Loading...
HomeMy WebLinkAboutBLD2011-00577 Final Heat Pump - BLD Permit / Conditions - 1/27/2012 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Ir Shelton, WA 98584 flo MECHANICAL PERMIT BLD2011-00577 OWNER: TONY, HUBERT RECEIVED: 7/13/2011 CONTRACTOR: HOOD CANAL HEATING & COOLING (360)275-4992 LICENSE: HOODCHCO05DB EXP: 3/ ISSUED: 7/13/2011 SITE ADDRESS: 1 �Q NE�,FAIR MANOR DR BELFAIR EXPIRES: 1/13/2012 PARCEL NUMBER: �t0p4 LEGAL DESCRIPTION: S1/2 N1/2 SE NW LOT: 4 OF SP#2319 SURVEY 34/67 PROJECT DESCRIPTION: DIRECTIONS TO SITE: HEATPUMP General Information Setback Information Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft. Type of Work: MEC Fire Dist.: 2 Rear: Ft. Slope: Ft. Side 1: Ft. Valuation: Side 2: Ft. Mechanical Fixtures FEES • Type Qty. Type By Date Amount Receipt Heat Pump 1 Mechanical Permit Fee GMM 7/13/2011 $36.50 S120110000( Furnace<100K 1 Mechanical Base Fee GMM 7/13/2011 $28.50 S120110000( Total $65.00 BLD2011-00577 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FOR BLD2011-00577 CONDITIONS FOR BLD2011-00577 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800 IMZ—'— 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner nt is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. 3) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMYVJ TANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X jl(J� 4) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate" and are available in Y<or%sheets. The Mason County Permit Center will also have some available. X W—,7 5) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rev F X I/� BLD2011-00577 Please refer to the following pages for conditions of this permit. Page 2 of 4 6) Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and IMC. Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA)and be so labeled. (WSEC503.4) or in accordance to WSEC Section 1411. ,^ X 1'V Z1 7) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect �e made prior to requesting additional inspections. X 8) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason mc_-- rdinances and building regulations. X 9) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X J1'Z — BLD2011-00577 Please refer to the following pages for conditions of this permit. Page 3 of 4 10) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these struc tures meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: BLD2011-00577 Please refer to the following pages for conditions of this permit. Page 4 of 4 W o CONCRETE Gas Piping MANUFACTURED HOME C o Interior-Date By W Footings/Setbacks Exterror_Date By Ribbons m 0 Date By INSULATION Date By 4 Foundation Walls Set-up —i 8G/SLAB INSULATION Set-up Date BY Y Date B Date BY Z FRAMING Floors FIRE DEPARTMENT Date BY Date By Date By Walls PLUMBING Date By DECKS Date By Groundwork Vault TANKS Date Date BY Attic BY Date By D.W.V Date B, OTHER Date By DRYWALL Type. Date By Water Line Date By Type: v Date By Int.Brace Wall Date B — y r CD MECHANICAL �i�sep�at�«�ate By FINAL INSPECTION o Date By Date BY Date I LZ7 /Z BY a O Pass or Request Inspect. CD Type of Insp. Fail Date Date Done By Comments v a a o' _ N O tn CD 3 01 (D 0 PERMIT NO. MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670•Belfair(360)275-4467• Elma(360)482-5269 On the web www.co.mason.wa.us APPLICANT INFO MATION CONTRACTOR I R TION Owner r Company Name Mailing A es I r" _� yr Maili A ress J i J City State ld-_Zip Coded — City W yr —State Zip Code i,S.3sr Phone�lo� ' ���'Other Ph.2UO `.1a5 J7`Ik Phone - Other Ph. Lien/Title Holder Contractor Reg # xp. _ E mail address E Mail Address < < '� Gaj •tU:�tl'1 Drivers Lic.# DOB Drivers Lic. # DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No `1 '` c� Fire istrict Legal Description '1 t 1*1 O 0 A � ��9- t Site Address(Please include street name,street number and pity) I ja k Y hNnu r rI V"e t r Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG__Natural Gas—Heat Pump Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps X — Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X Date: 7— -3—1 caner/Owners Representativ ntractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group T e Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Ins ection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES