Loading...
HomeMy WebLinkAboutBLD2000-01141 Cancelled MFG Home - BLD Permit / Conditions - 10/25/2004 Inspection Line 360) 27262 -- MASON COUNTY PERMIT ASSISTANCE CENTER Phone: (360)427(96704ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 i RESIDENTIAL BUILDING PERMIT BLD2000-01141 OWNER: KELLY ROHR 360-509-1658 CONTRACTOR: -(��EIVED: 09/06/2000 SITE ADDRESS: 220 NE SCHOONER LP BELFAIR e EXP%VkA ISSUED: 10/30/2000 PARCEL NUMBER: 123305200028 VO, EXPIRES: 04/30/2001 LEGAL DESCRIPTION: BEARDS COVE DIV 5 BLK: w LOT: 28 )b�2 �� PROJECT DESCRIPTION: DIRECTIONS Td' MANUFACTURED HOME FROM SHELTON GO OUT HWY 3 TO BELFAIR TURN L ON NORTH SHORE RD TURN R ON SANDHILL L ON LARSON R ON SCHOONER LP RD PROPERTY ON RIGHT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr : Type of Use: MH Insp. Area: No. of Bathrooms: 2 Occ. Group: Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Valuation: $5,000 Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline & Planning Information Make LIBERTY Length: 44 Ft. Front: S 60.0 Ft. Shoreline: Ft. Water Body: Rear: N 17.0 Ft. Slope: Ft. SEPA?: Model:LIBERTY Width: 24 Ft. Shoreline Desig.: Side 1: E 23.0 Ft. Year:1984 Serial No.: 09L2027 Side 2: W 31.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Mobile Home Submittal KLW 09/06/200 $175.00 1989 B3 Nding State Fee TLG 09/08/200 $4.50 54962 Mobile Home Issuance TLG 09/08/200 $175.00 54962 Pftning Review Fee AHB 09/18/200 $38.00 54962 EH Plan Review CEW 10/25/200 $50.00 54962 Total $442.50 BLD2000-01141 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2000-01141 CONDITIONS FOR BLD2000-01 1 41 1) Prior to occupancy approval being granted for the unit authorized under this permit, the existing unit which is being replaced on site, MUST be removed from the pa X rc el. 2) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO P ST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X 3) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 4) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan is not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(mini 1 hour)will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X 5) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the 1997 UBC, and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this inv ,will be scheduled as time allows. Until resolution of any/ I problems no occupancy (Final Inspection) will be granted for the residence. e NER/CONTRACTOR(indicate which) Signature X 6) All mobile/manufactured home landings or decks must be freestanding (self supporting). The largest landing or deck allowed without drawings or a building permit MUST be under 30" in height from surrounding grade. NO second story decks, or decks above 30" can be built without a permit. Any landing or deck that is 30'Z' r or�eight from walking surface to finish grade requires a Permit. Any landing or deck that has 4 or more risers requires a handrail. X 7) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. BLD2000-01141 Please refer to the following pages for conditions of this permit. 2 of 3 8) All property lines shall be clearly identified at the time of foundation inspection. X 9) This application is subject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X Wf 10) The use, handling and storage of hazardous mat M-0'r f r�imable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X Ir 11) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may aff t our roject. X 12) Approved per dimensions and setbacks on submitted site plan. X LX 13) Proposed structure or any portion thereof greater than 30" in height from grade li must maintain a minimum of 5'setback from all property lines, easements and 10'from all County and State Road right of ways. X 14) Any portion of any structure over 30" in height from surrounding adjacent grade must be setback fro II utility and drainage easements, a total of 10' from each property line, or a variance must be obtained from the Building Department. X 15) All upland areas disturbed or newly cr ed b construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 16) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenc . Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building ct;E cV�:— OWNER OR ENT: ll ATE: I �� BLD2000-01141 Please refer to the following pages for conditions of this permit. 3 of 3 CONCRETE MECHANICAL MOBILE HOME Fo-tings-Setback date by Ribbons data _ by Gas Piping date / — d b F jur"viati Sri Walls date by Set Up date by INSULATION date by _ BG/SLAEt Insulation Final Floors date MIND by date by date by FFV4Walls FIRE DEPT. date by date by date by PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by zz— �. _p o— � . ,� FGs- �-o� -✓ -- !•� i/-�/ nod% -- I�i9-�✓ /��.�T d i .P/�y F i . /2 2) •1G��-�o/I T JDId�/ c� c �jini �, ar��ti, y�� ,0 � r ZiLkZoe�nd YID Ct�sr7'�c� C4Sfitis-er -21'U Qc�✓ist 7�L�a� /J�v�ri 1� ll� =�fS w6;?.3tr re,h�glc,F Ycr_e itlictis!rrr r►ulf.�> 3�so' .5-D9'/� �g MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (206) 427-9670 CORRECTION NOTICE Job Location ge:w l) Z z This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain code compliance 7/-Q Zce a You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK .Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to �% ryc�i �cc c Department 513� Date ` Inspectors/Z, ■ oo * NnT MnV THU T' Low, Building Permit # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location lYonI7 - y zZco This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance 7`hk/S r' TG /O f,moo G .✓ L �cTiC�,•� You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing I ❑ Make corrections, items will be checked on next inspection p OK to ❑ This is not a complete inspection Department .6L� Date Inspector ,T ■ �k AOT MOOV THU- TmL* qi Washington Home Center, Inc. Floor Plan Wynnewood 4663B,Revised 2000 Model-Randy And Deborah Ransom 4663E (2000) 3 Bed 2 Bath Approx 1804 Sq Ft 00 10 i Bed K Do L Dining Kitchen p OQ 0 { 19 D15 0 { 18 j '0 ,- r 1 Bed j2 ( 1 7 Den { 13 ii Living Room Maste(L� m 1 20 g 1-41 { 14 '1 1 { 12 8 {2 { 14 ,{ 21 � 5 1 {D21 1 Relocate Window 8 Phone Jack 15 Ceiling Fan-Wire&4-Speed Switch Only 2 White Hollowcore Wardrobe Doors: 48" 9 Dormer,24' 16 Brace Std Light For Future Customer Installed Ceiling 3 Shower,60"2 Seat Stall W/Enc,Master Bath Only(Wid 10 Sliding Glass Door W/Vertical Blinds Exch W/Windov 17 Omit Study/Study Wall,combine To Create Bed 4 Additional Window,30 x 40 Safety Obscure-Vertical S 11 Additional Interior Outlet 18 Add 3rd Full Bath With 48"Shower 5 Frostless Hose Bib 12 Additional 14 X 40 Bath Window-Vertical Slider 19 Modify Hall Per Print To Allow Alterations 6 Additional Exterior GFI Outlet 13 Vinyl In 3rd Bath To Be 69757 20 Additional Window,62"x53"-Horizontal Slider 7 Vitreous China Sink W/Popup&Overflow 14 Over Head Ceiling Light-Bedroom 21 TV Jack Specifications subject to change. (c)1996 sottSeu,Inc. Oct/11/2000 L-OT Xs D�J�S�otil S �6E.a�S LoJE. '�►C'� JV'�- y � 1 D C yob 7 ft a r h � l � 3 3s 1' I w Se- 14------------ SGAL-E I " = -2o `1 lk- v� , i �v q ,L iX �1 PERMIT NO.: BLD MASON COUNTY BUILDING PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 2754467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATION Owner KaA-L—Li To L&r Contractor Name 0L.JA-1 4Pe— Mailing Address o / / Mailing Address City e State Zip Code 2 City State Zip Code Phone(�p� - ther Ph.( Ph.( Other Ph.0 Lien/Title Holder 4-e f / L/eti i Contractor Reg. # Address Expiration SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic Connect to Sewer System Name*C*/ 5 Sew System Well Water System f0 Name of Water System e e,0 R PARCEL INFORMATION-li digit Tax Parcel No. / _/ O Fire District Legal Description rd S t.O % Site Address(Please include street name, street number and city) NoE. 94XO 3U�- Directions to site /� 6-0 T A4.0 .�✓ Will timber be cut and sold in parcel preparation? (Yes/No) pQoPt/ Gv✓�i fi I Is your property within 200' of the following: Body of Water(Name) Sa water Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs PERMANENT RESIDENCE SEASONAL RESIDENCE❑ TYPE OF JOB New Add Alt Repair Other Use of Building /✓i�✓ G.• Describe Work cMo✓ L`X� •1�.y /X0 "_ �•f L 1.��� No. of Bedrooms No. of Bathrooms SQUARE FOOTA E-1st Floor 2nd Floor 3rd Floor Loft Basement Deck Other sq. ft. GaraLe Attached Detached Carport Attached Detached MOBILE HO E INFORMAT ON-Make 1 16l Model Ib'f Model Year Length Width erial No. L ,2p 27 9VA4 No. o Bedrooms Z 4 - No. Bathrooms - Type of eat 2eit 46rchase Price $ Replacement Unit ? No) Installer Name nJ Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this ermit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance th r wi No hanges shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without ap first obtaining approval. X Date Z X Date FOR OFFICIAL USE BEYOND THIS POINT Accepted by / ( a Date Submittal Amount Due Receipt No. �?)9 DEPARTMENTAL;IREVIEW 4qRO DENIED ' CONDITIO.WCODE5 Building Department Occ Group Type Constr. Planning Department Environmental Health Department Public Works Department I Fire Marshal Valuation $ FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing&Base Fee Planning Review Fee Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee State Fee �_- Violation Fee Pre-Paid at Submittal ( ) TOTAL FEES i MASON COUNTY PROJECT SITE INFORMATION Case No. Name '' PARCEL NUMBER Date SHOW THE FOLLOWING ON SITE PLAN Show Direction by indicationg N, S, E, W in relation to the site plan f11 Lot Dimensions Fences Existing Structures Driveways Structure Setbacks Shorelines Water Lines Topography Well Location (including adjacent) -Drainage Plan Names of Streets Easements Names of Fronting Streets ,Septic System Ej DRAW SITE PLAN BELOW Include adjacent properties if on shoreline or within 100 feet of adjacent property line. adjacent property line- I I E-adjacent property line I 10-7 4 I 1 I � I I I ... ��. «. I � I I n I I }"` # I I ? I I I I I I I I adjacent property line-� <-adjacent property line SAMPLE SITE PLAN adja�nt property lined Fadjacent property line I p 30- F ;tome �r I SEAS w!AL I a CREEK � I 1� 1 HOM L� I G46.G�J I Hocu4 I j Pao Posen sap+.:C- �I L 1 I I VAGn,T I C ARAM I / I,•r� P0.nPmCD R A6RtLulTLL0.AL SO 1 I I , I I � I I /oo' I I I I I I � /DD. I 'Il adjacent property line- i a'. c ro e4 line TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. If possible include height and the degree of slopes. See sample topography profile.) SAMPLE TOPOGRAPHY PROFILE d1 s+ar.Gt to Sr+rtaGi-ta.YL d�at�.,cG to Slops -rag t ; Signature V I Date I �