Loading...
HomeMy WebLinkAboutSWG2024-00396 - SWG Application / Design - 9/24/2024 MASONCOUNTY 415N6 SHHELTON 0427-97 ,EXT 40 STREET,SHEL ON, EXT 400 BELFAIR:360-275-4467.EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX 360427-7787 On-Site Sewage System Permit: SWG2024-00396 APPLICANT REDMOND ET UX MARTIN Phone: 707-5694628 Address: 22330 SE 255TH ST MAPLE VALLEY,WA 98038 OWNER REDMOND ET UX MARTIN Phone: 707-569-4628 Address: 22330 SE 255TH ST MAPLE VALLEY, WA 98038 SEPTIC DESIGNER PAULAJOHNSON` Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 SEPTIC INSTALLER SOUTH SHORE CONSTRUCTION INC Phone: 360-8014432 Address: PO BOX 963 BELFAIR,WA 98528 Site Address: 211 E Johnson Ridge Dr Primary Parcel Number: 222137700020 Permit Description: New 3-bedroom Nu Water BNR500 system wl treaty tank Permit Submitted Date: 09/24/2024 Permit Issued Date: 10107/2024 Issued By: David Anderson Current Pernnit Fees Paid: $540.00 (additional tees may oe required upon insmllabon of system). Permit Expiration Date: 09126/2027 (based an date or Ins on) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainffeld installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masonwuntywa.gov/health/onvironmental/onsitedoss-inspection-mquest.php or call: 360427-9670,extension 400. OS CEP 1 4 20?4 OFFICIAL USE ONLY Y 1�fA�O1Cf�uNTY "NRE`ENEo �9-Z4 =Z�/ N D C N COMMUNITY SERVICES Pobtl[xrM(�CemmuMry�xeaM/ERMmnmenlelXMhF1 M/^ < y „NN^ ,. - • SWG Zoz'/ - 00N(P o °z ON-SITE SEWAGE SYSTEM APPLICATION > z m n awucaur xoxE m r P Martin Redmond (707)569-4628 z MAUNGADDRES3-3IREET,CIT STATE,DPCODE •fR 22330 SE 255th St Maple Valley WA 98038 z SI}EaDORF55 STREET CITV.LP LODE 211 E Johnson Ridge Rd Belfair WA 98528 ^T N ME Cf DESIGNER Px01E I N Arrow Septic Designs (360)898-2255 NANEOFINST. PNONE I N South Shore Construction (360)275-0818 o PEAMITTYPE(e1= ) DRINKNG NNTER 901 IL�IRE$IDENTIALOSS FUCOMMUNITYOSS t]ICOMMERCWLOSS XPRNATEINDIVIDUALWELL UPRIVATETNAPARTVWELL Z IW TIPEOFNORx NfYttanel PUBLIC WATER SYSTEM , I&M.ONSTRUCTIONIUPGRADES EDREPAIRIREFACEMENT OT IIRMUIIDI(WrtMlMWly) OTABLERREPAIR 1 -4 SUB ITTAIb ❑SURFACING SEMLAGE 0 EXISTING FAILURE D SHORELINE c�DESIGN FORM(REQUIRED) I�ISEPTIC DESIGN(REQUIRED) EEDROOMB LOT SDE r0 I V lTWIdVERrS)rFAPPLDABLE) 3 BR 5 acres x DIREGTIONSTO TEANDSITEOONDITIONS'.(e..W PeYI I O Head north on N 6th toward W Alder Stand turn (R). At the traffic circle, take the 1st exit onto -� N 1st St.Turn (L)onto E Pine St. Turn (L)onto Mason Benson Rd E. Turn (R)onto E Trails 17 I o Rd.Turn (R)onto E Trails End Dr.Turn (L)onto E Rasor Rd. Turn (L)onto E Morris Creek Dr. 0 Turn (R)onto E Johnson Ridge Dr. Destination on (L). ro Yellow sign: "Redmond". Walk past shed-look for pink flags at crest of hill NIE NVSIEP ggOGEO fROYYAW ROEDFXO TE4TMWE9YUT BE MGDED KRN lE3T NOLENUMBERi OFFICIAL USE ONLY BELOW THIS LINE7OOTHEk UR IFNIWRESOURCE(WXN WWRee^^) E3VOLUNTARY QMAINTENANCEIPUMPING ❑BUILDING PERMIT OHOMESALE OCOMPIINSPECTORSOLLOGS z err j4IN eF�F�V?02 Fp ne-m-mf.7f r, I+rfl rt3:0-13" V11LAS rootkl itlf pes+ of z t ar Iiq:G-z3� v4�,M1 z13? GIrtS�}Iti Cr�ar / iLJtctt33�`Nf�`t4►,yt $pLLO0E5. RECORD DM'MHGaNOIN3TALWTION REPpVT V=VERY G=G(NVELLY S-SAND _.LOAM Si'=SIU C=C E-EXTREMELY R-ROOTS REQUIRED FOR FI'ALAPGROVAL IN EIGNaiU E MTE APPLI CATIOX E%RMTgX DATE APPUGTI :11W UED BY DaTE giaciwL 9 Z z Zvz THIS FORM MY BE SCANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEESITE REVISED IV712016 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 2 1 3 — 7 7 — 0 0 0 2 0 A design will be reviewed when 3 copies of each of the following are submitted: •Completed design form that has been signed and dazed. I Scaled layout sketch,including all applicable items on checklist r Scaled plot plan, including all applicable items on checklist. a Cross-section sketch,including all applicable items on checklist This form may b,warned and available for public view an the Mason County Web ade.:Verspium a rsize: 11''X17" PARCEL IDENTIFICATION Permit Number: SWkG 202'l - 6039b Designer's Name: Arrow Septic Designs, Inc Applicant's Name: Martin Redmond Designer's Phone Number: (360)898-2255 Mailing Address: 22330 SE 25511h St Designer's Address: 171 E Vue pest Dr Maple Valley WA 98038 Union, WA 99592 Cit State Zip City State Zip DESIGN. .ARAMETERS Treatment Device ❑Glendon Biofilw ❑Sand Filter ❑Mound 0 Sand Lined Dminfield ❑Recirculauag Filar,Type: Elf Aerobic Unit MekdMedel NuWaler 81, 1300 0 Disinkcuon Unit Make/Model Other: 500 gallon pre-trash tank Drainfreld Type ❑Gravity erPressum Trench 0 Bed ❑Sub Surface Drip Septic Tank/Draii field Specifications Laterals Number of Bedrooms 3 Schedule/Class 40 ` Daily Flow:Operating Capacity 270 — gpd Length 40 ft Daily Flow:Design Flow 360 gild Diameter 1.25 in Septic Tank Capacity(working) Nu Water BNR"500 gal Number 5 Receiving Soil Type(1.6) 4 Separation 9 ft Receiving Soil Appl-Rate 0.6 gpd/ft' Orifices Required Primary Ares 600 ft Total Number of Orifices 40 Designed Primary Area 600 ft' Diameter 3/16 in Designed Reserve Area 600 ftt Spacing 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 200 ft Schedule/Class 40 Elevation Measurements Length header ft Original Dreinfield Area Slope 3 % Diameter 1.25 in New Slope,If Altered 3 % Preferred manifold configuration used? S(Yes 0 No Depth of Excavation Up-slope 12 in " Transport Pipe from Original Grade citime"rya 11 in Schedule/Class 40 ` Designed Vertical Separation 12+ in Length 140 It Gmvelless Chambers Required? - 3Yes ONo WOptional- Diameter 2 in Pump Required? if Yes D No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdoses/day 4 Diff.in Elevation Between Pump&Uppermost Orifice 15 it Dose quantity go gal" Drainfield Squirt Height/Selected Residual(head) 2 ft Chamber Capacity(flood) 1,000 gal Uppermost Orifice difigher 0 Lower than Pump Shutoff Pump controls:Please check those required. Capacity @ Total Pressure Head 23.6 grain` Ilf-rinner R`Elepse Meter h1(Event Counter Calculated Total Pressure Head 19.49 It If Timer: Pump on 2 immune Pump off 8 hours Comments 1 t9610 DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 2 1 3 — 7 7 — 0 0 0 2 0 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch 66 Test hole locations Ib Drainfield orientation and layout Reference depth from original grade: Rj Soil logs 66 Trench bed dimensions and Ed Septic tank 56 Property lines critical distances within layout 19 Drainfield cover 0 Existing and proposed wells 19 D-Box/Valve box locations Reference depth from original grade within 100 ft of property Rf Septic tank/pump chamber and restrictive strata: ❑ Measurements to cuts,banks,and locations It Laterals,trench/bed,top and surface water and critical areas 19 Observation port location bottom ❑ Location and orientation of IZ Clean-out location ❑ Curtain drain collector curtain drain and all absorption R1 Manifold placement ❑ Send augmentation components 19 Orifice placement Other cross-section detail: R1 Location and dimension of Rf Lateral placement with distance Rf Observation ports/clean-outs primary system and reserve area to edge of bed Other Information A Buildings Ef Audible/vis a referenced Yes No 66 Direction of slope indicator Rf Scale of d wn on scale Waterlines a I$ ❑Design staked out bar ❑ 51 Recorded Notices attached A Roads,easements,driveways, ❑ gf Waiver(s)attached parking fits ❑Pump curve attached S5 North arrow and scale drawing (. ❑ 51 Evaluation of failure shown on scale bar -!T 51 .aaa PAULA JOY JOHNSON Non-residential justification '. �Ectl\ W ❑ Rf Waste strength nxA 1 ❑ lif Flow DESIGN APPROVAL The undersigned designer must be red by installer at time of installation 56 Yes ❑ No Signature of Designer Date AA The undersigned has reviewed this design on behalf of Mason County Public Health and determined it tt.k compliance with state and local on-site I tions: 1 L °"SOON , Envir runtal Health Specialist Data ryF,y� 1ply 4 .6 N CAUTION: N: DESIGN APPROVAL IS S VALID ONLY PU�NID UNDER FOLLOWING CONDA�N*44' `yF design ped"Approved" Mason Co ' The Onsite Sewage Permit has not expired,the Permit Expiration Date is: Z 6/ 70 Z 7 Dminfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be canned and available for public view on the Mason County Web site. Updated Date: 12/72015 xsxaa _ ^^••• § Y MUM b YY�� g T 6S off' 88 e.e8$R $.i8 aW EI Ra: 8t'k �vls - , a �4F4F8p4 • • 64 alit ARM ek 14 I ACAP Mm .9KK�Wa a \ b. A Eqa, o a o a ti s Y 9rn i � m � '< Gy Off �o g � n � cAj r m^y hog R - m $Eq a9� '0�` xl2 PE p -11,11 ag $ 5 f R 3`� . Z i D C5)3'X40` P? MAtD.F. � �RF atEsQa ' oc. W ITt+ R£SEQ l rJ 8E •EEN % 00, J LO b0 90 � VLb-r PLA s rAkt lt� PI'CD N1B tdD 211 E .N,R,4S,N RID(£ DR ywt° � \ oR SELFP�AlWp 4®528 /y'�ESS 6F0 LF 1 D-24",�l 4 Y.ois [' cevec6o I P�.yi �2: D-Zq "gs) ++e cts PAT W -!}(M 4--; t I T ko ma ., a � PRePed ED ��,/ �a� "• `�iri G3: 0-28 551 troa"f5 'S BR 11 O S10 341 ® cut�i°nJOra 24-32" t593i'+till I GA4%E I � Kew. Ol Audio-Visual Alarm 100 , n "gyomF I O2 Cleanout 1`J } I¢ (+ 500 Gallon Pre-Trash tank �to tayKs l W T O4 NUWazer BNR-500 ATiJ Tank � OC 0. OS 1,000 Gallon Pump Chamber O6 Valve Control Box pI1 ( I �. R V r � F °� 0*CO&M,FNu/�12�4 O \ RO � (aC ''ROAD OJQ N�FNTA(HFAlTN \ EASE Nt ANT 2e TCA'n15PD'�T UNfi l� 40' Valve Control flax w6h 125 Ball vdWe }3r I 9 0 1.25 FeePPr Lh1ee Typical CbanM C Ir 1 25' Lot-.' Typcal Obaervo tan Port 30 0 60 PPRbVED masa OCT 0I 2024 o NCOUNIYEDJR084"rkHEgLrH -(yP1cnL Detailed Drainfield __you aOSto.gAT1oa P.1 Gale o' 10' zo °m ¢' Filter Froric Cevei i Flu d C5) 40' 1 .25" Sched. 40 _aterals 314 to 2" 2-112 125' Lateral 1t C8) 3/ 16" Orifices C' 60" O.C. °rat No k 6' Per Lateral. 1 st & Last Orifice 30" From End of Trench screw-on Ccp 1Zt} 45 peR,e Efaow of erd flnirlcMv Layer EM of gtcn -- Drainfield Cross-Section Vie woo - a.a °a1 Net To scant wt.: Gl t to be irem 0 le 6 Ma. bbw Note: o • Ctf, r PW Port oP w Flail Gage. Nar4 Prole Mth Reba. Clem OW TO Be 9 PVC POP f,. Bottom of Trench RPOwPa at tM Entl of Each Lateral. To F'eiPheB Grant. RPm"ONe Cap "it be InetalfeE an obwrvafim Port POe. ArcW ,; ,a 149 Arrow Septic Designs On Bottom with GW &B JO Tee. PAOLA JOY NMSON''. ,.,Z,O of 5 TOW Regtlr,d h S,.'.m 1 t �` (3 6 0) 8 9 8-2 2 5 5 Length Length Orifice # Distance from Distance from Lateral# (in.) Ft. Spacing Orifices Feeder Line(in.l Cleanout In. 1 480 40 60 8 30 30 2 480 40 60 8 30 30 3 480 40 60 8 30 30 4 480 40 60 8 30 30 « pp 5 480 40 So 8 30 30 Total Lateral Length �® 200 Total#Orifices 40 GPM= 23.6 'HAS orl �® Dynamic Head Calculations oNCOUNry��0/y E�1 y Selected residual pressure: 2 ft' q h1 A�yE4(jy Length (Ft.) #Orifices Transport Pipe 140 40 1.40 ft. Feeder Total Lateral Line Length Lateral#1 40 2 42 8 0.15 ft. Lateral#2 40 11 51 8 0.19 ft. Lateral#3 40 20 60 8 0.22 ft. Lateral#4 40 29 69 8 0.25 ft. Lateral#5 40 38 78 8 0.28 ft. Total Elevation Lift 15.00 IL Total Dynamic Head 19.49 ft SECURED LIO WITH GAS TIGHT SEAL THREADED UN16l u.DIAMETER ACCESS RISER t SERVICE VALVE. FllaISFI GRADE _— -- r_�Tp oRAWPrELD FlIOTANK TAlalr ri ENERDENCY 8TORADE Alan SIPHON VALVE' HUM WATER ALiOW LEM — MODAL LEM WORKING VOLUME PLOAFTEM FLOAT MOUNT OO ENCLOSED PDYP E VALVE _SEDIMENT SD' — v �. BEDIYENTa_ ".f(llif r auro s PPUTA JOYY JONNSON h PUMP chmacB "fC'16E `if NEYt" LTYPIOALI A8 NEEDED Septic Tanks must meet standards required by WAC chapter 246-272C and FIGURE 2 manufacturer must be on Dept of Health list of registered sewa g a tanks- WA rxw ftMilo don 0337-022 -Page 35 of65 7 551�fo BrolOe wnstruction available 1139 series) „ High head version available(145 series) Double shaft seal versions available for added protection on Flow-Mate FOrmorci e nfvmlationis bsea Technical Darn Sheets FM2282,FM2783. In high head dewatering of effluent applications where pumping j performance is critical, this robust qfamilyofpumpsisknownforreliabilttS6 durability and performance. These pumps are especially suited for harsh environments,ZoetWscoDtnm design and corrosion-resistant powder coated epoxy finish add up to a long-lastingtroubLe-free productAPPI.ICATIONS: STEP or onsite applications �tl • Waterminsfer Light commerdaL dewatering SPECIFICATIONS: E • 1-1/2•NPT discharge �F • 1/1 HP NrougM1SHP MpOE IN THE USA Available in automatic or nonautomatic 696INaFmputmrllll • Model 137.139.140:1/2.(12 mm)spherical solids capacity wkh vortex impeller Model 145:3/P(19 ram)sphencM solids capacity with vortex impeller �f ' 'n.;..c..... PUMP PERFOR CURVE MODEL 5 152f Dose-Mate o R ENIVA"t M* N This is our fastest growing line of effluent ° u ' pumps.The 150 series is truly a workhorse designed for reliability under extreme 12 N conditions in an effluent environment ee 150 series pump curves cover a wide range w 'P of applications. They are well suited to as applications with lowpressure pipe(LPP) a I6l and enhanced flow STEP systems.Zoeller's N cool run design and corrosion-resistant e x powder coated epoxy finish, in addition to the hermeticaLLy seated, oil-filled motor 16 and non-cLoggingvortex impeller add up to a Long-lasting trouble-free product _ 10 pPPIlCpT10N9: • STEPoromiteappLications ° kM Y.WMI p N `II 1° 6 is1°0 • Light cammerciaL dewatering oauaxs m .e too .ro 16 SPECIFIGATIONS: ya A 4M RPMIN iE • 1-1/2"NPi discharge /\ • 3/10 HP through 1/2 HP Available in nonautomatic or with a variable Level O piggyback mechanical switch • 1/2-(12 mm)sphencaL solids capadty with vortex *4S, QCTOp FO thermoplukdOmpeller N / For more lnfomartlon,see Technical Data Sheat FM2784. COUNry 2Q0� ®All rights reserved. ZOELLER PUMP CO. 1502-TT8.2T311800A28-TBtl7/,fA9?Iterpumps.wm 9 �✓q MFNTq�HEgCTH _1 iSvs3rod'/MM3aM SIN :3'MJS S39G'G� O9fI Xtl�889G-tS9 N,aCi -8 O d e .N.a.p v098G YM'pNf1Otl�3lLLVfr GBEfC XOS' tl ysel1005 .s° •014I `JNI1:133NIJN3 543 4 FFI 7` e� 3y % aye k - ��35� P F Y tl C$$ 1g gt k Z '- • � 28 ����Eg i { i'{�Q odg• S Y a P I jkae3 s AP ROVED OCT 072024 I4I} a aK� r = <M A4O N OUNTYENpVFIgR P@ �YONMENTALHEAITr n¢ @ ?3 AzsE ^ 1; sA ' f k j $ acc gge3 5'3n:}d5. `9$, §Y83iis 8zs§dy3 '� HIM Una HIP a-r pOALPORTAEMTOR� WAl£R11aM LIDVdfl99) ' aIBER4IfYP) 1'PIC(1TP) 12'NE 161AgTIC r OpUPUNG a, a R®Ut£R rTEE t'PVC SWOGE I i II RETUR4 LINE I it i rrvc !,, I TRASH CHAMBER DIBEBTER CRA 21 WR OPERATHG fMACffV.61)G/iLLONB i OPERAPNO LAPACRY:<YI GNLCNS C{MMBBR ROOD G/JACRY:N]GALLCNB iL00DC/MACrtY^:.B.G\ 045 1 1B1 GAL.�I x TIM ' T 1r OIFFl15ER 9aRBR1 � P10A51-TOTMNWALL {• �` 6LUDGE RETURN r 1s TA➢ER PRWypEyIMR STONE-FREE NATIVE SOIL ORCOLIPAC I)SIND OVER STONY Still- 1)EsCavate lank hole vigh ve soal WMIs lo 1 font Wrgwins" tank W all bklea. 2)U bOud.of hole is ,W,install 3'of mmpaot eend S level Wt With atraed. :- 3)Install tank in center of hole,keeping 1 fi.voitl space on R9"*r' 2rSLOWERall sides.4)As tank is filling v Waief.fill in voitl apace vMh wined TOPCPL granular(sandy)soil free of large dumps Of day. 5)inTa11 rest of system,6 affix risrs to adapters vhthvra6)Perfoim Wtertightness test infield as regulredby lawl)unsdidian. II Ri3ER])Upon approvl lO paWfll,oaretullY backfiil ' ME=soils over top of Wok.8)Final glade the surtecebevoid pNanelkngwrfau —L-- -----mac--� Wamrtoviard tank. OLA Mg30NO0,1 0 10p4 AER� °I� ATMENT TANK DETAIL FOR NuWATER R-500 TREATMENT UNIT ENVIRO-FLO, INC. O- 3101112 Wastewater Tnebnanf Teehndogies P O.BOX 321161,Flo"ood,,INS 39232 scams: (877)836.8476 (601)845J715 fox 1" = 1.4 ft. . nvilo-Ro. g1s�IG Nu Walter �AA I \ 'f%0*00 0' FCj %LOIIN 0 PARTS LIST NuWater NR Assembly Diagram j A DUALA PORT TOR M.POLY DIFFUSER BAR a, B.Wr RUBBER W-W CuMPS t2) N.v PVC(3 IrY SECTION) C.Yr5ARBEDA➢APTO NPT(2! O.I"SUP LAP p.tl!'SUPX V2'NPTADAPTOPipR P. tR'CLF.AR PVC NOSE(OPTIONAL 5; E I-STREET.l! NPT BUSMN6 M O vY'PVC P;PE I.Y�N6lNtEw1 G '?W ELEOW(3) R,V PVC PIPE OW INSTALLER) (\ G,t'%t'X 1I TEE S.T PVC PIPE( . INSTALLER) 4.t'so-ELBWJ(3) T.vY MRSED ADAPTOR TO I"NPT I ;.P%P B4911NG L.VS STREET%VT NPT RUSHING R) J T'SANITARYTEE V IIT PVC COUPLER M K.I'PW CROW W T COUPLER(BY INSTALJER) L.P COUPLER(BY IN ALLER) ' Revised 2/25/12 q •&i D C ,uw Septic Dolyw, 9nc. o. NuWater BNR Pretreatment INSTALLATION &MAINTENANCE Pressure Distribution Systems 'PAUL Y ammson 1. Install Laterals with contour of the ground. 2, Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be[narked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the PUMP chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue),after pressure test and Environmental Health Dept. approval,turn orifices down(6 o'clock) and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10.Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 11. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area. 15. Inspect floats,clean filters,and test high water level alarm every 6-12 months as needed. 16. All materials and workmanship most meet County and State regulations. 17.Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19. All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning. Ensure anti-siphon hole sprays down/away from tank opening. 20. All transport lines under driveways or parking areas must be encased to prevent crushing. 21.Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation&Maintenance on your NuWater pretreatment system. APPROVED OCT 0 7 2024 'O V IE�J t '4.Y ENVIRONMENTAL HEALTH DJA