HomeMy WebLinkAboutBLD2002-00964 Final MFG Home - BLD Permit / Conditions - 7/2/2003 Insction Line
262
f MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Poe: (360)427(96700,ext7352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 �^2 „<:5>3
IP4 Shelton,WA 98584 � /9
RESIDENTIAL BUILDING PERMIT BLD2002-00964
OWNER: JEFF CLANCY 360-479-2603
CONTRACTOR: GORDON BOYER CONSTRUCTION LICENSE:GORDOBC099JE EXP:4/2/2004 RECEIVED: 7/23/2002
SITE ADDRESS: 1400 NE MISSION CREEK RD BELFAIR ISSUED: 9/9/2002
PARCEL NUMBER: 123303390100 EXPIRES: 3/9/2003
LEGAL DESCRIPTION: TR 10 OF GOVT LOT 4 TR 3 OF SP#914 PCL 2 OF BLA#95-70#612648
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
MANUFACTURED HOME TAKE NORTHSHORE TO R MISSION CREEK GO 1.2 MILES ON THE R SIDE
OF ROAD
General Information Construction &Occupancy Information Square Footage Information
No.of Bedrooms: 3 Type of Constr.: V-N
Type of Use: MH Insp.Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck:
Type of Work: NEW Fire Dist.: 2 No.of Stories: 1 Occ. Load: Building:
Valuation: Building Height: 13 Occ. Status: Primary Basement:
1 Manufactured Home Information Setback Information
Shoreline&Planning Information
Make:SILVERCRE Length: 66 Ft. Front: S 60.0 Ft. Shoreline: Ft. Water Body:
Rear: N 100.0 Ft. Slope: Ft. SEPA?: Unkn
Model:LT-68 Width: 28 Ft. pp'Shoreline Desig.: bWOA II� Side 1: E 40.0 Ft. cable
I
Year:2003 Serial No.: Side 2: W 180.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Mobile Home Submittal Fee KLW 7/23/2002 $194.50 59983
Address Fee GMM 7/23/2002 $15.00 60494
Planning Site Inspection RAM 8/8/2002 $70.00 60494
Building State Fee RLS 8/20/2002 $4.50 60494
Mobile Home Issuance Fee RLS 8/20/2002 $194.50 60494
EH Plan Review CEW 9/5/2002 $75.00 60494
Total $553.50
BLD2002-00964 Please referto the following pages for conditions of this permit. 1 of 4
t CASE NOTES FOR
BLD2002-00964
CONDITIONS FOR
BLD2002-00964
1) This application is subject to Buffer and Landscaping requirements as established under Mason County Ordinance
1.03.036.X
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
X800-647-0982. The pperson signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
3) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of
the Mason County Fire Marshal. X —jy
4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X
5) Regulations which apply for GRADING of the slope (per Mason County Resource Lands and Critical Areas Resource Ordinance):
A. No grading shall be performed on the slope prior to obtaining approval by the Planning Division and based on recommendations contained in the
geotechnical report with slope stability analysis and grading recommendations.
B. Clearing, grading, and other construction activities shall not aggravate or result in slope instability or surface sloughing.
C. Undergrowth shall be retained.
D. Clearing methods which minimize soil disturbance shall be used.
E. No fill, dead vegetation (slash/stumps), or other foreign material shall be placed within the slope.
X ��
BLD2002-00964 Please refer to the following pages for conditions of this permit. 2 of 4
6) The Mason County Resource Lands and Critical Areas Ordinance requires vegetative management of the site. There shall be a minimum disturbance of
trees and vegetation in order to minimize erosion and stabilize the slope. Limbing tree for view purposes is preferred over tree removal. Any grading or
vegetation removal on the slope will require a geological assessment. X
7) All construction and demolition debris must be removed from the beach after project completion. Proper disposal of construction debris must be on land
in such a manner that debris cannot enter or cause water quality degredation of State waters. X _S77c__�_
8) Approved per dimensions and setbacks on submitted site plan. X
9) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X_ ('/
10) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and
legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site
inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or
contractor fail to post the address on site prior to requesting inspections.
X �
11) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X y C-_�
12) The"approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" plot plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
X 2
13) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County
and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would
result in permit revocation.
X
14) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all
responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the
inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the 1997 UBC, and will be assessed in
addition to my original permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this
investigation will be scheduled as time allows. Until resolution of any/all p oblems no occupancy(Final Inspection)will be granted for the residence.
OWNER/CONTRACTOR(indicate which)Signature XIC
i
15) This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indidcated on
the plot plan. X Sri
16) All mobile/manufactured home landings or decks must be freestanding (self supporting). The largest landing or deck allowed without drawings or a
building permit MUST be under 30" in height from surrounding grade. NO second story decks, or decks above 30"can be built without a permit. Any
landing or deck that is 30"or more in height from walking surface to finish grade requires a Permit. Any landing or deck that has 4 or more risers requires
a handrail. X
BLD2002-00964 Please referto the following pages for conditions of this permit. 3 of 4
17) All changes to "approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance
or regulation, myaL4e reviewed and approved by Mason County prior to construction.
X
18) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector. _�e made prior to requesting additional inspections.
X "_-
19) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including
installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be
clearly marked in the installation instructions.
20) All property lines shall be clearly identified at the time of foundation inspection. X
21) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
X Mason Couunty ordinances and building regulations.
r
22) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder h ven d action from being taken. No more than one extension may be granted.
X
This permit becomes null and void if work or constructi n authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of contin ation of wor 's a r gress inspection within the 180 day period. Fi I inspection must be approved before building can be occupied.
OWNER OR AGENT: DATE: Z_
BLD2002-00964 Please refer to the following pages for conditions of this permit. 4 of 4
I i
o CONCRETE MECHANICAL MANUFACTURED HOME-
0
^� Footings / Setbacks Date By Ribbons
0
Date By Gas Piping Date /o`t - _Da, By I6C�
Foundation Walls Date B y Set-up
Date By INSULATION Date 251-43 By r--
B G / Slab Insulation Floors Final
Date By Date By Date By
FRAMING Walls FIRE DEPT
Date By Date By Date 7 Z -CZ By
PLUMBING Attic OTHER
Groundwork Date By
Date By WALLBOARD NAILING
D.W.V. Date By
Date By FINAL INSPECTION
Water Line Date By
Date By Date By
CD
o
0
v
8
0
o l 1
y r
r
0
0CD
N
N Vr"'C
i
O
O
`O
0
l
N
O
243.65 PLA �L.O E ISION
DATE
Jeff Clancy
1300 N.E, Mission Creek Road
Be 2330 33 98528 0 REVISED
10 of Gov Lot 4-
Lot 5 L1ATE
Scale: 1" T 4p'
CO
03 Legend
Re s e ve: R - -- ------- ---- — - - - -- --- ---- ----- --------- --
Drainfi Id
r hate als -------
Cb Qti
rb J
OC9
30.00 Dri"eW 3 Bed rn ra
ti
S Feo-
1 1 esidf-� e
I 1 I
w
o I I I I I I I I
101 1 1 1 1 1 1 1 I
w
I I I I I I I I I I
140.00
1
opt.
r
FAMILY ROOM lD
OPT. � WT. I
BEDR00w-4
OPT. OPTIONAL WINDOWS QDD" n7
BEOROGM-5 m
OPT. m
MASTER N
BATH
N
m
-------, DF N
I �
I
Q
---- I _ 11'-q
13'—4. 7'_9'• 8'—]0" 3
r-
I o naxxa tarrtir m
3E I oM ncc sp us . 70
Id!
o
Ie: / U 71LITY Dpt m
M FAMILY ROOM OININC KITCHEN
r
l
L_,.f1_s J, M ASTER D
BATH 70
i O
A PAN TI[1' MCLOSET w
� 91ot
OPT
19
1
t � 1
i I Gl7CSf ::1
C
-------
v �
7-
1
e� BEDROOM-3 O 8EOROOM-2
BATH LIVING MASTER W
2 ROOM BEDROOM m
i
Ul
Q�
m
N
�12'-1" 5'-3" 22 0" 16'—Q.,
CD
12113101 LT"" 68 1782 SQ. FT.
1
PERMIT NO. BLD2LCJ.0b
MASON COUNTY
BUILDING PERMIT APPLICATION
426 W.Cedar/P.O.Box 186,Shelton,WA 98584
Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968
APPLICANT I R TION CDOa CONTRACTOR INFORMATION
Owner krmltw Contractor Name
MailiogAddres Mailing Address
City f ^State 11 ip Code City rj State ►,dA Zip Code
PhoneL3W) Other Ph.(3� 0 (pt'X) Ph. I-) - C ther Ph.( 31yC ) yDh '7
Lien/Title Holder
�T``` Contractor Reg. #
Address Expiration_ ,�—/nQ/ D4"7
SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing Septic Connect to Sewer
System Name of Sewer System Well Water System Name of
Water System
PARCEL INFORMATION-12 digit Tax Parcel No. Tc � —/ _/ Fire DistrictY
Legal Description a
Site Address(Please include street name, s et number and city) -
Directions to site-Ala OtAiMmkovi r
i
Will timber be cut and sold in parcel preparation? (Yes/No)
Is your property within 200' the following: Body of Wat (Name) Saltwater
Lake River/Creek Pond Wetland Seasonal Runoff Stream lopes or {
Bluffs Nba Ir--
PERMANENT RESIDENC SEASONAL RESIDENCE❑
TYPE OF JOB New Add rA�t Repair Other Use of Building
Describe Work 1-4- 1-# '
No. of Bedrooms No. of Bathrooms SQUARE FOOTAGE-1st Floor 2nd Floor
3rd Floor Loft Basement Deck Other sq. ft.
Garage Attached Detached Carpotlt Attached Detached
MOBILE HOME INFORMATION-Make _Model Model Year
Length Width _Serial No. No. of Bedrooms.3No. of Bathrooms
Type of eat t.tkrit, Purchase Price $ Replacement Unit ? es o
Installer Name 10L Certification No.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a
Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work
conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without
approval first obtaining approval
�4, �Y
I X Date ��; L, �( ,' t�' :�, 't Date
FOR OFFICIAL USE BEYOND THIS POINT
Accepted b Date Submittal Amount Due Receipt No.
i
P Y P
_ I
DEPARTMENTAL'REVIEW AP ROVE DENIED CONDITION CODE$
Building De t
Occ Grou e Constr.
Planning Department U to
Environmental Health Department
(6' AWL j
Public Works Department 426 Wa CEDAR ST!
Fire Marshal
i
i
Valuation $ i
FEES {
Building Permit Fee ! 9�� Site Inspection {
Plan Review Fee EH Review Fee {
Plumbing&Base Fee Planning Review Fee
Mechanical& Base Fee Other
Wood/Gas/Pellet Stove Fee State Fee SU {
Violation Fee \0 r Pre-Paid at Submittal ( )
TOTAL FEES
r
11/07-wwo�;e:04 FAX 360 427 7�798
MASON CO PERMIT C,TR fdool
! Request To Revise An A.ppioved Plan
Pelinit Number: BLD200 - Name ZZ
Parcel N' ber a3 D /3_/ololoo Phone Number z��
Project ddres _ �ss�n Mailing Ad' ess
Rao
Please pr ide ac�.omplete, detailed o
description of Proposed
P p p revisions to the approved plans:
i
Are the e building plans, approved by Mason County,
included this application?
Yes D No
Are two sets of the revised plans or addendum indicating the changes included? Yes D No
Are the"sions clearly and accurately identified on the plans or addendum? Yes D No
Does the plan contain an engineer's or architect's lateral or vertical"analysis? LJ Yes °
If es,Has the engineer or architect approved this revision? D Yes D No
Is Ia stamped and signed approval included with this request? L1 Yes Cl No
(Note:No st�Caval C"Iges w an plan-ill be epinoved witbuiu the wjitrao consent of the ragi =or orchittct of rtcurd.)
Does the pJroposed revision modify the footprint or location of the structure? es ❑ No
If Yes, Is a revised site plan, drawn to scale, included with this request? Yes ❑ No
Additional1 Information.- j
i
AkForwaird ,n
Date:
&,csiv*d by. tom;
ts wdicaoed below: Dare Original valuation:
Addiflrnral Valuauiom:Sq Fli x
Sq Ft x
Hcal[h �t i foul New Valuation.
0 Publi�Works Addili).nal Faeis:
AdditionA Plan Review
Addido"Conditlom t COMMCUU; Additional$ur7diag Pcnmit
Additional Plumbing
Additional 1Vl hanical _
othrr
— Total Amour t Due: