Loading...
HomeMy WebLinkAboutBLD2001-01024 Final SFR and Garage - BLD Permit / Conditions - 3/20/2002 Inspection Line(360)427-7262 E MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 lip, RESIDENTIAL BUILDING PERMIT BLD2001-01024 OWNER: WILBUR HOEKSTRA 275-6734 RECEIVED: 10/02/2001 CONTRACTOR: STEPHEN JOHNSON INC SITE ADDRESS: 471 NE CUTLASS WY BELFAIR ISSUED: /15/2001 0 PARCEL NUMBER: 123303390001 EXPIRES: S/15/2002 LEGAL DESCRIPTION: GOVT LOT 4 EX SEE SURV 7/19 TR 1 OF SP#2629#612990 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE AND GARAGE N SHORE RD RIGHT LARSON LK RD 1 MILE LEFT CUTLASS 5001 STAY LEFT DIRT RD, LAST LOT ON LEFT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: 2 Occ. Group: R-3 Lot Size: Deck: 314 Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,444 Garage-Attached 528 Valuation: $88,837 Building Height: 14 Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make Length: Ft. Front: S 60.0 Ft. Shoreline: Ft. Water Body: Rear: N 250.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 25.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: 11 Side 2: W 15.0 Ft I I Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Bath Tubs 2 Ventilation Fan 3 Plan Check Fee KLw 10/02/200 $47.00 1309 Lavatories 2 EH Plan Review PSD 10/16/200 $50.00 1337 Water Closets (Toilets) 2 Building State Fee MRG 10/19/200 $4.50 1337 Water Heaters 1 Building Permit Fee MRG 10/19/200 $916.75 1337 Clothes Washer 1 MechanicTFN— MRG 10/19/200 $21.75 1337 Kitchen Sink 1 Mechanical Base Fee MRG 10/19/200 $23.50 1337 Dishwasher 1 Plumbing Fee MRG 10/19/200 $75.00 1337 Hosebibs 2 Plumbing Base Fee MRG 10/19/200 $20.00 1337 Planning Site Inspection SAL 10/31/200 $70.00 1337 Total $1,228.50 BLD2001-01024 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2001-01024 CONDITIONS FOR BLD2001-01024 1) This applicati ct to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 2) The use, handling n storage of hazar aterials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. 3) Provisions for surface/subsurface drain a ontrol must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction whic is pr posed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned wor y affect your project. 4) Proposed struct` e or any portion thereof greater than 30" in heig ade line, must maintain a minimum of 5' setback from all property lines, easements and 10 rom all County and State Road right of ways. 5) All approved plans are required to be on-site for inspection purpose . If a inspection is called for and plans are not available on site, then approval will not be r n d. In addition, a re-inspection fee in the amount of$47.0 per hour(minimum 1 hour)will be charged and must be collected by the B ' ent prior to any further inspections being performed or approvals granted. 6) In acc nce with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspe 'o . A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or co r ail to post the address on site prior to requesting inspections. 7) The a eview check list and corrections, along with the Energy Compliance Worksheet (when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site or the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building ins e X( BLD2001-0102 Please refer to the following pages for conditions of this permit. 2 of 4 8) All slabs within the heated space shall be insulated the top of the slab to the bottom of the footing X minimum R-10 for at least 24". Monolithic slabs shall be insulated around the perimeter from 9) The "approved" plot plan is required to be on-site f(or)inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval ill not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour)will be charged and shall be collected !PJ ilding Department prior to any further inspections being performed or approvals granted. 10) a nt ructure must comply with standards setforth per 1997 UBC Chapter 18 regarding descending and/or ascending slopes. 11) An ion of any structure over 30" in height from surrounding adjacent grade must be set rom all utility and drainage easements, a total of 10' from each property line, or a variance must be obtained from the Building Department. X 12) All changes to "approved" building plans that effect compliance with the Uniform Codes as am ded and adopted, or any other Mason County or ' r ulation, must be reviewed and approved by Mason County prior to construction. 13) All pro y lines shall be clearly identified at the time of foundation inspection. X 2 14) All building permits shall have a final inspection performed and approved by the Mas n unty Building Department prior to permit expiration. The failure to r uest a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-c ant with Mason County ordinances and building regulations. X 15) All per s expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for acti n fora period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the per er have prevented action from being taken. No more than one extension may be granted. X 16) Witho( n approved geotechnical assessment or report new construction must maintain a minimum 50 foot vegetated buffer from the crest of slopes with an inclination of 15% or greater. This setback is to be measured from the foundatio structural supports. Any disturbed areas within this buffer shall be revegetated with deep rooted native plants upon completion of project. X 17) All upland areas disturbed or ly Bated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X — 18) Applicant ackno es at this velopment is subject to policies and regulations of Mason County Comprehensive Plan and Development Regulations. 19) The Washington ate Clean Air Act prohibits the burning of any construction or demolition debris in an outdoor fire. BLD2001-01024 Please refer to the following pages for conditions of this permit. 3 of 4 This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before b ilding can be olsi cc p' d OWNER OR AGENT � � DATE: / i BLD2001-01024 Please refer to the following pages for conditions of this permit. 4 of 4 _ 4r �^ /-71 MECHAMQ ��� MOBILE HOME Fsiis.Suck date a-� ), Rbbom date by s 1'2 pas PtPkv { Fo-u-r4atjon Want date by set up by date INSULATION date L -/z5"-Q by �/� , daterrs by date by FRpM1Np FIRE DEPT. dais -' d by date U L- btf L date by OTHER PLUMBINCI v� Attic Grmxxtwork date by date 0— by WALLBOAM tMUNG D.W.V. date J! A)Z by date 2-Ld by T FINAL IN PEqTION Water Line date by date3: j.2 � by y - date by , / — 6 ti S vim' v cA .u,1 .4 20