HomeMy WebLinkAboutCOM2014-00076 Cancelled ReRoof - COM Permit / Conditions - 12/10/2014 r
Inspection Line(360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone:(360)427-9670,ext.352
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Shelton,WA 98584
i COMMERCIAL BUILDING PERMIT
COM2014-00076
OWNER: ALLEN'S BILLIARDS&MORE RECEIVED: 6/4/2014
CONTRACTOR: HANLEY CONSTRUCTION INC 360-876-0870 LICENSE: HANLEC1034DP EXP: 1/1 312 0 1 5 ISSUED: 6/10/2014
SITE ADDRESS: 23692 NE STATE ROUTE 3 BELFAIR EXPIRES: 12/10/2014
PARCEL NUMBER: 123294300210
LEGAL DESCRIPTION: TR 21 OF SW SE
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
RE-ROOF CLASS A MATERIAL
General Information Construction&Occupancy Information
No.of Units: Type of Constr.:
Type of Use: A Insp rea: No.of Bathrooms: Occ.Group:
Type of Work: RRF t.: 2 No.of Stories: Exit Design. Load:
Valuation: Building Height:
VO
Pre-Manufactured U on Square Foo ration
Make: ngth: Lot Size:
Model: Width: Building:
Year. Serial No.: Basement: Parking Spaces:
Setback Information S .reline&Planning Information
Front: Ft. Shoreline: Ft.
Rear. Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPAT Comp.Plan Desig.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road^ Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants' Fire Lanes?:
Please refer to the following pages for conditions of this permit Page 1 of 6
COM2014-00076
r
Plumbing Fixtures
Mechanical Fixtures FEES
T e Qty. Type Qty, Type By Date
Building State Fee w Amount Receipt
YP T rrdnniA uAn R79nldnn
Re-Roof Fee TW wennIA xi An`n c92nlann
Total $173.00 —
CASE NOTES FOR
COM2014-00076
CONDITIONS FOR
COM2014-00076
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries. Contractor Compliance
Division.There are potential risks n monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-09 rson signing this condition is either the homeowner,agent for-he owner or a registered contractor according to
WA state law. X
2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title
X 14.28.
2
3) Existing roo e k shall be insulated to a minimum of R-38 if:The roof is un-insulated or existing insulation is removed to the level of the sheathing,
OR All in. n the roof/c '' s previously installed exterior to the sheathing or non
-existEnt
X!
4) Single rafter joist roof replace insulated to a minimum of R-38 allowing for a minimum of one-inch continuous vented airspace above
the level of insulation.X
k!!! M/K
5) WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason
County is 85 MPH.
X
6) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and
the manufacturer's installation instructions.
Adrip edge shall be pro ided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5)
X
7) A Class"A"r shall be installed and verified by manufacturer specifications during the inspection of this project.
X
Page 2 of 6
COM2014-00076
r
8) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY
IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF R OCCUPANCY WOULD RESULT IN PERMIT
REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x
9) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean AirAgency(ORCAA).
It is unlawful for any person to cause or allow the demolition(or major renovation)of any structure.-in less all asbestos containing materials have
been identified and removed from the area to be demolished.Work shall not commence on an asbestos project or demolition project unless the
owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW,Olympia WA 98502, 360.586.1044/800.422.5623
www.orcaa.org
X
10) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE
ADOPTED BUILDING CODE.
The construct cn of the psrmittad project is subject tc inspections by the M..ason County Building Department. All constriction must he in
conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or altei ations required by a
Mason County Buildin In shall be made prior to requesting additional inspections.
x n�
Page 3 of 6
COM2014-00076
r
r �
11) Un-vented roof assemblies are approved provided installation conforms with the Washington State Amendment to the International Building Code,
Section 1203.2 and the International Residential Code, Section R806.4
In addition Mason County shall require proof that manufacturer specifications for the roofing material verifying that the manufacturer's warranty is
approved for an un-vented attic assembly. Minimum required R-Values shall be maintained as required by the applicable energy code.
If spray foam insulation is proposed Mason County shall require a site inspection, review of proposed material,and approval of the application prior
to installation. Provide manufacturer specifications and identify the certified installer for review and approval.
WSEC Section 502.1.6.3 Roof/Ceilings: Roof/ceiling assemblies where the ventilation space above the insulation is less than an average of 12
inches shall be provided with a vapor retarder. Faced batt insulation where used as a vapor retarder shall be face stapled. Single rafter joist vaulted
ceiling cavities shall be of sufficient depth to allow a minimum one-inch vented air space above the insulation.
EXCEPTION: Un-vented attic assemblies(spaces between the ceiling joists of the top story and the roof rafters)shall be permitted if all the
following conditions are met
..� t ed within I thermal e
The un-venteL attic spice is completely c^.^.3:r. the bui ding the, 1 rv�.ope.
2. No interior vapor retarders are installed on the ceiling side(attic floor)of the un-vented attic
assembly.
3. Where wood shingles or shakes are used,a minimum 1/4 inch(6 mm)vented air space
separates the shingles or shakes and the roofing underlayment above the structural sheathing.
4.Any air-impermeable insulation shall be a vapor retarder,or shall have a vapor retarder
coating or covering in direct contact with the underside of the insulation.
5. Either Items a, b or c shall be met, depending on the air permeability of the insulation directly
under the structural roof sheathing.
a.Air-impermeable Insulation only. Insulation shall be applied in direct contact to the underside
of the structural roof sheathing.
b.Air-permeable insulation only. In addition to the air-permeable insulation installed directly below the structural sheathing, R-10 rigid board or R-10
sheet insulation shall be installed directly above the structural roof sheathing for condensation control.
c.Air-impermeable and air-permeable insulation. Minimum R-10 air-impermeable insulation shall be applied in direct contact to the underside of
the structuraal Jrt?athing for condensation control.The air-permeable insulation shall be installed directly under the impermeable insulation.
X /�
12) Ali building permits shall have a final inspection performed and approved by the Mason County Budding Department prior to permit expiration.The
failure to request a fin inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-compliant ounty ordinances and building regulations.
X
Vi
13) All permits expire 180 days after permit issuance,or 180 days after the last inspection activity is performed. The Building Official may extend the
time for action for ri t exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control
of the permit h prevented action from being taken. No more than one extension may be granted.
X
COM2014-00076 Page 4 of 6
r
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed_ I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permittapplication becomes null&void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEAN OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATI O 180 D WILL INVALIDATE THE APPLICATION.
Z /
Signature Date
mg<A 4� OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate)
COM2014-00076 Page 5 of 6
I
zo
�f'pN Co�NT r �C
A MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
Mason County Bldg. III, 426 West Cedar Street
PO Box 279, Shelton, WA 98584
I www.co.mason.wa.us (360)427-9670 ext.352 Belfair(360)275-4467 Elma(360)482-5269
NON-RESIDENTIAL RE-ROOF APPLICATION
Roofing Sq ft area Type of Roofing to be Applied
Number of existing layers Roof Pitch: �� Tear off: '/Yes _No
Use of buildin t, Construction Type: RoofinL Classification
Occupancy classification) (wood,steel frame,masonry etc.) **See note below (A,B or Q
Include manufacture specifications verifying materials meet roofing classification.
- B&C roofing classifications require site plan drawn to scale.
Will insulation be installed? ves ✓No
Existing Insulation,describe :
Existing roofs shall be insulated to the requirements of R-38 if electric heat, R-30 all others, IF:
a.The roof is un-insulated or insulation is removed to the level of the sheathing or
b.All insulation in the rooflceiling was previously installed exterior to the sheathing or nonexistent.
Roof ventilation, describe :
Roof deck&insulation Inspection required before new roofing materiab can be appl
Name of Business:AI-V_ �l� S
Subject Property Address: • 'aO 12 . LIE <,4- 0-4- 3
Assessors parcel number(s)• 1� � i 00210
(Address and parcel number required for all applications)
Applican • 'I v�
Mailing address d & Ci�y y ( at ` V\/,k Zip:
Phone ( ) FAX ( ) E-Mail:
**Expedited permits may be obtained for class A roofing
Applicant: Date: I /
I hereby authorize M on County representative(s)to inspect my property Monday-Friday between the hours of 8 a.m. and 5
p.m.during this permit application process for purposes of verifying site conditions.
- e
s
CONSTRUCT/ON
��lp�J.- • ee
Email: sales@iroofit.com•Website: www.iroofit.com•Fax: 360-769-9688
General Contractor#: HANLEC-1034DP•PO Box 865,Port Orchard,WA 98366
Port Orchard 360-876-0870•Bainbridge Island 206-842-4321 a Gig Harbor 253-851-0113
This proposal is specifically prepared for:
Name: Hung Chau Date: 5/27/2014
Project: PRJ#5003:Allen's Billiards Roof Replacement 2014 Phone:
Street: 23692 NE SR 3 Cell: (360)550-8551
City: Belfair Zip: 98528 Email: chauhung(a,wavecable.com
We hereby submit this proposal for the following products and services:
Job Scoye•
1. Set up safety zones as necessary around building during roof replacement. (Cones,tape, barricades,etc.)
2. Remove existing 3 layers of built up roofing on flat roof. Haul all debris to an authorized waste collection facility.
$50/square added to total investment for any additional layers of roofing encountered.
3. Inspect and replace all defective and/or rotten sheeting with 1/2"CDX plywood @$55 per sheet. Any other
substructure,fascia and/or siding repair charged at$65 per man hour plus material costs.
4. On flat portion of roof install Versico 60 mil TPO according to manufacturer's specifications over 1/2" EPS fanfold
foam or rigid foam on main portion of roof. Versico 60 mil TPO comes with a 20 year manufacturer's warranty.
5. On upper flat section,eliminate the 2" internal scupper drains,and install Q-panel rigid iso foam taper so water runs
off upper section to lower section flat roof.
6. Install new 3" or 4" U flow drains on lower section of flat roof.
7. Install all new roof flashings,vents,and plumbing flashings. Any gas piping, HVAC ducting,and/or electrical
work is not included in bid price and if need be will be performed by others. Includes new parapet cap metal.
8. Clean jobsite of all roof related debris upon completion of project.
9. Perform onsite inspection of roof with building owner and Hanley Construction representative upon completion of
project.
The pricing for the above listed products and services are as follows:
Options:
1. 60 mii T rid Membrane -----------------------------S i 9,82 1.00
Family owned and operated since 1980. As usual, the Hanley Construction Lifetime Workmanship Guarantee applies.
Sales Tax not Included Acceptance of Proposal:
This quotation valid for thirty(30)days. Payment The above prices,specifications and conditions are
Terms:15%Non-Refundable deposit due upon satisfactory and hereby accepted. The signing of this
acceptance of proposal. Remaining balance due upon proposal authorizes Hanley Construction Inc to
completion of project. Any unpaid balance including any provide all materials and services as specified. In no Customer signature: t�l
applicable late fees and/or attorney fees incurred in event shall Hanley Construction be liable for
collection will bear interest at 181/e per annum until paid consequential or incidental damages,asbestos and/or
in full. Acquisition and cost of any and all permits is the lead paint abatement,and mold or algae growth of Mailing Address:
responsibility of Customer. Hanley Construction shall any type. Signing of this proposal acknowledges that
not be liable to recalibrate or remount any electrical customer has received,read and accepted the"Notice
devices on roof.(Satellite dishes,antennas,etc.) to Customer"statement.
Hanley Construction Inc: P a u 1 N e u i A
.b5
• R • •
VERSIWEL
r = ...
a
A _
7-L-
TPO ROOFING SYSTEMS
VERSICO A SINGLE SOURCE FOR SINGLE-PLY ROOFING
ROOFING SYSTEMS versico, PO Box 1289, Carlisle, PA 17013
Tel: 800.992.7663 Fax: 717.960.4036 Web: www.versico.com
• U R C E F •
VERSIWELO
VERSIWELD ROOFING SYSTEMS ENVIRONMENT
The VersiWeld`" Roofing Systems incorporate VersiWeld membranes are ideally suited when
45-mil, 60-mil or 80-mil (TPO) Thermoplastic environmental issues are of concern because the
Polyolefin membrane. membrane is produced without the use of any
chlorinated ingredients or plasticizers.VersiWeld
Versico's VersiWeld membrane is comprised of membranes are 100%recyclable.
three layers-a TPO polymer base; a strong, MEMBRANE FLEXIBILITY
polyester-reinforced fabric center(scrim)and a
tough thermoplastic polyolefin compounded top Membrane formulation contains no plasticizers or chlorine
ply. Because top ply is the most vital membrane so it will not dry out or become brittle with age.This sheeting
component for long-term weathering characteristics, easily accommodates the building's normal expansion and
Versico manufacturers its membranes with an industry contraction.
leading "thicker"and "smoother"top ply over scrim.
The smooth surface resists dirt pick-up and biological
growth compared to other thermoplastic membranes. CHEMICAL RESISTANCE
MEMBRANE BENEFITS VersiWeld membrane is highly chemical and contaminant
resistant. Most liquids and chemicals normally exhausted onto
XT
the roof have no effect on the membrane.
OCTMURRO FIRE RESISTANCE
WEATHERING PACKAGE VersiWeld roofing meets UL 790 requirements for external fire
Class A ratings and UL P assemblies for internal, hourly fire
Versico's VersiWeld membranes are enhanced with ratings.Consult the UL Building Material Directory for specific
Versico's OctaGuard XT" Weathering Package resulting assemblies.
in the most dependable, long-term performance
characteristics in the industry. WIND RESISTANCE
VersiWeld TPO membranes carry the ENERGY STAR" VersiWeld roofing has surpassed Factory Mutual's 1-90 wind
qualification having exceeded the stringent program resistance classification,one of the most stringent standards
guidelines based upon solar reflectance and heat in the industry,as listed in the FM Approval Guide.
emittance.Additionally, VersiWeld is listed as a CRRC
(Cool Roof Rating Council)certified product meeting
the Title 24 mandates for the state of California. INSTALLATION
Versico's ENERGY STAR-qualified VersiWeld membranes Heat-welded systems are easy to install since minimal labor
with their high reflectivity ratings help reduce the and few components are required.VersiWeld membrane
amount of energy required to maintain cool building welds at fast speeds— 10-to 15-feet per minute at moderate
environments. Less energy consumed results in less temperature settings.
pollutants generated back into the atmosphere
(lessening the Urban Heat Island Effect)and directly VERSICO TOTAL SYSTEM WARRANTIES
contributes to a cleaner, cooler environment.
5-year to 30-year No Dollar Limit Total System Warranty
coverage is available.
' L Y ' • •
TPO ROOFING SYSTEMS
ertified
Fabricated
Accessory
ACCESSORIES
The most critical and time consuming portion of
VersiWeld roofing Installation is made easier and faster
with VersiWeld Certified Fabricated Accessories.
VersiWeld accessories provide exceptional durability
and weatherability with the added benefit of being heat
weldable.VersiWeld TPO accessories greatly reduce job
time, in turn, reducing labor time.
All VerslWeld TPO accessories carry the Certified - -
Fabricated Accessory(CFA)seal of approval meaning
they adhere to the most stringent quality tolerances
required to be included in a Versico warranted
roof system.
VerslWeld Fully Adhered Roofing System
begins with insulation mechanically attached to the roof deck.The membrane and
substrate are then coated with VersiWeld bonding adhesive.The membrane
is rolled into place and seams are then hot-air welded.
TPO PS RUSS TPO T-Joint Covers
w
TPO Non-Reinforced Flashing PS Coverstrip ;
VersiWeld Mechanically Attached Roofing System
starts with insulation fastened to the substrate.VersiWeld membrane is then
fastened through the insulation with fasteners and plates.(Consult the Versico
{ „a_ Fastener Sell Sheet)Adjoining membrane sheets are overlapped and joined
together by hot-air welding.
TPO Molded Sealant Pockets TPO Split Pipe Seals
•Please see VersiWeld accessories literature for a more complete
listing of accessories.
' S I C • ' • •
VERSIWELO
VERSIWELD 45- & 60-MIL THICK REINFORCED TPO
Basic Properties and Characteristics (Standard and HS)
Physical Property ASTM D6878 Requirement 45-mil 60-mil 80-mil
Tolerance on nominal thickness, % +15,-10 t 10 t 10 t 10
ASTM D751 test method
Thickness over scrim,in.(mm) 0.012 min 0.018 typ 0.024 typ 0.034 typ
ASTM D6878 optical method, (0.305) (0,457) (0.610) (0.864)
average of 3 areas
Breaking srength, Ibf(kN) 220(976 N) 225(1.0)min 250(1.1)min 350(1.6)min
ASTM D761 grab method min 320(1.4)typ 360(1.6)typ 425(1.9)typ
Elongation break of reinforcement,% 15 min 15 min 15 min 15 min
ASTM D751 grab method 25 typ 25 typ 25 typ
Tearing strength,Ibf(N) 55(245)min 55(245)min 55(245)min 55(245)min
ASTM D751 proc. B 8 in.x 8 in. 130(578)typ 130(578)typ 130(578)typ
Brittleness point °F(°C) -40(-40)max -40(-40)max -40(-40)max -40(-40)max
ASTM D2137 -50(-46)typ -50(-46)typ -50(-46)typ
Linear dimensional change,% t l max t 1 max t 1 max t 1 max
ASTM D1204,6 hours at 158°F -0.2 typ -0.2 typ -0.2 typ
Ozone Resistance,no cracks 7X PASS PASS PASS PASS
ASTM D1149, 100 pphm, 168 hrs
Water absorption resistance, mass% t 3.0 max t 3.0 max t 3.0 max t 3.0 max
ASTM D471 top surface only 2.0 typ 2.0 typ 2.0 typ
166 hours at 1587 water
Factory seam strength, Ibf/in(kN/m) 66(290)min 66(290)min 66(290)min 66(290)min
ASTM D751 grab method
Field seam strength, Ibf/in(kN/m) No requirement 25(4.4)min 25(4.4)min 40(7.0)min
ASTM D1876 tested in peel 50(8.8)typ 60(10.5)typ 70(12.3)typ
Water vapor permeonce, Perms No requirement 0.10 max 0.10 max 0.10 max
ASTM E96 proc.B 0.05 typ 0.05 typ 0.05 typ
Puncture resistance,Ibf(kN) No requirement 250(1.1)min 300(1.3)min 400(1.8)min
FTM 101C,method 2031 325(1.4)typ 350(1.6)typ 450(2.0)typ
(see supplemental section)
Properties after heat aging
ASTM D573,670 hours @ 240°F
Breaking strength, %retained 90 min 90 min 90 min 90 min
Elongation reinf.,%retained 90 min 90 min 90 min 90 min
Tearing Strength, %retained 60 min 60 min 60 min 60 min
Weight change, % t 1.0 max t 1.0 max t 1.0 max t 1.0 max
Typical Weights 0.23 Ib/ft21(1.1 kg/m2) 0.29(1.4) 0.40(2.0)
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product This data and information is
intended as a guide and does not reflect the specification range for any particular property of this product 1u11
Radiative Properties for ENERGY STAR® Cool Roof Rating Council (CRRC) & LEED®
Physical Property Test Method White TPO Tan TPO Gray TPO
ENERGY STAR Initial solar reflectance Solar Spectrum Reflectometer 0.87 0.68 n/o
ENERGY STAR solar reflectance after 3 years Solar Spectrum Reflectometer 0.83 0.64 n/o
(after cleaning)
CCRC initial solar reflectance ASTM C 1549 0.79 0.71 0.46
CCRC solar reflectance after 3 years ASTM C 1549(uncleaned) 0.70 0.64 0.43
CCRC initial thermal emittance ASTM C 1371 0.90 0.86 0.90
CCRC thermal emittance after 3 years ASTM C 1371 (uncleaned) 0.86 0.87 0.88
LEED thermal emittance ASTM E 408 0.95 0.95 0.95
SRI(Solar Reflectance Index) ASTM E 1980 110 88 55