Loading...
HomeMy WebLinkAboutPAR2014-00045 - PAR Application - 6/24/2014 e. MASON COUNTY (360)427-9670 Shelton ext.352 DEPARTMENT OF COMMUNITY DEVELOPMENT (360) 275-4467 Belfair ext. 352 BUILDING•PLANNING•FIRE MARSHAL (360)482-5269 Elma ext. 352 Mason County Bldg. 111, 426 West Cedar Street IR54 Shelton, WA 98584 www.co.mason.wa.us August 14,2014 CERTIFIED MAIL Matthew K.Wyble 23150 NE SR 3 Belfair, WA 98528 31IJ 130MV ..r 22554 NE SR 3 3H1 NI 1r[?)4 -T 1 Belfair, WA 98528 Re: Cannabis Care Foundation, PAR2014-00045 Dear Mr. Wyble, I understand as a result of the pre-application conference on June 26, 2014 that there seems to be some confusion as to what county codes are applicable in this case. Cannabis Care Foundation is an access point or dispensary for medical cannabis that does not actually grow its own plants. As such, it was your position that this business does not meet the definition of collective garden and therefore is not subject to the codes that govern them in Mason County. I believe that more or less sums up your position. Please correct if I am wrong. Technically you are correct; Chapter 17.09 does not define access points or dispensaries. This is because they were removed from the original legislation as signed by the Governor and eventually adopted into state law. Nevertheless, part of a collective garden is"delivering cannabis for medical use"'which is what Cannabis Care does—it is a delivery point for medical cannabis. Dispensaries or access points are not separately defined; however they are still part of a collective garden and still subject to our codes. No land use is exempt from County codes and must fall into the category that best describes its intent. If Cannabis Care as a supplier of marijuana is not a collective garden,then the alternative is that it is a retail 502 operation -which I'm guessing is not the case. Therefore,you are subject to Chapter 17.09 and are required to comply with it and all other applicable county Codes. We attempted to them the enclosed summary in July but had it returned due to an incorrect address. Considering there were questions outstanding with respect to applicable regulations,we held off and resending it until I could follow up with the answers you needed. This letter will serve as that response. Please address the items listed in the enclosed documents and submit your necessary applications as soon as possible. 1 MCC 17.09.001 r � If you are in the process of obtaining permits we can consider you as in working toward compliance. If we do not have active permits addressing the outstanding code compliance issues,we will need to post a notice of violation at the site and request that you cease and desist operations until compliance is reached. I am optimistic, however that that will not be necessary. If you need any assistance or have any questions with respect to what your permitting requirements, please contact our office at(360)427-9670 ext. 352 or visit us at 426 W. Cedar, Shelton,WA. If you have questions for me, I can be reached at(360)427-9670 ext. 286 or Barbara@co.mason.wa.us. See you soon. rel 1-4�1 Barbara . Adkins,AICP Director UNITED STATES POSTA� Y1GE L. "A VA �. `First131 "MqH ➢➢ ,r^^^�. s 8!fe@,s f 4 • Sender: Please print your name, address, and ZIP+4 in this box • Mason County Community DevelopmgECEIVE P. 0. Box 279 RECEIVED Shelton, WA 98584 APR 0 7 , APR O l 2014 426 W. CEbAK 426 W: CEDAR ST (SoK — I �IIIIIjkllll+IIIIIdihi)lllihi -lih.lIHiI'H.i)Ili►1JI-I SECTIONSENDER: COMPLETE THIS SECTION COMPLETE THIS ON DELIVERY ■ Complete items 1,2,and 3.Also complete A. Signa item 4 if Restricted Delivery is desired. X ❑Agent ■ Print your name and address on the reverse Addressee so that we can return the card to you. B. Received y(Printed Name) C. Dat of D live ■ Attach this card to the back of the mailpiece, // I or on the front if space permits. D. Is delivery address different from item 1? Tes 1. Article Addressed to: If YES,enter delivery address below: ❑ No C n r,-e. �1 1 LT 3. Service Type Certified Mail ❑Express Mail ASS ❑ Registered ❑Return Receipt for Merchandise ❑ Insured Mail ❑C.O.D. ►"D r C' ,-1 C�-'� ��--►mot_� 4. Restricted Delivery?(Extra Fee) ❑Yes 2, Article Number 1— 7008 1,300 0001� 3607 4628 >..Z (Transfer from service label) t PS Form 3811, February 2004 Domestic Retum Receipt 102595-02-M-1540 UNITED STATES .SOWICE First-Class Mail Postage& Fees Paid USPS Permit No.G-10 • Sender: Please print your name, address, and ZIP+4 in this box • Mason COUNY Community DevelopmenffICEIVED P. O. Box 279 APR 17 2014 Shelton, WA 98584 426 W, CED.4R ST SENDER: COMPLETE THIS SECTION COMPLETE THIS SECTION ON DELIVERY ■ Complete items 1,2,and 3.Also complete A. Signature item 4 if Restricted DeliveryIs desired. � � V VN " ❑Agent ■ Print your name and address on the reverse X /'"'Y~ ti/ J �`� 54 Addressee so that we can return the card to you. B. Received by(Printed Name) C. Date of Delivery ■ Attach this card to the back of the mailpiece, or on the front if space permits. �� b1/ W �� _ f ''�D. Is delivery address different from item 1? ❑Yes 1. Article Addressed to: If YES,enter delivery address below: R No r-9— 3. Service Type Certified Mail ❑ Express Mail ❑ Registered ❑Return Receipt for Merchandise ❑ Insured Mail ❑C.O.D. 4. Restricted Delivery?(Extra Fee) ❑Yes 2. Article Number (Transfer from service label) 7008 1300 0001 3607 4680 PS Form 3811, February 2004 Domestic Return Receipt 102595-02-M-1540 MASON COUNTY (360)427-9670 Shelton ext.352 DEPARTMENT OF COMMUNITY DEVELOPMENT (360)275-4467 Belfair ext. 352 BUILDING•PLANNING•FIRE MAR5HAL (360)482-5269 Elma ext. 352 Mason County Bldg. III, 426 West Cedar Street PO Box 279, Shelton, WA 98584 www.co.masonma.us Date: RE: Pre-Submission Conference 4PARo?D/y - Dear Pre-Submission Conference Applicant, Please find enclosed a computer-generated report summarizing the highlights of your pre- submission conference on /y . If you have questions regarding the summary report,please don't hesitate to call the appropriate staff member. The various committee members,the departments they represent and their telephone extensions are listed below. Department Committee Member EXT Initials Fire Inspector Larry Waters 285 LAW Building Debbera Coker 510 DLC Health Dept. Cindy Waite 353 CEW Public Works Fred Perryman 625 FJP Planning Grace Miller 360 GBM Planning Rebecca Hersha 287 RDH Planning Michael MacSems 571 MMS Planning Allan Borden 365 AHB We appreciate you taking the time to meet with us. Once you have finalized your project and you are ready to submit your permit application, contact Debbera Coker at (360) 427- 9670 ext. 510 to schedule a time to review your plans for completeness. The comments are based on the project discussed during the pre-submission conference. Any changes or alterations to the original proposal may significantly change the permit requirements. In this case, a second pre-submission conference may be required to discuss the changes. Information provided to the prospective applicant during the pre-submission conference is based on County Regulations in effect at the time of the conference. Revised or new regulations could affect a future development application. A pre-submission conference does not vest a fixture development application. 7/9/2014 Case Activity Listing 2:20:36PM Case#: PAR2014-00045 i� Assigned Done Activity Description Date 1 Date 2 Date 3 Hold Disp To By Updated Updated 13y PAR1310 Planning Review 6/24/2014 None AHB 6/24/2014 GMM PARA10 Application Received 6/24/2014 None GMM 6/24/2014 DLC sewer and belfair water PARB20 Building Plan Review 6/24/2014 6/27/2014 None DONE DLC DLC 6/27/2014 DLC The document prepared as a result of the meeting is attached to this case. See notes in fire marshall activity line. PARB60 Fire Marshal Review 6/24/2014 6/27/2014 None DONE DLC DLC 6/27/2014 DLC The document distributed during the meeting is attached and includes requirements in accordance with ordinance 30-13,amendments to Title 17. During the meeting the representatives stated that they provide access and do not grow,therefore do not need to comply with the requirements adopted by Mason County related to collective gardens. Notified director of the discussion following the meeting so that she can clarify and notify applicants of compliance requirments. dlc Page I of I CaseActivity..rpt MASON COUNTY FIRE MARSHAL PRE-SUBMISSION CONFERENCE NOTES FIRE MARSHAL REPRESENTATIVE: Debbera Coker(360)427-9670 EXT 510, E-Mail: DLC@co.mason.wa.us Larry Waters (360) 427-9670 EXT 285, E-Mail: LAW(a-)_co.mason.wa.us DATE: June 25, 2014 PROJECT/ PROJECT TRACKING NUMBER : PAR2014-00045 PROJECT REPRESENTATIVE(S) or APPLICANT: Matthew Wyble, Cannabis Care Foundation PROJECT DESCRIPTION & SIZE: When an existing structure will be used to operate a Collective Garden in accordance with Mason County Code 17.09 the applicant may use the Change in Tenant application form to obtain a permit. Complete the application form following all instructions. Include required documents including a floor plan drawn to scale. In addition to items listed on the form be sure to identify all elements required for a Collective Garden as specified in 17.09.003, items A through M. When the permit application is submitted the permit will be routed to all relevant departments to verify compliance to department regulations. When all departments have approved the permit application the permit will be issued and required inspections performed. Occupancy approval will be granted after all required inspections are completed and approved. The following information is essential to perform a plan review by the Fire Marshal's office. Proposed construction plans and documents should include all relevant information listed below. Please note that the Fire Marshal representative has made every attempt to identify all critical information that will be needed based upon the information provided in the pre-application documents. Additional information may be necessary when the Fire Marshal is presented with proposed plans for the project. The information provided below references the current adopted codes. A complete list is provided at the end of this document. • OCCUPANCY CLASSIFICATION & USE : Identify the occupancy classification(s) and specify use as defined and specified in accordance to the current International Building Code (IBC), Chapter 3 and International Fire Code (IFC), Chapter 2. • CONSTRUCTION TYPE: Referencing IBC, Chapter 6 clearly identify the type of construction. • WATER SUPPLY & FIRE HYDRANT: Referencing IFC, Section 508; clearly identify intended code compliance, including type of water supply. • FIRE FLOW: A copy of the approved method for determining fire flow is enclosed. Please provide a copy of the completed worksheet with proposed construction documents. • EMERGENCY VEHICLE ACCESS: A copy of the "Standards for Fire Apparatus Access Roads" adopted through Mason County Building Code, Section 14.17 is attached. Verify that documents clearly identify code compliance. • ADDRESSING: Referencing IFC, Section 505 and Mason County Code Chapter 14.28, all new buildings shall have an approved address. Applications for an approved address can be obtained on the Mason County website at: www.co.mason.wa.us, Forms and Brochures, Community Development, the address to the referenced web page is: http://www,co.mason.wa.us/forms/Community_Devindex.php. Each building within the facility shall be distinguished with a separate identification so that emergency personnel can find the building in the event of an emergency. • EXITS: Verify that construction plans comply with IBC and IFC Chapter 10. Construction plans must clearly identify all exits, exit paths, length, signage information, etc. • AUTOMATIC FIRE ALARM: Referencing MCC17.09.003#I, the International Fire Code, and NFPA 72, provide information demonstrating compliance. Note that automatic fire alarm systems shall require a separate "Mason County Fire Protection System Permit Application". The application can be obtained by going to same website and page referenced above. • SPRINKLER SYSTEM: Referencing MCC 17.09.003#I, IFC and NFPA 13, provide information demonstrating compliance. Note that automatic fire sprinkler systems shall require a separate "Mason County Fire Protection System Permit Application". The application can be obtained by going to same website and page referenced above. • FIXED FIRE SUPPRESSION SYSTEM: Referencing IFC, provide information as needed on construction plans demonstrating compliance. Note that fire suppression systems shall require a separate "Mason County Fire Protection System Permit Application". The application can be obtained by going to same website and page referenced above. Standpipe systems, where required, need to be clearly identified on construction plans. • KNOX BOX: Referencing MCC 17.09.003#H and IFC access shall be required, typically through use of a knox box. Contact the local fire district to make arrangements for an approved key box, location, etc. The local fire district for your project is Fire District Number: NORTH MASON FIRE AUTHORITY and can be reached as follows: (360) 275-6711 • GAS METERS/TANKS: Referencing The International Fuel Gas Code (IFGC) and NFPA 58 provide compliance information as required within the referenced codes. • STORAGE (TYPE, HEIGHT, ETC.) Referencing IFC, Chapter 19 (Lumber yards and wood working facilities), Chapter 23 (High-piled combustible storage), Chapter 27 (Hazardous Materials), etc. o Identify all materials to be stored, including commodity classification (see IFC2303 and Table 2306.2), and type of plastics when applicable. Include anticipated quantities, loose or baled, anticipated height, o Identify hazardous materials classified as a physical or health hazard, include MSDS sheets as specified in IFC Section 2703.4. Referencing Table 2703.1.1(1), identify proposed control areas and method of protection. Referencing IFC Section 2704, identify spill control and proposed secondary containment, see also IFC Table 2704.2.2 o Identify method of storage (i.e. racks, shelves, pallets and what storage method is constructed of such as plastic, wood, metal, etc.) If pallets will be used , identify location of unused pallets and anticipated quantity o Identify flammable and combustible liquids, flammable gases, and flammable solids regulated under IFC Chapters 34, 35 and 36. Include information demonstrating compliance, including proposed storage, classification of flammable material and/or combustible liquid. • OTHER: REFERENCE CODE EDITIONS: Effective July 1, 2013 2012 INTERNATIONAL BUILDING CODE (IBC), INCLUDING APPENDIX CHAPTERS C, E; SECTION 101 THROUGH 106,AND H; EXCLUDING SECTION H106, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND EXCLUDING APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND'ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-50, INCLUDING AS APPENDIX M, 2006 INTERNATIONAL EXISTING BUILDING CODE. 2012 INTERNATIONAL RESIDENTIAL CODE FOR ONE-AND TWO-FAMILY DWELLINGS(IRC), Including Appendix Chapter G, as published by the International Code Council Excluding Part IV Energy, Part VII Plumbing, Part VIII Electrical and Appendix Chapters A, B, C, D, E, F, H, I, J, K, L, M, N, O, P, and Q; and adopting the Washington State Building Code WAC 51-51. 2012 INTERNATIONAL FIRE CODE, published by the International Code Council, excluding Appendix A, and adopting Appendices B, C, D, E, F, G and adopting the Washington State Building Code WAC 51-54. 2012 UNIFORM PLUMBING CODE (UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND MECHANICAL OFFICIALS(IAPMO)AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC 51-57. 2012 INTERNATIONAL MECHANICAL CODE (IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-52. 2012 INTERNATIONAL ENERGY CONSERVATION CODE( IECC),AS AMENDED BY WASHINGTON STATE BUILDING CODE WAC 51-11 EXHAUST SYSTEMS i SECTION 507 at an exhaust flow rate of 500 cfm (0.236 m3/s) in COMMERCIAL KITCHEN HOODS accordance with Section 17 of UL 710B 507.1 General. Commercial kitchen exhaust hoods shall 507.2.1.1 Operation. Type I hood systems shall be comply with the requirements of this section. Hoods shall be designed and installed to automatically activate the Type I or 11 and shall be designed to capture and confine exhaust fan whenever cooking operations occur. The cooking vapors and residues. Commercial kitchen exhaust activation of the exhaust fan shall occur through an hood systems shall operate during the cooking operation. interlock with the cooking appliances,by means of heat Exceptions: sensors or by means of other approved methods. A 1. Factory-built commercial exhaust hoods that are method of interlock between an exhaust hood system listed and labeled in accordance with UL 710, and and appliances equipped with standing pilot burners installed in accordance with Section 304.1 shall not shall not cause the pilot burners to be extinguished. A method of interlock between an exhaust hood system be required to comply with Sections 507.4, 507.5, 507.7,507.11,507.12,507.13,507.14,and 507.15. and cooking appliances shall not involve or dependupon any component of a fire extinguishing system. 2. Factory-built commercial cooking recirculating sys- 507.2.1.2 Exhaust flow rate label.Type I hoods shall tems that are listed and labeled in accordance with bear a label indicating the minimum exhaust flow rate UL 710B, and installed in accordance with Section in cfm per linear foot (1.55 Us per linear meter) of 304.1 shall not be required to comply with Sections hood that provides for capture and containment of the 507.4,507.5,507.7,507.11,507.12,507.13,507.14, exhaust effluent for the cooking appliances served by and 507.15. Spaces in which such systems are the hood,based on the cooking appliance duty classifi- located shall be considered to be kitchens and shall cations defined in this code. be ventilated in accordance with Table 403.3. For the purpose of determining the floor area required to 507.2.2 Type II hoods. Type II hoods shall be installed be ventilated, each individual appliance shall be above dishwashers and appliances that produce heat or considered as occupying not less than 100 square moisture and do not produce grease or smoke as a result of feet(9.3 m2). the cooking process, except where the heat and moisture 3. Net exhaust volumes for hoods shall be permitted to loads from such appliances are incorporated into the be reduced during part-load cooking conditions, HVAC system design or into the design of a separate where engineered or listed multispeed or variable- removal system.Type H hoods shall be installed above all speed controls automatically operate the exhaust appliances that produce products of combustion and do not system to maintain capture and removal of cooking produce grease or smoke as a result of the cooking pro- effluents as required by this section. Reduced vol- cess. Spaces containing cooking appliances that do not umes shall not be below that required to maintain require Type H hoods shall be provided with exhaust at a capture and removal of effluents from the idle cook- rate of 0.70 cfm per square foot (0.00033 m/s). For the ing appliances that are operating in a standby mode. purpose of determining the floor area required to be exhausted, each individual appliance that is not required 507.2 Where required. A Type I or Type H hood shall be to be installed under a Type Il hood shall be considered as installed at or above all commercial cooking appliances in occupying not less than 100 square feet (9.3 m2). Such accordance with Sections 507.2.1 and 507.2.2. Where any additional square footage shall be provided with exhaust at cooking appliance under a single hood requires a Type I a rate of 0.70 cfm per square foot[.00356 m3/(s•m2)]. hood,a Type I hood shall be installed.Where a Type II hood is required,a Type I or Type H hood shall be installed. 507.2.3 Domestic cooking appliances used for commer- cial purposes. Domestic cooking appliances utilized for Exception: Where cooking appliances are equipped with commercial purposes shall be provided with Type I or integral down-draft exhaust systems and such appliances Type H hoods as required for the type of appliances and and exhaust systems are listed and labeled for the applica- processes in accordance with Sections 507.2, 507.2.1 and tion in accordance with NFPA 96, a hood shall not be 507.2.2. required at or above them. 507.2.1 Type I hoods. Type I hoods shall be installed 507.2.4 Extra-heavy-duty. Type I hoods for use over extra-heavy-duty cooking appliances shall not cover where cooking appliances produce grease or smoke as a heavy-, medium- or light-duty appliances. Such hoods result of the cooking process. Type I hoods shall be installed over medium-duty, heavy-duty and extra-heavy- shall discharge to an exhaust system that is independent of other exhaust systems. duty cooking appliances. Type I hoods shall be installed over light-duty cooking appliances that produce grease or 5073 Fuel-burning appliances.Where vented fuel-burning smoke. appliances are located in the same room or space as the hood, Exception: A Type I hood shall not be required for an provisions shall be made to prevent the hood system from electric cooking appliance where an approved testing interfering with normal operation of the appliance vents. agency provides documentation that the appliance 507.4 Type I materials.Type I hoods shall be constructed of effluent contains 5 mg/m3 or less of grease when tested steel having a minimum thickness of 0.0466 inch(1.181 mm) 2012 INTERNATIONAL MECHANICAL CODEs 53 EXHAUST SYSTEMS 1 (No. 18 gage) or stainless steel not less than 0.0335 inch enclosure systems, as addressed in Section 506.3.11.2, shall [0.8525 mm(No.20 MSG)]in thickness. not be utilized to satisfy the requirements of this section. 507.5 Type H hood materials. Type II hoods shall be con- 507.11 Grease filters. Type I hoods shall be equipped with structed of steel having a minimum thickness of 0.0296 inch grease filters listed and labeled in accordance with UL 1046 (0.7534 mm) (No. 22 gage) or stainless steel not less than and designed for the specific purpose. Grease-collecting 0.0220 inch(0.5550 mm) (No. 24 gage)in thickness,copper equipment shall be provided with access for cleaning. The sheets weighing not less than 24 ounces per square foot(7.3 lowest edge of a grease filter located above the cooking sur- kg/m2)or of other approved material and gage. face shall be not less than the height specified in Table 507.6 Supports. Type I hoods shall be secured in place by 507.11. non-combustible supports. All Type I and Type 11 hood sup- TABLE 507.11 ports shall be adequate for the applied load of the hood, the MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A unsupported ductwork, the effluent loading and the possible GREASE FILTER AND THE COOKING SURFACE OR THE uIISu pp g p HEATING SURFACE weight of personnel working in or on the hood. ---- —-----—---- -- — HEIGHT ABOVE 507.7 Hood joints, seams and penetrations. Hood joints, TYPE OF COOKING COOKING SURFACE seams and penetrations shall comply with Sections 507.7.1 APPLIANCES (feet) and 507.7.2. Without exposed flame 0.5 507.7.1 Type I hoods. External hood joints, seams and Exposed flame and burners 2 penetrations for Type I hoods shall be made with a contin- Exposed charcoal and charbroil type 3.5 Li uous external liquid-tight weld or braze to the lowest out- For Si: 1 foot=304.8 mm. ermost perimeter of the hood.Internal hood joints, seams, 507.11.1 Criteria. Filters shall be of such size, type and penetrations, filter support frames and other appendages arrangement as will permit the required quantity of air to attached inside the hood shall not be required to be welded pass through such units at rates not exceeding those for or brazed but shall be otherwise sealed to be grease tight. which the filter or unit was designed or approved. Filter Exceptions: units shall be installed in frames or holders so as to be readily removable without the use of separate tools,unless 1. Penetrations shall not be required to be welded or designed and installed to be cleaned in place and the sys- brazed where sealed by devices that are listed for tem is equipped for such cleaning in place.Removable fil- the application. ter units shall be of a size that will allow them to be 2. Internal welding or brazing of seams,joints and cleaned in a dishwashing machine or pot sink. Filter units penetrations of the hood shall not be prohibited shall be arranged in place or provided with drip-intercept- provided that the joint is formed smooth or ing devices to prevent grease or other condensate from ground so as to not trap grease, and is readily dripping into food or on food preparation surfaces. cleanable. 507.11.2 Mounting position. Filters shall be installed at 507.7.2 Type H hoods.Joints, seams and penetrations for an angle of not less than 45 degrees (0.79 rad) from the Type H hoods shall be constructed as set forth in Chapter horizontal and shall be equipped with a drip tray beneath 6,shall be sealed on the interior of the hood and shall pro- the lower edge of the filters. vide a smooth surface that is readily cleanable and water 507.12 Canopy size and location.The inside lower edge of tight. canopy-type Type I and 1I commercial hoods shall overhang 507.8 Cleaning and grease gutters. A hood shall be or extend a horizontal distance of not less than 6 inches(152 designed to provide for thorough cleaning of the entire hood. mm) beyond the edge of the top horizontal surface of the Grease gutters shall drain to an approved collection recepta- appliance on all open sides.The vertical distance between the cle that is fabricated, designed and installed to allow access front lower lip of the hood and such surface shall not exceed for cleaning. 4 feet(1219 mm). 507.9 Clearances for Type I hood. A Type I hood shall be Exception: The hood shall be permitted to be flush with installed with a clearance to combustibles of not less than 18 the outer edge of the cooking surface where the hood is inches(457 mm). closed to the appliance side by a noncombustible wall or panel. Exception: Clearance shall not be required from gypsum 507.13 Capacity of hoods. Commercial food service hoods wallboard or /2 inch (12.7 mm) or thicker cementitious shall exhaust a minimum net quantity of air determined in wallboard attached to noncombustible structures provided accordance with this section and Sections 507.13.1 through that a smooth, cleanable, nonabsorbent and noncombusti- 507.13.5. The net quantity of exhaust air shall be calculated ble material is installed between the hood and the gypsum by subtracting any airflow supplied directly to a hood cavity or cementitious wallboard over an area extending not less from the total exhaust flow rate of a hood.Where any combi- than 18 inches(457 mm)in all directions from the hood. nation of heavy-duty, medium-duty and light-duty cooking 507.10 Hoods penetrating a ceiling. Type I hoods or por- appliances are utilized under a single hood, the exhaust rate tions thereof penetrating a ceiling, wall or furred space shall required by this section for the heaviest duty appliance cov- comply with Section 506.3.11. Field-applied grease duct ered by the hood shall be used for the entire hood. 54 2012 INTERNATIONAL MECHANICAL CODE 2012 International Mechanical Code 2. A Type I hood shall not be required in an R-2 type occupancy with not more than 16 residents. 507-23 Domestic cooldn;appliance used for commercial purposes. Domestic cooking appliances utilized for commercial purposes shall be provided with Type L Type 11 or residential hoods as required for the type of appliances and processes in accordance with Table 507.2.2 and Sections 507.2,507.2.1 and g07.2.1 Type I hoods.Type I hoods shall be installed-where 50722. cooking appliances produce grease or smoke.Type I hoods shall be installed over medium-duty,heavy-duty and extra- heavy-duty cooking appliances.Type I hoods shall be installed over light-duty cooking appliances that produce grease or smoke. Exceptions: ' 1. A Type I hood shall not be required for an electric cooking appliance inhere an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or less of grease when tested at an exhaust flow rate of 500 chn in accordance with Section 17 of UL 71013. (Insert Facing Page 53) Effective July 1,2013 Washington State Amendments TABLE 507.2.2 TYPE OF HOOD REQUIRED FOR DOMESTIC COOKING APPLIANCES IN THE FOLLOWING SPACES°'b Type of Space Type of Cooking Type of Hood 1. Boiling,steaming and warming precooked food Type II hood Church 2. Roasting,pan frying and deep frying Type I hood Commumty or I. Boiling,steaming and warming precooked food Residential hood` or Type II hoods party room in apartment and 2. Roasting,pan frying and deep frying Type I hood condominium 1. Boning,steaming and warming precooked food Residential hood` Day care or Type II hoods 2. Roasting,pan frying and deep flying Type I hood Dormitory, 1 Boilin&steaming and warming precooked food Type H hood boarding home, and d g Type I hood nursinghome 2. Roasting pan flying deep frying 1. Boiling steaming and warming precooked food Residential hood` Office lunch room or Type H hood 2. Roasting pan flying and deep frying Type I hood a. Commercial cooking appliances shall comply with Section 507.2. b. Requirements in this table apply to electric or gas fuel appliances only.Solid fuel appliances or charbroners require Type I hoods. c. Residential hood shall ventilate to the outside. d_ Type II hood required when more than one appliance is used. (Insert as Page 53a) Effective July 1,2013 i 2012 International Mechanical Code Gd4A nMX Effective July 1,2013 EXHAUST SYSTEMS 507.13.1 Extra-heavy-duty cooking appliances. The 507.14 Noncanopy size and location. Noncanopy-type minimum net airflow for hoods,as determined by Section hoods shall be located a maximum of 3 feet(914 mm)above 507.2,used for extra-heavy-duty cooking appliances shall the cooking surface.The edge of the hood shall be set back a be determined as follows: maximum of 1 foot (305 mm) from the edge of the cooking Type of Hood CFM per linear foot of hood surface. Backshelf/pass-over Not allowed 507.15 Exhaust outlets. Exhaust outlets located within the Double island canopy hood shall be located so as to optimize the capture of particu- (per side) 550 late matter. Each outlet shall serve not more than a 12-foot Eyebrow Not allowed (3658 min)section of hood. Single island canopy 700 507.16 Performance test. A performance test shall be con- Wall-mounted canopy 550 ducted upon completion and before final approval of the For SI: 1 cfrn per linear foot=1.55 Its per linear meter. installation of a ventilation system serving commercial cook- 507.13.2 Heavy-duty cooking appliances.The minimum ing appliances. The test shall verify the rate of exhaust air- net airflow for hoods, as determined by Section 507.2, flow required by Section 507.13,makeup airflow required by used for heavy-duty cooking appliances shall be deter- Section 508 and proper operation as specified in this chapter. mined as follows: The permit holder shall furnish the necessary test equipment Type of Hood CFM per linear foot of hood and devices required to perform the tests. Backshelf/pass-over 400 507.16.1 Capture and containment test. The permit Double island canopy 400 holder shall verify capture and containment performance (per side) of the exhaust system. This field test shall be conducted Eyebrow Not allowed with all appliances under the hood at operating tempera- Single island canopy 600 tures,with all sources of outdoor air providing makeup air Wall-mounted canopy 400 for the hood operating and with all sources of recirculated For SI: 1 cfm per linear foot=1.55 Ls per linear meter. air providing conditioning for the space in which the hood 507.133 Medium-duty cooking appliances. The mini- is located operating.Capture and containment shall be ver- ified visually by observing smoke or steam produced by mum net airflow for hoods, as determined by Section actual or simulated cooking, such as with smoke candles, 507.2, used for medium-duty cooking appliances shall be smoke puffers,etc. determined as follows: Type of Hood CFM per linear foot of hood Backshelf/pass-over 300 SECTION 508 Double island canopy 300 COMMERCIAL KITCHEN MAKEUP AIR (per side) 508.1 Makeup air.Makeup air shall be supplied during the Eyebrow 250 operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of Single island canopy 500 makeup air supplied to the building from all sources shall be Wall-mounted canopy 300 approximately equal to the amount of exhaust air for all For SI: i cfm per linear foot=1.55 Ls per linear meter. exhaust systems for the building. The makeup air shall not 507.13.4 Light-duty cooking appliances. The minimum reduce the effectiveness of the exhaust system. Makeup air shall be provided by gravity or mechanical means or both. net airflow for hoods, as determined by Section 507.2, Mechanical makeup air systems shall be automatically con- used for light-duty cooking appliances and food service trolled to start and operate simultaneously with the exhaust preparation shall be determined as follows: system. Makeup air intake opening locations shall comply Type of Hood CFM per linear foot of hood with Section 401.4. Backshelf/pass-over 250 508.1.1 Makeup air temperature. The temperature dif- Double island canopy 250 ferential between makeup air and the air in the conditioned (per side) space shall not exceed 10°F(6°C)except where the added Eyebrow 250 heating and cooling loads of the makeup air do not exceed Single island canopy 400 the capacity of the HVAC system. Wall-mounted canopy 200 508.2 Compensating hoods.Manufacturers of compensating hoods shall provide a label indicating minimum exhaust flow For SI: 1 din per linear foot=1.55 Us per linear meter. and/or maximum makeup airflow that provides capture and 507.135 Dishwashing appliances.The minimum net air- containment of the exhaust effluent. flow for Type H hoods used for dishwashing appliances Exception: Compensating hoods with makeup air sup- shall be 100 CFM per linear foot of hood length. plied only from the front face discharge and side face dis- Exception: Dishwashing appliances and equipment charge openings shall not be required to be labeled with installed in accordance with Section 507.2.2. the maximum makeup airflow. 2012 INTERNATIONAL MECHANICAL CODE® 55 EXHAUST SYSTEMS SECTION 509 convey combustible dusts shall be provided with an FIRE SUPPRESSION SYSTEMS approved explosion-control system. 509.1 Where required. Commercial cooking appliances [F)510.2.2 Combustible fibers.Equipment or machinery required by Section 507.2.1 to have a Type I hood shall be within a building which generates or emits combustible provided with an approved automatic fire suppression system fibers shall be provided with an approved dust-collecting complying with the International Building Code and the and exhaust system. Such systems shall comply with this International Fire Code. code and the International Fire Code. 510.3 Design and operation.The design and operation of the SECTION 510 exhaust system shall be such that flammable contaminants HAZARDOUS EXHAUST SYSTEMS are diluted in noncontaminated air to maintain concentrations • 510.1 General.This section shall govern the design and con in the exhaust flow below 25 percent of the contaminant's - lower flammability limit. struction of duct systems for hazardous exhaust and shall determine where such systems are required. Hazardous 510.4 Independent system.Hazardous exhaust systems shall exhaust systems are systems designed to capture and control be independent of other types of exhaust systems.Incompati- hazardous emissions generated from product handling or pro- ble materials,as defined in the International Fire Code, shall cesses, and convey those emissions to the outdoors. Hazard- not be exhausted through the same hazardous exhaust system. ous emissions include flammable vapors, gases,fumes,mists Hazardous exhaust systems shall not share common shafts or dusts, and volatile or airborne materials posing a health with other duct systems, except where such systems are haz- hazard, such as toxic or corrosive materials.For the purposes ardous exhaust systems originating in the same fire area. of this section, the health hazard rating of materials shall be Exception:The provision of this section shall not apply to as specified in NFPA 704. laboratory exhaust systems where all of the following con- For the purposes of the provisions of Section 510, a labo- ditions apply: ratory shall be defined as a facility where the use of chemi- 1. All of the hazardous exhaust ductwork and other cals is related to testing, analysis, teaching, research or laboratory exhaust within both the occupied space developmental activities. Chemicals are used or synthesized and the shafts are under negative pressure while in on a nonproduction basis,rather than in a manufacturing pro- operation. cess. 2. The hazardous exhaust ductwork manifolded 510.2 Where required.A hazardous exhaust system shall be together within the occupied space must originate required wherever operations involving the handling or pro- within the same fire area. cessing of hazardous materials, in the absence of such exhaust systems and under normal operating conditions,have 3. Each control branch has a flow regulating device. the potential to create one of the following conditions: 4. Perchloric acid hoods and connected exhaust shall 1. A flammable vapor, gas, fume, mist or dust is present be prohibited from manifolding. in concentrations exceeding 25 percent of the lower 5. Radioisotope hoods are equipped with filtration and/ flammability limit of the substance for the expected or carbon beds where required by the registered room temperature. design professional. 2. A vapor, gas, fume, mist or dust with a health-hazard 6. Biological safety cabinets are filtered. rating of 4 is present in any concentration. 7. Provision is made for continuous maintenance of 3. A vapor, gas, fume, mist or dust with ahealth-hazard rating of 1, 2 or 3 is present in concentrations exceed- ing 1 percent of the median lethal concentration of the Contaminated air shall not be recirculated to occupiable substance for acute inhalation toxicity. areas. Air containing explosive or flammable vapors, fumes Exception: Laboratories, as defined in Section 510.1, or dusts; flammable, highly toxic or toxic gases; or radioac- except where the concentrations listed in Item 1 are tive material shall be considered to be contaminated. exceeded or a vapor,gas,fume,mist or dust with a health- 510.5 Design. Systems for removal of vapors, gases and hazard rating of 1, 2, 3 or 4 is present in concentrations smoke shall be designed by the constant velocity or equal exceeding 1 percent of the median lethal concentration of friction methods. Systems conveying particulate matter shall the substance for acute inhalation toxicity. be designed employing the constant velocity method. [F) 510.2.1 Lumber yards and woodworking facilities. 510.5.1 Balancing. Systems conveying explosive or Equipment or machinery located inside buildings at lum- radioactive materials shall be prebalanced by duct sizing. ber yards and woodworking facilities which generates or Other systems shall be balanced by duct sizing with bal- emits combustible dust shall be provided with an approved ancing devices, such as dampers. Dampers provided to dust-collection and exhaust system installed in confor- balance airflow shall be provided with securely fixed min- mance with this section and the International Fire Code. imum-position blocking devices to prevent restricting flow Equipment and systems that are used to collect,process or below the required volume or velocity. 56 2012 INTERNATIONAL MECHANICAL CODE" Page 1 of 1 Debbera Coker- Cannabis Care, PAR2014-00045 From: Debbera Coker To: Adkins, Barbara Date: 6/25/2014 12:34 PM Subject: Cannabis Care, PAR2014-00045 CC: Borden, Allan Hello Barb, I was very surprised that the representatives who attended the pre-application meeting for the Cannabis Care Foundation were totally clueless about requirements to comply with Ordinance 30-13, Collective Garden amendments to Title 17. The representatives"assured"Allan and I that the requirements do not apply to them because they provide"access" and do not grow. Documents containing the requirements outlined in Title 17 were given to the representatives. They were told that Allan and Debbera need to discuss with the Director to confirm whether there are exceptions we were not aware of related to dispensers (access providers)who are not growing. Your comments please...... De66era Coker Mason County Building Department Building Inspector IV/Code Enforcement Phone: (360)427-9670 ext 510 FAX: (360) 427-7798 E-Mail: DLC(c co.mason.wa.us 426 West Cedar Street Shelton, WA 98584 I i file://C:\Documents and Settings\Dlc\Local Settings\Temp\XPgrpwise\53AAC1E7Masonmai1100170357... 6/25/2014 �Sor 00U�� MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street -- _ PO Box 186, Shelton, WA 98584 1854 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269 MASON COUNTY PRE-SUBMISSION CONFERENCE NOTES BUILDING DEPARTMENT REPRESENTATIVE: Debbera Coker(360) 427-9670 EXT 510 E-Mail: DLC(cD-co.mason.wa.us Larry Waters (360)427-9670 ext. 285 E-mail: LAW(cD-co.mason.wa.us DATE: June 25, 2014 PROJECT/ PROJECT TRACKING NUMBER : PAR2014-00045 PROJECT REPRESENTATIVE(S) or APPLICANT: Cannabis Care Foundation, Matthew Wyble PROJECT DESCRIPTION & SIZE: Collective Garden, sales of medical cannabis and foods & information center When an existing structure will be used to operate a Collective Garden in accordance with Mason County Code 17.09 the applicant may use the Change in Tenant application form to obtain a permit. Complete the application form following all instructions. Include required documents including a floor plan drawn to scale. In addition to items listed on the form be sure to identify all elements required for a Collective Garden as specified in 17.09.003, items A through M. When the permit application is submitted the permit will be routed to all relevant departments to verify compliance to department regulations. When all departments have approved the permit application the permit will be issued and required inspections performed. Occupancy approval will be granted after all required inspections are completed and approved. If new construction is proposed plans shall be required that demonstrate compliance to Mason County Code 14.17.140. Construction plans shall include design details and information sufficient to identify design specifications • OCCUPANCY CLASSIFICATION & USE: The occupancy classification for the existing building has been approved assembly or restaurant purposes and as a retail space. To cultivate and deliver medical cannabis the occupancy classification is considered "F°to cultivate and "B" to deliver. As proposed the building and fire codes would approve the existing structure for the use provided all elements required in 17.09.003#'s A through M are installed. • SETBACKS TO PROPERTY LINES: A site plan, drawn to scale, shall clearly identify setback dimensions, and required fencing on a site plan. • DISTANCES TO OTHER STRUCTURES: NOT APPLICABLE. Site plan, drawn to scale shall clearly identify distances, where required include fire-resistive details, including continuity, &tested assembly details. • ENGINEERING REQUIRED: May be required when new construction occurs When required, ALL PLAN PAGES SHALL BE STAMPED AND SIGNED BY THE DESIGN PROFESSIONAL. • GEOTECH REPORT REQUIRED? NO • SPECIAL INSPECTION: REQUIRED. NO Referencing IBC Chapter 17, Section 1704.1.1. Statement of special inspections prepared by registered design professional in responsible charge. Complete a Special Inspection authorization form. • OTHER: A permit shal► be required for a 10-ft fence required in accordance with 17.09.003, #'s F and G. Construction plans and details may be included with the Change in Tenant permit application. The structure includes a kitchen. Identify the type of cooking that will take place in the kitchen and identify the type of hood in the kitchen. See IMC 507.2 enclosed. When cooking grease or smoke a type I hood and duct system shall be required SEE Fire Marshal notes. A separate fire protection permit shall be required for the fire protection systems specified in 17.09.003 item # I. Plans and details demonstrating compliance to the 2012 International Fire Code shall be provided for the NFPA13 (automatic fire sprinkler) and NFPA 72 (monitored fire alarm ) systems. PERMITS REQUIRED FOR PROJECT E BUILDING, APPLIES TO NEW CONSTRUCTION E PLUMBING/ MECHANICAL, APPLIES TO NEW PLUMBING AND MECHANICAL, including ventilation system, reference 17.0.003, #D ❑ GRADING PERMIT (When greater than 200 cubic yards) E CHANGE IN TENANT E FIRE SUPPRESSION - See Fire Marshal comments ❑ SIGN, include sign information with permit application documents E FENCE When applicable, greater than TO" above grade) El ADDITIONAL NOTES: WHEN YOU ARE READY, SUBMIT FOUR (4 SITE PLANS, DRAWN TO SCALE ALONG WITH THREE (3) COMPLETE SETS OF BUILDING PLANS INCLUDING THE FOLLOWING. (NOTE, ALL PLAN PAGES SHALL BE STAMPED BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE: • CONSTRUCTION PLANS, drawn to scale. Include floor plan, elevations, cross section, cross section, construction details, etc. • MECHANICAL PLAN, • PLUMBING PLAN AND • DEFERRED SUBMITTAL WILL NOT BE ACCEPTED. • A PLAN REVIEW FEE WILL BE COLLECTED WHEN THE BUILDING PERMIT IS SUBMITTED. VALUATIONS ARE BASED UPON THE MOST RECENT BUILDING STANDARDS VALUATION DATA RECOMMENDATIONS AND THE PERMIT FEE WILL BE DETERMINED BASED UPON TABLE 1-A OF THE 1997 UBC. REFERENCE CODE EDITIONS: Effective July 1, 2013 2012 INTERNATIONAL BUILDING CODE (IBC), INCLUDING APPENDIX CHAPTERS C, E AND H, EXCLUDING H106; SECTIONS 101 THROUGH 107, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND EXCLUDING APPENDIX CHAPTERS A, B, D, F, G, I, J AND K AND; ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51- 50, AND THE 2009 INTERNATIONAL EXISTING BUILDING CODE. 2012 UNIFORM PLUMBING CODE (UPC), PUBLISHED BY THE INTERNATIONAL ASSN. OF PLUMBING AND MECHANICAL OFFICIALS(IAPMO) AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51-56 AND WAC 51-57, EXCLUDING SECTIONS 102.4 AND CHAPTERS 12, 15, AND 16, PART I. 2012 INTERNATIONAL MECHANICAL CODE (IMC), PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, AND THE 2009 INTERNATIONAL FUEL GAS CODE AS ADOPTED THROUGH THE WASHINGTON STATE BUILDING CODE WAC 51-52. 2012 INTERNATIONAL FIRE CODE, PUBLISHED BY THE INTERNATIONAL CODE COUNCIL, EXCLUDING APPENDIX A, D, AND K AND ADOPTING APPENDICES B,C,E,F, G AND ADOPTING THE WASHINGTON STATE BUILDING CODE WAC 51- 54. 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC), AS AMENDED BY WASHINGTON STATE BUILDING CODE WAC 51-11 To view the Mason County Building and Construction Code and adopted amendments go to the Mason County website at: www.co.mason.wa.us. DESIGN CRITERIA: SEISMIC ZONE: D2 WIND LOAD: 85 MPH, Exp depending upon site SNOW LOAD: 25 psf .I Z. PAR �D14- of`y DATE 1p-�q- aD 14 PRE-APPLICATION CONFERENCE REQUEST FORM - I The purpose of the pre-submission conference is to identify and/or eliminate as many potential problems as possible in order for the project to be processed without delay. Representatives for the Fire Marshal's Office, Building Department, Environmental Health, Planning, and Public Works Departments may attend the meeting to discuss rules and regulations applicable to the proposed project. Topics covered during the meeting will include the comprehensive plan, shoreline program, zoning, availability of sewer and potable water, development concepts, building construction, fire protection and life safety concerns of the proposed project. The pre-submission conference will be most informative when you provide accurate and detailed information on the Pre-Application Conference Application Form and the site plan.Applications will be accepted when all information is received and deemed complete. Pre-Application Conferences are held every Wednesday and last up to one hour. To schedule a meeting complete the applications and return with 10 copies of the detailed site plan, by 3:00 PM on the Wednesday two weeks prior to the proposed meeting. 1.Pre-Application/Dept. of Community Dev. 2. Environmental Health 426 W Cedar Street/PO Box 279 415 N 5b /PO Box 1666 Shelton, WA 98584 Shelton, WA 98584 360.427.9670 ext. 352 360.427.9670 ext. 400 Cbeck amount: $255.00 Cbeck amount: S150.00 BOTH CHECKS MADE PAYABLE: MASON COUNTY TREASURER Applicant /' ,� Site Plan Name: (, a xm!\D \S 106��� 1 ����� Submit 6 copies Mailing Address: a3 LWA \ ho-1 P yC 0 VN Include the following information Daytime Telephone: I(c 55 2•ILA ZD Fax: ❑ Indicate Scale and North Arrow Email address: ❑ Property line dimensions,easements, and right-of-ways. Representative r Name:Tm( \k��J U \p El The location of all existing and proposed structures.Include square Mailing Address: '�45 )L4 t,3 t- S t2_� footage of existing and proposed structures. Daytime Telephone: 3 fo • '�j-1 I Fax: ❑ Setback distance,in feet from all Email address: property lines and structures. Parcel Number: (I2 digits) 0 l y ❑ Existing and proposed road access to and from the site. Description of Project: Include: 1) Square footage of structure, 2)Use of building and rooms(i.e., ❑ Parking sites office,warehouse,restaurant, storage, etc), 3) Occupancy classification per ❑ Location of on-site sewage tanks and drainfields. IBC, Section 302.1, and construction type. 4)Provide two sets of plans, if ❑ Location of drinking water supply. available. Use separate sheet if necessary Include location on the proposed site of ��I £ and surrounding parcels. e 1 f G_ ❑ Steep bluffs,wetlands,streams,and �1 bodies of water ❑ Location of fire hydrants and emergency vehicle access roads, including grade. ❑ Surface and storm water run-off routes. Has the project been discussed during a previous Pre-Application Conference: If yes,please indicate date. U Will the building have employees? If yes, how many? What is the water availability o the proposed project? If there qexisting well, what is the name,of the system? What is planned for the on-site sewage system? If you e proposing a new on-site,system provide detail on the required site plan. Ll 1(�AMP ADDITIONAL INFORMATION: APPLICABLE BUILDING CODES 2012 International Building Code/2009 International Residential Code 2012 International Fire Code-ANSI A117 2012 International Mechanical Code—WAC 51-42 2012 Uniform Plumbing Code—WAC 51-56/51-47 2012 International Energy Cons. Code/Washington State Energy Code—WAC 51-11C&51-11R Mason County Ordinance Title 14 Code changes are on a 3 year cycle; effective in July of that particular year. Date of Conference: ]- a S_ Time of Conference: Location of Conference: 426 west Cedar Street,Shearon Planner I [An ext. _ ar_D — bz — —} r s a.a ch l '£ — r lzi ��a V M3 own" E W M e ,.. gC2 . 3 Z' A nQ Yoh e� J� �► shot N ( � 1 N F;r vG + ,e 'oo zq . `1 9�7-- �St ' SQL I-! V�odo�Sta Vei SIS CARE FOUNoApop,� MIM IM s 4!, WIM `t " It1PIIIArl WAI'%ail"IS _ b7'L(111��I'"ii1J(�11 m- t 101Al414;1 l rPM 'i <u i �n b+n�rs PRE-SUBMISSION MEETING DATE OF MEETING: "AER: Grace Allan Rebecca Michael PUiVift WORKS: Fred Perryman - all (departmental mail) 1XJ00 � RIJILDING DEPT: Lar ters - aW O(CI H, H: Ben Schenk-Food Consumption/Sales Only-Basket on EH desk ALTH: Cindy Waite- all - Basket on EH desk FlF DEPARTMENT FOR AREA: (Mail Packet- See map in pre-app book) P,UR#1 OR PUD #3: (Mail) All are PUD#3 except Union,Hoodsport, Lilliwaup CITYt,OPSHELTON: Any address in UGA or within 1000' of city limits. vvv Steve Goins Director Dept. of Community Development 525 W Cota Street Shelton WA 98584 POEMW SHELTON: When located in their complex. (In doubt-ask Grace) Airport-Public Works area-Johns Prairie Port of Shelton,John Dobson 21 W Sanderson Way Shelton WA 98584 PRE-SUBMISSION MEETING FOIZ WEDNESDAY,JUNE 25TH, 2014 PAR2014-00044 APPLICANT: HERBAN TREE FARMERS MEETING DATE AND TIME WED, JUKE 25TH, 2014 9:15/9:30 - 10:30 PARCEL NUMBER: 22329-34-90013 SITE ADDRESS: I I I NE RANCH DR. TAHUYA PROJECT DESCRIPTION: GROWING & PROCESSING CANNABIS LOCATION: BUILDING 3, 426 W. CEDAR STREET, SHELTON, WA. 98584 PLANNER: ALLAN BORDEN EXT. 365 ENVIRONMENTAL HEALTH: CINDY WAITE, EXT. 353 ***PAR2014-00045*** APPLICANT: CANNABIS CARE FOUNDATION MEETING DATE AND TIME WED, JUNE 25TH, 2014 10:45/11:00-12:00 PARCEL NUMBER: 12329-43-00140 SITE ADDRESS: 23491 NE SR 3 BELFAIR PROJECT DESCRIPTION: SALES OF MEDICAL CANNABIS & FOODS & INFORMATION CENTER LOCATION: BUILDING 3, 426 W. CEDAR STREET, SHELTON, WA. 98584 PLANNER: ALLAN BORDEN EXT. 365 ENVIRONMENTAL HEALTH: CINDY WAITE, EXT. 353 *** LAST MINUTE ADDITION TO AGENDA*** i PRE-SUBMISSION MEETING FOR WEDNESDAY,JUNE 25TH, 2014 PAR2014-00044 APPLICANT: HERBAN TREE FARMERS MEETING DATE AND TIME WED, JUNE 25TH, 2014 9:15/9:30 - 10:30 PARCEL NUMBER: 22329-34-90013 SITE ADDRESS: I I I NE RANCH DR. TAHUYA PROJECT DESCRIPTION: GROWING & PROCESSING CANNABIS LOCATION: BUILDING 3, 426 W. CEDAR STREET, SHELTON, WA. 98584 PLANNER: ALLAN BORDEN EXT. 365 ENVIRONMENTAL HEALTH: CINDY WAITE, EXT. 353 ***PAR2014-00045*** APPLICANT: CANNABIS CARE FOUNDATION MEETING DATE AND TIME WED,JUNE 25TH, 2014 10:45/11:00-12:00 PARCEL NUMBER: 12329-43-00140 SITE ADDRESS: 23491 NE SR 3 BELFAIR PROJECT DESCRIPTION: SALES OF MEDICAL CANNABIS & FOODS & INFORMATION CENTER LOCATION: BUILDING 3, 426 W. CEDAR STREET, SHELTON, WA. 98584 PLANNER: ALLAN BORDEN EXT. 365 ENVIRONMENTAL HEALTH: CINDY WAITE, EXT. 353 *** LAST MINUTE ADDITION TO AGENDA*** (Y\ H .7r,TAV"vhv S�' V6,:, P xc 3cN h N I AIOIZ i 3j ordSN/ __ 7W SNt tlt /V0 1 I cnjinb3b N'Vld 311S r "J0 NOSb'W i t.. t 8 d d 9W)l dd I► � � 3';11�1'dt11N3 c� h m+f bhE Z m FGEIVE ]AN 15 2009'' lranct� tid4 }ctt ( S rR z J U'ABR OFFICE; j —{ 1 O �z �v -t'►�w S r --c 'Ib h�O11t QQ� v EXHIBIT - "A" LEGAL DESCRIPTION That part of the North 100 feet of the South 200 feet of the Southwest quarter of the Southeast quarter of Section 29, Township 23 North, Range 1 West, W.M., lying Westerly of Primary State Highway No. 3. Situate in Mason County, Washington. EXHIBIT Eases Park- Cadema Puking