Loading...
HomeMy WebLinkAboutBLD2006-01289 Final SFR with Garage - BLD Permit / Conditions - 7/3/2007 r MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)127-7262 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 1104 RESIDENTIAL BUILDING PERMIT OWNER: BILL & BARB BURGESS BLD2006-01289 CONTRACTOR: LICENSE: EXP: RECEIVED: 7/20/2006 � SITE ADDRESS: 40 NE SKIPPER CT BELFAIR -1 � PARCEL NUMBER: 123305100074 v Al� ISSUED: 9/25/2006 LEGAL DESCRIPTION: BEARDS COVE DIV 4 LOT: 74 EXPIRES: 3/25/2007 PROJECT DESCRIPTION: SFR W/GARAGE DIRECTIONS TO SITE: SR 3 TO NORTH SHORE RIGHT ON SAND HILL LEFT ON LARSEN LEFT ON SKIPPER COURT. General Information Construction &Occupancy Information No.of Bedrooms: 1 Type of Constr.. B- Square Footage Information Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3, U Lot Size: Type of Work: NEW Fire Dist.: 2 No.of Stories: 2 Occ. Load: Deck: 28 Valuation: BuildingHeight: Building:1,171 Garage-Attached 288 g Occ. Status: Prima Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: N 43.0 Ft. Shoreline: Ft. Water Body: Model: Width: Ft. Rear: Ft. Slope: Ft. SEPA?: No Year: Side 1: W 5.0 Ft. Shoreline Desig.: Not Applicable Serial No.: Side 2: Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty Type Dishwasher By Date Amount Receipt 1 Exhaust Hood 1 Plan Check Fee cMH 7/20/2006 $564.04 B12006000 Hosebibs 3 Furnace<100K Kitchen Sink 1 Planning Review Fee CMH 7/20/2006 $155.00 612006000 1 Gas Outlets 2 Address Fee GMM 7/24/2006 $140.00 S12006000 Lavatories 2 Propane Tank Building State Fee Showers 1 1 g JRN 8/7/2006 $4.50 S12006000 Ventilation Fan 3 Mechanical Base Fee JRN 8/7/2006 $23.50 S12006000 Water Closets (Toilets) 2 Dryer Vent 1 Plumbing Fee JRN 8/7/2006 $68.00 s bb-sboo Water Heaters 1 Plumbing Base Fee JRN 8/7/2006 $20.00 S1200600b Clothes Washer 1 Building Permit Fee JRN 8/11/2006 $888.75 S12006000 Mechanical Fee JRN 8/11/2006 $75.75 S12006000 ADJUST--Plan Check Fee JRN 8/11/2006 $13.65 S120o6000 Public Works Review JES 8/22/2006 $36.55 S12006000 Public Works Review JES 8/31/2006 $36.55 S12006000 EH Plan Review ADR 9/19/2006 $75.00 S12006000 Total $2,101.29 BLD2006-01289 Please referto the following pages for conditions of this permit. 1 of ,, r CASE NOTES FOR BLD2006-01289 CONDITIONS FOR BLD2006-01289 1) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depart ent prior to any further inspections being performed or approvals granted. X 2) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 4.$a 3) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of a�proved documents will result in failure of required building inspections. X_ 4) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X �j 5) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window(Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X. (j/1, 6) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X_ (S BLD2006-01289 Please referto the following pages for conditions of this permit. 2 of 5 7) Per 2003 IRC - SECTION 1609 -WIND LOADS- 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the 1 minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC W ND SPEED (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X 8) Per 2003 IRC -SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance wj h fhe applicable provisions of this section and the manufacturer's installation instructions. X__ 1���! 9) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X / 10) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged anA shall X be collected by the Building Department prior to any further inspections being performed or approvals granted. /mil. 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev a ,on. X �,� 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ) �n ,7 13) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinaM regulation, must be reviewed and approved by Mason County prior to construction. X 14) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X BLD2006-01289 Please refer to the following pages for conditions of this permit. 3 of 5 15) Aft propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10'from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5'from any building opening (foundation vents, windows, doors etc), property line or easement. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X (,6 16) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10'from any building, property line, public way, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. If a propane tank is exposed to prob le vehicular damage, protective bollards must be installed. X (/t, 17) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet thinstallation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X 18) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used until the final inspection has been performed and approved by a Mason County building inspector. X (34 19) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think such Jeqtures exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 20) All property lines shall be clearly identified at the time of foundation inspection. X 21) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X ((L4 n 22) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder hive prevented action from being taken. No more than one extension may be granted. X 23) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical repport/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X BLD2006-01289 Please referto the following pages for conditions of this permit. 4 of 5 24) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, r canner ors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 25) A koad Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (560)427-9670, ext. 450. The building permit will not be"finaled" until the permit holder can show proof that the access permit from Public Works has been "fine"and approved. X 26) Water X quality is not to be degraded to the detriment of the aquatic environment as a result of this project. 27) Prior to final approval, all upland areas disturbed or ne erosion protection (silt fencing or straw matting). X ty created by construction activities shall be seeded, vegetated or given an equivalent type of 28) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. x d�Z 29) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X_ 6 30) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X a"4 r 31) No foundation drain 30 feet downgradient of primary or reserve drainfield. V 32) This parr I is located in a smoke management zone. Please contact a fire warden at (360)427-9670 ext. 459 for further information. X -- This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. L q / OWN ER OR AGENT: DATE: ! b BLD2006-01289 Please referto the following pages for conditions of this permit. 5 of 5 W f o r rCONCRETE MECHANICAL MANUFACTURED HOME N * c�. date 2 1 1 2$l o f By A izCCD rn Footings /Setbacks Gas Piping Ribbons 0 c, irtierior Qa e 10 Z(i�Cb Bye Interior-Gate By Gate By N 00 Exterior Date BY Exterior-Date B � Ca setFbint Load!isolated Footings INSULATION Data By W BG t SLAB INSULATION r' Date By Date By FIRE DEPARTMENT r Foundation Walls Floors Date By 90 Date 6 to By sowe By DECKS > FRAMING Vas Date By GoDate _ -G5 By . 12 gala-,AL/—d7 BY2A PROPANE TANKS PLUMBING Date Date By Date By OTHER Groundwork Attic 1 —/—4p Type- Date By By / � Date By teto -a n.W.v DRYWALL Type: d� Int.Brace Wall Date By W Date Zi-Z S1 D 7 By i� _ r Date By FINAL INSPECTION w Water Line Fire tU Data 2 a V 7 By OCR-.,- Date By Date- � (r, By� o I CD 0) Pass or Request Inspect. c ° Type of Insp. Fall Date Date Mono By Comments n� AC _ tb MODE Ae A -70 Co Fao-�i PFlSS I°'ZylOb SC413Ac.&-s Aac- CIOSe EAvEs u BACle Cbe` m , — _ l DNS c,�✓o 7a 1 S��A/l a Cn Le (n 7 07 a-L07 t6-� .fie 4 G c ,e Ln CD j,1s % 1z?LO7 2 247 r4, L- 7/Z7107 7 -r cw► � s S-I. I i �,� 4t-�S',r�7 _L6�7 %f ort. ' lZ' s LFz_fT gTf/1' �f or wgjTo o PAW Z i12 z 0 � Iry ��� G��oF�� �',�ca v�Uo /�'tiG-Id!�/1/r✓G- �/1�N'7� /�/9�f 90(-Ci 1 a3c) (,t 1 000 LI Hodge �+ inc. engineering RECEIVED 8-9-06 AN 212005 SL #6-0707 426 W. CEDAR STe RE: 40 Skipper Ct, Belfair Hodge Eng. Project 6.0879 SKD plan Fathoms Construction Plan Modification To Whom It May Concern: I have provided the lateral and gravity load engineering for the SKD plan Fathoms Construction for the single family residence at 40 Skipper Ct in Belfair. As an option the builder may move the mechanical wall between the garage and residence to the edge to the family room bump out as shown in the attached plan view. From my lateral engineering the wall segment (3) is only 65% loaded in seismic design and has adequate shear capacity to accommodate this modification. This modification does not adversely affect my engineering. See attached plan views of the area in question and engineering calculations. Please contact me with any questions regarding this matter. V�1AR1j 8-9-0 ' SL# p 37886 John Ho EXPIRES. 121101 This letter is the professional opinion of the engineer of record and regards his engineering only. This letter does not allow the builder to disregard Code requirements. Any schedule or cost impact is the responsibility of the builder or owner. The Building Inspector is the final authority to allow changes to approved building plans. This letter may be signed electronically in accordance with WAC 196-23-070 and Chapter 19.34 RCW DEGK Ril �1 o I PECK TO FLOOR us % v W NOT TO DTIM�1" ,� MAC \V FAM I LYO cO F— 00 i n U5 � I (y�{ ��Q ) X x / XI O z S r fl �„ Ul "„ — "5 0 U„ z ;o •xlilb"\ R>o NAN6 JOISTS �_ HUS48 HANG D 2 ' HHUS48 U6 I SLOPE 69 I 4"xg" O4"x8" 3-1/2"Al-1/8"PSL 10,0 WATER HEATER — — — � �— STRAP AS REQ'D U3 w;, z3 U� "35 OUI Uw, 5 0. 4"x8"DF'2 ' IIV VEi25A- I I n" 3 'x N6 J019T5 r H+ HHUS48 HHU548 w N o U5 X \ x 2 � D1 ulo 6"xlo" a 4"xlO"DF02 \ Rl � 4"AO"DF"2 4"AO"DF02 „5 UI2 / Rig o UIO ?< :o 4"x8" U11 UF:f=E F-, FLOOF-, FfRAIINCH GfRAVITT' LOAD ENGINEEizING 26-0" s -o. �Y�c�i'`yajY s G' �-IN s o a, / 3068 7'-b 1/2" �s 6060 5L 6°xl2" cr c'r, z I-- O WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN Lateral Analysis.wsw WoodWorks®Shearwalis 2004b July 26,2006 13:21:42 Level 1 of 1 40' 35' 30' D-2 D 1 —�— - cD 20' N N M 15' v ............. ............ ' ............... 10, r� cv C4 5 ..... . ..... .... .A 1......._ A- ...... --- 0, A-4 ......... .... 5 -10, -110, -5' 0' S' 10' 15' 20' 25' 30' 35' 40' 45' 50, 55' 60' 65' I 0 Skipper Ct. Belfair, WA 5 of 5 q/tl Woodworks® Shearwalls Lateral Analysis.wsr Jul. 25, 2006 13:33:07 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Building Area Story Shear jibs] Shear Ratio Rmax Reliability Factor p Mass Ibs s .ft E-W N-S E-W N-S E-W N-S Level 32770 1143 4705 4705 0.638 0.466 1.07 0.73 Structure 32770 - 4705 4705 - - 1.07 1.00 Vertical Earthquake Load Ev=0.2 Sds D;Sds=0.93;Ev=0.19 D SHEAR RESULTS North-South W For H/W Fact. Shear Force[plf] Allowable Shear[plf] Crit Shearlines G Dir Int Ext V Pbsl V/L V/FHS Int Ext Co C Total V Ibs Res . Line 1 Level 1 Lnl, Levl 1 Both 1.0 1.0 517 21.5 21.5 353 1.00 S 353 8482 0.06 Line 2 Ln2, Levl 1 Both 1.0 1.0 564 23.5 29.7 353 1.00 S 353 6715 0.08 Wall 2-2 1 Both 1.0 1.0 431 23.5 29.7 353 1.00 353 5124 0.08 / Wall 2-1 1 Both 1.0 1.0 134 23.5 29.7 353 1.00 353 1590 0.08 Line 3 Ln3, Levl 1 Both 1.0 .67 1152 44.3 153.6 236 1.00 S 236 2297 0.65 Wall 3-5 1 Both 1.0 1.0 44.3 236 1.00 353 0.0 - Wall 3-1 1 Both 1.0 1.0 44.3 236 1.00 353 0.0 Wall 3-3 1 Both 1.0 1.0 691 44.3 153.6 353 1.00 353 1590 0.43 Wall 3-6 1 Both 1.0 1.0 44.3 236 1.00 353 0.0 - Wall 3-4 1 Both 1.0 .67 461 44.3 153.6 236 1.00 236 707 0.65 Line 4 Ln4, Levl 1 Both 1.0 .78 1061 40.8 66.3 275 1.00 S 275 5222 0.24 East-West W For H/W Fact. Shear Force[plf] Allowable Shear[plf] Crit Shearlines 2p Dir Int Ext V Pbs] V/L V/FHS Int Ext Co C Total V Ibs Res . Line A Level 1 LnA, Levl 1 Both 1.0 .89 1802 37.1 225.2 314 1.00 S 314 2513 0.72 Wall A-4 1 Both 1.0 .89 1802 37.1 225.2 314 1.00 314 2513 0.72 Wall A-1 1 Both 1.0 1.0 37.1 314 1.00 353 0.0 - Wall A-3 1 Both 1.0 1.0 37.1 314 1.00 353 0.0 - Line D LnD, Levl 1 Both 1.0 .67 1730 35.7 93.5 236 1.00 S 236 5124 0.40 Wall D-1 1 Both 1.0 .67 561 35.7 93.5 236 1.00 236 1414 0.40 Wall D-2 1 Both 1.0 .67 1169 35.7 93.5 236 1.00 236 3711 0.40 C-Sheathing Combination:A-Add capacities;S-Strongest only;X-Strongest or twice weakest. 0 Skipper Ct. Belfair, WA 12 of/ WoodWorks® Shearwalls Lateral Analysis.wsr Jul. 25, 2006 13:33:07 Flexible Diaphragm Wind Design SHEAR RESULTS North-South W For Shear Force[plfl Allowable Shear[plf] Crit. Shearlines Gp Dir Ld.Case V Ibs V/L V/FHS Int Ext Co C Total V Ibs Res . Line 1 Level Lnl, Levl 1 Both 370 15.4 15.4 495 1.00 S 495 11874 0.03 Line 2 Ln2, Levl 1 Both 600 25.0 31.6 495 1.00 S 495 9400 0.06 Wall 2-2 1 Both 458 25.0 31.6 495 1.00 495 7174 0.06 Wall 2-1 1 Both 142 25.0 31.6 495 1.00 495 2226 0.06 Line 3 Ln3, Levl 1 Both 1519 58.4 202.5 495 1.00 S 495 3711 0.41 Wall 3-5 1 Both 58.4 495 1.00 495 0.0 - Wall 3-1 1 Both 58.4 495 1.00 495 0.0 - Wall 3-3 1 Both 911 58.4 202.5 495 1.00 495 2226 0.41 Wall 3-6 1 Both 58.4 495 1.00 495 0.0 - Wall 3-4 1 Both 607 58.4 202.5 495 1.00 495 1484 0.41 Line 4 Ln4, Levl 1 Both 1154 44.4 72.1 495 1.00 S 495 7916 0.15 East-West W For Shear Force[plf] Allowable Shear[plf] Crit Shearlines Gp Dir Ld.Case Vfibs] V/L V/FHS Int Ext Co C Total V Ibs Res . Line A Level 1 LnA, Levl 1 W->E 1548 31.9 193.5 495 1.00 S 495 3958 0.39 1 E->W 1541 31.8 192.7 495 1.00 S 495 3958 0.39 Wall A-4 1 W->E 1548 31.9 193.5 495 1.00 495 3958 0.39 1 E->W 1541 31.8 192.7 495 1.00 495 3958 0.39 Wall A-1 1 W->E 31.9 495 1.00 495 0.0 - 1 E->W 31.8 495 1.00 495 0.0 - Wall A-3 1 W->E 31.9 495 1.00 495 0.0 - 1 E->W 31.8 495 1.00 495 0.0 - Line D LnD, Levl 1 W->E 1718 35.4 92.9 495 1.00 S 495 9153 0.19 1 E->W 1705 35.1 92.1 495 1.00 S 495 9153 0.19 Wall D-1 1 W->E 557 35.4 92.9 495 1.00 495 2969 0.19 1 E->W 553 35.1 92.1 495 1.00 495 2969 0.19 Wall D-2 1 W->E 1161 35.4 92.9 495 1.00 495 6185 0.19 1 E->W 1152 35.1 92.1 495 1.00 495 6185 0.19 C-Sheathing Combination:A-Add capacities,S-Strongest only;X-Strongest or twice weakest. 0 Skipper Ct. Belfair, WA 10 of 5 0/1, 03/13/2007 17:43 PAGE 2/3 Hodge engineering�+ Inc. 3-13-07 S7-0171 RE: 40 Skipper Ct: Belfair Hodge Eng. Project 6.0879 SKD plan Fathoms Construction Omit Beams R5/HDU4 Holdown Alternative To Whom It May Concern: I have provided the lateral and gravity load engineering for the SKD plan Fathoms Construction for Fathoms Construction. 1. As an option the builder may omit Beams R5 (600 DF#2). The beam has been replaced with a girder truss and is no longer needed. 2. As an option the builder may use HDU4 holdowns in lieu of the specified STHD holdowns. The HDU4 has a 4,190 pound capacity while the STHD14 has a 4,220 pound capacity which are both larger than the design loading. The installation of the HDU4 holdowns connected to 5/8" threaded rod through the floor system does not adversely affect my engineering. Please contact me with any questions regarding this beam and holdown. 3- John sr r 7T:. This Ietler 1s tt�et pro( anal opinion of the engineer of record and regards his engineering only. This letter 0whot flow the tij*tilder to dfs[$p; ttZode requirements. Any schedule or cost impact is the responsibility df the buit?ter or owner. The Buildin thspector has the final authority to allow field changes to approved !% ;!ding plans.This(titter may be signed e?eetronically in accordance with WAC 196-23-070 and Chapter waROW: :....<:. Vic: • H. 'i. i:L�:4.0 i13'a= °'- x- 0 pl j N 4'xc"OM 0 r RI3 RT T t� �� Rt3 TR155Ei TO TRM CO. 2N] wy a T�+ws =; i John Hodge,P.E. 2601 Jahn Ave.N.W. a R �< t Suite A-1 "xs•OF4 Gig Harbor, WA 98335 o ' Phone: (253)857-7055 - y y 1 Fax no.:(253)857-7599 =1 • • Oo SITE INFORMATION - ! ADDRESS/LOT IN 01140 SKIPPER CT. 010 r 8ELFAIR,WA GROUND SNOW LOAD R 1z4 30 PSF EXPOSURE 2 RAFTER RERS 25d2" S F X o B 85mph OTHERS F3Y O ERS �' SSES • 24" O.C. w/ SEISMIC ZONE MFR. �Et 8 ROOF j 16 I 4'x 'DF12 I w/8d a 6" O.C- AT D D 12 D.C. IN CR1 PROJECT INFO BILL BURGESS 6.0879 PLAN NAME/ NUMBER w zz FATHOMS CONST \�' BUILDING CODE fiHodgeen ineerin inc. g g 3-26-07 S7-0238 RE: 40 Skipper Ct: Belfair Hodge Eng. Project 6.0879 SKID plan Fathoms Construction Failed Framing Inspection To Whom It May Concern: I have provided the lateral and gravity load engineering for the SKID plan Fathoms Construction for Fathoms Construction. 1. Per the builder HDU holdowns were epoxy set into the foundation in lieu of the specified STHD holdowns on the engineering. HDU2 holdowns are acceptable in lieu of the STHD8 holdowns with comparable holdown capacity while HDU4s and up are acceptable holdowns in lieu of the STHD14 holdown. HDU anchors shall be epoxy set with Simpson SET 6" deep and per Simpson and jurisdiction requirements. 2. As an option the builder may use 12" concrete piers with 4x4 adjustable post base for the positive connection at the front porch of the structure. The 12" concrete piers are adequate for the loads of the front porch. 3. Engineering specifies PHD2 holdowns on the interior laundry room wall. There is no foundation or stem wall under the wall in question. As a fix the builder shall add a second joist under the wall nailing the two together with (2) rows of 16d nails at 6" on center and run (2) Simpson CS14 straps where PHD2 holdowns were specified. The CS14 strap excess shall be wrapped around the double floor joist. Please ith any questions regarding this project. �G 3-2 S7 S7 E Csf J 37886 ,,G Cs This letter is the,profe§s oriaf opinion of the engineer of record and regards his engineering only. This letter does not allow the builder to disregard Code requirements. Any schedule or cost impact is the responsibility of the builder_or owq r..)JThe uilding Inspector has the final authority to allow field changes to approved building plans.T ,s y be signed electronically in accordance with WAC 196-23-070 and Chapter 19.34 RCW g hyi.Ave N,,W Sty. Ai Gig IfaO)tvi WA .3�f,,,.°t . 75199 I Xw +s p N �I X n'TIn B RING WALL r N X N Ol 3 �° m D i6 m O E � I � I I x \ �� &XIO OF 02 O m 1 2XI2 C, m --- � • i MU] CUTBACK HIP MASTER A Oil I �, A N-4 mN OBI i, �O {=t3 09 n _ ON 6XIO OF 02 � p01 x� � I � r3 nrp N0 -- I O to - I m I -4 D 2X& CJ. - 0 09 - E 2X12 RAFTERS IIV N r N x10"DF 4XI - ��- A D c6 � r � HIOl-wtER g w N U L-j L 0� � oc0 O D N � m — -- — m 7-f -- N X — -- v~M"' A GI HI MASTER 2XIO �' N = NZ o 2011 10 D2 M4 30 4"xl0" 6 xI pF"2 4"xl0" STNDSR Uz U4 63 932 �-�T' 15 ]] 24 U4 2845 3998 P D2 �o ro 131 w O ' 38 L 1318 D2 STNDSRJ STNDVf;�ETE PORCH 20 D2 Hodge en ineerin inc. g � 5-1-07 S7-0384 RE: 40 Skipper Ct: Belfair Hodge Eng. Project 6.0879 SKID plan Fathoms Construction Holdown Alternative To Whom It May Concern: I have provided the lateral and gravity load engineering for the SKID plan Fathoms Construction for Fathoms Construction, The PHD2 holdowns specified on the residence shearwall next to the garage do not connect to the foundation. This condition is not acceptable. Holdown loading for these PHD2 connections at design load is 1800 pounds. To holdown the shear-wall to the structure the builder shall add a 4x10 beam at the location where the PHDs are specified. The PHDs shall attach to the 4x10 as shown in the attached detail. The floor joists shall have 2x6 squash blocks reinforcing. The A35s shown are to hold the 4x10 in place and do not take a holdown load. As an option to the 4x10 in the crawl the builder may install a 4x4 and through bolt from the PHD2 above. The bolt shall have a 2" washer at the nut. See attached plan view of the area in question. Please V'A-k with any questions regarding this project. 5 _ S r p �G 7ss6 ' Joh I i6� This letter is-;the professional opinion of the engineer of record and regards his engineering only. This letter ds, S-Y ot'sllow the k411der to dicre and,Code requirements- An rchedulc or cost impact is the rea onaibilit .. � 9, Y P P Y of The builder or owner. The Building Inspector has the final authority to allow field changes to approved ,building 016ns,This letter may be signed electronically in accordance with WAC 196-23-070 and Chapter • �.i 1T��.1.y��H'�IY �i :.V.,I��.�1.J�:M..�'4-�Jt�I1.L�I..h�� .ii..&A'y..Y ;'�(a<r3. .r£1AT'i ;%t'i. i`v��s'`>La�. .:`..1 �;:iri 's'c$�`Ire13 %1:� i,�,�;y'•�Ga E Z0 39dd 'oNi `sa�iQ-ling d w Z8b8S9Z8SZ 60 :80 teen/ze/se \ D2 m \ n tvT,, Lij S�NpSR , — �, �' -- \ � Mz ,i ?4 w z P D2 3Y#: H LL.I \ Q 20 J 3 f• D2 PCRGH co m SNEARWALL PER PLAN Ln LO 2cq m LD Z P+�D2 N 1Tl I---- a ll 2a rn � � CD A35 CD m q� J015T5 PER MFR. N 4x10 CF�2 m IN OON INS / ��lN I �N FLAN FNC:; INE Jul 19 06 12: 45p Bob a Patty Paysse 360-427-2353 _ p. 2 PIONEER DIGGING. INC. PARCEL#: 1 2330-5 1-00074 SOIL LOGS: 36&426-1803 CUSTOMER: BILL BURGESS SLI-0-60"m,s, SI_2-0-54"M.S. SL3 N/A TS T 60" ROOTS TO 54" Dob Poy�c CDc�ignei) DRAWING: DRAINFIELD DETAIL ROO /}lcr Poy�x(Dr°Rer' SCALE: 1 "=1 0' 0' 10' 20' PPMEFTY LINE 5ETDACK TnLti N PFOUE51EI7 OP5EP MON POPr SKIpmr,Cowr /01 Qi. 4 �. O- al n W WJ W u' u N W � jcz ci r j - l' U Q co � N O �_ U 5 \i, 0, 0 o � / L ,0 \ f � 3JI�jp blb,j13EF soot o z inr, i 51�EpEP SI.OpE Request To Revise An ___ d Plan Permit Number: BLD200 -_ p/2-91-1 Name L L _�, L4 ef-S Parcel Number - - Phone Number daytime 3 0 620 Project Address Mail' Address Please provide a complete, detailed description of the proposed revisions to the approved plans: PH pxtg Are two sets of the revised plans or addendum indicating the changes included? ❑ Yes ❑ No Are the approved site plans included? ❑ Yes D No Are the revisions clearly and accurately identified on the plans or addendum? ❑ Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes ❑ No If Yes, Has the engineer or architect approved this revision? ❑ Yes ❑ No Is a stamped and signed approval included with this request? ❑ Yes ❑ No Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record.) Does the proposed revision modify the footprint or location of the structure? ❑ Yes ❑ No If Yes, Is a revised site plan,with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: 17 Applicant's signature ., Date: P o G Office Use Only R ived by: � Date Sent Assigned To Approved By Date Original Valuation: $ Additional Valuation: $ P. V ZS Sq.Ft. x$ $ Sq.Ft. E. _ Total New Valuation $ Additional Fees: Additional Planning Dept. $ Additional Plan Review $ New Setbacks: Front / Rear / Additional Building Permit $ Sidel. / Side2 / Additional Plumbing $ Additional Conditions/Comments: Additional Mechanical $ Additional E.H.Dept. $ Other $ Total Amount Due: $ Amount To Be Paid Up-Front$ 7ah ioi�id Revised SRG f22r= f-WCX--I Ut;e f3K 16, F'G. 20 RECORDS OF MASON I I COLINT"r LUA6kIW-jTON. ly Lu L6 C=; LL. c— (=> 0 tt— (Y. Ll i CQ 14- A U. J LATTICE LLJ go ALLNINICI 4-5— 334— CONCRETE\ LUALKWA*r 15 IRON BAR W,"PLASTIC --331 YELLOW CAP SET cb 99 FOUND AS NOTED WEST EDGE OF LANL:)-r,--AFE NA -,t- mm 7.3 74 7a cn FOUND 314 FOUND -1/4 IRON t=lf=E IRON PIPE FOUND 314" IRON 036 SOUTN 032-ACkjrN FOUND 314" PIPE UNDER/a" 0.13 EAST 0-07 EAST WON PIPE 0 FALLEN ALDER W1 TAC TREE 0.40 SOUTH ZO lsrE 45000 PLAT 031 EAST 120.00 PLAT i I/ , --. - 120.00 PLAT 91.63 PLA T IREMS I N 89'0931"E 06-048.041)r� 06-048.6MI SURVEYOR'S CERTIFICATE T1415 CO MAj- FO;RLp VE -I--CTLY REPWSENTS A SURVEY MADE BY HE OR PR0FE5,4Ir7NdI I A.— Lifebreath deliverspieta indoor climate control package Your Questions Indoor comfort in a small package Answered the pamtd ufd,mth(Inn Air FitrnoN a,n h,,the fie h air hn>ia semenm vea8atio,and,,wady main of warm mt for the belddex. rpt371�': SYaa((Oafrc t:Iffttl4k COMM 1'3lLe dfJ�lU:l J{BS�S�lhfji 2 Q:Can l�re myeai tirig hot wotrtonk7 rod teak f rnu,arn only ore when of the Hat Rw y Venalaarr with,he cnmfi,rt and effioenq of the ,mforeable home earvimmrtem p titi..IN,I—with a y-m waat ft;h-WW-to a 'IM C]ean Air Furnace aAow, r the addi- WhOj8•QOUS9'Vi!f,�k$lf9.'C <~'.��; :'.'+i . mmra . rp. q-. 'hr L,kh.cath (:lean Au Furnace water it head,bnaur warn i,)n obk Llfebrentb'c:-patemed+ alomimmt ire t:: tion of a pkmtm.tinned air a,nditi,mn. Add a Lifehreath 16'P Air(7earer m ynry 'f +%.::�'•+!".:., rcyuvn a warn nptr a tprro- water hater/air hardier.Ihie c,anhtmdno hating ryxem pnrvido effiaetcy afup m 9DX ?;• heasr m $late m hold xti heel mirrul,at is ern e d, deliver, oekal itl h t reel A,ling a the ii—n wnm,Aed by a ht.oi g atd venahmn eyaem ihr warn heater wtA he rite rourcr of nuc rest With de tikb,rath furro<e,rite Rrh etrtryrrhtentw ' ahga ai. ;;,• neat for the home,o mar he eapoble or water to ehc heating ma i,bang heat, lee rate Wmin heal : the--,with a fart auo,/on twtech.uaav li,r a,mplete c1i.: row :: :::;: �D% ro r.eiaen 1. Warm.axle air firm the home i,reaatrhed a, `'• r• halt fvtfilling both oc furnace satin i -olt e,tdiry m h Id mint �y to rbr row ,elect hating or rnaang with w:nala- quabry contml. IM 1'FP } •:�5:4 :'. ', 1.6' rnrnu nk the Lafeb,eath ckm Mr tartars n m� durable- tmn to mee,your di—canard reeds in m parse � very ethrirn,iryacm,andnhydt fi,ency rWuNer from!teak and rcdovivu dap 2. Chaoioar air aavelr thmugb the fm,as Ai,eetirm care thz„ the every wa.tan. Rmdnuom,ly, and hke d..— watt het—will It—& the hexing can in,he h—,weal not c }} y�, f p intake and u bwght tnai the integral HRV. .+" P LAed by nehet--. elect xnic filte p easel k "};;+•/.+: amyk Im,weer Confirm the•AN..y ..:. J. 7M 6e,h and rbk air pow thnmgh nppmae fimca,m heating, ofy—hcatcr,nlh your dealer. ?Deu lYe eMrt my,Mr taatppanlet::.QktetOg.:: All aha,hteely a,rm Ih . •`::•'.::: ode of the HRVI a1—i—heat exchan - nmi and vemai don the fiK air:1—capable, ••}•:ear :{:,f}.4`' MetrwmtyrT $� 5. ath to 9 a}:�4:MIIIIiMhF m.„flee lfk..+.. excaliiun peen Lt(ebeath a their :::::.: '•:'>: .. /•,•,:: c' � .... + can be row -'+ vf9,.l' ;•ti%' Q Will ledwgskpre ontwgh hot A: Was!hewn n d..-it hnnnurodo- .:::::::..... controlled grvh,tt your fa ly what ::, •v '}f;b w•uh the inaalla,mn of comhie :::;j}/ ,':ain:':. V:::'r:;'iC; wrte/f waranry :::ijiYfli�' t* 6. Hot from elite role as v aamkrred a < SAS±; hr m t•>w thetmo they deserve dean ::/ ;.:S• D the ....... % .::/ '''' A. M inng a cr hea,er it accords ern heating .::.::Ye ;e•:' .:i:': ebriwrro toe fmhair. : :.....:: .... :r,. •: k#}' +i<`:•,•: <5: .:.� - «.;... .... hnlehy air 1.every mend ..4g ./'L.$;:'••:} :j;is:+yS;:y+4a:}/%;?; Norc4,hnar wdl always br plerryorhat rpe .. of a rrbrcath CJean Air .... .::: • ter ,}... }.:.:�`''' f.n'�••:''::>:;`•:,•+.F.. ''o:'':•++•�`:++• -:>"' :•' 1leohe S. Sn1e air it exhauxd autn'de. :: ::. :: bl me-' : % %F �. !:^.>.t wan fin namal usage Wa,n du,circa- Fmnre mercahn nrcubtlnn,n ehr wain y iitiltYVlitNllfiilikMlSl - rarnw.r :: reel m rcdan heel, A snits4iufi{uY at ,hmugh me r ma a mu m nratn,it rmalg,r r'•'" Meanwhile,In Uliebreatlh,dtra-e"deit } non .Jrwcd in eaten,drpoaa. . 3SSLA:t6f:!}tf.Sf}!i £ {}�. wstdd,c Fate tin heatnq cowl: ... .. .p�bY %t / uMorngr ,'hr'N `••1 6. Ha wain U utx Fn,m rite parr ham m IM lafdrma,h Clan Mr Funua fi - .: :« i dmnu i rnrgorariN Or Douth.reeterheatr hoes robe r aNPPed d'rW e„waY niopmi:Y rt higher tenpw.atrot 4 r : the firtacc hatiryt mow. Blew tiSA vridl _ .: Ir i 9�� • 5 .•S tk New teeth wN 1 eaoe en m) A: The waar hears th.Wd he run amend .. o little7. A PSC type for hiwh fflck y fin hl—the ..... '.. .. t._:_. > :.:: ".deee btanWRy 3eud+atit edte.dreondhuo,ea:: ! fS/%( lin'F, a c • tempered(redh air kom the HRV irxo elite "�:': ` A:TThh dr ends,n —Illz ern the us of dontrm, teen heasrtmRunrt ergthe :t a-wheel f wwr home and the heriryr w—you hewn at a higher am,pereurc A potable Weh a Cikhrnth clean Av u Id Balm. S 5 z ana r •... B. IM drvaUtlon pump ditribttm,hat water .�. ... .:: � � ; ar�s,N. ang an :.:. 1MeMlw :Ile.stiles xf the CAF tow. .ate emtdpk ./..¢... Fw d a hhglh Mrirncy dromgh dhe run. .. .... ::: �fty:%_ - 'dhpe'{m npo!a,i{iihidoan w i::: :': � heater,you could uvr,+much ax.irM,nF 2 wg1 LMebrerth alreq keep.) r .• ..:: ::::::?::•:jai+.... 9. 7M it al ti hot was,hem the as m the r :n��:: .,::.?: . <N.ttistey: ... r4ri;y m,�n,ah,m and:dryrm:Imm.:� .d,"l14 m� : mar NO hill.by rn,rrriy boa fimr house w.n.r yg .. Beard,empenare do t11 alt.:" end hv,uWiey fain atWk,ary -Z. :,� i � o,epang air.dr I IRV ache•.ugnih— A: The high-cat ry heating cal to the t�111Mr1[ to.Warm,f--1 an„drerihteed to regiam : :. rnevgy miryp,at wen n dr chin ern,hr tifchrath Clean Air Fumam a sized m thnmghout the home fjpi,e{r t tan.kited the cxyhay t ailaaePllt .. h,x pap!. en warm and to dr-Wea wnam w ay... ►�4M. 'I10 ono A ar in d anmckma 4 nwea,htt Propo•r v erg ofthc aan her<n It.'IM 1..water—1,through the coil and Mu,artl aam,ma,hte cosh �} r m the waorr hrmer for domeac a,e � ::.: ::;..�:.::• •:;..:<•::.p P.Do building weloo iciele.pp,on d w,u rntrtrc m r an,rmt 1" 11 ..... .: .:;.. a : with Mel the cyck cord .Ilhe w:nalaam romp.- - - .a.a.a��.,t an m Ut n d.ash pp— Caen Lifebrteth G)R be..it .:nest work,year-mead m snare that par home n �CM:vtaertt ualL, of ro now hnana,f* a hoe weer errn.e etlw - 2�} .:........:. - mx Alt ugh b king ode oifitiak as dtarmstk waterhMerir . :ahvay+fiedh,while the hwda,g Ftinmon apeutn ..... ..... .V .. ' :. . .... ....:::.... '11re etemie.,attdde.ieW de dr!nlu!ver0a. :'i>::::.4:::•: I at Fvn,Aar with there fu.nur,ax A. Yn-comulr par drain fur infixnraoon urdy when retpvrd,ergrry the rnmfre oa,tm- e:. wink::.. ...:. _ ? :.::'t}�sj>:.. KNdhea4MMtoR: of ern hoiln a rmnho radian,noodfnmcd •..:•, �:.^ y 1 n der faro pr dun dear cllnn A nienca and too—W of a Likb,eath Clean Air . a Woo,7wbng( +bFd'er[pt+.:: .::..,.:.,::.•:• oedeo totereAla n n. ..... .,. ... Rt►:F:•`.jj:2': n way rhr ear nptiont. F'ur,ace. rrtoddr2 anedab6:wtl,else tzrrAml CAC:fhe :•a•:;jn:• huh m,fi.d ... .. .Ire'";jjj:F:yi ..I , , Alva AW,m dur,dwv a,d horravraJ wodrh :'mlyalffiioahbt feBeuNttwatafji bwlmpttet .. �::> F nu d Li A(: � I Furore drrymed and ,f elite ly/,it9l,e,za& - elteep �cordvpt pain.ad,m7 mnGa& Cate aYdhM,dr;M wWedt A/ny rroear,be odeh atdklte fitart 9 3rW as ktiG " : - n`ddna rkrn rnakd For ar with hour- A. added n a enF't�te• n,h inn way Save money with combined whole-house heating,cooling and ventilation aw:ztepintae Sf vitlid : $ ` as"caowill l.eel m any fa,rtd air Fint-year mvkW of S1,790to$.J,000 .. . wptnaho zzli6hJ ....... 7M ukhrn,h(Inn Air Furruce a amoaryt 7 e hwl,,.heat,reawery.e I—,o.<, ... ... ..... ....:: -t ..., wit yo r eu _ oadeuan. �D etng oil? sin ... .. ..... hart t :I mMn,m�hraong nsma do not �It m , wMc,weha anyc ,he maths cient heating,coaling and yw money wMe impnwmg your health.D- �• r a' ►eg[ed for](fM, _- rceuk W tale fixmayt on the hraang venalaaon ry— available C mp restive nsovering energy ham oagtoirhg mthe(iAF' nppileatiO ! too ham 1-.o tut Ldebreath ,fkn fiat- III.O112Dn $535 :: :.:: s,• ..maker wdxde-h,mte vemUtiw af6udabla - :; .:..: ( u ate year,wngp ircludiryt eapapmea.nrualla- ermtrahg a,mmmvm late of energy m the ........ '•<.. %y: o(il.nnmL1,A00 o,xdnur..'Ihe chart on the ht!bow, 'Sbttre Y'?62 p��!y„ tan and opmwg ono erg ::• ea ry .Minneapolis S393 _ rwc nunp 'eve aan,. ,ypid .e„at'gym ,avahg enjoyed m five •� .... i•�: . North Amuaao.tin from the a—Maid m of e For example.the clean Air I--,.doom's a C:lnr,Air he—vtawn—1.rion with- Toronto $363 I .ar.a oar.Unlike conwenavml e,macn, out hearrmrverv' Miami 9229 t,e C:AF rem,ve.w energy fi,mt a do r— a water heater.ha,s a heard oar a .,t TMr mwr'a tk slwn away my.,'rr anmd SSS ado a00 600.:. �` inrniddam o>m are . f,hma mvwry dxra,,r warlMam a,m meruyt .. :: - .. eyaad r is fire act hair,wa Wr r k,m T a xtr,� wxaf It, 3feNirtYhtl ttttditlrdlle: A �i hwhvcd by at m„dr„t3Do. wow ath kw hat ;#;;:;:; ::;::'•;:i;:: :: ... : e.w. L E,z 3>' #S€� P Sf#a4y Z:E' ..... O o � v T°n ® l m A-fav� I -T I- 61-7 W- A fresh new heating concept Benefits for your health and your pocketbook -------------- LIFE- Energy Efficienny Awards X.. X M: j A?3t f82MACK.I'h,Likbregh Ilear,A!, (b6K G."r,HYdM*Heat . ......... ......... . heellbi.,-re-.ffirtabl. The Lkhrath CAF ch-h.-.trady arcs f rafx..terep- ............... .bile lowering energy bill,1. with X hilth-.1fici.-Y waver l,mter,&i.-birido. -.n.-de rnnaendmal tomato which eres,pmd.h.., ; ,Y :-. ..M....i.......'. . N.....- 1Time head roil i"ici a', .. . .A.. ...ice. :9tldhtnd e,*e:in the comm m-ha ......... ...................................... g Ufeb th ap-0040d ,g Y md j4tidetly,lil 6 :::::: & ........ S. X -Ath :�M.-M ............ A, The UN —he-hi,hardIrr f.--ftao Men. aak it h*h-effi,-,T h.-, raleat.d thrt.$h-iAt h��:itodijAIMS ....... AA ..d-ei.k A:inbire ev-i far� the CAF h- 9(rx,CAE -kg .. . .......... ...... w ............ .1 W.M: A don.With.:(2tirn Ai,F-cam ............................. it—a the rM6- -lahle. N,Aeh B..d, Inc.,I., d-kp,r f the ............. ....................................... ........... i. h.ni,01 ...... KwII reep b-fit, month-h I-rr Ufcb-th li-fdi.....d air qaky,- ................... hty . ............................ �Iivy hin, -1 prtad�i, -,Id leader i.be i-.- iroy i.p,,M.l f.1d ,f Id.-Air Q Niwlt.(I Combat asthma Fresh Air Vandatim M.."..t.N-M k and othef rospiratory proW60v P� low ............ form-"Swige the q-1ity of the ind,wr air we bmatb,.1. ;;j;:.. . . -... ; .1 li'd.y%bit.A. • Ikbr.1 CAF- &I :,:: .............. addition 0, 170.0(9) Hear Rec-ery he.-At ho,ffi ir�,talkd at- North Ame,ri- Lifth-lb h.i-.h--d M,i--d This ....... rew 1—h % 'MAC Wh'k hMW-1a, ... -X ....... ......... pmd-e, dwI'WAir(I-r,,dthrCIa- ...... tv-"JrdrTTIkV.h- Air F--Vi,il ye---d.1-.,1- it. ................. ......... me VW ............inm doe . ....... ... ...... h- -k.y-I.-bealdi- Abbe,Th�.pocft&km�a*[OrCAF-U,94XZ4,PlgdndCAF.U.L44-36-PIO M�. WPOW2 . .............. ......... verad—MOCAF FokYbrrlytlenm&4*Wa*and OIPWmodobot#WCAF, SC ........................... .ti..t. 4ho h Iftftch W Waft WWWWatame.61— Siderthave Eva i CAM ................. be Mifi fb P—i .,.,r..C,� .... ........ ....... ............ ......... ... .... ...... eif: ...... 8— our p.,the Li"-,h .,ba.-.m!wteaawl6Aoe CAF e--d. kty i. R - .......... I . ,, M . I I I : :x.-.. ,::.,: -,An i-e.blera.. t — NRTL lord-0* ""Meek PW . 1,AI [t,MII. .r h X. X lr d by up w ling (the dl6detace All ..d alkagia:i4fbiz:aiw I'a F., ...... ............ ... ... ..... .,J.kr ....... -A,..-d az The-Va.d. .............. A-W,,d.. N"'-,w- LAkb-th CAF akc it ta,P.-Y.qW,voingy.011 lb .0. ... d: ..,.R h.-A,.,Wd diti-j,g crion'11,r :Ade s 606 Ai dun:r:wtam .............. F aehr=A, ......... (fiRV) ......... Tk r1e. Tifie Lif&read,C F ............ rn J..X I&Likh.-h p-ridma, The HRV VVM�,9WM 0706mald air 6EIVE::::: d.,-A..4 liki- hr J..i-.beat ZZ.: X. lnnde de h- the A,the a- --er, -d A ant yea d times it d air fi..,.F-4, —.,Y AN echr, CA 1, ... .... th..iih-r be b.- yan .k-d it A,the two air wmms Pax through die HRV. E.Y Maiet,eaeaice ...................... h-f.,m tI.warm.rtkir i,0-11-d.the The Ufrbeaal GAF i,d,,-,d A,a I-nuinernancc.'lily fi-b air hefi,re being diibAted throughout —rd w-X.-A,ma..---he PlIf-ard Ai.IVIY d dClean Air Furnace -.ed ft--111-tf.Wd he checked rc,.I., Y�)—1-typiml IAW M.ft h-C.the air and q.irkly.The pk M-'VD of a .... ly d re7la-d A, erdei.Th,I MV/URV ,),..Id be rka.rd ISO �ItG'"hoW i,.-pletely b.,.gW -y r. n u e c h �-:—M= ..... N�.h R-W.he. am aliva"breeahig healthy.fiezzi air. MASON COUNTY PERMIT NO. OVO([/ BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICA T I F TION CONTRACTOR INFORMATION Owner Y S Company Name Maili Address i 7 Mailing Address City 6rT Qr6 State WA Zip Code City State Zip Code Phone ( 0 t h'AAPh. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address rn-17 Ad E Mail Address Drivers Lic. # Y;3 DOB Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic— Existing Septic Connect to Water System __"� Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION -r12 Di it Parcel Fire District Legal Description / 0XV Site Address (Please include street name, street num er and cit ) erections to sit Will timber be cut and sold in parcel pre ration?Yes 09/ Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs /o Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement ac 'on?Yes/No TYPE OF JOB - Newy Add Alt Repair Other PRIMARY RESIDENCE,NJ SEASONAL ❑ Use of Building Describe Work No. of Bedrooms No. of Bathrooms Z^ Square Footage- 1st Floor 2nd Floor - 3rd Floor Basement —Deck Covered Deck Other Sq. ft. Garage ' Attached _>iL Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have!obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or ay�q s ion is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINU�IT KK BY MEANS OFA PROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APP CA DN. X "a✓ Date: �' Z o v JUL 2 0 2006 ,,. Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: a e I OFFICE DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department El Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee 73 Site Ins ection Plan Review Fee 49 EH Review Fee Plumbing & Base Fee - v Planning Review Fee Mechanical & Base fee Other - Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation ITOTALFEES G)oJ-, r MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair(360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICAN INF RMATI N CONTRACTOR INFORMATION Owners ✓bicircr10420fa-e Company Name Mailing Address '�> Mailing Address City C tate IN Zip Code City Mate Zip Code Phone '__ th h Phone Other Ph. Lien/Title Holde n Contractor Reg.# Exp. E mail address _ ,a2? - + .�- !i ! E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic� Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. C;> Fire District Legal Description ` _� ` p 3 Site Address (Please include stre t Wne, street n ber nd c'ty) r pDi e to site t� G l�/, r c L Is property within 200'of Saltwater Lake Riv /Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New ✓-. Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage `_ Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric__ LPC___ Natural Gas_ Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer ! Gas Outlets Kithen Sinks ) Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OVMVER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other parry in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X 3�ry' Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group-Type Constr. Planning Department Environmental Health Department FEES Plumbinq & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas /Pellet Stove Fee Other Violation Fee TOTAL FEES