANDHILL RIGHT ON LARSON BLVD. ACROSS FROM SALTY DRIVE. General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: ACC Fire Dist.: 2 No.of Stories: Occ. Load: Building: Valuation: IL Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 3 1.0 Ft. Shoreline: Ft. Water Body: Rear: N 33.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 5.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee CMH 10/4/2007 $163.31 B12007000 Planning Review Fee CMH 10/4/2007 $170.00 612007000 Building State Fee TFR 10/16/200 $4.50 S22007000 Building Permit Fee TFR 10/16/200 $251.25 S22007000 EH Plan Review ADR 10/19/200 $35.00 S22007000 Total $624.06 BLD2007-01767 Please referto the following pages for conditions of this permit. 1 of 4 r— Ali� CASE NOTES FOR BLD2007-01767 CONDITIONS FOR BLD2007-01767 1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X ,4 C. 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X ( 4-. 3) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. 4) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be applied for, reviewed and approved prior to the change. X 5) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X li_ '1 6) Per 2003 IRC - SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH. X r,, l=+ 7) Per 2003 IRC -SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions. X 8) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X_" . BLD2007-01767 Please referto the following pages for conditions of this permit. 2 of 4 i A 1 9) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X C i-= 10) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit,revq�;ation. X 11) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X C_ ►"l� - 12) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X I.-, 13) All property lines shall be clearly identified at the time of foundation inspection. X 14) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X 15) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. x 16) Water.quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X L" - L_ 17) Prior to final approval, all upland areas disturbed or newly.created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X Y-i 18) Approved er dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X `d , 19) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your Approved, ite Plan"to ensure these structures are shown and meet the setback conditions listed. X BLD2007-01767 Please refer to the following pages for conditions of this permit. 3 of 4 20) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X 21) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X / This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and i ction. OWNER OR AGENT: DATE: / y BLD2007-01767 Please referto the following pages for conditions of this permit. 4 Of 4 o CONCRETE MECHANICAL MANUFACTURED HOME � o Date By n oV Footings I Setbacks Ribbons = Gas Piping D o Interior Date By Interior-Date By Date B 03 d Exterior Date y_ 03 0) � 0) Z-G-0 r By�60 Exterior-Date B Set-up nl Point Load f Isolated Footings INSULATION Date By D BG I SLAB INSULATION C Date By Data By FIRE DEPARTMENT _ n Foundation Walls Floors Date By = Date By Data By DECKS C FRAMING Wells Date By pate Af B Data By PROPANE TANKS PLUMBING Vault Data By Date By �- OTHER Groundwork Attic Date By Type Dale By Date By MW.V DRYWALL Type_ Int Brace Wall Date By W Date By Dxte 13y FINAL INSPECTION v Water Line Fire Separation --> IVCD I6 Date By Date By Date By O m V Pass or Request Inspect. o 0 Ty of Insp- Fail Date Date Done By Comments rn a S 0 Zn ic- 7 7-o 1 7 //? 4-, Wle CD y 0 E r i e f e i f f t �a UR K—J'—tl-� __4 f i i t TOPOGRAPHY PROFILE: APPROVED MASON COUNTY DCD PLANNING SITEIPLANJOEQUIRED TO BE ON SITE CH"SUBJECT TO APPROVAL Ddte Direction: Scale: Approval: for office use Building Permit number: Building: Owner/Applicant: Date of Planning: Parcel Number: application: Env. Health: MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICA T INFORMA ON CONTRACTOR INFORMATION Owner Company Name Maili A d ss C Mailing Address City i—State WA Zip Code City State Zip Code Phone ther Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic.# ~ DOB Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic E istin Septic Connect to Water System _Name of Water System Well ,Sewer SysteraL� Name of Sewer Syste blic PARCEL INFORMATION - 12 Digit Parcel No. Fire District �`�L i Legal Description Site Address (Please include street name, street number and city) Directio s to site ' '" t", f Will timber be cut and sold in parcel preparation?Yes/ Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluff/o Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/N—o`) TYPE OF JOB - New vl Add ' Alt Repair Other PRIMARY RESIDENCE &SEASONAL ❑ Use of Building na�'�- —Describe Work 1�� �9 &o .. n No. of Bedrooms No. of Bathrooms Square Footage-.1 st Floor 2nd Floor 3rd Floor Basement. eck Covered Deck Other Sq. ft. Garage Attached c�_ Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTIRUATION OF WORK IS BY MEANS QFAPROGRESS INS ECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATPTHEAPPLICATION. X er Date: " ` 07 ti wrier wners Representative/Contractor (indicate which one) OCT FOR OFFICIAL USE BEYOND THIS POINT Accepted by: pate DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department _ Planning Department Environmental Health Department I � Fire Marshal FEES Building Permit Fee 2s/.LS' Site Inspection Plan Review Fee 1,T f 63- 3 / EH Review Fee Plumbing & Base Fee C>— Planning Review Fee O - Mechanical & Base fee Other Wood/Gas/ Pellet Stove Fee State Fee -� Violation Fee 'o -'3--`'� © -- Pre-Paid at Submittal Valuation $ >17 r'(�_tXJ TOTAL FEES ! 1 z La �� � Miggy OUNTY OCT MENT OF COMMUNITY DEVELOPMENT 4 1001 1 F' h Street/P.O. Box 186, Shelton WA 98584 a �2 .9670 ext. 352 DDR -� OFFECE C� Qj Rec'd by �O Q� Request for Q Administrative Variance for Reduction in the Required Setbacks ($100.00) For administrative review, the minimum variance on a setback request is 5 feet from the side yard lot lines and 10 feet for front and rear lot lines or any access easement. Request for further reduction requires a standard variance. Setbacks are measured from the furthest projection of the structure, including roof eaves. Applicant/Owners: i Mailing Address: ` Aoo NE C,ae- D n (3h)d Telephone 275 F So City: &'I:�A( r State: L.-�14 Zip: R'572g? If this reduction is tied to a building permit, please give permit case number. BLD Parcel Number(s): I_2-.3-3©,5-3 Zoning Site Address: :71&? != Lat Ztnn Uc� r Requested variance: Front/ Rear Side Yard (please circle all that apply) Requested setback variance: 5 ft. An illustrated site plan is required. 0 o m Your site plan must show the following: north arrow, abutting street or rn easements, set backs to all property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and driveway. Show all proposed new development. The following circumstances must apply: FRONT AND OR REAR YARD REQUIREMENTS: 1) Existing lots of record as of March 5, 2002; You must meet one of the following: (Please circle all that apply) 2) One of the following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c) lot width at the front yard line of no more than 50 feet; d) lot size of no more than one-fourth acre; e) existing improvements of buildings, septic systems, and well areas. I:\PLANNING\PAC\VARIANCES\Adminstrative.var.doc Created on 04/27/07 12:51 PM SIDE YARD REQUIREMENTS: 1) Existing lots of record as of March 5, 2002; You must meet one of the following. (Please circle all that apply) 2) One of the following exists on the lot: a) steep slopes, wetlands, or streams present; b) soils that restrict building or septic development; c lot width at the front yard line of no more than 50 feet; lot size of no more than one-half acre; e) existing improvements of buildings, septic systems, and well areas. Explain how these circumstances preclude a reasonable development proposal from meeting the setback standard for Rural Residential 2.5, 5, 10, or 20 zones. �C)LASe �5 r Cos< +-o p roPerA-X ode o h "se Owner/Agent (please indicate) Signature and date Official Use Onl y I, Approved Date 0 t 1--D Denied Date Reason for denial: I:\PLANNING\PAC\VARIANCES\Adminstrative.var.doc Created on 04/27/07 12:51 PM MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST Owner's Name: L_ f) l A Date: W U Reviewed By: C t' y Documents: t/' Building Permit Application Completed Vlanning Intake Checklist Completed, ite plan includes:Allowable building area,roof ov gs,decks,etc. :L--fire Apparatus Access Road info required? Yes/ o V�En y Code Application Form-O Electric wall ater O Electric central furnace O LPG Furnace Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type_ O Other:Specify: Mechanical/Plumbing Application-WATER HEATERIfiEL TYPE Engineering? Ye (Need 2 sets of calculations)No _ Geotechnical report or assessment? Yes No Snow load: Zone(circle one): D1 or D2 Construction Plans:_3 COMPLETE SETS ,""Plans Legible ✓Recognized Scale vation Views ''Cross Section Ul oundation Plan _ oof Framing Plan �Floor Plan-Use of rooms noted(all floor levels) deer-Fuming Plan-all floor levels represented? Loft,crawlspace,etc. Beek-Framing Plan,including covered.porch framing Plan Details: —4-nt S Roof framing details,truss lay-out may be needed,truss or stick framed? all Framing-Does bearing-wall height exceed 10'?(Engineering maybe required) dung: Floor joists: Floo ams: Window headers marked on plans: Typical header: C Foundation:footing size,reinforcement _-Geaerete Walls-Does Concrete Wall Height Exceed '?(Engineering may be required) Landings at all exits? Less than 30"above grade? LYE)/ N Heated Byrace-Location of Furnace _FhrVtffC-e7Stove Information Shown-Fuel Type? Location(s): 'Window Sizes Marked on Plans Braced wall panels(shear walls)marked on plans or lateral engineering? (Plans may not be approved if not provided.) 2-Story Garage? (Engineering may be required) R602.10.1, 1"story of a two-story D1-45%,D2-55% C MMENTS: ENGINEERING REQUIRED: Braced wall panels/braced wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 IRREGULAR BUILDINGS(Irregular Shape)R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3) End of BWP extends more than 1 ft.over an opening more than 8 ft in width below. 4) Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5) Portions of floor level are offset vertically 6) Shear wall lines do not occur in two perpendicular directions. 7) When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed. In accordance with accepted engineering practice. DESIGN CRITERIA: Wind 85 mph exp B(unless proven otherwise), Seismic Zone: , Snow: psf 2003 1RC Plans submittal checklist simplified/WORD