Loading...
HomeMy WebLinkAboutBLD2006-00338 Final SFR - BLD Permit / Conditions - 11/14/2006 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 L� RESIDENTIAL BUILDING PERMIT BLD2006-00338 OWNER: KIMBERLY CRITES RECEIVED: 3/9/2006 CONTRACTOR: REALITY HOMES INC. 253-926-6330 LICENSE: REALIH1984CN EXP:2/1 512 00 8 ISSUED: 5/3/2006 SITE ADDRESS: 144 NE SEITZ DR BELFAIR EXPIRES: 11/3/2006 PARCEL NUMBER: 123303390022 LEGAL DESCRIPTION: TR 13 GOUT LOT 4 TR 1 SP#2280 PROJECT DESCRIPTION: DIRECTIONS TO SITE: CONSTRUCT NEW SFR. NORTH SHORE TO MISSION CREEK TO LEFT SEITZ DRIVE TO TOP HILL 90%TURN UP HILL TO TOP General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: 4Type of Constr.: V-B Type of Use: SF Insp.Area: No.of Bathrooms: 3 Occ. Group: R-3 U-1 Lot Size: Deck: 150 Type of Work: NEW Fire Dist.: No.of Stories: 2 Occ. Load: Building:2,332 Garage-Attached 484 Valuation: Building Height: 25 Occ.Status: Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: W 113.0 Ft. Shoreline: Ft. Water Body: Rear: E 20.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft.. Side 1: N 63.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 26.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee CMH 3/9/2006 $900.74 B12006000 Hosebibs 2 Furnace<100K 1 Planning Review Fee CMH 3/9/2006 $155.00 612006000 Kitchen Sink 2 Ventilation Fan 4 Address Fee GMM 3/14/2006 $140.00 S22006000 Lavatories 3 Dryer Vent 1 ADJUST--Plan Check Fee RTB 3/28/2006 $3.64 S22006000 Water Closets (Toilets) 3 Building State Fee RTB 3/28/2006 $4.50 S22006000 Water Heaters 1 Building Permit Fee RTB 3/28/2006 $1,391.35 522006000 Bath Tubs 2 Mechanical Fee, RTB 3/28/2006 $61.70 522006000 Clothes Washer 1 Mechanical Base Fee RTB 3/28/2006 $23.50 §22006000 Plumbing Fee RTB 3/28/2006 $96.00 S22006000 Plumbing Base Fee RTB 3/28/2006 $20.00 S22006000 EH Plan Review TW 3/30/2006 $75.00 S22006000 Total $2,871.43 BLD2006-00338 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2006-00338 I CONDITIONS FOR BLD2006-00338 1) Water quality is n b egrad d to the detriment of the aquatic environment as a result of this project. X i 2) Prior to final approval, all upland areas disturbed or newly created y onstrue ion activities shall be seeded,vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 3) Approved per di sions nd setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior an her in pections being performed or approvals granted. X 5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads,"all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and he international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 6) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approve do ment ill result in failure of required building inspections. X 7) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58, Doors (Type/Max - ctor):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38,Vault Insulation R-30, Slab Insulation R-10. X t i I BLD2006-00338 Please referto the following pages for conditions of this permit. 2 of 4 8) Concrete used for b sement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical con cret wor xposed t the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). ` X 9) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents re remove , approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall a Ile t e Building Department prior to any further inspections being performed or approvals granted. X 10) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 11) All changes to "approved" 4uilding plan that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulatio m s e d and approved by Mason County prior to construction. X 12) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be mid pr r to re jesting additional inspections. X 13) All property lines shall be clearly identified at the time of foundation inspection. X 14) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County or!!2=d' g regulations. X �,� \,�_J - 15) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period t exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have pre en ct'o f m being taken. No more than one extension may be granted. X 16) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, an fla ing. I tall metal connectors approved for contact with the new types of pressure treated material. X BLD2006-00338 Please refer to the following pages for conditions of this permit. 3 of 4 This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evid pnce of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspe 'on.The owner or the agent on the owners behalf,represents that the' formatio provided is accurate and grants employees of Mason County access to the above described property an ture for review and inspection Z� OWNERORAGENT: t DATE: ✓ O� BLD2006-00338 Please referto the following pages for conditions of this permit. 4 of 4 n N { CONCRETE MECHANICAL MANUFACTURED HOME o _ DateCD rn .Footings I Setbacks Gas Piping By Ribbons _ Ill o Interior Date By Interior-Date By page By W Exterior Date = By T/�, Exterior-Date B �a-�Cam' / Sat-up Point Load J Isolated Fooangs INSULATION Date By W Date By Data SLAB lrsuLAlloN By FIRE DEPARTMENT X Foundation Walls Floors Date By < Date By Data By DECKS FRAMMwLvt, Waits Date By D I �f LS Data /f-L-e-'F' By PROPANE TANKS PLUMBING VauFt Date By Date By OTHER Groundwork Attic Date B y Type_ L ate• By Dane By D.W IV -- DRYWALL _ TyV: Int Brace Wall Date By W Date id 2P 6)& By Date By FINAL INSPECTION � Water Lin Fin Separation N pate >C) .� By Date (�. .L;.C BV77 Data -j-� 1-07 By/7>j�(( O m � Pass Or Request Inspect. o 0 Type of Insp. Fall Date Date Done By Comments CD 6 sTjn.os �'- See- o � 1 lZoloj; -7- PI VMS 4 /`JIA Faw, v 14/'fCC CD-. � / - e­-,c Tom-2 l 2 GTS , i4/' r 0 Mar 13 2006 11 : 22RM Butch 's Bulldozing Inc. 360-275-7479 p. (?A Ro E \ NED . MAR 13 200 MASON Z 3 3d 3-3 2--Z I -z ` 644C APPROVE V NASON COUNTY DCD PLA � g1TE LAN RCQIJIR,ED TO BE ON S --------p �} CAI GES S' ' ��C,T TO APPROV:: Dale lag i tf t —41 o ) , m Mason County Permit Assistance Center RECEIVED Planning Intake Checklist MAR 0 9 2A Owners Na e: �� Date: — i Project: Reviewed By: i '' —ICE Commercia Development: _ES O� . — i Comments: k Planner: GBM TSC M KJM SNG BJR Site .Plan: , North Arrow qProperty Dimensions: •� t X ( �� < w"Streets and Driveways Shown. Road name: ❑ ".mil-mating Structures shown with setbacks ❑ V0644-eeation, Septic and Drain-field Shown with setbacks I ❑ TA—+n 7 surface water(streams,ponds, shoreline, wetlands, etc.) Topography(slopes) Pro osed Structure Seta¢� p Setbacks (Direc ion/�e�ack): ,F: _/ �R: � 51: / �52: _/ .Z o V.-,Utility t�/U y and Drainage Easements• Y'-s No (if yes enter condition #5022) p-Other Easements Q"- qi enances 1 ❑ y-z4eeess Permit-Needed(add condition#0010) ( �- ❑ State Access Permit Needed(add condition#0020) Standard Conditions to be added to all Building permits that planning reviews: #5019 and#0700 Are there any impedimentthat mpy restrict access to your site? (dogs/gates) Shoreline and Planning Info Setbacks: Shoreline: �Slope: Shoreline Designation: Comprehensive Plan: Rural Zoning: Not Applicable ❑ Agricultural j RR 2.5 5 10 20 ❑ Urban ❑ In-holding ❑ RMF ❑ Rural ❑ LTCFL ❑ RC 1 2 3 ❑ Conservancy ,0 Rural ❑ RI ❑ Natural ❑ RAC ❑ RNR ❑ Unknown ❑ RCC-Hamlet ❑ RT ❑ Urban Growth Area ❑ MPR ❑ Unknown ❑ Unknown Water Body (type of water if unnamed): SEPA: Yes N& Unknown Flood Plain: YES NO nkno Map# Aquifer Recharge: YES NO nkno Map# Tags/Cases: RLC/SPI Case: 6-Year Dev. Moratorium: YES NO Eagle Nest Tag: YES NO Other YES NO Addressing: Check box if needed ❑ Reviewed by: Revised:07-12-2005 [:\PLANNING\CHARELL.&RENEE\PLANNING INTAKE ACCESS & GRADE WORKSHEET DATE: ADDRESS �� `� L - - INSPECTOR DRIVEWAY ACCESS Length: )W + Width: ('L Surface: /0,0-e 41qcp Size of turn-around: C/ Condition of shoulders: Verticle clearance: GRADE OF DRIVEWAY % OF ROAD o/ � o ROAD ACCESS , r � Length: ,� 6 L�S Width: Surface: Condition: REMARKS Q-4 L2:-Jo-t�, —j—y I uov?-,V�, UA-&o `T �,� Z N L MASON COUNTY PERMIT NO" "" BUILDING PERMIT APPLICATION 0933K 426 W. Cedar • P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICA T INFO MAT ON CONTRACTOR INFORMATION Owner OA p Company Name /' Mailing Addre b Mailing Address ,v I -4 1.).1. L, City P State WA Zip Code 9 EZ 6 City State LC r Zip Code `61 y Z u. Phone Other Ph. Phone 'LZ 3H Other Ph. Lien/Title Holder Contractor Reg.#% �ALif 9 5/[ 'Exp. S u E mail address E Mail Address Drivers Lic.# OA CP DOB 7/ Drivers Lic.# DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New S ,ptic k Existing Septic Connect to Water System >L Name of Water System ( � �cn IJ��� i-tJ '_rAlG(f T Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No. C' 0 Fire District Legal Description ( W L ° 7 / r\ 2-7 Site Address (Please include treet ame, strew number and city) �T C `J Directions to site ^ �_�' A / �^ 0 /1. O -T P 4&ZL efEG &.A /-' L/ �L L '�D O Will timber be cut and sold in pa"rcef pre aration?Yes o Is property within 200'of Saltwater _Lake River/Creek �/o Pond Wetland--ALL—Seasonal Runoff�t_St'earn Slopes or Bluffs > 15% b'I ' Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New---)LAdd Alt Repair Other PRIMABY.RESIDE,NCE :x, SEASONAL ❑ Use of Building_f/"�in4 Alt' iwL Describe Works No.of Bedrooms—lL—No.of Bathrooms a Square Footage - 1st Floo 2 loo 3rd Floor Basement Deck 50 o Covered Deck q.ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permis- sion from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this applica- tion or the or proposed i the applica. n, I h obtained permission from them to_appI fo71) ' permit and ff d st-the Work proposed. X 1 Date: L ll�, wn / wners resentative/Contractor (indicate which one) ?n,." FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd SEEReceipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department 3 6 Planning Department ,�iJ�-fJ� 010L/9 m44 Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee G y 3 EH Review Fee Plumbing & Base Fee l`6 - C'U Planning Review Fee Mechanical & Base fee �S�-�-4 Other Wood/Gas/Pellet Stove Fee State Fee -S Violation Fee �-�� Pre-Paid at Submittal Valuation $ 7 �—G TOTAL FEES 710 14 1 7d, q(y rc 13V 3s- --_--.o,.�_ .-.._—.�-,,:,^--+..-_...:,.��-,a;+-+�'-,«e.+r.r•,.-�".?v'";'rsrse;tt'.�^ r+�A!.*'atS° ,'"'c!. -'+^�"or^=,n'9r"nt�"+r�FP+R1^!dn'T;�v Yr,.;.... ,.,,,,,, . ... MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670• Belfair (360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANTJNFORMATI N T CONTRACTOR INFORMATION 7p Owner Company Name Mailing Addre C' - = Mailing Address L.G.y A 1¢rfr= F City Q ��- State LLAA Zip Code City tate �,4. Zip Code � Phone Other Ph. Phone-,5 c�/Z61— eir5f Other Ph. Lien/Title Holder Contractor Reg.# Exp. E mail address E Mail Address Drivers Lic.# '.4� 17 DOB 2 . /77 ILE Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic >1 Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. Fire District Legal Description tJ I r U-) 40, Site Address (Please include�streeel name, street number and city) % k Ei'%Z "A A Directions to si_tg / 16 rn; Is property within 200'of Saltwater '�Yall�-Lake River/Creek .� Pond � p P Y Wetland Seasonal Runoff Stream r Slopes or Bluffs > 15% H/49 TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor. 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_ LPC-L--- Natural Gas_ Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan --� Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Z Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Z Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF 7ORK IS BY MEANS OF A PROGRESS INSPECTION. t !/i ?./ /� Date: 19/(1 4 X �° "" AR 0 9 2006 Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group-Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood /Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES El Hodge engineering • inc. 6-18-06 SL #6-0929 RE: Lot 9 617 SW 4" Place: Renton Hodge Eng. Project 6.0225 Reality Homes plan 2262 Porch Footings / CS14s interior Wall To Whom It May Concern: I have provided the lateral load engineering for the Reality Homes plan 2262 for Reality Homes. 1. At the request of the builder I have reviewed the 12"x12"x8" concrete pads placed at the front porch. These pads were not sized by the designer. These pads are acceptable for the design loads. The footings shall bear on native soil or firmly compacted fill. See attached plan view of the area in question and footing calculations. 2. Per the builder two CS14 straps were missed. As an option the builder may install the CS14s on the inside of the stud wall in places where specified on the engineering. The straps will connect floor to floor and be nailed with (34) 10d nails and cut to a length of 38" + clearspan. Please contact me with any questions regarding these conditions. 10-1 SL SSjONALyCs EXPIRES: 1211Q! This letter is the professional opinion of the engineer of record and regards his engineering only. This letter does not allow the builder to disregard Code requirements. Any schedule or cost impact is the responsibility of the builder or owner. The Building Inspector has the final authority to allow field changes to approved building plans. This letter may be signed electronically in accordance with WAC 196-23-070 and Chapter 19.34 RCW Hodge Engineering, Inc. Jahn E. Hedge P. E. 26ox Jahn Ave NW Ste.At.Gig Harbor,WA 98335 (253)857-7055 Fax(253)857-7599 3 r W 5068 N (V A a Nrrtp- r- Oizop mza$ x 2 886 0266U? BEDROOM 2 io DINING e N STUDY Up vy 6'-0" 14'-0" BXBDFn MA BA' 5040 HS zn :GXB DFn BXB DF#2 B%B DFn 3068 3068 '-8 7/8' 8'-0" 5050 HS 5060 HS C Type X Sheetroc4 10'-8 7/8" 5'-0" 1/4 4'-3 5/1 3'-5" 5'-0" L3-101116- strap wH to on warm walls. s at Studlardfords 10'-2114" 4'-35/ 2'-4 1/2" 12'-31/16" 11" 4"Bollard for Crash Protection WINDOW SCHEDULE OTY FLOOR SIZE DESCRIPTION 1 1 4036 RIGHTSLIDING 1 2 5040 LEFT SLIDING 1 1 5040 LEFTSLIDING 2 1 5050 RIGHTSLIDING 9 GARAGE 2 2 4040 RIGHTSLIDING N 1 1 6040 RIGHTSLIDING 1 2 6044 LEFT SLIDING 2 1 1350 SINGLE HUNG 3 2 1220 14X24VERT 3 3 1220 14X24 VERT 1 1 5040 RIGHTSLIDING 1 1 50610 EXT.SLIDER-GLASS Main Floor Plan Scale: 1/4" = 1 Foot sses spaced at 4'X 12'DF n BTR.BEAM n f Scissor Truss G a raq a Notes I 18070 ONO i Title: Job# e Dsgnr: Date: 1:13PM, 10 MAY 06. Description engineering inc. Scope: Rev: 580000 -- Page 1 User:KW-0607122,Ver5.8.0,1-Dec-2003 Square Footing Design (c)1983-2003 ENERCALC Engineering Software concrete footings.etw:Gal�laticns Description 12"x12"x8"Concrete Footing with(2)#4 Rebar each way General information Code Ref:ACI 318-02, 1997 UBC,2003 IBC,2003 NFPA 5000 Dead Load 1.250 k Footing Dimension 1.000 ft Live Load 0.000 k Thickness 8.00 in Short Term Load 0,500 k #of Bars 1 Seismic Zone 4 Bar Size 4 Overburden Weight 0.000 psf Reber Cover 3.000 Concrete Weight 145.00 pcf fc 2,500.0 psi LL&ST Loads Combine Fy 40,000.0 psi Load Duration Factor 1.330 Column Dimension 4.00 in Allowable Soil Bearing 1,500.00 psf Note: Load factoring supports 2003 IBC and 2003 NFPA 5000 by virtue of their references to ACI 318-02 for concrete design. Factoring of entered loads to ultimate loads within this program is according to ACI 318-02 C.2 Reinforcing Rebar Requirement Actual Rebar"d"depth used 4.750 in As to USE per foot of Width 0.173 in2 200/Fy 0.0050 Total As Req'd 0.173 in2 As Req'd by Analysis 0.0002 in2 Min Allow%Reinf 0.0014 Min.Reinf%to Req'd 0.0014 Summary Footing OK aw 1.00ft square x 8.0in thick with 1-#4 bars Max.Static Soil Pressure 1,346.67 psf Vu:Actual One-Way 0.00 psi Allow Static Soil Pressure 1,500.00 psf Vn'Phi:Allow One-Way 85.00 psi Max.Short Term Soil Pressure 1,846.67 psf Vu:Actual Two-Way 7.28 psi Allow Short Term Soil Pressure 1,995.00 psf Vn'Phi:Allow Two-Way 170.00 psi Alternate Rebar Selections... Mu :Actual 0.14 k-ft/ft 1 #4's 1 #5's 1 #6's Mn"Phi:Capacity 2.76 k-ft/ft 1 #Ts 1 #8's 1 #9's 1 #10's 319