HomeMy WebLinkAboutBLD2022-00951 SFR - BLD Inspections - 10/22/2024 y, •tom, .� _,► S 615 W.Alder St.Bldg 8,SHELTON,WA 98684 MASON COUNTY SHELTON:360-427-9670,EXT 352 COMMUNITY SERVICES BELFAIR:360-276-4467,EXT 352 Puddtn%Planning,EnvuonmentelHealth;CommunlryHeaiah. ELMA•360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.usicommunity-services/bld-inspection.php Permit Number BLD2022-00951 Date Issued 11/08/2022 Issued By Project NEW SFR Site Address 620 SE SNIDER RD Applicant ADAMS ET AL KARL WAYNE Contractor Contractor Phone Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -� -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. Q -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. (� "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee .� Concrete Setbacks - Slab Q., Footing Perimeter - 74 Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Wall Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping hear Wall Nailing UnderFloo S Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls /Q.M 'D 9 Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other -- - Final Building-?3• �Eb Manufactured Setbacks Setup Home Concrete Foot/Runners Final r Other Arc- L(-aS-a3 VE,� se �/V\- ��- \O Cs" Fd S FqItL 5-1-23 DIE-9 see- 0 i e r let�cr_ 4�. S recwo�, S�'�rcl� i��aco �L a..c ��0 ulna � tY c r n��a 40D MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Be lm ext.352 360-482-5269 Elxna ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: -3 LD as:)2- Od R§ ADDRESS/LOCATION: 6;?o acR f1D FINDINGS: L 0of S fn ri r,�n� r4 e— 4o Ae. oq k Poo 4�+� S NJ i 6*f na4rt -ni l�. yr ..41 o.N (cck c-ru.sl.4 (be,lt Items listed above must be corrected to Gain compliance. ,THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and-the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections,items will be checked on the next inspection. OK to Date: %2.s-z ❑ Please contact our office regarding possible Department: 2AMP structural damage incurred by recent ~� IT made"disasters.This is NOT a Inspector: DE CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 L MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 360- Belfair ext.352 360-482-0-482-5269 Elora ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 9P ao22 "OOaS I ADDRESS/LOCATION: SE SAD la s? R D FINDINGS: S,gAn�> pNcmQf ]b 'DdZ�'off 1, tWcWCnuU7YWA,Coil, Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. OK to ,5EL)D il�}d't OC Date: q-a 3 ❑ Please contact our office regarding possible Department: 'BO structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 ' MASON COUNTY 360-427-9670 Shelton ext.352 . COMMUNITY SERVICES 360-0-482- 2 Be lm ext.352 • 360-482-5269 Elma ext.352 e Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER eSLQ;),'� ADDRESS/LOCATION:� 1�) .1::W\ FINDINGS: . � 'B 2° C o i Ulf vto �— CO 1 QS.Irc. chi -," TACWIS. 01, k Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. call for re-inspection when corrections are made before proceeding with any further work. /—❑ flake corrections, items will be checked on the next inspection. ❑ OK to Date: Please contact our office regarding possible Department: C, structural damage incurred by recent Inspector: �� y{ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 360-275-4467 Belfair ext.352 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: ! Q ADDRESS/LOCATION: (Aer V4,6 FINDINGS: Oxen Le �� ee r� e r cY •, S ex oor- C r r Items listed above must be corrected to zain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. all for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections,items will be checked on the next inspection. ❑ OK to Date: `(��,Z-' 23 ❑ Please contact our office regarding possible Department: 1., structural damage incurred by recent "natural/man made"disasters.This is NOT a Inspector: 6►y� l)V'V C CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 r MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 360-0-482- 2 9 Ell r ext.352 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: Ob ---�> ZO 2-z—C)CR`,=-,s 1 ADDRESS/LOCATI N: W2-0 cat INDINGS'�C4 � S h ` 4 �O� Y Al � wo X-v Y n 1� r t Ir'VV-Vf:--V-t 0 k AJ WIN YS P e. \kj` Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. l for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to . Date: �'� •�2.' ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: �( �f "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC 14.12 MASON COUNTY 360-427-9670 Shelton ext.352 ` 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 802o12- 0012 ADDRESS/LOCATION: 4 se- sw a)e x RD FINDINGS: � 1 C%+ a�w4 er v�r i� ^ A A c� G. - inT{lcoa c�c �d e. oAtn �la� cJe/ cif re re l eltdt,cS I Fm EQJ.RED M a I n1 E • o er,4 code- c.,pla-da iv chi. a o -A 4 .rC. , d 14 ill T e •% r- ��,5® �y I PJvtAora^g O ccuys.�c� anc�"f'c� Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections,items will be checked on the next inspection. ❑ OK to Date: E] Please contact our office regarding possible Department: structural damage incurred by recent Inspector: D "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 3 0-275 360-485 69 Elma ext.s 52 Building,Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.goy CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: �Oa`1o��o2gS I ADDRESS/LOCATION: 920 SF SNIDER 92 FINDINGS: I, 40,WL ofewro>J I i1 ¢cr7 Ate 4 rie.---� /^ D/'e c� cCL IOW i.f ti'�n S -rro..� Cvbs;nQ�l . o Is 'IDAcy— e,Je 0 0^ I Items listed above must be corrected to 2aili compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. JW Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: 6�1^2,3 ❑ Please contact our office regarding possible Department: ALD structural damage incurred by recent Inspector: �Oep "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 Mason County Mason County - Division of Community Development 1 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us FBD2-00951 NEW SINGLE FAMILY RESIDENCE ESCRIPTION: NEW SFR ISSUED: 11/08/2022 ESS: 620 SE SNIDER RD SHELTON EXPIRES: 05/07/2023 PARCEL: 320255000048 APPLICANT: ADAMS ET AL KARL WAYNE OWNER: ADAMS ET AL KARL WAYNE RACHEAL L ADAMS RACHEAL L ADAMS SHELTON,WA 98584 SHELTON,WA98584 1.206.947.2908 ARCHITECT: BROADVIEW HOME BUILDERS ENGINEER: BDGIDDINGS ENGINEERING 30 20TH AVE 10826 NE 108TH ST KIRKLAND,WA98033 KIRKLAND,WA98033 1.425.301.7286 1.425.218.3471 VALUATIONS: FEES: Paid Due Covered Deck/Carport 558.00 $12,276.00 Mechanical Base Fee $30.00 $0.00 R-3 VB Residential,one- 3117.00 $462,344.61 Building Permit Fee $3,578.00 $0.00 and two-family Plan Check Fee $2,325.70 $0.00 U VB Utility, miscellaneous 494.00 $29,580.72 Technology Surcharge $130.19 $0.00 Planning Review Fee $240.00 $0.00 State Fee-Residential $6.50 $0.00 Plumbing Base Fee $25.00 $0.00 Plumbing Fees $167.00 $0.00 Mechanical Fees $384.00 $0.00 Building Plan Review/Change of $125.00 $0.00 Use-Onsite Sewage Total: $504,201.33 Totals : $7,011.39 $0.00 FIXTURES Oty Mechanical Fixtures 0ty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Bath Tubs 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Clothes Washers 1.0000 Heat Pump(s) 1.0000 Number of Dishwashers Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 1 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 Oty Mechanical Fixtures Qty Plumbing Fixtures 1.0000 Propane Tank(s) 1.0000 Number of Kitchen Sinks 1.0000 Wood/Gas/Pellet Stove(s) 1.0000 Number of Water Heaters and or Vent 5.0000 Gas Outlet(s)(1-5) 2.0000 Number of Hose Bibs 6.0000 Spot Vent Fans) 2.0000 Number of Showers 6.0000 Ductless Heat Pump 4.0000 Number of Toilets 6.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Rough-Plumbing Inspection ...................................................... Footing Inspection Mechanical Inspection .... .-.. ................ ............. . ..... ..... ....-_----.._-..---- --. ,_ _ ,_. .� .... .-... _. -... ._ _ _ _ _..... _ _ _... ._.�. ... ._ _. ..- _ Foundation Wall-Pre-Pour Inspection Insulation Inspection ------------------------------------------------------ Underfloor Inspection Connection has been verified by Health or Utilities She- ---- Inspection _-------- -_-------- BLD-Final Inspection Framing Inspection ------------ CONDITIONS Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. _............................................................................................................. All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. .................................................................................................. ... * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. 'All property lines shall be clearly identified at the time of foundation inspection. ----_-_-.--. ------------------....._--_---_--_--_------_---------.--_.-__--_-----__------------------------------ * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. ------------------------------ ----------------------------------------------------------------- -------------- * Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi(IRC Table R402.2). .--- ---------------- ------ ----------- ------------------------------- .------------------------ * Pressure treated wood manufactured after January 1,2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 2 of 7 Mason County Mason County - Division of Community Development N , 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL Y i L INVALIDATE THE APPLICATION. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. _._.vo_____. _. . w....__._..n.w_,._,_.._e..............._____x_...___.r__.._____....... . * A permanent certificate, completed by the builder or registered design professional,shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building.When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect Iabek,or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls,foundation (slab, basement wall, crawlspace wall and/or floor),and ducts outside the conditioned spaces; U-factors for fenestration;and the solar heat gain coefficient(SHGC)of fenestration.Where there is more than one value for each component,the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment,,duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in %or'/2 sheets. _. _.__1-------------_-------.---------------------- ._._.._..._...._____.__a___._._______,------- .___.____.__._.__ * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will r -------------_..,___....._.._......__..._________.__.__.._._.________.____ * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 3 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur,or when one or more sleeping rooms are added or created. " The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. -------------------- ------------------------ . -_---_-_. . ___,-- Adopted Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C,Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49,Vault Insulation R-38, and Slab Insulation R-10. 2 Heat pump 1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by5% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to-3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present).Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.6 Ductless split system heat pumps with no electric resistance heating in the primary living areas.A ductless heat pump system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor air temperature. 5.5 Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 4 of 7 ' G "^^ Mason County r Mason County - Division of Community Development 615 W.het ne WA 918584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton.The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. ------------------------_----...._..____---_-.,___A____..__...._-___.------------------------------------ __-..___.___. A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design,sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have,a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the.septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ____..._..,__.....,._.__,...,_...__.,,..s....................... .............._....__a..__.,........ . .__.... * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. .__.._____________________..,_.____ __..__m__._.__....wm__....„. ..a__-----_.._____..______ * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 5 of 7 'G "Nw Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 • � Shelton,WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts,air handlers,filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space ------ -----. All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. .......................................... -----......-.. ----------------------------- - " Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner, agent for the_ owner or a registered contractor according to WA state law. All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. ..........................................................................................._.-........ ..., A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. _........................................_......,.__......_...-.....................__......------- ................ By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. ...-_................ . -----------..............------ - ----------------........_.................._......... Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. _...w........ ...................................-. ...............-........................._........... . . * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. Printed by:Genie Mcfadand on:11/08/2022 08:39 AM Page 6 of 7 G Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00951 * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ----------- ----- -------.-_..---_----- -------------- ---- ----- --------- ------- When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. .................... ------- _ --------.___--. All changes to"approved"building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. .. .............. ----------------------- --------------.........--------.-__.__-------------------------------- * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. -- ----------------------------------------------_--- ------_---------- . ------------------------- ------ * On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. ----------r--------------- ------_-. -------------- ----- * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. ' A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.)Septic tank(s)requires 5ft setback from all footing/foundations. C.) No foundation/Perimeter Drains within 30ft,down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. -- -- ----------- ----------------- ---- ------------------ ------------------------------- -------- ------- * New impervious surfaces and native vegetation clearing prohibited within 150 feet of creek ....................._._..........................__..................__......_........_..... * PLANNING SETBACKS Front:25' (measured from road only) Rear: 20' (west)or 165' measured from OHWM (east) Side: 20'(north and south) Measured from furthest projection Subject to EH setbacks . ..w---- ----------------------------------n.-------._.--_..._...-------------------------------------*.......... * Approved up to authorized heights of 35' measured from average grade at the midpoint of the building I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: w U--,/ Contractor or Authorize Agent: Date: 11- —LL Printed by:Genie Mcfarland on:11/08/2022 08:39 AM Page 7 of 7 Y �-�boa- aegsl MASON COUNTY COMMUNITY SERVICES II n Building,Planning.Environmental Health.Community Health These requirements apply to all IRC building types,including detached one-and two-family dwellings and multiple single-family dwellings(townhouses). Contact Information Project Information Ow ers N e: Site Address: Mailing ddress: W',`VL qp,�y Parcel Number: ! j _ D Square Feet(total): Ventilations Compliance: Nzrmhole House Ventilation system O Whole House Ventilation using exhaust fans&window or wall Integrated with a Forced Air fresh air vents(M1507.3.4) System(M1507.3.5) Other,describe: Instructions:This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. All Climate Zones(Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC bje n/a n/a Ceiling a 49 i 0.026 Wood Frame Wall 9.1 21 int 0.056 Floor 30 0.029 Below Grade Wall`" 10/15/21 int+TB 0.042 Slab d•f R-Value&Depth 10,2 ft n/a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. Prescriptive Path—Single Family 2018 Washington State Energy Code-R For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for g climate zone 5 of ICC 400. Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits)and Table 406.3(energy credits)to achieve the following minimum number of credits.To claim this credit,the building permit drawings shall specify the option selected and the maximum tested building air leakage and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit:3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit:6 credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit:7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table review the details in Table 406.3(Single Family),on page 4. Summary of Table R406.2 Heating Credits-select ONE Options Fuel Normalization Descriptions heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 3 Electric resistance heat only-furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits-select ONE Options Energy Credit Option Descriptions energy option from each p category 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 Li 1.3 Efficient Building Envelope 0.5 1.4 1 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ Prescriptive Path-Single Family 2018 Washington State Energy Code-R J u 4.1 High Efficiency HVAC Distribution System 0.5 4.2 High Efficiency HVAC Distribution System 1.0 ❑ 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating A.5 ❑ 6.1e Renewable Electric Energy(3 credits max) p 7.1 Appliance Package 0.5 ❑ Tota I Credits a. An alternative heating source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4)orC403.3.2(5) c. Equipment listed in Table C403.3.2(1)orC403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S.Option 5.1 may be combined with options 5.2 through 5.6.See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually,up to 3 creditsmax. See the complete Table R406.2 for all requirements and option descriptions. Please print only pages 1 through 3 of this worksheet for submission•to_your building official. Prescriptive Path—Single Family 2018 Washington State Energy Code-R BD Giddings Engineering, PLLC 10826 NE 108111 Street Kirkland, WA 98033 Phone: 425-218-3471 E-Mail: bdgiddina,S@gtnail,com PERMIT#BLD2022-00951 �S D GId NEW SINGLE FAMILY RESIDENCE WAs �,c df� � 620 SE SNIDER RD, SHELTON, WA , ENERGY CODE COMPLIANCE 4` To: Mason County Karl Adams EIS658 From: Beni G amin Giddings, PE GIs Date: July 17, 2023 7/17/23 The fuel normalization credit and energy credits shown on revised plan Sheet G2.00 meet the requirements of Section R406 of the 2018 Washington State Energy Code (WSEC) for a Medium Dwelling Unit. The WSEC specifically allows for the selection of one item from Table R406.2 and one item from each subcategory of Table R406.3, unless noted otherwise. The attached plan is based on the following selections from Table R406.2 and R406.3 for a total of 6.0 credits: Table R406.2, Heating Option 2 1.0 credits Table R406.3, Energy Option 1.3 0.5 credits Table R406.3: Energy Option 3.4 1.5 credits Table R406.3: Energy Option 4.1 0.5 credits Table R406.3: Energy Option 5.3 1.0 credits Table R406.3: Energy Option 6.1 ! 1.5 credits The WSEC does,not prohibit the selection of Energy Credit 3.4 in combination with Energy Credit 4.1. Energy Credit 3.4 requires the applicant to install a ductless mini- split heat pump system with zonal controls in the largest zone of the housing unit. Energy Credit 4.1 requires that all supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation. There are no ducts associated with the ductless mini-split heat pump system; however, there is an exhaust fan make-up air supply duct that, per Energy Credit 4.1, must be deeply buried in ceiling insulation. The make-up air supply duct is required under section M1503.6 of the Residential Building Code and is shown on Sheet A2.40 - and 53.20 of the Plan Set. While Energy Credit 4.1 can be used in combination with Energy Credit 3.4, Energy Credit 4.2 cannot. Energy Credit 4.2 specifically,states that "ductless heat pumps are not permitted under this option". This exclusionary statement is not part of Energy Credit 4.1 and,�as such, the combination of Energy Credit 4.1 with Energy Credit 3.4 is allowed under the WSEC. 4- SITE O O COPY 14 MASON COUNTY LIFE SAFETY REQUIREMENTS COMMUN1 SERVICES e w..rr:+se,..:.wa rxrs MC NM08w WING ETM _ GLamrG VFGUIREo%mxornvs ThaiaglTaLLorrNEr%zoxixczoxwrlaa:wxp ntF Boimxmc[a,mrxaX se• MarryulnmenbaOpNta a001C°WNNgrype;Mu6ngdenNeeaM-andtwWa hewenzngs andrMdDle i%fLeo;avPT.Erev FpeEoveuz%GaMPt TUX Y•aeN2Tl[IznDP,aNO'flAXFneRv celxEwvmewLWlFa eAFRp W s pw nw s4 singlNamwawerm:m0 _. .._yaemiendryWewmx 41a�IDGsapL[ENroµo0.R seJFtt�4tA1eW PEaNem gmupOwJMTpM ia•pe ERx[asD[CFTxEn000.axOCNaru11165 ttur,moETaEK Q�' Xadfi pamMlManw ¢p Sf SnNerPma ° I hra Xwmaea DaWW. A D%1`r` I�iawOmG talrNswMLi°rvlaX MG gCQn®%mnCOw3MRnH60•(MEWAFONWVLVRYEYavFarlGVYl Orw¢rttmRSWac6 aauyaaeme R.e( v/A90581 _ —. rues,SraL vnovixvs.5mwr:evmt581u.zn.5wws.m3lUraRemu. riOE PmddTralee 'm to Mml mwmmn JJmSs00m0e am—aigsN knabrarcaMeenan3 o 1_❑❑❑—. � U``�mfi YF¢Ta4IDIG REW RW%WUWWSYmM%N•(vIFa5YM1F0 NOwiQarNIYJPpIwLLmaYJWKCI Of Q bWWsW� R Mmesee aW V 0 4vaParleat ems -_ raTimwh °nirj° M.r¢umtomJmrrga�iNrom I�,mF°I IRC R310:EMERGENCY ESCAPE@0.ESCUE OPENINGS O l,,A-SF d(craiebnM Wing Sry¢ iDvamU ! Wnaow%F]zX eEORmuaVD BaspExievaTvxpTpfas.TSFmMWW xzrttFa0.GppaAF.aaxaten rEEOLLOmxe0.fgualatiris:tat .n.....rm,�unX.: t —rnukavaNaas D.eroR 1'os'!�7 � mrlarmawr ac Rmuem,NtQfo iouv"'xw,unargpvplxe rmexe:wv«•wmgwsaLJmexr.rx<X¢aE.Rovpaxuroewvfrmoa aw d«mn Y a ry m o w d Xm m mN a J. ---- '....._❑...... ----- ..-._.... }N :wmu:.—awwm.a..r rare%awwm,.wmawr w.0 - u Mmagwm.(M1smv1 saarma0aasmssl g' 7 yr'r:p E,na yo ❑ PER CONVERSATION'MTH IRC R311:MFANS OF EGPE55 W W raow:wxe unRsx,uwmrac.xmwlwaeaxE¢usspmcum,vEErTxermeso:erG amna<,.,.ErT}¢•wwwavuranwmTx rmpmp u. ( ❑ ..... ENERGY CREW IT CHANGE rm psra.ealwPTs meowuaxOClffwaswrn svnu TOvcrixvtsxgnmmnogafmv. ]—,.resaavm wlemEmrrzmvewma. s 1 :r enswwom:mowrcletamWpmiea.nnb,e,ner.ewnmawad.wesceDtis PamMlwa.a n d1 irX9,rppramdw mwmamvaa.sr a.eauatndrcshe peen mv%vn,nce aoPmMse nvmxrd Lg IwM.ravwmra,mErv.gmvmmmm 1s x¢TauwxsxaueE mnum evaeeomarr¢wmmTlawxun�erumsleniusTmeaawvuu afewamweeM.rcmeasauwzee bYtM permrceppGranL __-.._..--______— _o—._. __..-...._.___ is srTaauep,eusTceneiar.ano Prwle°.ntdnnaLLvleantlnfebr°gubhsav Woe'agpa:N,MNrgcnGeRmiJ-uwJ+tion and a_I—❑I___._...__.__. IRC RgCxrev�maW CampaMnLTa5k Rz0a]-fuNNamWWllmfaeCMaMd0a.3-FrregyONM. °'1• 'x _ ,ad faneadm -'j 3 1 FJPdmwM'aC Le d.--._._.__- em4TGN:vST[CN0.Sa12 vlWVF➢p¢LNIl¢M'GRGIw.WK10Eiafx YRPWGaW.;MOwfKNa0N11W,Kvl00RpvTXEINrtLLMG UNR ..,ummarasm.sR•geeam.;z � _ pNCT��n45EMrrrs�OxaeG�QU&°PTTtsalmxprnXulmxc<wnsvKpl.p'iW CanrwsCMv;MNOflFCiCRgIS.vuarw sw.LLm i mqA pbanryxvaC gd aNa te 15 IMpn Emma. _ t"o _ �rE ri Trio-:xo Xixouuo�wEoi, °%G.uroswu ne� e3%s themcrm lxsucxaw.rmeerrwixcaerwrrorr i �f` •='�itla•'�"e n — = e-- e'er wlmmrxvxru,w.NMeeemn •❑ i evmrrea<° '"wv.!vEp `se Tweuvn«rs"rrirEDr.°v'"Eonuwv'",m`mmEu`earParDvw°auim'""�`uuea "3i"`"rwur:Ep:J °•xaE W I w�n.meww» nun --_-- �'; IE%dww,krn.ar ❑ —_.. caXamalw srm¢.wv.,°wXorw�Eal.mufx¢uaT.uEolxsiuoofJmual.Rw. ¢E I �MIa.Gx.wm� wasygs le- 4"w sis Eglem,wa¢rxaanr. ..' a uMaeazynssgsamrdmelmd>um asr.aavXaedanpaukamtmmMpe^as w¢aurIRC R315:CARBON MONOstunm al m �� .; r asmanmNanuslw waerrlemh � raRmxxou�cuarxs vuueaenimps¢�¢11>�ar�ui,1. larEo%auww¢xirx lanu mXmXarmnReox g I i ! anaeonM WwwMe` Tewte[mrgrUnrerzmnJ za ❑ ". ) �'pnsnJ'.sre• anm�m�—mrmaaexerm v,araJ nmmnenur— � awHs.PeuQUlxEoalnroEr.ExsEuw.i°aEenxaw�waemoxfaw noagoeTle owax.muxR%accomueEmmraerlu � I j amm�] •Jo/vsnv�oM ensn.i..en` Rwm.larvnx.uw,ea rvu4e3mwfxomwa..aru¢wwrunarvuwanEourmmrxu•olnmrwoarrsmraraEo mremou.rrrcrawm+wx W - i ragnREo wvnnq smxoox. �w Me`mnmedtwdsemn:enwpnxcsmnranmwddaa w mmenndva..a•sm taefxaArgspmm d r(w NI e<asmnewwawsmw �na°hvowERmerxrLvcowwneosl—once,umvluE&wrv.[rncvarm%sLe'x•xwMil—lraaeruarwxa mwseMmwo-eahn..earm�ae.m nn Mn wuar•mel:mr,'�wMx:s�lkemeeare% min. .uw.¢ama worvmuaLmrcuJ•mwvr. ja w �rlmkaw�mws.u»ea,lmm au.nsww �3xln..aa}szls �T,Rw¢ auRwswrsruearEmR.T nwuTww¢rvneTxaslnunsmune.wo.wxruvawmvmursmmmPRn.rw•E � I 1 ' °tamgsda:.�e�e°"`tlm•.sM�x°artn naws.s:mraewr i��miwaas:.an�uose:la I merlin an WrWilW Vtlsmr]mvN.Mevube4�mmPerrn:.rN Paaaeter wtN��Wauzgsasx Tatleaeu.amr+he'Ipartinrnewn}OpUm}lmrvMmebMe [XW.masmCx:fW 3Wlprrra wmtlui<mvuk➢YPPnpsol➢YemEwmsfnimau;vs SNute;vEawTRt.) I f�RwT�v .AaPwnemm�iw�mx�yrw.eA smTm: as.r .vmeannaagaMv � vmnvndaamwl3a:A,am�wwem a,.e,awwm3e.aa:na. mwwain.srauuvwmXxwrouvEaw.sewulrsnumlru,FaoorvmauaR.a C � � � I a seva n,.M.m.abrer,,.alMrm,a «.mdaaam. wmawar.nnl.Ram]Im.u�nMmeMa.Namm�amaiwva. � ms.xmwa a n�ng+M W sme.rae oo e ro aumnua "�mnm 1.3 �lalmmmm�ansladu atm,unglanw.ahamegareuwaew nessvlbealnMnmaimlzlrcr,em smrezN foAoxri_ng Wife_alb n°ia—CnsedmTab!e R21.iwith Me N h o Vertlml fenestial U=0.28,Fbor RaB.Slab on grade R-10 j 1 perm Ad tl, aMeanarnMaxlNhrPZmnpsneOmmyYwfwmlfWeru oe,iem ham TaEk lraW]RrM anC Mat ephm sJearb e OnZltCao�WgOS aCav!p by scda sn S etan RRead0m2.e1l Aer: In rWsa�j g I j ' ' Te tlaim Weveei4 Pe htlHagpemntanwin®zlullmetlNitnoptknaekzmdandsAe Reduce the Tmal mMuctiva UA by G% N � umtaYed dAWinga'v lnka9eaM vhbweM olio%lirgvmtUa[bn sV%emaM in CpnMl xauenze opennan. 2.1 Compile.based an pal1,a,1,2:Reduce eM IesteC air mW WCIpry VNe3o-eeM Iwd wanins Nan 19G0tl—Feateletan-d Wnlea Wn3mdNtmerva n ImaWisgmemDa3.0 air Charges Derma L Aeditlam roagtln6 gCAlry Patna greattrPan500ddheandaoerartafM iess Nan 35m G. i50 Pasmk or For R-20CcuPar Jes.oD"�mal L Mwam pweuwuaasueeM MEDIUM DWELLING UNIT,6 CREDITS REQUIRED �Wa'm lm3ea Dn senwn aaoz.a.l2:Rmtm me t�lea na W Menelruq WtaM rw[Intluaedro ei we3 leakage lP 0.3 nfMsi maNrmJm el50 Paxals andMwirole fl g 3.Dw`�e IOwIMe VNt><reaM uyanMemMirys.appsldmw'rtroaeafroma:.a house vent0alion regWrements esdetemlined Ir/Section ur a atlaldemleuwnsmaouan fem i.s areaFs �' M150term"Ihel Madhallal Cedesn�Cadet Sea hm;h Au mneraeammnebad m«z ld above the Inlama0onal Machoniwl Cede shall be met wiN a hgh efficanq fans)(maximum 025watra(cim),nm interlocked wxN 9 Ine fumam tan(if presenth woilat!en systems using a fernam Old.ng an ECM motor ere all-sefflheyareeommileete m G operate at low speed in ve,lWatmn only mode. HVAC SYSTEM EQUIPMENT SPECIFICATIONS INSULATION Ft FENESTRATION REQUIREMENTS ti heating in We p heal p rdmxGrcOou aselm✓.v:ourmmuXirs:Nadzacaxawr SRu-s}Tarapt-,a.m 0.5Ductless splesystem Matpumas lrro electric p resistance rimary living area}A ductless hem system _ TABLERIO].i./ vdLh a rNrdmum HSPF e110 sM0 M sized arM installed to provide DUCTEJ3�nWO0.wNLWWnmunirasa'jlRz��swvepl�/6zLmpKaNOJJDe-e Dan iNeULATION ANO FEq�TAATbN R£UUIREMtMBRY CA4PpNENi• WRIT5¢n01L aLLYz%caMebC6rrIWBEvSmeEVTuiGp 9YMnt mlrmKJdlPR10] —tee'..NaWgEa heatto entire dwelErg Wit elihe tlesign aulAcor a'v IGmpe!ntln'e. yy m pmuziwaxpamuzrtwN. �pExasn—liuF la, waERxVOEa:XCPRI¢nf UFe;O.n 16nyLmhi°ViACIOR OSO : P°Rpmcovrwx J.l rgsysems 9:S.SWcbeet pump t haermetig the amli,rdwin 3 el l NEE Mat pump water heater meeting No le,I F1s ire Tler III WNEEA's advanced water Mating specification m For R-2 �5 21 in 1 Occupanq,el e,IIIhealEEK,water heal a a—ding.tl:e WINDOW SPECIFICATIONS �!FLooaJE-vnwe��ay�8 _ standoMsfor Tior 111 of NEEA'saMant•Jd water heafmg r-t. naLmRdvaO£e•WM1PovaUJ[ IUHSR1iN+sTR 10,2 3Pa �ien,aMll sUDPb tlome3liC MLweter to ell uNLs.liwe _ 'o ¢sxzXrvxoma:a%oERsmr,mstxes,zowErnnJttewn ;gspga•µygsyEa PEPTH fl water Meter is serving mwa[han one dwa0irg unit,a0 not water 5 CwgEmeaTraET.wooer}aecunarlmy"up. Numus'0.U-o.Ea pipe :nlmum�.I, ecircWalion DiO SsMAbc insulalM win R� V ' .arlaar+amr+f aalrm.� certaumf mnueve ran Pndukn ppe insulation. � rcxowRToe[raae CEervrto e.reap-J�r ees aom uncap vUndure eam reu. WHOLE HOUSE VENTILATION SYSTEM wxmg rauu wTa,ndx srsrLv,wr mmMr Rm a lmxmw sons.s¢sJXEre.,.JO a.Lm. AIR LEAKAGE TESTING wsmEE xmse.%¢aafa,Im ro px¢n LDaw waea Pp timR ar m PnY.LL ® NimleN-1a Changes Reviewed for Code Compliance —`-"Approved for Issuance Submit changes for approval Mason County Building prior to performing work Department r RE-- RESULTS Caution: Photovoltaic system performance 1,913 M/Year-, calcu a6O predictions Inherent by PvwtIons Include System output may range from 1,838 to 2,002 kWh per year near this location. many Inherent assumptions and Y P Y 9 P Y uncertaintles and do not reflect variations between PV technologies nor site-specific characteristics except as represented by Month Solar Radiation AC Energy PVWatts®Inputs.For example,PV modules with better performance 'are not (kWh/m2/day) (kWh) differentiated within PVWar.@ from lesser performing modules.Both NREL.and private companies provide more sophisticated PV January 1.36 61 modeling tools(such as the System Advisor Model at//sam.mel.gov)that allow for more February 2.5] 105 precise and complex modeling of PTV systems. The expected range Is based on 30 years o1 March 3.37 147 actual weather data at the given location and is Intended to provide an Indication of April 5.03 209 the variation you might see. For more Information, ErrooRew ra refer to this NREL report: May 5.52 230 - - — - —- June 5.70 227 Disclaimer:The PVWatts@ Model("Model") July 6.14 249 Is provided by the National Renewable Energy Laboratory ("NREL"), which is operated by the Alliance for Sustainable August 5.86 240 Energy, LLC ("Alliance") for the U.S. Department Of Energy("DOE")and may be September 4.73 190 used for any purpose whatsoever. p The names DOE/NRELIALLUINCE shall not October 2.77 120 be used in any representation,advertising, publicity ar other manner whatsoever to endorse or promote any entity that adopts or November 1.54 67 uses the Model.DOE(NREL/ALUANCE shall not provide any support,consulting,training or assistance of any kind with regard to the December 1.50 68 use of the Model or any updates,revisions or new versions of the Model.YOU AGREE TO INDEMNIFY Annual 3.84 1,913 DOE/NRELIALLIANCE,AND ITS AFFILIATES, - OFFICERS, AGENTS, AND EMPLOYEES AGAINST ANY CLAIM OR DEMAND, INCLUDING REASONABLE ATTORNEYS' Location and Station Identification FEES,RELATED TO YOUR USE,RELIANCE, OR ADOPTION OF THE MODEL FOR ANY PURPOSE WHATSOEVER. THE MODEL I PROVIDED BY DOE/NREL/ALLUWCE'AS IS' Requested Location 620 se snider rd shelton,wa AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT Weather Data Source Lat,Lng:47.17,-123.02 1.6 mi LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY Latitude 47.17°N DISCLAIMED. IN NO EVENT SHALL DOE/NRELIALLIANCE BE LIABLE FOR ANY Longitude 123.02°W SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO CLAIMS PV$ stem Specifications ASSOCIATED WIIH THE LOSS OF DATA OR y p PROFITS,WHICH MAY RESULT FROM ANY ACTION 1N CONTRACr, NEGLIGENCE OR DC System Size 1.8 kW OTHER TORTIOUS CLAIM THAT ARISES OUT Y ¢ OF OR IN CONNECTION WITH THE USE OR d{ PERFORMANCE OF THE MODEL Module Type Standard The energy output range Is based on analysis of 30 years of historical weather Array Type Fixed(open rack) data, and Is Intended to provide an indication of the possible Interannual variability in generation for a Fixed(open System Losses 14.08% rack)PV system at this location. Array Tilt 20° Array Azimuth 180° DC to AC Size Ratio 1.2 Inverter Efficiency 96% Ground Coverage Ratio 0.4 Albedo From weather file Bifacial No(0) Jan Feb Mar Apr May June 0% 0% 0% 0% 0% 0% Monthly Irradiance Loss July Aug Sept Oct Nov Dec 0% 0% 0% 0% 0% 0% 1 1 Performance Metrics DC Capacity Factor 12.1% BD Giddings Engineering, PLLC 10826 NE 108th Street Kirkland, WA 98033 Phone: 425-218-3471 E-Mail: bdgiddings@pmail.com PERMIT #BLD2022-00951 NEW SINGLE FAMILY RESIDENCE 620 SE SNIDER RD, SHELTON, WA DESIGN CLARIFICATION: 2'x7' Footing Pad Et 6" Steel Post jN WA GId pF SFijj�, d To: Mason County Karl Adams From: Benjamin Giddings, PE Structural Engineer of Record 29658 w� �`ssIG� Date: May 24, 2023 ONAL 5/24/23 The 2'x7'x8" footing pad and associated 6" diameter steel post shown on Sheets S1.10 and S1.20 are no longer required and do not need to be installed. � I BD Giddings Engineering, PLLC 10826 NE 1080 Street Kirkland, WA 98033 Phone: 425-218-3471 E-Mail: bdQiddines@gmail.com PERMIT #BLD2022-00951 NEW SINGLE FAMILY RESIDENCE 620 SE SNIDER RD, SHELTON, WA OI wD Idd FOOTING BEARING CAPACITY INSPECTION °� NGT t� To: Mason County Karl Adams From: Benjamin Giddings, PE o s FC29658 Geotechnical Engineer of Record . sjoNaLEr� Date: April 26, 2023 4/26/23 Footing soil bearing conditions were inspected on April 26, 2023, to verify . conformance with the approved construction plans (the "Plans"). Foundation footings have been formed and are ready for concrete placement. Underlying soils are solid and un-yielding and will provide the 2,500-pounds-per-square- foot bearing capacity as specified on the Plans. The owner understands that compacted fill will be required around the foundation perimeter to provide a'minimum of 12-inches of cover from finished grade to the bottom of the footing.