HomeMy WebLinkAboutBLD29039 Final SFR - BLD Permit / Conditions - 4/20/1992 Shorelines: P I unb i ng:,/)k
Setback: Mechanica :
Special Interior:n 7 ,i
Conditions: FINAL:�iy-2c?-9-- s.v�,u
Mobile Home:
Smoke Detector: - /-o.1 .�t
Remarks:
ooting:i � -/ �i' mot �►1 wa�� ��
Setback:OX Wr 3 ,lYs
Foundation
Walls:
Fireplace:
Wood Stove:
TYPE RESIDENCE
Permit No.29O39 No. Floors 2 Sq Ftg �724
Owner Jason MacKinnon Tel 876-661° Date 9 12 91
Address 314 S Sidney Port Orchard 98366 Zip
Contractor Same
Address 1p
Legal Description Beards Cove Div 3 Lot 86
Direction to project site Up Sandhill left on AWher,
lot is on left.
Plumbing x M-e-CTFa-nical x Sewer Wood Stove
Fireplace Deck x Tar—age x arport
Basement Loft Other
PU003
BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
426 W. CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584
427-9670 DATE ISSUED _ I -ell
PERMIT NO.
Ow NAME MAIL ADDRESS CITY&STATE ZIP PHONE
OWN u., c ` 31 S pt cc--'-'d kc,
DIRECTIONS
TO JOB SITE LAP Sn"'cat'ju �
PARCEL LEGAL
NUMBER DESCR. ��±c�tY�� `%� 16" L4 �4a
NAME MAIL ADDRESS CITY&STATE ZIP PHONE LICENSE NO.
CONTRACTOR ���
USE OF
BUILDING
CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE
WORK ✓
DESCRIBE
WORK
AREA: } Y NUMBER OF: PLEASE INDICATE: NOTICE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
RESIDENCESgFt STORIES�_ SHORELINE❑ CONDITIONING.
BASEMENT SgFt BEDROOMS PRIMARY RES.❑ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
DECKS $ Ft BATHROOMS COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
q SEASONAL RES.❑ ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED
CARPORT SgFt FIREPLACE IS CARPORT/GARAGE
GARAGE SgFt ATTACHED J DETACHEDX
OWNERSAFFIDAVIT CONTRACTORS AFFIDAVIT
1 CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING
OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. + APPROVAL FROM THE BUILDING DEPARTMENT.
XOWNER DATE _ S—,3"ell XBY ' �` � DATE
APPROVED FOR OFFICE USE PRONLY J
DEPARTMENT YES NQ DEPARTMENT YES No BUILDING VALUATION
HEALTH ' PUBLIC WORKS gv FEE
PLANNING FIRE MARSHAL BUILDING PERMIT
D.O.T. BUILDING —ffn PLAN CHECK
SPECIAL CONDITIONS BUILDING GROUP PRE-INSPECTION
SHORELINE
WOODSTOVE
PLUMBING
MECHANICAL
STATE BUILDING FEE
APPLICATION ACCEPTED BY PLANS CHECK BYC) APPR ED R ISS A CE PERMIT VALIDATION
BY ASH CK MO TOTAL
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
426 W.CEDAR/P.O. BOX 186 SHELTON,WASHINGTON 98584 Q
427-9670 DATE ISSUED 1�'
PERMIT NO.
NAME MAIL ADDRESS CITY&STATE ZIP PHONE
OWNER �'vwuo-. ar&-,fo/ cam 4''YT Ii�6 76- 66\
DIRECTIONS rl
TO JOB SITE U "-I (1 (+Q C �+- �'� o t. .2�'�"T'
LEGAL
DESCR. Vc. ,rdS C_o or- Lz4- '15 1;-
NAME MAIL ADDRESS CITY D&STATE LICENSE NO. ZIP PHONE
CONTRACTORPQ,��,.�n l�N c4t,cw. S'76--bb
USE OF
BUILDING
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
WATER CLOSETS FORCED-AIR/GRAVITY TYPE FURNACE 6.00
BASINS FLOOR/SUSPENDED FURNACE 6.00
BATH TUBS BOILER/COMPRESSOR 6.00
SHOWERS REPAIR/ALTERATION 6.00
WATER HEATERS REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER AIR HANDLING UNITS 7.50
SINKS HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT
LAUNDRY TRAYS FIRE SUPPRESSION 5.00
CONNECT TO CITY SEWER WOOD FURNACE 5.00
DISHWASHER �rQt
DISPOSAL
URINALS
PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00
TOTAL TOTAL
SPECIAL CONDITIONS: NOTICE. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE Y-13'�� X BY ` DATE
FOR OFFICE USE ONLY
APPLICATION ACCEPTED BY P S CHF�i BUILDINGG GROUP J AP VE R ISS CE PERMIT VALIDATION
55 1 BY CASH CK MO
WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/13/91
FILE: B:SGC1211 .WS HOUSE ID: SGC1211
Site: DIV 3 LOT 86 BEARDS COVE Analyst: BELLY BUECHEL
BELFAIR, WA Jurisdiction: MASON COUNTY
Utility: MASON COUNTY PUD #3
Homeowner: JASON MACKINNON
Mail : Floor Area: 868 ft2
Builder: Weather Data : Olympia, WA
Address : Climate Zone: 1
The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. ;
REFERENCE PROPOSED ;
COMPONENT PERFORMANCE 166 165 Btu/hr-F ;
ENERGY BUDGET 2 . 23 2 . 19 kWh/ft2-yr
REFERENCE DESIGN
Reference
Component Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Floor U-0 .029 868 25.2
Glazing @15% U-0 . 400 130 .2 52. 1
Doors U-0 . 200 40 .0 8.0
AG Wall U-0.058 932 54 .0
Ceiling U-0.031 868 26 .9
Infiltration - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Reference UA 166
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PROPOSED DESIGN COMPONENTS
Component Description Value X Area = UA
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Floor R30 vented Joist 16oc U-0.029 806 23 .4
**STAIRS/LANDING R19 U-0.041 62 2 . 5
Glazing @15$ **M14,9RD VINYL XO W/AR U-OZO 93 .0 34 .4
**MIW A- VINYL PATIO W/AR U-0.480 35 . 0 16 .8
Doors Metal 1 -3/4" urethane flush U/y, U-0. 140 21 .0 2 .9
Wood 1 -3/8" solid flush �J U-0. 390 19 .0 7 .4
AG Wall R21 INT T1 - 11 U-0.056 900 50.4
R11 STD T1 - 11 U-0 .094 34 3 . 2
Ceiling R49 blown Attic STD baffled U-0 .027 868 23 .4
Infiltration Standard Air Sealing ACH-0.350 6944ft3 ( 44 .5)
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
Proposed UA 165
Items in parentheses not included in COMPONENT PERFORMANCE totals .
** Denotes non-standard values - check calculation of thermal value .
Page 1
WATTSUN 5 . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 08/13/91
FILE: B:SGC1211 .WS HOUSE ID: SGC1211
Struc Mass Light Frame, Sheetrock walls M-3 . 000 868 2604 . 0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HEATING/COOLING/VENTILATING SYSTEMS
PROPOSED
Heating System Type: Electric: Zoned
Make:
Model :
System Efficiency: 100 %
Modified Efficiency: 100 %
Heating Load(at 53F dt) : 12760 Btu/hr
System Size: 3 . 7 kW
Maximum Size @150%: 5. 6 kW
Average Annual Heat: 2751 kwh
Annual Cost: $ 151
Ventilation Type: Non-Heat Recovery
Option: Option 1
Cooling Load(at 5F dt) : 13641 Btu/hr
Recommended Size @125% : 1 .6 tons
Solar Access: Partially Shaded
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
GLAZING ORIENTATION
PROPOSED PROPOSED
South: 32 .0 ft2 North: 32 . 0 ft2
Southeast: 0. 0 Northwest: 0. 0
East: 32 .0 West: 32 .0
Northeast: 0 .0 Southwest: 0 . 0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
------------------------
Economic and energy consumption estimates are designed for comparative
purposes only. Actual cost for heating will vary depending on weather
conditions, occupant lifestyle and other factors .
Page 2