Loading...
HomeMy WebLinkAboutBLD29038 Final SFR - BLD Permit / Conditions - 12/12/1991 ;Uo�RCtvu4.fD P'Ca���9 yoA�t Shorelines: Mechanica Setback: Interior: Special FINAL -9., 4144 Conditions: Mobile Home: - � Smoke Detector* Aw c Remarks: <f� ooting: setback: ,7z� , kl t� Foundation 0 _ Walls 0/< Framing: - Fireplace: Wood Stove: TYPE ESIDR!CE No. Floors n Ft 1496 Permit No. 29030 �1 g .T Jl�.SGid Tel"i��19 Date Owner MAC i.11a11G�., Zip— Address 314 S Sidne RoLt Orchard Contractor 1 ip Address Legal Description Beards Cove div 3 lot 84 Direction to project site U sandhill left on Anc or c anica ewer Wo Stove im ing arage x _ arport Deck Fireplace Aft Other Basement BUILDING PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES 426 W.CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584 427-9670 DATE ISSUED PERMIT NO. 0?6 OWNER NAME c MAILADDRESS C CITY&STATE ZIP PHONE DIRECTIONS TO JOB SITE 4t5�k( � PARCEL LEGAL NUMBER DESCR. NAME MAIL ADDRESS CITY&STATE ZIP PHONE LICENSE NO. CONTRACTORtlCi�'hm,� USE OF BUILDING es t-jv-�- CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE WORK ✓ DESCRIBE WORK AREA: 19 NUMBER OF: PLEASE INDICATE: NOTICE SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR RESIDENCE SgFt STORIES SHORELINE❑ CONDITIONING. BASEMENT SgFt BEDROOMS c' PRIMARY RES.❑ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT DECKS $ Ft BATHROOMS SEASONAL RES.❑ COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR g ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. CARPORT SgFt FIREPLACE IS CARPORT/GARAGE GARAGE )-C) SgFt ATTACHED XDETACHED❑ OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. c APPROVAL FROM THE BUILDING DEPARTMENT. c, X OWNER DATE o - 1 e y X BY �— DATE FOR OFFICE US ONLY DEPARTMENT YEAPPROVEDJO DEPARTMENT YES DEPARTMENTBUILDING VALUATION HEALTH PUBLIC WORKS )FEE PLANNING FIRE MARSHAL BUILDING PERMIT D.O.T. BUILDING PLAN CHECK SPECIAL CONDITIONS BUILDINGGROUP 1 PRE-INSPECTION SHORELINE WOODSTOVE < PLUMBING , L MECHANICAL STATE BUILDING FEE APPLICATION ACCEPTED BY PUNS CHECK BY APPR ED R ISSUANCE [ ERMIT VALIDATION ,�f,, TOTAL �'(e 50 BY CASH CK MO PLUMBING & MECHANICAL PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES 426 W. CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584 - I .Z - ( ' 427-9670 DATE ISSUED q y� PERMIT NO. C y NAME MAIL ADDRESS CITY&STATE ZIP PHONE OWNER 304 5 S P+, ar ct 1p(- Is 7(0—b kil DIRECTIONS TO JOB SITE (,( (•) ( (q:F+ 21 c.`I� (V� bl. LEGAL D SCR. rJZNAME ( c� CONTRACTOR "L`�1 NON MAIL ADURNS CITY 8 STA EJ ,LICENSE NO. c2� ZIP PHONE/ c Nvi w �TL USE DI ,n� tT �z*K4 BUILDING �'QSj1��^"� l�r/L�`"`'�-7ff- PLUMBING FIXTURES MECHANICAL FIXTURES NO. 2.00 PER FIXTURE OR TRAP FEE_ NO. TYPE_OF FIXTURE FEE WATER CLOSETS FORCED-AIR I GRAVITY TYPE FURNACE 6.00 BASINS FLOOR/SUSPENDED FURNACE 6.00 BATH TUBS Ll BOILER/COMPRESSOR 6.00 SHOWERS REPAIR I ALTERATION 6.00 WATER HEATERS REFRIGERATION COMPRESSOR SYSTEM 6.00 AUTO.WASHER AIR HANDLING UNITS 7.50 SINKS HEAT-PUMPS 6.00 FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT LAUNDRY TRAYS FIRE SUPPRESSION 5.00 CONNECT TO CITY SEWER WOOD FURNACE 5.00 DISHWASHER DISPOSAL URINALS PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00 TOTAL -� TOTAL SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND 1 AM AWARE OF THE ORDINANCE COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVALFROM THE BUILDING DEPARTMENT. X OWNER V4, DATE I� ' X BY P-`o`t�— DATE FOR OFFICE USE ONLY APPLICATION ACCEPTED BY PLA HE K V BUILDING GROUP APPROV FO�j S C IPERMITVALIDATION �3 ry'. 1 BY 'v '� CASH CK MO BUILDING PERMIT PLOT PLAN MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. Box 186 SHELTON, WASHINGTON 98584 477-cr-7n PERMIT VO. N:.h1E , :•il-A00 E>; C17f4 STArc LIP PH NE. O W N E i 3l �'{ lv 7 N 5 O 1a a S I Svc I PRncc, NUMBED I O E S C; I &,Irv!S Indic_;e te!ew: r' Prcpe-" lir: ,nd dieters'^5. CDEasements and roads. O Septic, drainfield and reserve area, or sewer. 0 O Septic tank and drainfield setback distances fron foundations. O Location of proposed construction on property. O Building g septic system setback distances from all property lines & easements. Indicate North O Well and water line. O Saltwater, lakes, rivers, streams, wetlands, drainage. In Circle O Arach copy of septic system"as built' or septic permit-approval. O Indicate topography profile of property and structure on reverse side. -1 4� I LIE I I I I I I I I I IIII I I I I I I I I I I I ( I I I ( I I I I I I I I I II i t I I I I I I I II I I I it s l ( I I I I I I III I I I I I I I I I I I I I I I I i �51'Ui I I I I I I ( I I I I I I I I I I I I I I I I I I I I I II ( I I I I I I I I I I I I I I I I I I I I I III I I I I I ! I I I I I I I I I I I I I I I I ! uwt .r� ..1: Ji? "i: __ _"+ ... - - - ..^i irC :225 S'_ 1C.. 1:_.`.]!'J_`3:�'_S •�'._ 1__ .r.;. .._..'if S. Jb;1�.a.:y^ i� •3 WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/13/91 FILE: B:SGC1210.WS HOUSE ID: SGC1210 =-------------------------------------------------------------------------------- --------------------------------------------------------------------------------- Site: DIV 3 LOT 84 BEARDS COVE Analyst: BELLY BUECHEL BELFAIR, WA Jurisdiction: MASON COUNTY Utility: MASON COUNTY PUD #3 Homeowner: JASON MACKINNON Mail : Floor Area: 868 ft2 Builder: Weather Data: Olympia, WA Address : Climate Zone: 1 ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 1.66 165 Btu/hr-F ; ENERGY BUDGET 2 . 23 2 . 19 kWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Floor U-0.029 868 25 .2 Glazing @15% U-0. 400 130 . 2 52. 1 Doors U-0 . 200 40 . 0 8 .0 AG Wall U-0.058 932 54 .0 Ceiling U-0 . 031 868 26.9 Infiltration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Reference UA 166 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Floor R30 vented Joist 16oc �l0 0 U-0.029 806 23 . 4 **STAIRS/LANDING R19 d.Av U-0.041 62 2 .5 Glazing @15% **4ff436*RD VINYL XO W/AR 11-0 370 93 .0 34 .4 *t�ARD VINYL PATIO W/AR� v U-0.4 8 0 35 . 0 16 . 8 Doors Metal 1.-3/4" urethane flush - U-0 . 140 21 .0 2 . 9 Wood 1 -3/8" solid flush U-0 . 390 19 .0 7 .4 AG Wall R21 INT T1 - 11 U-0. 056 900 50.4 R11 STD T1 -11 U-0.094 34 3 .2 Ceiling R49 blown Attic STD baffled U-0.027 868 23 . 4 Infiltration Standard Air Sealing ACH-0. 350 6944ft3 ( 44 .5) - - - - - - - - - - - - - - - - - - - - - - - - - - - - Proposed UA 165 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/13/91 FILE: B:SGC1210 .WS HOUSE ID: SGC1210 Struc Mass Light Frame, Sheetrock walls M-3 . 000 868 2604 .0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Electric: Zoned Make : Model : System Efficiency: 100 % Modified Efficiency: 100 % Heating Load(at 53F dt) : 12760 Btu/hr System Size: 3 . 7 kW Maximum Size @150% : 5 . 6 kW Average Annual Heat: 2751 kwh Annual Cost: $ 151 Ventilation Type: Non-Heat Recovery Option: Option 1 Cooling Load(at 5F dt) : 13641 Btu/hr Recommended Size @125% : 1 . 6 tons Solar Access: Partially Shaded - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - GLAZING ORIENTATION PROPOSED PROPOSED South: 32 .0 ft2 North: 32 .0 ft2 Southeast: 0.0 Northwest: 0.0 East: 32 . 0 West: 32 . 0 Northeast: 0 . 0 Southwest: 0 . 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. -------- Page 2