Loading...
HomeMy WebLinkAboutBLD2004-01965 Cancelled Roof Repair - BLD Permit / Conditions - 7/20/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton,WA 98584 " L� RESIDENTIAL BUILDING PERMIT BLD2004-01965 OWNER: DAVID CROSSWHITE RECEIVED: 12/30/2004 CONTRACTOR: LICENSE: EXP: ISSUED: 1/20/2005 SITE ADDRESS: 70 NE KIMBERLY DR BELFAIR EXPIRES: 7/20/2005 PARCEL NUMBER: 123303200180 LEGAL DESCRIPTION: TR 18 EX, 19 &20 OF GOVT LOT 3 PROJECT DESCRIPTION: DIRECTIONS TO SITE: ROOF REPAIR, SIDING REPLACEMENT ON FIRST FLOOR,ADDING SR 3 TO SR 300 -4 MI. TO MISSION CREEK, 1.6 MI. TO RAINBOW, COVERED PORCH, REMOVING DECK ON BACK OF HOUSE AND IMMEDIATE RT ONTO CHINOOK, RT ON KIMBERLY, 2ND HOUSE ON RT. REMOVING STAIRS FROM FRONT. General Inf ormation Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: R-3 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No. of Stories: Occ. Load: Building: Carport-Attached 120 Valuation: Building Height: Occ. Status: Primary Basement: SIDE.ROOF Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 67.0 Ft. Shoreline: Ft. Water Body: SEPA?: No Model: Width: Ft. Rear: W Ft. Slope: Ft. Shoreline Desg"i Not Applicable Side 1: N 38.0 Ft. pp Year: Serial No.: Side 2: S 170.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type City. Type By Date Amount Receipt Plan Check Fee CMH 12/30/200 $54.11 B12004 Planning Review Fee CMH 12/30/200 $155.00 B12004 Violation Investigation Fee CMH 12/30/200• $58.00 812004 EH Plan Review CEW 1/6/2005 $75.00 812005 Building State Fee ARC 1/10/2005 $4.50 812005 Building Permit Fee ARC 1/10/2005 $83.25 612005 Violation Fee ARC 1/10/2005 $83.25 B12005 Total $513.11 BLD2004-01965 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2004-01965 CONDITIONS FOR BLD2004-01965 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at X 800-64V-Q982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 2) The internationnl code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roaJ d nect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ' 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will no be ranted. In addition a re-inspection fee refer to current fee schedule minimum 1 hour will be charged and must be collected b the Building � t 9 P ( ) 9 Y 9 Depar !entt prior to any further inspections being performed or approvals granted. X 4) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and-shall contrast with their background.- Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspe�tiy X �,C.i 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or rem u I of approved documents will result in failure of required building inspections. X 11J 6) All replacement windows shall have a U-factor of.40 or less. Replacement windows that do not meet current egress conditions shall maintain the same size ening or better. xo, BLD2004-01965 Please referto the following pages for conditions of this permit. 2 of 4 17) All exterior wall cavities exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspected prior to covering. X 8) Existing roof shall be insulated to a minimum of R-30 if: The roof is uninsulated or insulation is removed to the level of the sheating, OR All insulation in the roof ceiling ceiling was previously installed exterior to the sheating or nonexistant. \ — 9) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Buildin Department prior to any further inspections being performed or approvals granted. X�VP.J 10) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X Vl L 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in per revocation. X 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For.any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your projec X 13) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordincee or regulation, must be reviewed and approved by Mason County prior to construction. X 14) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect sell be made prior to requesting additional inspections. 15) All property lines shall be clearly identified at the time of foundation inspection. X 16) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason o my ordinances and building regulations. X BLD2004-01965 Please refer to the following pages for conditions of this permit. 3 of 4 17) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (ollder ,ve prevented action from being taken. No more than one extension may be granted. �18) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, nnectr , an flashing. Install metal connectors approved for contact with the new types of pressure treated material. This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property qnd structur for review and inspection. OWNERORAGENT: DATE: BLD2004-01965 Please_referto the following pages for conditions of this permit. 4 of 4 co r o CONCRETE MECHANICAL MANUFACTURED HOME o '- f, Footings I Setbacks Date By Ribbons 0 Date By Gas Piping Date By cin Foundation Walls Date B y Set-up Date By INSULATION Date By B G / Slab Insulation Floors Final Date By Date By Date By FRAMING Walls FIRE DEPT Date By Date By Date By PLUMBING Attic OTHER Groundwork Date By Date By 'WALLBOARD NAILING D.W.V. Date By Date By FINAL INSPECTION Water Line Date By Date By ` ` `<< ,z Date By CD CD 1 --N 1 0 � 1 CD 6 C0C G rA, L N r O � O 8 � � a � O' ,p (n 1 o El d C d O h MASON COUNTY PERMIT NO. ���}`��L'P�� ,5 BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 a Or Shelton (360) 427-9670• Belfair(360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner T)l vo- � 1—krk— (XnSS i KAU �c Company Name Mailing Address 11) ME I�I tM�'1Q��I A t- Mailing Address City . -lf! A State of Zip Code) G9-52X City State Zip Code Phon _A11-3:t5'1 Other Ph.. Phone Other Ph. Lien/Title Holder 0-0m"ogA W 16 f- Contractor Reg.# Exp. E mail address — J E Mail Address Drivers Lic.#i.-R�S DN 5496-1 DOB I l�I I p,' Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Fxisting Septic Connect to Water System Name of Water System .215-h r?.�d 1_r0L(-+5 Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No. ° IQ;330 00160 Fire District ►\AIV11=P0E::�3!, Legal Description M IT5 EX ° 19 4 -\0 or- C�!!T LO1 3 Site Address (Please include street name t street number and city) -7O N F_ �Z mla•e..I-I is D t- �.l�1 r' Directions to site 4ALV A -E -4-r� -� U)IA 3DD , W_I -+n . NA 15seo-n n rx-1 1_0 I In�nMI i Y1n rIPc�o CA I� +r+ n"GI t� C'lrusled� . lr� o rl IZIM6.1.r`IU , tnrl° InoU Win_ o to tr-4- Will timber be cut and sold in parcel preparation?Yes%No J Is property within 200 of Saltwater V)D Lake inn River/Creek no Pond inn Wetland inn Seasonal Runoff Inn Stream inn Slopes or Bluffs > 15% "n Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?YestNo °" 0 TYPE OF JOB - New Add k All Repair X Other PRIMARY RESIDENCE ® SEASONAL gm_ Use of Building Describe Work `Fe[Da�I No.of Bedrooms No.of Bathrooms 9% Square Footage- 1st Floor R02 2nd Floor 11901 3rd Floor M,/A Basement Ilk /A Deck Covered Deck WA Other N/A Sq.ft. N/A Garage '594- Attached V Detached Nk/A Carport Attached a-A Detached M/A MANUFACTURED HOME INFORMATION - Make /P< Model Year Length Width Serial Now - No-of-Bedrooms No.-of-Bathrooms Type of Heat r- -Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit.revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary i i t w is required from any easement holder or any other party in interest regarding this application or the work proposed in the appli i permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for revie'6 inTUtioT04 F`O PROO �CONTINU TION OF WORK IS BY FANS OF A PROGRESS INSPECTION. ��JJ X �''���� �; .� Date: IAlAto D� BELFAIR OFFICE Owner/Owners Re resentative/Contractor indicate which one f , FOR OFFICIAL USE BEYOND THIS POINT Accepted by: ( Date DEPARTMENTAL REVIEW APP OVED DENIED NOTES Building Department �� +�" (/°� Planning Department r ,� Environmental Health Department Public Works Department Fire Marshal FEES Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee el /_� 1 5 3 Pre-Paid at Submittal Valuation $ TOTAL FEES Prepared by: MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECK T SLI Owner's Name:_ Cn)s .�sw /1 Date: 1 Z Reviewed By: ' Documents: U _✓Building Permit Application Completed 0 EC! 3 a _ZPlanning Intake Checklist Completed, 2094 jZSite plan includes:Allowable building area,roof overhangs,decks,etc. 3ELFAIR OFFICE aratus Access Road info required? Yes/No —Energy-evde Application Form-HEAT FUEL TYPE a Plumbing Application-WATER HEATER FUEL TYPE Engineering Included&info transfeymc nto building plans:Design criteria:Code reference:jjQCsnow load Seismic Zone(circle one): D 1 orf D2 I Calculation incl(circle): Vertical Yes / No ,Lateral Yes / No Constructio Plans: 3 COMPLETE SETS Mans Legible . ognized Scale Elevation Views _)----cr oss Section 1�undation Plan Roof Framing Plan moor Plan-Use of Rooms Noted —Deck Framing Plan,incl cov,porch framing Floor Framing Plan'-all floor levels including loft,crawlspace,etc. Plan Details: ,/�I ✓oof framing details,truss lay-out may be needed `-i U� _Wall Framing-Does bearing-wall height exceed 10'?(Engineering may be required) _Floor framing: Floor joists: ,Floor beams: Window headers. Typical header: V/Foundation: footing size,reinforcement Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required,see details) ' _Non-Conventional Framing-Foam Core,Logs,etc.?(Engineering is required) _Point loads trace to footings below? _Slab insulation shown _Landings at all exits? _Heated By Furnace-Location of Furnace _Fireplace/Stove Information Shown-Fuel Type? Window Sizes Marked on Plans Braced Wall Panels(BWP)[also referred to as shear walls]Reference 2003 IRC Section 602.10: Braced Wall Panels(BWP)Marked on Plans? YES(continue below) NO(lateral analysis included?) 4'Exterior BWP's located at comer,OR check option below: 4'panel within 8'of comer with 1800#holdown ,or 2'comer panel and 4'BWP located within 8'or comer R602.10.5(see detail),or 2'8"Alternate BWP(ABP) _4'Interior Braced Wall Panel(IBWP),within 8'of corner,not to exceed 25'o.c. EXCEPTION:spacing maybe 35'o.c.in order to accommodate one single room not exceeding 900 SF,length of wall shall be required length multiplied adj.Factor,from Table R602.10.11 (25'-30'use factor of 1.2,30+'to 35'use factor of 1.4) Continuous footing required under 2-story structures in D2 or see exception in 602.10.9. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3)End of BWP extends more than 1 ft.over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc:fireplaces,chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. COMMENTS: b MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Processing/Inspections/Addressing Mason County Bldg.III 426 W.Cedar P.O.Box 186 Shelton,WA 98584 (360) 427-9670 Belfair (360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 October 28, 2004 NOTICE OF MASON COUNTY CODE VIOLATION David W. and Lisa A. Crosswhite 70 NE Kimberly Dr Belfair, WA 98528 The receipt of this notice shall constitute service regarding notification of violations of the Mason County Code,Title 14, Building and Construction. The violation(s)are occurring at the following property: Enforcement Case File No.: ENF2004-00461 Parcel No: 12330-32-00180 Site Address: 70 NE Kimberly Dr.,Belfair,WA ❑ : The Mason County Building Department investigated on 10/25/04 a,complaint regarding non-permitted construction at the above location. The building inspector noted that the complaint appeared valid and posted a Stop Work Order for failure to obtain the required permits prior to construction/demolition. 1. Records on file indicate that a permit was.issued in 1992 and final inspection complete in 1993 for the construction of a 2 story addition. After the final inspection on 12/13/93 and before May, 1998, a new window package was installed in the original structure without a Mason County Building Permit. Photos attached. 2. Between May 1998 and October 25, 2004, a composition roof replaced a shake/shingle roof that was on the original structure without a Mason County Building Permit. Photos Attached. 3. Between May 1998 and October 25,2004, a deck previously attached to the back side of the structure had been demolished as had the exterior stairway from the 2nd floor of the garage addition. Presently,this presents a life safety hazard and must be corrected immediately and requires approval from the building department. .4. Between May 1998 and October 25,2004,the front door had been replaced and' enlarged requiring the alteration of framing without a Mason County Building Permit. 5. As observed on October 25, 2004, on the back side of the residence the shear connection to the bottom plate had been removed in violation of the 2003 International Residential Code. Photos are attached as well as copy of Code Section R602.3. 6. Recent construction,as admitted to by Mrs. Crosswhite on a phone recording made 10/25/04, includes a covered porch. *There are no regulatory statute of limitations in regard to building.code violations. According to the Mason County Assessor records,parties named above hold legal interest in the parcel and are therefore subject to enforcement action for failure to comply. In order to bring your site into compliance you must: 1) Obtain the required after the fact permits. Submit permits prior to November 30,2004 Please make the necessary-arrangements to achieve compliance prior to November 30, 2004. If the permits are not received by November 30,2004, we will pursue additional enforcement action against you, including but not limited to civil infractions, liens against the property through the Mason County Hearings Examiner process and/or criminal prosecution as allowed under Title 14 and Title 15 of the Mason County Code. In the event that you feel you have received this notice in error or that the facts are inaccurate, I strongly encourage you to contact me at(360)427-9670 ext 356 to discuss your concerns immediately. Sinc y, ami ff Building Insper/CodeEnforcement Cc:Property File -- I - 12330-32-00180 Crosswhite 10/25/04 t, AQI ti • } r ..� �. s r•"k. i � F �j / �' �� �� _._.._. _____. • t$ 's ■ems : . RVAI lilt ski ■mom■ MOONS! no MEMNON alaaurma!lafa■lnaa ■al ■/ga�aaatNln ■ 1 NaaaBN■af won"alrlvlal=aaa■1N/la N�■/!■SI ';. -. Y■■r■■ram... . a�.�:�.. ■f r■■\ll l■NaalNN■ar■laNfNlf�a\lf■aaafaa ■■ 1 l■a■aflNllNNla ■iaall ■■■n■■aN■mf■aN■f■ n■fn■ 1 . � - rr■■■■■rr■r■rHr■rr■■■a■rr■rr■■■r1 ! n■!!!aa■/n■t■!.■t/aaaataaala!■■ ■■■■/af■ \l■a■■a■ ■■aaff a!a■ 1 1 ■\■a!n■fa■!laf■!fa■■a�■!■■■aEa.�t\ • ■1lla■a■/ff/lNaflNafNal■ ■ ■fal ��� r■a!■d■■r■■r■r■■■■■uNHHru r■1 to■!alas■!/.■/!latltlaltttat■!a a=1 !aaalRNN�a a■=-aa■memo■Na■■1 ,� ur■ruuruN■Yr■HNruuN■■ � nN■f■.!!ta!!na■!/!a■/t/a WIN N�OMMOMMMMO s�all a\l ■aaanaal Nfomna■aalaln■■■f■!■!a■flf�f00, ■!I ■lr■ua\ata ■■��■arta■! rNONE a■/lafa■I ■�iiaiaiiaa i==iii=iiiiiiiiiiiiiiiii ..*' N lNla■Naf Nfl1■■laf of■■■fal■■ll ■■rarrr■■r■■r■■■■rrrr■rr■r■r■■■■ri I aa■tlaas a!!aa!!laaataa!/!llltlaal�l ■1 I�aaN�as■■a■lafaf�aaaa■!ff■ff■lfla■ ■1 �' --a/tea■l!!■■aaaa■aN/■!■f■a--'-Rii ■I `•t aatalln.aaunainaln a!!a a■aa n■1 iialaeaaiiiifalian�afiill%uso iil ■1 - `*- aftaNaNfltl/fafaaat�a!=at alEN/all . ■rrrr■ra■rr■NrNN■■■rN■■ ■r oral ■I aa■■laaaa!!aa!ltaalaal■t a no aa■I ■1 ■■NaN■a■■■■■!■falN■■■1■ ■■■a■aa■1 ll ■1llaan■aanoaf■/lall■l■ ■■llaaall al afliaa■■■!■flafffifla■p ■tNa■\ll all ■■r■H■rrN■r■■■■rr■r■a!r■■N■■f al ■1 nNa/a■N!a■aaN lmmalmnsom al aaH■laflaa■1lHaa fla�\■�Ar■all ■1 ■aflaaf■f■■ad ■aa:1■■■a ..■■■1 ■1 \■faanaaan /n Ulna■lYla nlcommommossof ■aalN�nalatn■ aaaattata■R!a■■■Nartlaa■!an■ tNN=■■Nagonla■1 ■alN alaflN!\■ araaaa ■aNa■aNfalN■■aa/�■AI'..�■■/■a�lfMa■! 11lnm/awi n a■aaal ■■!a■■!!■■lN■aa! flNaf■■ ■!memo■flat!■aaaalM/atnf�■f\fa■a■ aalaaalf■n f■!!aa■I .NNfI■ll■■.f■■af■ ll■tatatlfffa ■afNl�lal.N�altall��Nt/a■!/N■�/ =ll a aW■■■N■N■■■ r■■■H■rrf■rrN■d■r■f■ra■■f■■fir■ of lrf:�I■H!■■!■■r■ ■■■■■r■■ ■■daRYr r■■r■■■1 ■!!n■t!laal!!!a■lttt ■ ■■■■an■aatltnaalta■ttt ■►atvrw■nNataa/afa alta■u�a■aaaa■1 ■■loom■■a■aNaalttaa /■ l/a!alfllf■■!!f■af�alNo 11► ■■!!/■lf■■a!■all■�pn la■r'*�,a.�■ /aaall 1NlllalaNflfllNflNN aifff ■lff■■It�oo�t■!lalAa�■N■■a�■la■1■lflla■f■N■ta■l■a lfanl ■�laall laaaf ■■■i�iiiiiiiif■rNirN■1frNiiiiiiiiini�M ,�r.■1■ri■NiiiiffrlNrdlaa■.s�w ■ Midland IZIMEN, W�q ■i�.wasNo=i .■moor ■a/a!a■laaalafltltaff NaNp�� BtNtt■Ntaa/a■taa/tf■t/ta■tttaaaala■alaaa■N■ aaaaq ■aH■■ 1rNfIHa■lao■lN!■NaNNNaIM NiW asaln rot■■■a immfaaaa■aa■NNNIM■Nl /a a!a■ll ■■■Vln■■Na■laa■paaaB�afaltalN7r��laa l■WllllalL7af■It/lafll■■aaNaaaN■aaall/aal■.1/�� ■" I alll■lllftlal■■■■l■■l/Nall !■lll!■a!{�lllia nmN Nl■r■■a■r■■!!Ht■■!!■rrrrr■rrr■rr7r■rrrr■■rr=fIl ll\a 1 ■rr■r�t■r■rrH■roomtdlH■dr■toolaaNN■N■rV■_�a■■.++■daa■rr■■■■R. !w!■�■YrrN■Crr■fir■■r■Mr■N■/r.•:■■r�H■tr�■,nrr ■rrr■ .■■■■r� irNiidi%■NllrNr:■■■Nla■fr/adta!:�a■!1ll/f■H/amNa■■f NNIIN!f■llpNMlal�■/aW!■arara■la■/HN■lrlHtnr�a■abaraar■ arar■� rn� u Samoan" N ■\wN!�■.Nma\arfafrl■lal■NY■■i�Now, frlir■0►l1■-�.urRaNa apa�t�ua■ a■�l1 ■l\ ta■lmnalala■aalallatala■l■■a.■■■■■■■■■■ .aaal�a■a■\l■af�.■■■■a■!ta ■aa/a:��iN■aaNllaNaaaNNu■laa■lNlr■Yalalallff■a�itaa�liaaa llNaaaan ■Nnlllaalla alaalfann ■■.N.x�rYN■ ■■■■■.■.■■ �laaaaNa■1l► iNaalii�laalaa■llaat /rrNNrdrrrN■N■■r■■ ■■rrrM4rrr■J ■ ■■■■■r■■rf ■rrdrfrd.H Nr■rdrfr■■■■r■■r■r■■ ■!an■f!n■w!o ■/a ■naaaanl■ae n ■ :�.a`�e■asaar+ar.■!na■vaa■!■w ■atN N Ma■lfaaNllaal■Nal■ as N waanl on a slant■ lelp2 rasaur..aalal■aliasf■/�l■ ll ■Ilia■ lla ll t/1B1Raafalallllan Y■.■...�.■■■aitw■a■ ■N..11■Ne�N:aallaaY■N� f/aallln l■aaa ME 1 tmaa!naa/t/a■!!laaaaaaamaaa■■alaa!!!n aaal■llaNl!■■1lNrra■■rf ■rr■fr■■■N■■■� � � Case Activity Listing 11/8/2004 2:34:44PM Case#: ENF2004-00461 FAZm Assigned Done Activity`' Description•'• ,Date i Date 2" .= Date 3 Hold Dsp' To By Updated' Updated I3y ENFBO15 Cert.Notification Status 10/28/2004 None TLG 10/28/2004 TLG ENFA900_ Telephone Call 10/25/2004 None DONE TLG 10/28/2004 TLG Returned call to Lisa Crosswhite. Left message that we will research her claims and contact her in a day or two with additional information regarding posting. ENFA010 Complaint Received 10/25/2004 None DONE TFR 10/28/2004 TLG ENFB020 Site Investigation/Stop Work 10/25/2004 None DONE TFR 10/28/2004 TLG ENFA900 Telephone Call 10/25/2004 None DONE TLG 10/28/2004 TLG Lisa Crosswhite called. As close to verbatum as I can get: 1/2 of the things on the Stop Work order are wrong. They have never put in new windows,there has been no changes to doors or window sizes or locations,they did not re-roof and the only thing true is a small covered proch. We need to get our fact right before we do this kind of thing,it is all erroneous information. ENFA900 Telephone Call 10/28/2004 None DONE TLG 10/28/2004 TLG Called and left message. Notice to go out tomorrow. Photo documentation and other evidence received. ENFB006 Notification of Owner 10/28/2004 None DONE TLG 10/28/2004 TLG 1st class and cert. permit by 11-30-04 ENFA510 Letter attached. See documents 10/28/2004 None DONE TLG 10/28/2004 TLG ENFA906 Telephone Call 11/1/2004 None DONE LDK 11/1/2004 LDK DAVID CROSSWHITE CALLED TO SEE WHAT WAS NEEDED TO CARE OF ENF. TOLD HIM THAT HE WOULD HAVE TO SUBMIT PLANS SHOWING WORK BEING COMPLETED.HE STATED THAT NEW WINDOWS WERE FROM PREVIOUS PERMITTED CONSTRUCTION,SECOND STORY DECK HE IS REMOVING STAIRS AND PUTTING HANDRAIL IN ITS PLACE. HE WILL BE COMING IN TO APPLY WITHIN 30 DAYS. LDK Page 1 of 1 CaseActivity-rpt MASON COUNTY 427-9670 BUILDING DEPARTMENT ALL PERSONS ARE HEREBY ORDERED TO AT ONCE TOP WORK On these Premises at r This order is issued because _ l A.M. Posted' P.M. 1;9 _-= By r The failure to stop work, the resuming of work without permission from the WARNING Building Official, or the removal, mutilation,destruction or concealment of this Notice is punishable by fine and imprisonment.