Loading...
HomeMy WebLinkAboutBLD29468 Final SFR - BLD Permit / Conditions - 2/13/1992 Shorelines: ✓�, %/� 64,0&Kd dm Plumbing: _ Setback: MechanicaW i:o(2 'n, Special Interior: —�j(-,9 Conditions: Final: ,g- 3,oa rat Mobile Home: Smoke Detector Remarks: '� Footing: c: ' Setback: Foundation Walls: Framing: 6,r/ Fireplace: Woodstove: AREA: TYPE: RESIDENCE Owner: SOLTIS, BOB Tel: 275-4477 Date: 11-04-91 Address: P.O. BOX 767 BELF AIR Permit #: 29468 Floors: 1 Sq Ft: 1232 Contractor: SELF Address: Legal Description: BEARDS COVE DIV 5 LOT 80 Direction to job site: NE 1352 LARSON LAKE BLVD, BELFAIR Plumbing X Mechanical X Woodstove Fireplace Deck Garage X Carport P Basement Loft Conditions: CONDITIO N PAGE SIGNED el� 90 BUI ING PERMIT APPLICATION s4vC q MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 �` ✓ ' G� - 427-9670 DATE ISSUED PERMIT NO. Cr L N �i MAILADDRESS CIT BSTAT ZIP PHONE OWNER /ems I"U 762 4 W40P =`0 7 DIRECTIONS TO JOB SITE PARCEL LEGAL NUMBER �.,Z �� ;� DESCR. NAME MAIL ADDRESS CITY&STATE LICENSE NO. ZIP PHONE CONTRACTOR USE BUILDING Jtr/ CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE WORK ✓ DESCRIBE WORK �J BEDROOMS DECKS CARPORT NOTICE SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR BATHROOMS TOTALSQ.FT. GARAGE CONDITIONING. NO.OF STORIES BASEMENT ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR TOTAL SQ. FT. FIREPLACE DETACHED A10 ABANDONED FOR A PERIOD OF180 DAYS AT ANY TIME AFTER WORK ISCOMMENCED. PERMANENT SHORELINE SEASONAL OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONFORMANCE THEREWITH. NO C NGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAINING APPROVAL FROM THE BUIL DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT. X OWNER DATE X BY DATE FOR OFFICE USE ONLY DEPARTMENT YESPPROVENo DEPARTMENT YESPPROVENO BUILDING VALUATION HEALTH PUBLIC WORKS FEE PLANNING FIRE BUILDING PERMIT D.O.T. BUILDING PLAN CHECK SPECIAL CONDITIONS BUILDING GROUP —�~ � PRE-INSPECTION SHORELINE GV S S WOODSTOVE PLUMBING MECHANICAL STATE BUILDING FEE Z As STATESURCHARGE APPLICATION ACCEPTED BY PLANS CHECK BY APPRO DFISSU N E PERMIT VALIDATION 'BY CASH CK MO TOTAL 1 PLUMBING & MECHANICAL PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED PERMIT NO. OWNER N ME MAILADDRESS CITY&STATE ZIP PHON 76 7 -2 7 DIRECTIONS TO JOB SITE LEGAL / DESCR. CONTRACTOR NAME MAILADDRESS "CITY&STATE LICENSE NO. ZIP PHONE USE OF BUILDING 171d -� PLUMBING FIXTURES MECHANICAL FIXTURES NO. 2.00 PER FIXTURE OR TRAP FE NO. TYPE OF FIXTURE FEE WATER CLOSETS FORCED-AIR/GRAVITY TYPE FURNACE 6.00 D BASINS FLOOR/SUSPENDED FURNACE 6.00 p!� BATHTUBS BOILER/COMPRESSOR 6.00 SHOWERS REPAIR/ALTERATION 6.00 WATER HEATERS REFRIGERATION COMPRESSOR SYSTEM 6.00 AUTO.WASHER AIR HANDLING UNITS 7.50 SINKS HEAT-PUMPS 6.00 FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT LAUNDRY TRAYS WOOD STOVES 5.00 CONNECT TO CITY SEWER WOOD FURNACE 5.00 DISH WASHER DISPOSAL URINALS PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00 TOTAL TOTAL SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN CONFOR CE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST OBTA14ING APPR L FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. X OWNER DATE X BY DATE FOR OFFICE USE ON APPLICATION ACC PTED BY PLANS CHECK BY BUILDING GROUP A ED F SSUA C PERMIT VALIDATION ��/� IO 17 �I '/ BY CASH CK MO WAT'TSUN 5 . 1 1991 ' STATE ENERGY CODE COMPLII 'E REPORT 10/11 /91 FILE: B:SGC1307 .WS HOUSE ID: SGC1307 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Site: BEARDS COVE Analyst: BELLY BUECHEL SHELTON, WA Jurisdiction: MASON COUNTY Utility: MASON COUNTY PUD#3 Homeowner: BOB SOLTIS Mail : Floor Area: 1232 ft2 Builder: BOB SOLTIS Weather Data: Olympia, WA Address : Climate Zone: 1 ------------------------------------------------------------------------------ i The PROPOSED design Q*C?MPL­_IES*,with 1991 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 250 248 Btu/hr-F ENERGY BUDGET 3 .80 3 .96 kWh/ft2-yr ; i REFERENCE DESIGN Reference Component Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - On Grade Slab F-0.540 144ft 77 . 8 Glazing @15% U-0.400 184 .8 73 . 9 Doors U-0.200 42 . 0 8.4 AG Wall U-0.058 889 51 . 6 Ceiling U-0.031 1232 38. 2 Infiltration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Reference UA 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - On Grade Slab RO Uninsulated F-0. 730 144ft 105 . 1 Glazing @11% **NW ALUM VINYL XO LOWE U-0. 310 95 .0 29 .5 **NW ALUM VINYL PATIO W/AR U-0. 480 42 .0 20 . 2 Doors Metal 1 -3/4" urethane flush U-0. 140 42 .0 5 .9 AG Wall R21 ADV T1 - 11 U-0.053 937 49 . 7 Ceiling R38 blown Attic STD baffled U-0.031 1232 38 . 2 Infiltration Standard Air Sealing ACH-0 . 350 9548ft3 ( 61 . 2) - - - - - - - - - - - - - - - - - - - - - - - - - - - - Proposed UA 248 Struc Mass Slab w/carpet w/pad, Sheetrock wall M-5. 000 1232 6160.0 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Items in parentheses not included in COMPONENT PERFORMANCE totals . ** Denotes non-standard values - check calculation of thermal value. Page 1 WATTSUN 5. 1 1991 D"A STATE ENERGY CODE COMPLIANrE REPORT 10/11 /91 FILE: B:SGC1307 .WS HOUSE ID: SGC1307 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Electric: Zoned Make Model: System Efficiency: 100 % Modified Efficiency: 100 $ Heating Load(at 53F dt) : 18725 Btu/hr System Size: 5 . 5 kW Maximum Size @150%: 8 .2 kW Average Annual Heat: 7080 kwh Annual Cost: $ 319 _ Ventilation Type: Non-Heat Recovery Option: Option 1 Cooling Load(at 5F dt) : 14742 Btu/hr Recommended Size @125%: 1 . 7 tons Solar Access: Partially Shaded - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - GLAZING ORIENTATION PROPOSED PROPOSED South: 34 .2 ft2 North: 34 .2 ft2 Southeast: 0.0 Northwest: 0.0 East: 34.2 West: 34 .2 Northeast: 0.0 Southwest: 0 .0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----------------- Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors . Page 2