HomeMy WebLinkAboutBLD0125 Final SFR - BLD Permit / Conditions - 9/21/1989 TYPE RESIDENCE
Permit No. 0125 No. Floors 1 Sq Ftg 1512
Owner BOB SOLTIS INC. Tel275-4477 Date 6-13-89
Address P 0 Box 767 Belfair Zip
Contractor Self
( Address Zip
Legal Description Tr 2-C Survey of U S/P l -
Direction to project site 29-23-1
Northsfiore Rd rt. on Sand HillRd. , rt on Allison Lane rt
on Alderwood P1 . fi
uri ing xx Mechanical Sewer Wood Stove
Fireplace Deck Garage Carport
Basement Loft Other -�
3 bdrm �. —
Shorelines: 1/,4 Plumbing:
Setback: Mechanical
Special Interior:
Conditions: FINAL:o,,-q �/ 8q
Mobile e:
Smoke Detector:
Remarks
noting: �c �
Setback:
Foundation
Walls: V
Framing: SF-y F
Fireplace:
Wood Stove:
i
BUILDING PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
426-5593 DATE ISSUED
PERMIT NO.
ME � MAILADDRESS CITY&STATE ZIP PHONE
OWNERS sv �T/ 1 ; 62 '
DIRECTIONS L
TO JOB SITE X te__s' nj
anl ���
PARCEL c� c� LEGAL
NUMBER / .37 / �7s"/���j DESCR.
CONTRACTOR NAME MAILADDRESS CITY nTATE LICENSE NO. ZIlp PHONE
USE OF r
BUILDING
CLASSOF NEW ADDITION ALTERATION REPAIR MOVE REMOVE
WORK
DESCRIBE
WORK
BEDROOMS DECKS � � CARPORT_ NOTICE
SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR
BATHROOMS TOTAL SQ.FT. GARAGE �' CONDITIONING.
NO.OF STORIES BASEMENT ° ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT
COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR
TOTAL SO.FT. FIREPLACES DETACHED_ ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.
PERMANENT V24 SHORELINE
SEASONAL ;fir✓
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF
REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE
REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN
IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING
OBTAINING APPROVAL FRLTH . LDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT.
'.
X OWNER DATE 4� X BY DATE
FOR OFFICE USE ONLY
APPROVED APPROVED BUILDING VALUATION
DEPARTMENT DEPARTMENT `` CC
YES NO YES NO
HEALTH K PUBLIC WORKS FEE
PLANNING FIRE BUILDING PERMIT '7
D.O.T. BUILDING i PLAN CHECK
SPECIAL CONDITIONS BUILDING GROUP PRE.INSPECTION
SHORELINE
WOODSTOVE
PLUMBING C' L
MECHANICAL
STATE BUILDING FEE
STATESURCHARGE
APPLICAT N ACCEPTED BY PLANS Y APPROVED FOR ISSUANCE PERMIT VALIDATION '
/L ll� � BY ( CASH CK MO TOTAL `��
PLUMBING & MECHANICAL PERMIT APPLICATION
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
P.O. BOX 186 SHELTON, WASHINGTON 98584
427-9670 DATE ISSUED
PERMIT NO.
OWNER NA E � MAILADDRESS CITY&STATE ZIP PHONE
DIRECTIONS L
TO JOB SITE Z- r 7 �"� 4411, "s
LEGAL A
DESCR.
CONTRACTOR N ,� MAILADDRESS CITY SSTATE LICENSE NO. ZIP PHONE
USE OF
BUILDING ?
PLUMBING FIXTURES MECHANICAL FIXTURES
NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE
WATER CLOSETS n U FORCED-AIR/GRAVITY TYPE FURNACE 6.00
BASINS n FLOOR/SUSPENDED FURNACE 6.00
BATH TUBS BOILER/COMPRESSOR 6.00
SHOWERS REPAIR/ALTERATION 6.00
WATER HEATERS .e2 REFRIGERATION COMPRESSOR SYSTEM 6.00
AUTO.WASHER AIR HANDLING UNITS 7.50
SINKS HEAT-PUMPS 6.00
FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET
DRINKING FOUNTAINS VENT,FAN SYS.3.00 PER UNIT
LAUNDRY TRAYS WOOD STOVES 5.00
CONNECT TO CITY SEWER WOOD FURNACE 5.00
DISHWASHER
DISPOSAL
URINALS
PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00
TOTAL TOTAL
SPECIAL CONDITIONS: _ NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS
SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED.
OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED
THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE
COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL
WORK DONE WILL BE IN CO RMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE
WITHOUT FIRST OBT ING P OV FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT.
X OWNER DATE X BY DATE
FOR OFFICE USE ONLY
APPLICATION ACCEPTED BY PLANS CHECK BY BUILDING GROUP APPROVED FOR ISSUANCE PERMIT VALIDATION
IBY CASH CK MO
PLOT PLAN
ADDRESS �� /t ��/ry���•� � �� PERMIT NO. o
LEGAL
DESCRIPTION LOT ((fj BLK ADDITION �� w
SITE AREA Sq. Ft. AREA OF SITE OCCUPIED BY BUILDINGS ago Sq. Ft.
/. INSTRUCTIONS TO APPLICANT171)
J
THIS F NEED NOT BE USED WHEN PLOT PLANS DRAWN TO SCALE OF NOT LESS THAN 1"-20' AREA
FILED WITH PERMIT APPLICATION. (EACH BUILDING SITE MUST HAVE A SEPARATE PLOT PLAN.) \
FOR NEW BUILDINGS PROVIDE THE FOLLOWING INFORMATION IN THE SPACE BELOW: LOCATION OF
PROPOSED CONSTRUCTION AND EXISTING IMPROVEMENTS.SHOW BUILDING,SITE,AND SETBACK DIMEN-
SIONS. SHOW EASEMENTS, FINISH CONTOURS OR DRAINAGE, FIRST FLOOR ELEVATION, STREET ELEVA-
TION AND SEWER SERVICE ELEVATION. SHOW LOCATION OF WATER, SEWER, GAS AND ELECTRICAL
SERVICE LINES.SHOW LOCATION OF SURVEY PINS.SPECIFY THE USE OF EACH BUILDING AND MAJOR POR-
TION THEREOF.
INDICATE NORTH IN CIRCLE GRAPH SQUARES ARE 5' X 5' O 1"=20'
14
r,
I/We certify that the proposed construction will conform to the dimensions and uses shown above and that no changes will be made without !?
irst obtaining approval. =2/
I ------
NAME(a) OF OWNER(S1 OF SITE A STRUCTURE(!) (PRINT) SIGNATURE OF OWNER(S) OR AUTHORIZED REPRESENTATIVE
DO NOT WRITE BELOW THIS LINE
APPROVED
DISTRICT AS NOTED DATE
|
�
|
�
�
� PREPARED BY: FOSTER AND WILLIAMS ASSOCIATES, P. S. , ARCHITECTS
|
ANALYST: J. Goebel
|
� PROJECT: Soltis Residence
� PROJECT NO. : 8902
|
DATE: 6/5/89
�
� INTENT: Washington State Energy Code Conformance.
�
�
� NOTE: THIS BUILDING WAS NOT DESIGNED BY FOSTER AND WILLIAMS ASSOCIATES.
� THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR STRUCTURAL
�
INTEGRITY, NOR CODE COMPLIANCE BEYOND THIS ENERGY EVALUATION.
�
�
�
SYSTEMS INCLUDED IN THIS PROJECT
| FLOOR 1 (480 S.F. ) 2x1OJSTS. ,R-19 INS. , 5/8 CDX, 1/2 P.B. , VINYL
|
FLOOR 2 (1032 S.F. ) 2x1OJSTS R-19 INS 5/8 CDX 1/2 P.D. , CARPET
| ^ ' ^ ' '
| FLOOR 3 (O S.F. )
�
�
� ROOF 1 (1512 S.F. ) 2x4 TRUSS,R-38 INS. ,5/8 G.W.B.
� ROOF 2 (0 S.F. )
� ROOF 3 (O S.F. )
�
�
� WALL 1 (1476 S.F. ) 2x6 STUDS,R-19 INS. ,5/8 T-111, 1/2 G.W.B.
WALL 2 (O S.F. )
WALL 3 (0 S.F. )
SKYLIGHT 1: (O S.F. )
| SKYLIGHT 2: (O S.F. )
� SKYLIGHT 3: (O S.F. )
�
�
� WINDOW 1: (227 S.F. ) U VALUE= 0.6
WINDOW 2: (O S.F. )
WINDOW 3: (O S.F. )
HEAT TYPE: ELECTRIC RESISTANCE
HEATING ZONE: 1
BUILDING TYPE: RESIDENTIAL
OUTSIDE WINTER DESIGN TEMPERATURE: 23
WINDOWS = 15.0% OF GROSS FLOOR AREA
THIS BUILDING CONFORMS TO CHAPTER 4 OF THE WASHINGTON STATE ENERGY CODE
�
'
���� �
� |
|
HEAT LOSS CALCULATION AND HEATING SYSTEM SIZE
Soltis Residence
=========================================================================
� COMPONENT AREA U VALUE DELTA T HEAT LOSS (Q=U A T)
-------------------------------------------------------------------------
FLOOR 1 CAVITY 432 0.045 47 909.3
FLOOR 1 FRAMING 48 0.067 47 151.5
FLOOR 2 CAVITY 929 0.041 47 1792.0
FLOOR 2 FRAMING 103 0.059 47 286.7
FLOOR 3 CAVITY O 0.000 47 0.0
FLOOR 3 FRAMING O 0.000 47 0.0
�
| ROOF 1 CAVITY 1421 0.025 47 1679.2
| �
ROOF 1 FRAMING 91 0.162 47 692.2 �
ROOF 2 CAVITY O 0.000 47 0.0 �
ROOF 2 FRAMING O 0.000 47 0.0 �
ROOF 3 CAVITY O 0.000 47 0.0 �
ROOF 3 FRAMING O 0.000 47 0.0
� WALL 1 CAVITY 1045 0.047 47 2329.2
�
WALL 1 FRAMING 184 0. 112 47 967.0
WALL 2 CAVITY O 0.000 47 0.0
WALL 2 FRAMING O 0.000 47 0.0
WALL 3 CAVITY O 0.000 47 0.0
WALL 3 FRAMING O 0.000 47 0.0
WINDOW 1 227 0.600 47 6401.4
WINDOW 2 O 0.600 47 0.1111
WINDOW 3 O 0.600 47 0.0
DOOR 1 20 0.480 47 451.2
| DOOR 2 O 0.480 47 0.0
�
DOOR 3 O 0.480 47 0.0
�
SKYLIGHT 1 O 0.600 47 0.0
� SKYLIGHT 2 O 0.600 47 0.0
� SKYLIGHT 3 O 0.600 47 0.0
INFILTRATION =1. 1xVxT 47 6902.0
( RATE =1.0 FOR DOORS AND 0.5 FOR WINDOWS)
SLAB AREA O @ 2 BTU/SF 47 0.0
SLAB EDGE O @ 11 BTU/SF 47 0.0
OTHER HEAT LOSS 47
OTHER HEAT LOSS 47
OTHER HEAT LOSS 47
OTHER HEAT LOSS 47
MISC. HEAT GAIN(PEOPLE,APPLIANCES,ETC. ) 47 0.0
OTHER HEAT GAIN 47
OTHER HEAT GAIN 47
OTHER HEAT GAIN 47
-------------------------------------------------------------------------
TOTAL HEAT LOSS 22561.6
=========================================================================
MAXIMUM HEATING SYSTEM SIZE @ 150%:
ELECTRIC RESISTANCE: 9.9 KW OTHER: 33842 BTUH
NOTES:
1. WINDOW CRACK ESTIMATED AT 1 L.F./S.F.
2. DOOR INFILTRATION @ 1 CFM/S.F.
�
|
========================================================================= |
|
|
RESIDENTIAL COMPONENT COMPARISON �
Soltis Residence
=========================================================================================
ALLOWED AREA GR.AREA U VALUE Ux ACTUAL AREA GR.AREA U VAL. Ux |
RATIO ALLOWED RATIO RATIO ACTUAL RATIO
----------------------------------------------- ------------------------------------- |
22 FLOOR 1 480 0. 107 0.055 0.006 22 FLOOR 480 0. 107 0.047 0.005 �
FLOOR 2 1032 0.229 0.055 0.013 FLOOR 1032 0.229 0.043 0.0,10
O rLuux o o 0.000 0.055 0.000 FLOOR o 0.000 o.oO o 0.000 �
----------------------------------------------- ------------------------------------- |
|
23 ROOF 1 1512 0.336 O O26 O OO9 23 ROOF 1512 O 336 O O33 0.011
^ ^ ^ ^ ^ |
ROOF 2 O 0.000 0.026 0.000 ROOF O 0.000 0.000 0.000
ROOF 3 O 0.000 0.026 0.000 ROOF O 0.000 0.000 0.000
----------------------------------------------- -------------------------------------
24 WALL 1 1476 0.328 0. 144 0.047 24 WALL 1476 0.328 0. 146 0.048
WALL 2 0 0.000 0. 144 0.000 WALL O 0.000 0.000 0.000
WALL 3 O 0.000 0. 144 0.000 WALL O 0.000 0.000 0.000
----------------------------------------------- -------------------------------------
25 TOTAL 4500 Ut ALLOWED 0.074 25 TOTAL 4500 Ut ACTUAL 0.074
=========================================================================================
THIS BUILDING CONFORMS TO CHAPTER 4 OF THE WASHINGTON STATE ENERGY CODE '
|
|
Uo CALCULATIONS FOR FLOORS
| Soltis Residence
� FLOOR 1 SYSTEM R VALUES R VALUES FLOOR 1 AREA AREA U Ux
� HEATING 5 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
� ----------------------------------------- --------------------------------------------
I AIR FILM OUTSIDE 0.92 0.92 13 GROSS FLR. 480 XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000
3 OUTER SHEATHING 0.00 0.00 15 OTHER O 0.00 0.00 0.000 |
4 FRAMING 11.56 XXXXX 16 OTHER O 0.00 0.00 0.000 '
5 CAVITY a) INSULATION XXXX 19.00 17 OTHER 0 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 480 XXXX XXXX XXXXX
7 INSIDE SURFACE 0.78 0.78 19 FRAMING 48 0. 10 0.07 0.007
8 AIR FILM INSIDE 0.92 0.92 20 CAVITY 432 0.90 0.04 0.040
� 9 OTHER a) 1/2 P.B. , 0.66 0.66 ------------------------------------------
�
1O b) VINYL 0.05 0 O5 21 Uo=TOTAL LINES 14 TO 2O O O47
� . . .
� 11 Rt=TOTAL LINES 1-10 14.89 22.33
12 U=1/R TOTAL 0.067 0.045
=========================================================================================
FLOOR 2 SYSTEM R VALUES R VALUES FLOOR 2 AREA AREA U Ux
HEATING 6 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
----------------------------------------- ------------------------------------------
1 AIR FILM OUTSIDE 0.92 0.92 13 GROSS FLR. 1032 XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 OTHER O 0.00 0.00 0.000
3 OUTER SHEATHING 0.00 0.00 15 OTHER O 0.00 0.00 0.000
4 FRAMING 11.56 XXXXX 16 OTHER O 0.00 0.00 0.000
5 CAVITY a) INSULATION XXXX 19.00 17 OTHER O 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 1032 XXXX XXXX XXXXX
7 INSIDE SURFACE 0.78 0.78 19 FRAMING 103 0. 10 0.06 0.006
8 AIR FILM INSIDE 0.92 0.92 20 CAVITY 929 0.90 0.04 0.037
9 OTHER a) 1/2 P.B. , 0.66 0.66 ------------------------------------------
10 b) CARPET 2.08 2.08 21 Uo=TOTAL LINES 14 TO 20 0.043
11 Rt=TOTAL LINES 1-10 16.92 24.36
12 U=1/R TOTAL 0.059 0.041
=========================================================================================
FLOOR 3 SYSTEM R VALUES R VALUES FLOOR 3 AREA AREA U Ux
HEATING O FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
----------------------------------------- ------------------------------------------
1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS FLR. O XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000
3 OUTER SHEATHING 0.00 0.00 15 OTHER O 0.00 0.00 0.000
4 FRAMING 0.00 XXXXX 16 OTHER O 0.00 0.00 0.000
5 CAVITY a) INSULATION XXXX 0.00 17 OTHER O 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. O XXXX XXXX XXXXX
7 INSIDE SURFACE 0.00 0.00 19 FRAMING O 0.00 0.00 0.000
8 AIR FILM INSIDE 0.00 0.00 20 CAVITY O 0.00 0.00 0.000
9 OTHER a) 0.00 0.00 ------------------------------------------
10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000
11 Rt=TOTAL LINES 1-10 0.00 0.00
12 U=1/R TOTAL 0.000 0.000
=========================================================================================
�
�
�
�
�
Uo CALCULATIONS FOR ROOF
Soltis Residence
=========================================================================================
ROOF 1 SYSTEM R VALUES R VALUES ROOF 1 AREA AREA U Ux
HEATING 1 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
----------------------------------------- ------------------------------------------
1 AIR FILM OUTSIDE 0.61 0.61 13 GROSS ROOF 1512 XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT 1 O 0.00 0.60 0.000
3 OUTER SHEATHING 0.00 0.00 15 SKYLIGHT 2 O 0.00 0.60 0.000
4 FRAMING 4.38 XXXXX 16 SCUPPER O 0.00 0.60 0.000
5 CAVITY a> INSULATION XXXX 38.00 17 OTHER O 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 1512 XXXX XXXX XXXXX
7 INSIDE SURFACE 0.56 0. 56 19 FRAMING 91 0.06 0. 16 0.010
8 AIR FILM INSIDE 0.61 0.61 20 CAVITY 1421 0.94 0.03 0.024
9 OTHER a> 0.00 0.00 ------------------------------------------
10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.033
11 Rt=TOTAL LINES 1-10 6. 16 39.78
12 U=1/R TOTAL 0. 162 0.025
=========================================================================================
ROOF 2 SYSTEM R VALUES R VALUES ROOF 2 AREA AREA U Ux |
�
HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO �
----------------------------------------- -------------------_---------------------- �
1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF O XXXX XXXX XXXXX �
2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* O 0.00 0.00 0.00 �
3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* O 0.00 0.00 0.00 �
4 FRAMING 0.00 XXXXX 16 OTHER O 0.00 0.00 0.000
5 CAVITY a> INSULATION XXXX 0.00 17 OTHER O 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF O XXXX XXXX XXXXX
7 INSIDE SURFACE 0.00 0.00 19 FRAMING O 0.00 0.00 0.000 �
8 AIR FILM INSIDE 0.00 0.00 20 CAVITY O 0.00 0.00 0.000 �
�
9 OTHER a) 0.00 O OO ------------------------------------------
. . �
10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 �
11 Rt=TOTAL LINES 1-10 0.00 0.00 �
�
12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN ROOF 1. �
�
ROOF 3 SYSTEM R VALUES R VALUES ROOF 3 AREA AREA U Ux
�
HEATING O FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
----------------------------------------- ------------------------------------------
1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF O XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* O 0.00 0.00 0.000
3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* O 0.00 0.00 0.000
4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000
5 CAVITY a) INSULATION XXXX 0.00 17 OTHER O 0.00 0.00 0.000 �
�
6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF O XXXX XXXX XXXXX
7 INSIDE SURFACE 0.00 0.00 19 FRAMING O 0. 00 0.00 0.000
8 AIR FILM INSIDE 0.00 0.00 20 CAVITY O 0.00 0.00 0.000
9 OTHER a) 0.00 0.00 ------------------------------------------
10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 |
11 Rt=TOTAL LINES 1-10 0.00 0.00
12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN ROOF 1.
=========================================================================================
Uo CALCULATIONS FOR WALLS
Soltis Residence
=========================================================================================
WALL 1 SYSTEM R VALUES R VALUES WALL 1 AREA AREA U Ux
| HEATING 1 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
/
� ----------------------------------------- -------------------------------------------
I AIR FILM OUTSIDE 0. 17 0. 17 13 GROSS WALL 1476 XXXX XXXX XXXXX
�
� 2 OUTER SURFACE 0.78 0.78 14 WINDOW 1 227 0. 15 0.60 0.092
� 3 OUTER SHEATHING 0.00 0.00 15 WINDOW 2 0 0.00 0.60 0.000
�
4 FRAMING 6.88 XXXXX 16 WINDOW 3 0 0.00 0.60 0.000
�
� 5 CAVITY a) INSULATION XXXX 19.00 17 DOOR 1 20 0.01 0.48 0.007
� 6 b)AIR SPACE XXXX 0.00 18 DOOR 2 O 0.00 0.48 0.000
�
7 INSIDE SURFACE 0.45 0.45 19 DOOR 3 O 0.00 0.48 0.000
�
| 8 AIR FILM INSIDE 0.68 0.68 20 OPAQUE WALL 1229 XXXX XXXX XXXXX
| 9 OTHER a) 0.00 0.00 21 FRAMING 184 0. 12 0. 11 0.014
|
10 b> 0.00 O O0 22 CAVITY 1O45 O 71 O O5 0 O34
| ^ ^ ^ ^ ^
| 11 Rt=TOTAL LINES 1-10 8.96 21.08 ------------------------------------------
12 U=1/R TOTAL ~O^ 112 0.047 Uo=TOTAL LINES 14 TO 20 0. 146
|
| =========================================================================================
| WALL 2 SYSTEM R VALUES R VALUES WALL 2 AREA AREA U Ux
� HEATING O FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
�
� ----------------------------------------- -------------------------------------------
I AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL O XXXX XXXX XXXXX
�
2 OUTER SURFACE 0.00 O OO 14 WINDOW* O O 0O O OO O OOO
� . . . . .
� 3 OUTER SHEATHING 0.00 0.00 15 DOOR* O 0.00 0.00 0.000
� 4 FRAMING 0.00 XXXXX 16 OTHER O 0.00 0.00 0.000
5 CAVITY a) INSULATION XXXX 0.00 17 OTHER O 0.00 0.00 0.000
6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL O XXXX XXXX XXXXX
7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000
8 AIR FILM INSIDE 0.00 0.00 20 CAVITY O 0.00 0.00 0.000
| 9 OTHER a) 0.00 0.00 ------------------------------------------
|
1O b> 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000
11 Rt=TOTAL LINES 1-10 0.00 0.00
12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN WALL 1.
=========================================================================================
WALL 3 SYSTEM R VALUES R VALUES WALL 3 AREA AREA U Ux
HEATING O FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO
----------------------------------------- ------------------------------------------
1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL O XXXX XXXX XXXXX
2 OUTER SURFACE 0.00 0.00 14 WINDOW* 0 0.00 0.00 0.000
| 3 OUTER SHEATHING 0.00 0.00 15 DOOR* O 0.00 0.00 0.000
�
4 FRAMING 0.00 XXXXX 16 OTHER O 0.00 0.00 0.000
� 5 CAVITY a) INSULATION XXXX 0.00 17 OTHER O 0.00 0.00 0.000
� 6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL O XXXX XXXX XXXXX
7 INSIDE SURFACE 0.00 0.00 19 FRAMING O 0.00 0.00 0.000
OOO 8 AIR FILM INSIDE O OO O OO 2O CAVITY O O OO O OO O
� . . . . .
9 OTHER a) 0.00 0.00 ------------------------------------------
10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000
� 11 Rt=TOTAL LINES 1-10 0.00 0.00
/ 12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN WALL 1.
=========================================================================================