Loading...
HomeMy WebLinkAboutSWG2024-00333 - SWG Application / Design - 8/5/2024 MASON COUNTY 415NB HELTON: , 0427-97 ,EXT 400 H STREET, SHELTON. WA S BELFAIR:360-275-0 67,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT400 FAX 360427-7787 On-Site Sewage System Permit: SWG2024-00333 APPLICANT SAARELA ROBERT&LINDA ANN Phone: 360-4264221 Address: 2001 19TH AVE SE PUYALLUP,WA 98372 OWNER SAARELA ROBERT& LINDA ANN Phone: 360-426-4221 Address: 2001 19TH AVE SE PUYALLUP, WA 98372 SEPTIC DESIGNER CINDY WAITE-Septic Designer Phone: 360-701-0205 Address: 80 E PICKERING LANE SHELTON,WA 98584 SEWAGE INSTALLER B-LINE CONSTRUCTION Phone: 1.360.489.9169 Address: 2971 E PHILLIPS LAKE LOOP RD SHELTON,WA 98584 Site Address: 10670 E State Route 106 Primary Parcel Number: 322255100037 Permit Description: Repair: 2-bedroom pressure system(nonconforming) Permit Submitted Date: 08105/2024 Permit Issued Date: 1010212024 Issued By: David Anderson Current Permit Fees Paid: $805.00 (meiaonal teas may no reauIna4 upon wMaludion d syslam). Permit Expiration Date: 08107/2025 (easaa on axle pnnapaction) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staffper Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmental/onsiteloss-inspection-request.php or call: 360.427-9670,extension 400. OFFICIAL USE ONLY nNl nrcelvlu MASON COUNTY _ _5 , COMMUNITY SERVICES M TJr — Ili PuWRHMIM atom unity eeltM1/EnvlromxnGl NeaI1M11 w SWG �c, - op3W - s N Zw ON-SITE SEWAGE SYSTEM APPLICATION > z n APPLICANT - PNONE m ROBERT SAARELA _ 360-426-4221 z MAILINGAOORESS-STR€ET CRT STNE,ZIP CODE 2001 19TH AVE SE PUYALLUP WA 98372 m 6106706-S'OkOtT,CON ZIP CODE E STATE RT 106 UNION WA 9852 L' NAME OF 0661GNF.R PIIONP I N CINDY WAITS 360-701-0205 NAAE OF INSTALLER 4 --- PMVNE I I N PERM R TYPED~m^ ) DRINKING 4WTER SOURCE ` M RESIDENTNLOSS 1 COMMUNITYOSS TT COMMERCIAL OSS 1 PRNATE INDIVIDUAL WELL [I PRIVATE TM PARTY WELL I � TYPE OF MAX(%MlPna) A—i PUBLIC MTER SYSTEM I PI NEW CONSTRUCTION I UPGRADES M REPAIR I REPLACEMENT OTHER DEMILSImMM exu &WD, ❑TABLEIX REPAIR I ICO m SUSMINALS E7 SURFACING SEMGE ®EXISTING FAILURE CI SHORELINE I � -I DESYGN FORM(REOUIRED) M SEPTIC DESIGN(REQUIRED) BEDROWS 2 LOT SIZE 1 DOIX 'O'1 USUVER(S)(IF APPLICABLE) _ DIAECTIONS TO SREANO SITE CONDRION6:AH b6 1-) GO OUT BROCKDALE TO MCREAVY, TURN RIGHT ON DALEY, TURN RIGHT ONTO HIGHWAY 106, GO TO ADDRESS ON THE RIGHT SIDE OF THE HIGHWAY. WILL NEED o I c TO MEET TAYLOR TONEY TO TAKE YOU TO THE SITE, VERY STEEP, SYSTEM WILL NEED TO BE INSTALLED BY HAND. I �' $IIFRI/6FUFYADOED MADMMAm aoaDAxD TE6r HOLE6 xusT BE fLADxEDmm FCSrxOtExV.WlP6. I V OFFICIAL USE ONLY BELOW THIS LINE UPGMOEIfNLUPE 60UPVWIIIIIRI��­)(]VOLUNTARY CI fNG ❑BUILDING PERMIT OHOMESALE 13COMPLAINT C]OTHERIN6PECTOR 6BIL DOOS /I.P L LV, V.{) C(+MNFNIti!fONDI110N5T*1:o IRcffof 30MI A QOr"Q Titt:o-Zljl35 VCs I'llils Tr �' p C d C fC1 66� I � AUG 0 5 2024 D ey� RLUDRU URAWNG AND INSIA ArGN REPOPT SOIL CODES: Ve VARY O-ORAAELLY S=SANU LOAM Si I SILT CICLAY <-F.Fltll 00IE REl1UIflF.O FORFINA"pP A0VAL DATE APPUCA Nf PPP)IP O APWiWF111FeUE11 PV UPTE INSPEC NPTUHE J 1 �1 $P/mkif,' ZP�ZS l G G THIS F M MAY BE SCANNED AND AVAILABLE FOR PUBLIC VIEll'LI IWrISONCOUNTYWEBSITF. REVISED IZ/i0ots 6V1.VW0teGk 6w0LAeeriw6j ryeateZkK CAL a EKVLMaN WtaL=➢raina(ge°Roadway V(L� September 14,2024 Selo v S B Line Construction RFCF7`F p191 1001 E Phillips Lake Loop Road Shelton,Washington 98584 RE: Geotechnical Evaluation of On-Site Septic System 10670 E State Route 106,Union,Washington. To Whom It May Concern, Envirotech Engineering(Envirmech)completed a site visit on September 9, 2024 to the property in order to observe surface and subsurface conditions. This geotechnical evaluation addresses the recently constructed on-site septic system with relation to landslide hazards on and near the property. Information collected from site observations and field testing was completed by Michael Staten with Envirotech. It is our understanding that the septic is a standard pressurized system. Subsurface conditions were visually classified as silty sand with gravel(SM).The septic drainfield area is moderately to steep sloping straddling a ridge formation. It is our opinion that the drainfield placement on the ridge where the subsoils are relatively dry and protected from excess groundwater, the on-site septic system will not influence the critical slopes. However,we recommend that the effluent dosage should be increased to at least 12 doses per day in order to minimize each saturation. If you have any questions or need any further assistance,please contact Michael Staten at 360-275-9374. Sincerely, Envirotech Engineering CLYD,$' WAS I, 1T i .p q a OFF STV `ff.Ifir0.F S",NAL Michael Staten,P.E. Project Director Po isax924 Selfair,WashLngtow98528 O{f. 360-23593g+ GCLI: 360-689-6045 DESIGN FORM—PACE ONE Assessor's Parcel Number: 3 2 2 2 5 — 5 1 — 0 0 0 3 7 A design will be reviewed when 3 copies of each of the following are submitted: Completed design form that has been signed and dated. 0 Scaled layout sketch,including all applicable items on checklist Scaled plot plan,including all applicable items on checklist. •Cross-section sketch,including all applicable dens on checklist. This form maybe scanned and available for public view on the Mason County Web site. Maximum paper six. 1 i"X 17" MW PARCEL IDENTIFICATION Permit Number: SING 2024-00333 Designer's Name: CINDY WAITE Applicant's Name: ROBERT SAARELA Designer's Phone Number: 360-701-0205 Meiling Address: 2001 19TH AVE SE Designer's Address: 80 E PICKERING LANE PUYALLUP WA 98372 SHELTON WA 9858a CityState ZipcityS Zip DESIGN PARAMETERS Treatment Device ❑Glendon Biofiher 0 Sand Filler 0 Mound 0 Send Lined Drainfield ❑ Recirculating Filter,Type: ❑Aerobic Unit Make/Model O Disinfection Unit MakdModcI Other: C J Drainfield Type 0 Gravity Rf Pressure BdTrench ❑ Bed ❑Sub Surfac ip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 2 Schedule/Class SCHEDULE40 Daily Flow:Operating Capacity 180 gpd Length 24,29,18,20,25.20 ft Daily Flow:Design Flow 240 gpd Diameter 1.25 in Septic Tank Capacity(working) aa'tosnl .vronawm gal Number 4 Receiving Soil Type(I-b) 4 Separation. - 6-7 ft Receiving Soil Appl. Rate .6 gpd/ft2 Orifices Required Primary Area 400 - ft- Total er y, rifices 28 Designed Primary Area 408 ft2 Din 4 _W01 `r 3116 in Designed Reserve Area LIMITED - ft2 S -�V-�o' „ Y 60 in Trench/Bed Width 3 - ft �"� �' Manifold s Trench/Bed Length 136 It � R r' SCHEDULE 40 Elevation Measurements 1-2 it nl•wss asto Original Grainfield Area Slope 33 / Diameter 2 in New Slope,If Altered % Preferred manifold configuration used? 0 Yes 0 No Depth of Excavation UPslope 18 in Transport Pipe from Original Grade uown-clone 6 in Schedule/Class SCHEDULE 40 Designed Vertical Separation 12 in Length 120 It Gravelless Chambers Required? Yes 0 No 0 Optional Diameter 2 in Pump Required? if Yes O No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdosesiday 12(PER ENGINEER) I.t(q Diff.in Elevation Between Pump&Uppermost Orifice 100 ft Dose quantity 15 gal Drainfield Squirt Height/Selected Residual(head) 2 It Chamber Capacity(flood) INFILTRATOR 1pa0(1287 FLORID) gal Uppermost Orifice If Higher 0 Lower than Pump Shutoff Pump controls: Please check those required. Capacity®Total Pressure Head 16.52 Spot fiftimer h)(Elapse Meter G(Event Counter Calculated Total Pressure Head 102.62 ft If Timer: Pump on Pump off Comments VERIFY PUMP SIZE AT TIME OF INSTALLATION, PUMP CONTROLS TO BE SET AT TIME OF INSTALLATION, LOW PRO FILE INFILITRATORS REQUIRED. DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 2 2 5 -- 5 1 -- 0 0 0 3 7 PermitNumber: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch Ed Test hole locations 65 Drainfield orientation and layout Reference depth from original grade: m Soil logs Ed Trench/bed dimensions and Rf Septic tank 66 Property lines critical distances within layout 9 Drainfield cover ❑ Existing and proposed wells lid D-Box/Valve box locations Reference depth from original grade within 100 ft of property Ri Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts,banks,and locations 66 Laterals,trench/bed,top and surface water and critical areas lid Observation port location bottom ❑ Location and orientation of 19 Clean-out location ❑ Curtain dr m co for curtain drain and all absorption 6d Manifold placement ❑ Sand augmentation components fa Location and dimension of 19 Orifice placement Other cross-section detail: Observation primary system and reserve area Lateral placement with distance ports/clean uts m Buildings to edge of bed Other Information Ed Audible/visual alarm referenced Yes No Id Direction of slope indicator Rf Scale of drawing shown on scale ❑ Ed Design staked out Id Waterlines bar ❑ ❑ Recorded Notices attached lid Roads,easements,driveways, ❑ ❑ Waiver(s)attached parking ❑ ❑ pump curve attached Id North arrow and scale drawing 9 ❑ Evaluation of failure shown on scale bar Non-residential justification ❑ ❑ Waste strength ❑ ❑ Flow DESIGN APPROVAL The undersigned designer must be nmlji by installer at time of installation Id Yes ❑ No y Signature eft Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and detemtin ' compliance with stare and local on-site regulations: lr ?I?n- 00r0 oV Environmental Health Specialist Date CAUTION:✓ DESIGN VALID ONLY UNDER THE FOLLOWING COND The design is stamped"Approved"by Mason Public ITIO�'F7Fd,Tq Hfq`TH ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: D _ ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, ?�►� unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Date: 12/7/2015 CL a 9 E � 3 m N OL _d m m c c oo oo t i CI m � mc � � xo My i L N O CO 0 O o m a o c a w i CL m c ._ m m i w 'a = >E y m � L � wr —co 4 � tN c7 Vj ui co hco ai _`_ °' Appj MAs�cof��CT,pZ®E.�� NA M'*lA'%HE4ZTq 10 Xl : UCENSEDrSIG f 4 eni•iues u ♦ � 'w Y r'9 ',t �` x ^ � ♦ @ 0 � 0 gam. ORIFICE SPACING 5 Lateral#N18 M216 -60 rt Distance from Distance from end Length N p Orifices feeder line of end of lateral 1 5 1.5 2.5 24 2 6 1.5 2.5 29 3 4 1.5 1.5 18 4 20 240 60 4 2.5 2.5 20 5 25 300 60 5 ' 2.5 2.5 25 6 20 240 60 4 2.5 2.5 20 136 28 136 TRANS LENGTH GPM K (2" SCHEDULEN 40) ;:72 FRICTION LOSS Squirt 2 Elevation difference 100 TDH 102.62008 v ♦y lle/ l40" /yn 30 lYo s;`•1r te. /�°4a / 3f La/If 3 IV/ �AS�N0064'ry41,, 1y �® ✓/ .`o. /� b/t L 7 r y 6 ZU' O✓A Nll"4 A4 30" L�1-S aS' TRENCH CROSS SECTION �w, Al k aye Z LICENS WAn$ Ep pE51GNEq -, II,,,, ko'Mk5 Ili`Oi IV" f� 2.i 0 o L IZ„ 11„x 1 I 4, AppR P- oVF 4f4sa eovro Nu/0?10py O NMFNTA<Hfq(TH /a , i �� - 30 r c(e�u ec �f /1461s �� J/2 Valup [br�T� e J 51ow1 L m CINDYE WgitE UDENSED DESIGNER E%>igES py1N 5�1� RISER WITH LOCKING LID TO GRAINFIELD 0kc O PRESSURE LATERALSdgSakry,�+k�?Jo AZy A FLOWOONTROL VALVE \\ I — _ BLOiBN R\,\\\ RlBIRRBO FIAP CHECK / VALVE LONG SWEEP 90 d DEGREE ELBOW W �ECTION A GRRAINAIN SUMP I ? UMP TRANSPORT PIPE FROM PUMP CHAMBER 'PN d CIN 1 a LICENS' DkSIGNE E.,Rks i15n r DRAINFIELD CONTROL BOX 'I (SLOPING GROUND: MANIFQ6p BELOW LATERALS) Ill Pressure Dwributiun S}'Sten15—Recomm ended Stattdmds and Gnldance Effective Date:Febrnary 1.2022 Figure 8B. Monitoring/Cleanout Port(Example). Cap must be secured. THREADED CAP OR PLUG PLUG IN SLEEVE ;11 6"'PVC .-- -- LAST ORIFICE; WITH ORIFICE SHIELDS IF ORIFICE ORIENTATION IS BACKFILL I UPWARD MATERIAL / 1 \/ 000' O"8DO O PRESSURELATERAL 0 0o p0. ASSPECIFIED PVC HOSE OR /\\I 00 0 'no�000 LONG SWEEP \� o opp' .=. 0 00000� ELBOW j / / / DRAIN ROCK; 6" MIN. BELOW PIPE UNDISTURBEDSOIL 6' PVC WITH DRAIN HOLES; EXTEND TO BOTTOM OF GRAVEL TO MONITOR PO , INFILTRATIVE SURFACE _ 7N � c MgSo CCTC OV`Q MONITORI G/CLE NOUT PORT NcouNryFNpao?202y (EXAMP A 024 MFNTq/y�qC aAl C � p M!J+}ITE LICEry DESK NER E%PwES OSuO DOH 337-009 February 2022 Page 40 of 66 Or,einc • Technica,Date r, PVC Pump Basins Applications Standard Models Owned PVC Pump Basins are resigned to house effluent pumps, PB1854,PB2454 sewage pumps,or grinder pumps in wastewater pumping applications (Custom basins are available for specific configurations.) They are not IAPMO listed. General Materials of Construction Orenco PVC Pump Basins come in 18 and 24m(450 and 600mm) Bibbed pipe PVC nominal diameters.Bases are fiberglass-reinforced polymer(FRP), Ban PBP attached with epoxy.EPDM grommets seal all piping penetrations.A Grommets EPOM 41n(100mor)inlet elbow and holes to accommodate splice boxes and discharge piping are located and sized to specific need.Fiberglass access lids and stainless steel fasteners are sold separately. Specifications equipment is available. Model 0.0.,Inclutling rib 1.0. liquid capacity _.( In form) in from) lath Prom) PB1axx 19.44(494) 17.50(445) 1.06(0.16) -- - — PB24xx 25.63(651) 2350(5M 1.88(0.28) Product Code Diagram .:.' Ps ❑❑❑+❑+ ❑+❑ m =PllBRYIIrt R1P,t0 c t =tn a�xNam�* _— 1x�s lh. aisaorywmm� - ,Ra FNmNaunnxl 20 = xin plmNPallirtn ""� CIY. NeMYE IwPWyd^' L . 1F n5nmlpJmMYWIp L • 581 p'lmmlpmumlFN1M 41 = Sal eYnpA 52 SB1l1rJ A - 6e9eNNp sa = sad m,�nm Lfi = SB6 aInNBp S% kemr �. x5 Al nsm.e fil Ev ,OumUe' �� n. Mp p eprvo e6evla ePomq� qunllbttaAvm�- � �` ntrF b[kenom N. W' CbYWI A • Pow nJutx Wu m P� V Zf Lora unw 6 . w< F R%v lnR 11�4yyII�� �4ppR e� ren r LI Y 7�WE �/ O` sa d i3,Nmi LILEN DESIGNER 60 W i 1152< in ]x 79 10x E%nlxEs OS� j r epee 1 mr )� �ASCNCC OC �1 1 ��r zi. za isro n UNn"F,y!' 1p4 Pi pl�a�in(600mm)P824XX PVC Pump Basinmein—n.rc��Il m KRP with oPHmral oleaeout and Vent) prince Syalems'•MD-348-9843•.1541459 •www.Rroneoxxrrn Inpses&t Rm60 O12, Pepsi Nt Lib rV'i' Pumps ProVore A family and Employee Owned Company Pump Specification PRG - Series 1 hp Submersible Grinder Pumps LITERS PER MINUTE 0 37.9 75.7 113.6 151.4 189.3 60 T---'-- 18.3 50 t — - S0y"On Nry v,ig ot,,, FH�H 4O1s 40 I - 12.2 J- LL � _--I_--- Z Z Q O ♦�3a i 6.1 > T 3' o- LICENSENG DED �nniv�s c ,a 0 10 20 30 40 50 6( I1� US GALLONS PER MINUTE CopyngMOlibeMPvmp;In[2014 itan9htsreserve0. S,,lm8om subje4L to change without notice PRGPt 051"4 )600AW1,71ireAvenue Bergen NY 14416 9 Phone1-800-543-2550 0 FPn1-585-494-1839 • Email Llb"WfbenlyPumpanm • WeLlw.neLabwo,umas.eom UJI-t "Ale Car r da � G b � S tasi U,r,- .f'lwf�f Go�r+J7wjmrni G-ya. �Ja>intp f11�1�1 WCI 4riNFILTRATOR* septic tanks Paaaaatww 4 arn<tnu • Strong Injection molded polypropylone construction Ughtwelght plastic construction and Inboard lifting lugs allow for any delivery and handling • Integral heavy-duty green Ilds that interconnect with TVJTM deers and pipe riser solutions Structurally reinforced access ports eliminate distortion during installation and pump-outs • Reinforced atnicturel ribbing and fiberglass bulkheads offer additional strength Can be installed with a"to 4e" of cover The Infiltrator IM-1060 is a lightweight strong and durable septic tank. can be pumped dry during This watertight tank design Is offered with Infiltrator's line of custom-fit pump-outs Heart; and heavy-duty lids. Infiltrator injection molded tanks provide a Suitable for use as a septic tank,pump revolutionary Improvement in plastic septic tank design, Offering long-term tank,or rainwater(non-potable)tank akdeptl0hal strength and watertightness. No special water filling requirements Inlet Side are necessary The tank may be backfilled with suitable AWAY Infiltrator native sell.See installation instructions ,]+�'� Tw River for guidance. ® System ' ocro MAsoN0p0 ?2024 HEAVYDUTY LID 114"DJA NMf CUTAWAY einroroad "structural see port k sJ `. Structural A 5100118 bulkheads E.wart LICENSED DESIGN MID-SEA 11 Reinforced water tight mid-arum gaaketed connection tg1l� 1. Protectingthe Environment with Innovative Wastewater Treatment Solutions INFILTRATOR' water technologies IM-1060 General Specifications and Illustrations ,a�e,ww mWI The IM-1060 1s an Injection molded two piece mid-seam - plastic tank.The IM-1060 Injectlon molded plastic.,design - allows for a mid-seem joint that has precise dimensions n1 i A for accepting an engineered EPtlM gasket. Infiltrator's gasket design utilizes technology from the water Industry to deliver proven means of maintaining a watertight seal. The two-place design is permanently fastened using a sense of non-corrosive plastic alignment dowels and locking seam clips.The IM-1 D60 Is assembled and sold through a network of certified Infiltrator distributors. Must be backflllad and installed in accordance with j TOP VIEW A Infiltrator Water Technologies, Infiltrator IM-Series Septic 4111 �� Tank General Installation Instructions and for shallow ground water conditions reference the Infiltrator IM-Series Tank Buoyancy Control Guidance.v Please isit ManualeGuidesITANIKOIt i pdf for the latestest klformatka � Working Capacity ID94 gal 14141y 'Fatal Capacity_. 12e761d IOU I END VIEW L 1II7° Pn1a)_ xenon —:RNlue,luns�xFxnoewmlxxm,mul NLM1M WkiVl 0.21 Ono Mt11 exnm �1RLNwee.Lsxro -e°.°rownn� ton WNM Palo 2,6 to 1COE 1 e 1nNEd^T— II X MIA eMR°uP iaxR w�� 2 u+ . tat mmmi"GwW /M Otis SIDE VIEW 9 Maltllwpn pge0_MMNw. ._` 6 52MN WTs arvn Tor MWINDous Nk i MO ks 0a6 bpi _ y RA_ °.am NnLr GAsICE7 e ti �. ♦f TANK IN t 1EaGR SEAM CLIP d DI v E a LICENSED IGN R NT $a�////////� E%PINLS Rs -- NTAuf IDOMM X • i VI a VB` arttl6MWR 0M OR;a of W79 INFILTRATOR' ;;ow; °«� MID-HEIGHT SEAM SECTION walaPteohnoloSil" wYAv.InnitreteNweNccam W$PeMLL1.1t6,F1i%WrA1tV14e9i;6^017,Wi,1145AO'AWq AX1'MW;gJ'634'0.'"A N"W Cbna "Pazmx;i.820B5$2.N W(h pdmlagMrq.InRMMEp�ehar. QkM.Mfl INIAMIdd. IM llMemaxedlnlRRbfWMTMmbya.WOsOr A. Is.nWemsNin Fmmce.l,WftxWeler TMMegn learegalere4,redm».n Ma.[o. conlarc.AGoo4eglMg.PeryTa%,GwtMeSpecer.MUReall.PositttM.QtlGLLl.auhNWCUtm Wi SMgffl—oarelme1, ollnlRal°�WBIG TeM A+cR¢. PdyLak b rlatlNnoM nl PdytR4lm.NF-TTEe 0 veglMgen XedMan MIDF-nfE,INC-UIreAkI la a Iwtlema.a!IPFx's. e1201fl IARIeM Wattr TecFrtolaples,LLCMrpMa rtaemtl.HYmd;n LLRA. Mqt til! LiberV"iyPumps& A Family and Employee Owned Company Specification e3 FL200-Series 2 hp High-Head Submersible Effluent Pumps LITERS PER MINUTE 0 50 100 150 200 250 300 350 400 —__ ._.._- 40 130 37 120 34 110 100 30 27 90 A 80 70 21 9 ONcC,&4"��07? A ~O 60 18 F O�q ON�FNT4( ~ 10H�la so is 12 r 40 1701 a 30 9 xA� SZlil Am; a LICEN ED DESIGNER 20 6 L xnic¢s us�m 10 3 0 0 0 10 20 30 40 50 60 70 60 90 100 110 US GALLONS PER MINUTE Cnpynght9libeny Peaaa lI [.2022 Alingbhrcseme4. Speafloadomwb/entro[Fanyamthprtnmia. g2061GI RaWW022 M00App*Eme A,Ynw Bergen NYU016 / PDane7-0M.5/3.2550 • Far1-5854BC-1839 • Email Liberty®LdadVumpamm • W6aaw.LibadyPumG+cmm Installation Notes Pressure Distribution System: 10670 E STATE ROUTE 106 32225-51-00037 1. The prepared site plan is not a survey. It's the owner's responsibility to verify property lines, utility lines (water, sewer, power, phone and gas) prior to installation. 2. The tank may be moved as necessary to accommodate building requirements. Septic tank location must meet all required setbacks. 3. Keep wheeled vehicles off the drainfield area before, during and after installation. Tracked equipment only 4. All ground, surface water and roof drains must be diverted away from the septic tanks and drainfield. Ensure the final grade slopes away from these areas and water doesn't collect on or around them. Use swales, berms, catch basin and tight lines, curtain drains, etc. to divert all waters. 5. Curtain drains can be no closer than 10' upgradient and 30' down gradient of the drainfield 6. Exposed restrictive layers, cuts, banks, etc. can be no closer than 50' downhill from the drainfield, 7. Install access risers on the septic tanks, valve box and ends of laterals. 8. Make sure septic tank risers are epoxied or caulked to cast in riser rings on tank. 9. Lids must form a water and gas tight seal with the access risers. 10. Install effluent filter specified in this design at the septic tank outlet. 11. This system must be installed by a Mason County Certified installer. 12. Deviation from this design without prior approval from the designer and Mason County Health Department will make this design null and void. 13.This design was sized per Washington Administrative CodeWAC246-272A-0230. The operating capacity is based on 45 gallons per day per capita with two persons per bedroom. The minimum design flow per bedroom per day is the operating capacity of ninety gallons multiplied by 1.33. This results in a minimum design flow of one hundred twenty gallons per day. This creates a surge factor of 33% but anticipated flow is ninety gallons per bedroom per day. 14. Install laterals with contour of the ground. 15. Install trench bottoms level and always maintain a minimum of six inches into native soil.. 16. Install threaded clean outs at the ends of all laterals (caps must extend to within six inches of finish grade and be in a valve box as shown on diagram. 17. Install audio/visual alarm. 18. Filter fabric required over drain rock prior to backfilling he drain rock extends above the original grade, run the filter fabric at least 2 inche o the trench wall. s0*00 t^To1 FQ 4 1 foE t s OpO-FRS lily Ro O�q NM41- A(// />H System Owner Responsibilities: 1. Operation and Maintenance is required by Washington State Department of Health and Mason County Health Department. 2. The septic tank and pump tank should be pumped every three to five years or as needed. 3. System owners are responsible for having maintenance performed annually. 4. System owners are responsible for responding to septic issues in a timely manner. 5. System owners shall not at any time change or alter settings in the control box. 6. System owner agrees to read and abide by information regarding their system in the User Manual provided by Mason County Public Health. 7. Keep the flow of sewage at or below the approved design operating capacity. 8. Keep waste strength at residential waste strength parameters. 9. Spread loads of laundry through the week. 10. Do not use excessive bleach or detergents with added whiteners. 11. Do not shower, do laundry and dishwasher at the same time 12. Antibiotics can kill or impair the biological process in the septic tank. 13. Leaky plumbing can hydraulic overload your on-site septic system. .q ppo SONco". ONE 01?Ovzb O✓A NMFNT�H�`� Pp A LiCEN��n[y6�E