Loading...
HomeMy WebLinkAboutBLD2002-00597 Cancelled Carport - BLD Permit / Conditions - 8/11/2004 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 1� RESIDENTIAL BUILDING PERMIT BLD2002-00597 OWNER: LEON BORST CONTRACTOR: LICENSE: EXP: RECEIVED: 5/17/2002 SITE ADDRESS: 121 NE SANTA MARIA LN BELFAIR ISSUED: 5/12/2003 PARCEL NUMBER: 123305300028 PERMIT EXPIRES: 11/12/2003 LEGAL DESCRIPTION: BEARDS COVE DIV 6 LOT: 28 121 NE SANTA MARIA LN BELFAIR NULL & VOID 9Y EXPIRATION PROJECT DESCRIPTION: DIRECTIONS TO SITE: ATE 4, Ilt I04 BY CARPORT NORTH SHORE RD TO SAND HILL TO LARSON BLVD TO LARSON RD TO LARSON RD TO SANTA MARIA LN General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: V-N Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Carport-Detached 276 Valuation: Building Height: 18 Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 25.0 Ft. Shoreline: Ft. Water Body: SEPA?: No Rear: IN78.0 Ft. Slope: Ft. i Model: Width: Ft. Side 1: W 12.0 Ft. Shoreline Des g.: Not Applicable Year: Serial No.: Side 2: E 72.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt EH Plan Review CEW 5/21/2002 $35.00 S12003 Building State Fee RLS 6/6/2002 $4.50 S12003 Building Permit Fee RLS 6/6/2002 $97.25 S12003 Violation Investigation Fee RLS 6/7/2002 $52.30 59307 Plan Check Fee KS 12/27/200 $63.21 59307 Violation Fee KS 12/27/200 $97.25 S12003 Shoreline Pre-Inspection Fee KS 12/27/200 $20.00 61575 Shoreline Pre-Inspection Fee KS 12/27/200 $50.00 S12003 Total $419.51 BLD2002-00597 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2002-00597 CONDITIONS FOR BLD2002-00597 1) This application.is subject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at X 800-64,7-_09982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 3) The use, handling and storage of hazar Qus materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your roject. ().�X 5) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X n 6) All construction and demolition debris must be removed from the beach after project completion. Prop rposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degredation of State waters. X �� 7) Approved per dimensions and setbacks on submitted site plan. X �� 8) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Xepatme�nntt prior to any further inspections being performed or approvals granted. BLD2002-00597 Please refer to the following pages for conditions of this permit. 2 of 4 9) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or X contractor ail to post the address on site prior to requesting inspections. 10) The plan review check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plan on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 11) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit shall be applied for, reviewed and approved prior to the change. X r 12) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 13) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Xuilding_Department prior to any further inspections being performed or approvals granted. 14) This structure is limited to U-1 use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the Uniform Building Code and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. X 15) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in p rMit revocation. X .Fr.�__> 16) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance or regul tion, must be reviewed and approved by Mason County prior to construction. X - ` I:? 17) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect9f shall be made prior to requesting additional inspections. X � 18) All property lines shall be clearly identified at the time of foundation inspection. X —� BLD2002-00597 Please referto the following pages for conditions of this permit. 3 of 4 19) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Masora County ordinances and building regulations. X —� 20) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder ave prevented action from being taken. No more than one extension may be granted. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of ntinuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. OWNER OR AGENT: z _ �'�� DATE: z z� _ BLD2002-00597 Please refer to the following pages for conditions of this permit. 4 of 4 W 0 o CONCRETE MECHANICAL MANUFACTURED HOME . 0 ^� Footings /Setbacks Date B y Ribbons 0 C) Date By Gas Piping Date By m Foundation Walls Date B y Set-up Date By INSULATION Date By B G / Slab Insulation Floors Final Date By Date By Date By FRAMING Walls FIRE DEPT Date By Date By Date By PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING D.W.V. Date By Date By FINAL INSPECTION Water Line Date By Date By a x• �_ . ' �. �` Date By 0 m 0 0 cn w cn 0 8 to 0 .. m Q �1 o y N r o � «� O 0 PERMIT NO.: BLD MASON COUNTY �II� BUILDING PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275A467 Elma 360 482-5269 Seattle 206 464-6968 APPLICZNT INFORMATION CONTRACTOR INFORMATION Owner Eo N( jp1ZS Contractor Name Mailinq Address I'Xt +JE itr T'1A NA-#0Zi h LF Mailing Address City 6E4.F 4i R StatelN.t Zip Code 91B 3-$ City State Zip Code Phone( v ) 77$-53,Y9t Other Ph.(36p.; ) -39.1 o Ph.( ) Other Lien/Title Holder Bc F-i i4i F +� gontrtor Reg. # Address t3.. trr �.��rir0.� VJ�%• acExpiration SEPTIC/WATER SYSTEM INFORMATION-Connect to Ne* Sep tic Existin , ic, Connect S ewe System Name of Sewer System Well ater System - ; tme ��� Water System \v PARCEL INFORMP� N-12 digit Tax Parcel No. U / / GAGZ Fire District Legal Description ,"if , V" . r u Z Site Address(Pleas include street name, street number and city) 1�l i�E ' 4 ,(T-* I�IrlZ�A� 3cZrY(J A Directions to siteot"4 SNozc "fz5 't-0 'iAOt> 1ttt_c- -rn (49titS01`4 C.V 2 T1) GAa50,o ib Will timber be cut and sold in parcel preparation? (Yes/No) 1- O Is your property within 200' of the following: Body of Water (Name) Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs PERMANENT RESIDENCE 0 SEASONAL RESIDENCE❑ TYPE OF JOB New �Add Alt Repair Other Use of Building Describe Work �, No. of Bedrooms No. of Bathrooms SQUARE FOOTAGE=1st Floor 2nd Floor 3rd Floor Loft Basement Deck Other sq. ft.� o Garage Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. X Date X Date FOR OFFICIAL USE BEYOND THIS POINT , Accepted by t '. Datqol kLzsubmittal Amount Due ;/ Receipt No..:) �1 DEPARTMENTAL REVIEW APPROVED DENIED CONDITION CODES - Building Department Occ Group 1114- Type Constr. v%`+ iOW Planning Department Environmental Health Department Public Works Department I Fire Marshal Valuation $ FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing&Base Fee Planning Review Fee Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal ( ) TOTAL FEES �1 C" =6 4/S,.o s I T D' , 4 1SC7 /2X �'►iFa7�0�-c.��0 427-9670 MASON COUNTY BUILDING DEPARTMENT ALL PERSONS ARE HEREBY ORDERED TO AT ONCE TOP WORK On these Premises at This order is issued because A.M. Posted P.M. 19 By VARN 1 NG The failure to stop work, the resuming of work without permission from the Building Official,or the removal, mutilation,destruction or concealment of this Nqticq is ishable by fine ano imprisonment. Mason County Dept. of Community Development Mason County Bldg. 3 426 W.Cedar P.O. Box 186 (360)427-9670 Local (360)482-5269 Elma Shelton,WA 98584 (360)275-4467 Belfair (206)464-6968 Seattt Notification of Permit Cancellation December 19, 2002 LEON BORST 121 NE SANTA MARIA LN BELFAIR WA 98528 Case No.: BLD2002-00597 Parcel No.: 123305300028 Project Description: CARPORT Dear Applicant: Upon review of our records, the Mason County Permit Assistance Center has identified that your building permit application has been approved and ready to issue since 06/07/2002. Once approved, permits are valid for 6 months. If you intend to obtain this permit, you must make arrangements to do so within ten (10)working days from the date of this letter. If we do not hear from you within the that time, your permit will be cancelled and a building inspector will make a site visit. In the event that your project has been completed and a permit was never issued, you will be assessed penalties as allowed under Mason County Ordinance 37-96. If your project has been cancelled or if you wish to withdraw the permit, please notify i me as soon as possible at(360) 427-9670, ext. 354. If you feel that you have recieved this notice in error please contact me. Thank you for your cooperation. Sincerely, ��-� Kathleen Soine rwl- December 19, 2002 BLD2002-00597 i ) EX15T.510IN6 EXIST.WALL SHTG NOTE, EXIST.2x STUD 0 24'MAX. RAFTER BEAM,COLUMN 5IZE AND THEIR5 CONNECTION ARE BASED ON THE FOLLOWING A5`S(WTION. METAL FLASHING VERTICAL LOAD: ROOF 5HT6 TO LEDGER NAILING SGHDL ROOF OL=10 P5F(NO TILE ROOF) U2'O58 ROOF SHTG A 8d DC-B 8604 OC SNOW =25 P5F AT ALL SUPPORTED PANEL EDGES AND 8d■10'OG INFIELD MIN.RF SLOPE PER UBG 1991 WIND:EXPOSURE G,80 MPH,IN=I. OR LOCAL JJRI5DIGTION ROOFING MATERIAL MIN.LEDGER SIZE SEISMIC:ZONE 3,SOIL TYPE=3,1-1 /'\ 2X8 MIN. (O-10'DI5T TO BLD6) 8D ob'OG 2XIO MIN.OR 2XI29(10-I6'015T TO BLD6) 2XI2 MIN.OR 2XI4=(16-20'D15T To BLD6) RAFTER 51ZE5 (DF#2) FULL BLOCKING \ =MATCH WITH RAFTER 51ZE BIRD MOUTH AT BEARING LEDGER TO EACH WALL STUD NAILING SGHDL DISTANCE TO BUILDING / (STUD SPACING SHALL BE 24'OC MAX) 0'-10' IO'-Ib' I6'-20' (3)-16d 5TA66ER(0-10'D15T TO BLD6) `2 12'OC 2 X 6 2 X 8 2 X 10 GUTTER(TYP) _ (4)-Ibd STAGGER(10-Ib'DIST TO BLD6) Y Ib'OG 2 X 6 2 X 10 2 X 12 RAFTER DF$2-SEE RAFTER SCHDL (5)-16d STAGGER(16-20'D15T TO BLD6) 9s 24'OG 2 X 8 2 X 12 2 X 14 METAL HANGER 5IMF`IRR5�H1 OR ETA END of s" ON Lsu26 (2xb 'E� BEAM SIZES (DF#2) 5IW50N L55Qb(2X8 RAFTER) 51MP50N L55U210(2XIO/UP RAFTER)OR DISTANCE TO BUILDINb 2MAX BEAM DFN2 SEE BEAM 5CHDL EGU� METAL P05T CAP 5' 4 X 4 4 X 6 4 X 6 SIMP50N AC4(4X4 COLUMN) 6' 4 X 6 4 X 6 4 X 8 51MP50N AC&(4Xb C40U W OR 95 T' 4 X b 4 X b 4 X b EQUAL 8' 4X6 4Xb 4X10 1 L 4X8 4XI0 4XI0 COLUMN HFMI PRESSURE TREATED 10, 4 X 8 4 X 10 4 X 12 10'MAX 04(0-IO'DIST TO 506) 4X6(10-Ib'DIST TO BLD6) X7 4X6(I6-20'DI5T TO BLDG) W BEAM --++-- BEAM 2' F SPAN AN MAX I NQT AGGEPTAPLE METAL P05T BASE(6AVANIZED) L T — — 514P504 L0844(4X4 CO" DISTANCE 51HP50N LCB46(4Xb GOLUMN)OR � TO BLDG. FOOTIN6 4 BEAM(TYP) EQUAL W I COLUMN(TYP) 1 2'GLR �� 6'MIN (1YP) BUILDING �— � L � SLOPE FINISH GRa AWAY PROM BLO6 CONGRETE FOOTING I'-b'MIN 24•X24'X24•THICK W AccEPrAeLE STANDARD DETAIL FOR ATTACHED 3-GLR Vc=2500 P51 W/ ■ ) 2-*4 EA WAY TOPiBOT LAYER w=a1sTANCE To BLDG. RE5IDENTIAL CARPORT 2'5Q FT6 3'GLR I.C.B.O.OLYMPIC PENINSULA CHAPTER (�) 5ECTION PLAN N.T5 KT5 SCALE DATE DR BY J08 NO Dwb NO NONE 3/3/w98 -1 I F► i , i y � i � 1: L i V i AN Ne/ 01 ! i I i`- i I I I _._ TOPOGRAPHY PROFILE: Direction: Scale: Approval: for office use Building Permit number: Building: Owner/Applicant: Date of Planning: application: Env. Health: Parcel Number: r /w G 1r�r J boo/ Q �! �S6 +p� w o� ZCYPI ' 9 a J i Q i � Vi i�7v