Loading...
HomeMy WebLinkAboutBLD2022-00372 SFR - BLD Inspections - 10/14/2024 615 W.Alder St.Bldg 8, SHELTON,WA 98584 r;A MASON COUNTY SHELTON: 360-427-9670,EXT 352 COMMUNITY SERVICES BELFAIR: 360-275-4467, EXT 352 Buildmg,Pldnninq,Environmental Health.Community lleilth ELMA: 360-482-5269, EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspectionhhp Permit Number BLD2022-00372 Date Issued 06/09/2022 Issued Project NEW SFR (ADAIR HOME) Site Address 720 E Mason Lake Dr S Applicant MARKARIAN CHARLES&BARBARA Contractor ADAIR HOMES INC Contractor Phone 360-352-8571 Primary Code UPC IBC, IRC,IFC, IEC,IMC, & Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final _ Building Building Official: Community Services Designee Department Concrete Setbacks r1'-Z Slab Footing Perimeter /013/Z7 --rdL Point load Footing 15 S�zz Footing Interior Footing Decks/Porches S'a0-,�k( LDaD Foundation Stem Walls // -7 Z z Other Rough-In Groundwork Plumbing I Q13 JE0 Framing p Z 3 Groundwork Mechanical Plumbing / Z — Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Z q 1z,3Te- Underfloor Ta Other Insulation Slab -a Ceiling 8(L Floor Vaulted Ceiling Walls -(p-L Vapor Barrier , . Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building 161 2Lf Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other 44+- R%-'A 4'n uu&u �� ;k Not- Z,c�.d� J I lC � 3 F) C � ,4-- 4�A a e e_-^W ✓1 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Be lm ext.352 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: (jG-P Zp Z2— 00 37 z ADDRESS/LOCATION: —T'Z-p E W z-s Q lee T;>•- S e—?✓a ix UteLi ;77 • e ✓t Gt 4- r�.e r e fc/� 4✓wl a + a4W l l S s. t a-� vet q ✓ Za 1-2- W (/lr !a gr� k� t -F1.` Sa n e,� �3 ?tvs I�•tt,45 �Y-cSc-•�� 10 We(It 4c-t.Acc a ro• Ite s fisted above must be corrected to gain compliance. THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed bove are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. [� Make corrections, items will be checked on the next inspection. OK to Date: T''7,1-LZ ❑ Please contact our office regarding possible Department: t,D structural damage incurred by recent Inspector: i "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 36 Be ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: RLD 2aL7- -oo A-72 ADDRESS/LOCATION: 72.0 E ,444jLj Ir,& pr 5004L, (T'LMad uojs FINDINGS• ti m l� Coal �f ��rs,a�fiiun dnce— Vile r:s A^*( " &-1&r AAd 6Ar-V5 Aft— i hA"— Nod' PnuT Items listed above must be corrected to gain compliance. ) THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. 21 Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to Date: ///Z IZZ ❑ Please contact our office regarding possible Department: fl D structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC 14.12 MASON COUNTY 360-427-9670 Shelton ext.352 67 Belfair ext.352 COMMUNITY SERVICES 3 0-275-3604822--5 69 Elma ext.352 Building, Planning,Environmental Health,Community Health 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: BLD�07:2- 003.7a ADDRESS/LOCATION: 120 E MA'SO^) LRe 9 FINDINGS: FOAM i S _A-L— To 3 tg, ro�Pt,arti D faun k ► C, p►,��b;�, aSS -it-IS 6Wy- V DO 11104 Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. ❑ OK to Date: 9-13 ❑ Please contact our office regarding possible Department: &-�r—> structural damage incurred by recent Inspector: pep "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 N C Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: aLP 20 Z z 00�3`7-2-- ADDRESSILOCATION: 720 E ,!tAz a, A,C, p, FINDINGS: 6 1- .26' s4-s Aw- ma,Zn l.c.vti.( r,tiw Su,-k,►i NwW Wg&,n ovt.r N Ae" ./ f3ort.d -4 a A C C.ry ,AA, 4U R&- tiler k, 3a, Wokcs aft- 86 -9s a t- 'i . Lo&6 rmt v%64-e- lw aaa jpr A.e- s j?,u i � 4 T Re- R So 2.S 2 So 2 S. t2 0 J Ant- o,-tt aUt)Ak- anal Na+- ;�-rrh 4n -& A-)o4cLAd w, ih Inc_ 'A A J L Wk-. 6,-e— . (10) 1 L 4 h a n 5 �TZ.►�,�jzv9 M Nrl..cyl LAJ Z 4X,u O")"�_ kta,.,,�e.46w CAr J-K an a- d 1=02 l4-, a N V-ex b ez,C �i'hew bn S aY, y, rt- yywrs" L Lq K s uy,", 3 f-zed Pat,*, ak '("a -Le 0 h61�4 S.a e C-n0 ec_ d 40, 3&-,A u.a,R Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ® OK toMa; (tom S�- I�SA�-c �trn ewcc_ Cvrn_� Date: Please contact our office regarding possible Department: 'QhD structural damage incurred by recent Inspector: -J-je, "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER:�)\Q\ 2ZQ2:Z,—M31 a ADDRESS/LOCATION:'A 2,0 E, f\) QVA L-Cky vt FINDINGS• v vu Items listed above must be corrected to gain compliance. EPI�IS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: ❑ Please contact our office regarding possible Department: 1�- structural damage incurred by recent Inspector: �/ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext. 352 360-275-4467 Belfair ext. 352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 h°E Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: jXePZ0Z7--0Q37Z ADDRESS/LOCATION: 720 C AO Sokj L, %te P)r-.;S' INDINGS• _�,�e►� S��`rS t�,ec�s f� O� Tess 4G1 �5.2 �r��i�ly .=�s►�.� �c «ra tea �� ,F� /,��a� s vSe �.s►Q.a!'rS b A a f Ar 6u1-c. off/' ro ,4�c Cm hoc (e�(� .SE ,�h S ere(t er � Items listed above must be corrected to gain compliance. THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. Lake corrections, items will be checked on the next inspection. OK to Date: 3`l/ `Z ❑ Please contact our office regarding possible Department: t—)P� structural damage incurred by recent —� Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: WgD 2.o22 - cUo,:�7 2- ADDRESS/LOCATION: -72_p ,L( kSvn Lq 6-L- -Or S FINDINGS fir: ��z r•�c/�c�i�,n �u�,.nrl Gn 3 61 �2�f S k,,.►sJ �i 1--6w hew\- ?>,L n [`nrv. u Ld . 6AALc-s S trOOA Cc f Conn l.✓t (-.r-.,o4_ s l o p&d 4*L-wd Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. Make corrections, items will be checked on the next inspection. OK to I°orrmp °ec - s Date: 3 118)ZN Please contact our office regarding possible Department: LD structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 INSPECTION RESULTS Pagel MASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 w Alder St,Shelton,WA 98584 Permit A3N,t—CenteS BWding,Planning (360)427-9670 ext.352 Application# BLD2022-00372 Application Type NEW SINGLE FAMILY Owner MARKARIAN CHARLES& RESIDENCE BARBARA Parcel# 221085000042 Site Address 720 E Mason Lake Dr S Grapeview,WA 98546 Inspector Inspection Type Date Status Comments 9/23/24 NN O ACCESS-ACCESS MUST BE PROVIDED AT ALL INSPECTIONS UNABLE TO VERIFY ITEMS 3 AND 4 FROM PREVIOUS CORRECTIONS CALL FOR REINSPECTION WHEN CORRECTIONS HAVE BEEN MADE 3118/24-JQ 1.Per previous inspection conducted on 3/11/24 Items 1,3&4 have not been completed please address 2.Northwest side of structure grade,Slope grade away from foundation current condition grade sloped toward foundation smoke/co detectors ok this date-JQ MAKE CORRECTIONS,ITEMS WILL BE CHECKED ON THE NEXT INSPECTION OK to: 180 day Temp Occupancy granted no life safety issues 3-11-24 DEC /YComplete stairs and decks Nicole Norris BLD-FINAL INSPECTION 09/23/2024 FAIL ,Post address on house ,?'Complete installation of appliances upstairs kitchen yYCorrectly install ducting to exhaust fan above stove upstairs Repair drywall under downstairs kitchen sink by outlet 71n downstairs half bath repair/seal drywall at cleanout I Provide L&1 electrical final Seal penetration by heat pump outside Install bollard to protect pressure tank in garage 16Provide and complete WSEC compliance report and post it on the breaker box Make corrections items will be checked on the next inspection MASON COUNTY INSPECTION RESULTS Paget Department of Community Development 4w COMMUNITY DEVELOPMENT 615 W Alder St,Shelton,WA 98584 Pem t Ass t-Cantu,ewwvx,Plano{ (360)427-9670 ext 352 3/8/24 NN 1.NO ACCESS.DOORS ARE LOCKED AND NO INSTRUCTION ON LOCATION OF KEY. PLEASE PROVIDE ALL ACCESS INSTRUCTIONS AT THE TIME OF FINAL INSPECTION. CALL FOR REINSPECTION %p,c 1Cq � Mason County z Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us B DD2022-00372 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: NEW SFR (ADAIR HOME) ISSUED: 06/09/2022 SITE ADDRESS: 720 E MASON LAKE DR S GRAPEVIEW EXPIRES: 12/06/2022 PARCEL: 221085000042 APPLICANT: MARKARIAN CHARLES &BARBARA OWNER: MARKARIAN CHARLES & BARBARA 17020 136TH PL SE 17020 136TH PL SE RENTON, WA 98058 RENTON, WA 98058 1.206.856.3712 GENERAL CONTRACTOR'S LICENSE: ADAIR HOMES INC License: ADAIRH*262R2 2303 93RD AVE SWOLYMPIA, WA98512 Expires: 01/09/2023 360-352-8571 VALUATIONS: FEES: Paid ---IIue`' R-3 VB Residential, one- 4253.00 $630,847.49 Building Permit Fee $4,731.62 $0.00 and two-family Plan Check Fee $3,089.13 $0.00 U VB Utility, miscellaneous 1526.00 $91,376.88 Mechanical Fees $136.00 $0.00 Covered Deck/Carport 145.00 $3,190.00 Planning Review Fee $240.00 $0.00 Plumbing Base Fee $25.00 $0.00 State Fee-Residential $6.50 $0.00 Technology Surcharge $163.84 $0.00 Mechanical Base Fee $30.00 $0.00 Plumbing Fees $194.00 $0.00 Building Plan Review/Change of $125.00 $0.00 Use - Onsite Sewage Plan Check Fee ($13.58) $0.00 Total: $725,414.37 Totals : $8,727.51 $0.00 FIXTURES Qty Mechanical Fixtures Oty Plumbing Fixtures 1.0000 Furnace(s) 1.0000 Number of Bath Tubs 1.0000 Heat Pump(s) 1,0000 Number of Water Heaters and or Vent Printed by:Amber Selby on:06/09/2022 02:45 PM Page 1 of 7 Mason County Mason County - Division of Community Development �1 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00372 Qty Mechanical Fixtures (sty Plumbing Fixtures 2.0000 Dryer Vent(s) 2.0000 Number of Hose Bibs 2.0000 Kitchen Exhaust Hood(s) 2.0000 Number of Clothes Washers 5.0000 Spot Vent Fan(s) 2.0000 Number of Dishwashers 2.0000 Number of Kitchen Sinks 3.0000 Number of Showers 4.0000 Number of Toilets 5.0000 Bathroom Sink REQUIRED INSPECTIONS Setback Inspection Framing Inspection Footing Inspection Rough- Plumbing Inspection Foundation Wall-Pre-Pour Inspection Mechanical Inspection Underground Plumbing Insulation Inspection Slab Insulation BLD-Final Inspection Shearwall Inspection CONDITIONS " All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. * The foundation/footing must be placed on undisturbed, firm-native soil. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. Printed by:Amber Selby on:06/09/2022 02:45 PM Page 2 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00372 Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. Printed by:Amber Selby on:06/09/2022 02:45 PM Page 3 of 7 �IG `'`' \ Mason County Mason County - Division of Community Development ��--� o � 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2O22-00372 * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360) 427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Amber Selby on:06/09/2022 02:45 PM Page 4 of 7 Y ., Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00372 A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient (SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, " WSEC 2015 Certificate" and are available in or '/2 sheets. The Mason County Permit Center will also have some available. All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. • All property lines shall be clearly identified at the time of foundation inspection. • Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. Printed by:Amber Selby on:06/09/2022 02:45 PM Page 5 of 7 h Mason County I��a• { Mason County - Division of Community Development s 615 W. Alder St. Bldg.8 . Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00372 * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Amber Selby on:06/09/2022 02:45 PM Page 6 of 7 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us NEW SINGLE FAMILY RESIDENCE BLD2022-00372 Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B.) Septic tank(s) requires 5ft setback from all footing/foundations. C.) No foundation/ Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. Applicant will need to submit a new satisfactory Operations and Maintenance inspection on septic system prior to final occupancy. " Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with the 2018 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S5.0 designate wall(s)type E & F with fastener spacing 4 inches or less. The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton, WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said project. • All setbacks are measured from the furthest projection of the building. • The destruction or alteration of Fish and Wildlife Habitat Conservation Area's or their buffers through removal, excavation, grading, dumping, discharging or filling of any material; clearing; shading; intentional burning; vegetation removal (terrestrial, freshwater, or marine); planting of non-native vegetation that would alter the character of the FWHCA or buffer; or the construction or placement of structures or increasing the structural footprint shall undergo mitigation sequencing and shall require a habitat management plan. • Application acknowledges that the structure is only permitted for a use consistent with the current zoning of the parcel. " On-site Septic System final installation approval required prior to temporary/final occupancy of the residence. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or no a granting a permit does not presume to give authority to violate or cancel the provisions any o er stat regulating construction or the performance of construction. 'Y Issued B Contractor or Authorized Agent: Date: Printed by:Amber Selby on:06/09/2022 02:45 PM Page 7 of 7 bLD Zd 2,2 - o0 37� �G;�o-4 9/3o 73 'Tat- -726 • If. rn44 f Lk D. S . Web Hole Specifications:Circular Holes UP roa MIT dfaemlar hok If-length a web Mtween edj..thole[ .. mkwee anwnen mlMalaA eMll be at lnm twkedw lagnt dimemlon Cbsasf spacing IT aIN Iwo het ereI�zs•gru�nel�wrio<enb�r. END SUPPONT whkl�- -ti.l 1 INiERIDP DP CANTIIEVEP-END SUPPORT i i N OI 7$ 7 e1 i2v, 8 io cbeM dlalarce blmumxacbakr Mk clrt Hole cAPEwun ;ErrHERSUP4PORTj 00 NOT rWFACI1THOlE31FIlO1E ERHER SUPPON7 DO n'aT CIrt FHtIbT FI.WGF81 TO USE: 1. Selea fhe required serras and depth 2 Determine thesuppoN rnMition for Ne neoren bearing end[up;, winlow support)-luding-anal -eM supports). 3.Salea the row cwrespoM4 I,IN required Clear Span F-pans N-uprose listed.use the N.largest vaWe. 4 Safestthe__corresponding to IN required NW dkmete..For dWmet-between those listed•use IN-Wlgesl too. 5.the int,rsesflon of the Ckar Span sow and Fbk OWmaer edumn ghat the Mnimum distance from IN Into,taco of beadng to lhecpntaola circular No. 8 Double check the dlstarrce to the other supparl,using the appmWiam support conditbn. clear Dtafern ow•Ena s, 13N. afmm mNrm.er coal -Erws DESIGN ASSUMPTIONS: d Serlaa Dapfh spa. -",I,DIerA a H,k .a 1. the hdeWMlom liAN abet aen9tl for floor laiats fro 2• In• v 2• r e• 1r PpoNnBonlyunilorm lusts the Wal wdferm batl allrwl eesced 130 pM leg,40 psl lha lead and l5 � - t'-0 I-0' t-0 py OpM Load spasetll6'oc1. B-1/x' 10' t'-0• I'3' Y-I' - - 2 Hak kcalkn is measuetl frpmtha ksoe f."f 14' 1'-0' T-]• -8• - 1'-It' T-8' S'-r - - - brsrin8m 0w cenleraaaulwhok,lrvm lM ebsmt lPI1B 18 x-1' 4-r T-2' - - 4'-5• 8'-3' B'J• - 3.Cbe3 has na been verilkdlw meet 10' 1•-0• 1'-0' 1'-0' "'(1. - I'-p• 1'-0' 1'3' 3'A• - - end is shoamsoot Boml ltolh anoib 11-7/8' 1-0' 1-1' 4'A' - - 1'-0" T-0' 3'3' S'-0' - - Veay IN,IM1eloistsN.I.oilswrk fro Ne[pen eM tr 1'-0' 2W V4V 6'-H• - - Y.9' 4'A• 83' r-t" - - boding condabmr dN before[ Id,g If a' x'3' ,.V T-0' B'A' 6'3' 7-0' B'-9' tt'-0' Iwk bc,aon. T ''-r 1'-0' 1'-0` - - - 1'4• 1, - - 4.Th.madman hole depth to sucukr Nits W Oe l{eisI tr 1'-0' 1'-0• 1'-0' - - - 1'-0' 1'-0' ra. NpN less P,euapt 0w mvi..hole 9-1/2' ' d*h is B'for 311TIp1jobm.ard 8'Iw 11-7/8'M N' 1'-0' t'-9• 3'-r T-T T-11' W, - 5,is n.-be bamdinths[panwfiere ou,",md 10' 1'-0' 1-0' f-0' 1'-0' - - 1'-0• V.,) wsfssavemlysb bye t'-0' Y-1' 3'4' _ design gaessimel 1 /B' 18' 1'0• 1'-0' '-8' 4'-1' - - 1'-10' 3'- VIIWka 3 4-r 6'-11' - - ` a 1.3'_ 3,2 4 B T I-1' DTES: !� 9 'C- 1 P .p•^ .0 R' 1 0' 1'.0 1 5 1'-7' 3'-g'. 2'-10 J I-'g'-1' ¢13• 1, smaY ba plecM aihwhmewtfM lM1e deem of 14' tlmwab AmWtlmum l/4'deardlslon-flu g. I^g gg 21' 1, 2'-9 l'-I' S'-r Y-0' - 4'-2" - 6-5' r-T V-g" - Ihrge[Is mcommBiMadao as namc��a fknge. `�IW 28' 3'A' S'A' '-' 8'-0' 9'3' - 6'-8' T-10' 8'-tI• 10'-1' 11'N• - 2 flwmd hales upm}I/YdiemeM mry I.PWoed 18' 1'-0' 1'1' 1- T-5• 3'-r 4'-11' 1'-0' Y-8' 3'-r 4'A' 1'11 w.s. g W-1,IF aYaNs•maY be regkmed when N, 2Y I-' T-5' 3'A• 4'4• 8'-1' TA' 4'-0' 6'-0• 8'-0' T-0' 8'-r 9'-0' orating d'k- s, 28' 3'A' 41 5'-11' 1-3' W1 10'-t" T-¢' T-8' 8'-0• 8'-8' 4.Noks Wiger Nan}I/T'am mt Dcrmi0�ln 3P 8'-T r-0' 8•-0• 8-8• Ir.,r 1Y-10' P-0• 10'-0' H'-0' U'-0' 19'-1" f1'-e" rantiksers waM1out specWl englmedrg IO' 1'-0• 1'-0• 1'-0' 1'-0' - T-0' 1'-0' t'-0' 1'3' - 6.Nuhipk M1oles slat h-aclear sepamtim along 14' 1'-0• 1'-0' 1'-0' 2'3' - - 1'-0' 1'-0" r3' 9'-8' IN ItA&of Ne jast a et k1f,oum IN huger 11-7/r - - d'rmnuonalhe Wrgw edjesenl Ink,ore mWmum 1B' 1'-0• 1'-0• R'-0' 4•-r - - 1'.' 2'9• 4" ,'3' alY uaw-teCenkl,wfiieM,ris F-11' V-V T-r T-8' 1'-r 8'A" 8'-8' 8.Nu8lpk hdm mry be spaced closet pmNded Ney IV 1'-0' /-0• 1-0• 1-0' 2'10' - 1'-0" 1'-1. 1'-0' 2'-0• 4V" -- 41 within IN bourdalyof an x"Ptablo larger hole. 6 N• T-0' 9'-0' 6'-J' - 1'-0' I'-¢' Y3' T-0' r-10' - E!ampb:two 3'round-e4Yl'ed-IIII1.1s, a' 1'-3- 3-T ". T-10' - T-2' T.11• ¢'-9• TA` SW _ N�sl kngNm N spas,.,To,,(char d'atancel VI¢8 a' 1, 3'-r S-0' T-t0' 10'fi' 41-8• 8'4• r,. IT-0' 12'-r of- gourd de ue�-,utEle to IN R1 depth 18' '-0• 1'-0' 1'-0' T-T 3'-10' fi41- 1•-0• 1'-0• 2'-7' 4'-1' S4' 1'-3' klhal lo[ation ena compklety enWmpassthe M1oks. a' 1'-0' 1'-0' 2.3' 4'-3• fi'3• TA• 1'-11- T-r fi'.1• fi'-r r-2- 9'-tl' 7.Far ou.1hots mtwmed In IN Wbk.use 18' Y-11' 4'3' 8-• lPa deli Mwarawwaxt bcel B B-t0" lr3' 4 fi• T-0' T-r 8'-1' l0A R t0' Bn so your 8-T 11'4i• 11-0' 6'-11' 84. 10", 11'T 1Y6 V SOYd9Wn'Engirrewed Wrud ProtluIts tllmd0aor fwrmelaomwl on LPI42Pma 9-I/x, 1D' 1'-0` f-0' 1-0' - - 3A• t•-0' 1-0• 14' 1'-0' 1'-0' 1'A' - - - 1'•0' 1'-5' 3'-r - - - 18' I'-0' PA' 3'A' 2'-3` 3'-H' P•r 10' 1'.0- I.A. 1'-0. 1., - - I'-D' ff, "4. 11-7/8' a' 1•-r Y-x' tY'•-18 4t'--• 0- W-rr IV 1-0• t'-0 - - tY-0' sT-3r 42'--ri" 5T-A1'• -- - - {•-/• ¢'-9' r-1' 8-¢• V1 s2Pga +2U I'-0' 1'4" t'-0' I'-2' - t'-0' 1'-0' 1'-¢• 2'•r - 8 N' 11'A' -3'-I• 4' 1'-8• T-90' T-11'4'-1' 5.4- 1"'o - 4'-T 5'-4' 8'-5• T-r V.V 5'-0' r-r 8'-0' r-0 63• T'-10' W-1r 10'-r 1,'4- I'-0' ' 2'-,' T-r 1'-fl' I'-8• Y-1• T-r 4'A• S-0' 8'-1. 18' Tf-0s'-0' 8'-0' TA'4'3' ¢'-11' T-T 8'-r r.18•-8' r-8• 114• 9- If, 1T-9•T-0' rI' 214. 1r3' 1T•1r 8'-0• IW4' 11'-0- IT-01 13'4• 14'-8' 14 - _ C ' oxY .Utz ttt 41 f I _ rj 5 it r 6 F Y s NNNNNNNNN23 �{1 s; 11. 1{ t fill,I 10 fill fit i i II -- -- • ,�,� MARKARIAN-CUSTOM IWP33110 �" r MAIN FLOOR JOIST LAYOUT