Loading...
HomeMy WebLinkAboutCOM2006-00011 - COM CD Environmental Health Review - 2/13/2006 � 17 MASON COUNTY DEPARTMENT OF HEALTH SERVICES ' February 13, 2006 PO BOX 1666 Shelton WA 98584 Shelton (360)427-9670 Fax (360)427-8442 SYS ENTERPRISES, LLC Elms (360)482-5269 PO BOX 3380 BELFAIR WA 98528 Bdta r (360)275 4467 Case No.:COM2005-00011 Parcel No.: 123291490060 Dear Applicant: as Your building permit cannot be approved by Mason County Environmental Health un61 the following are completed and turned In: Report within the last three years from either a septic tank pumper or an Operation and Maintenance Specialist. Pleasq see comments at the end of this letter. Please calf me at(360)427-9670, ext. 554 if you have any questions: - Sincerely, Trish Woolett Environmental Health Mason County Health Services Comments: NEED A CURRENT O&M REPORT FOR THE SEPTIC SYSTEM, WILL ALSO NEED A LETTER FROM A SEPTIC DESIGNER SHOWING THIS SYSTEM WILL SUPPORT THE INCREASE USE AS THE ORIGINAL SYSTEM WAS DESIGNED FOR 4 EMPLOYEES. 2/13/2006 - ,,,: . 1 of 1 COM2006-00011 ,�;,1 Engineering Services Associates, Inc. Thursday, February 23, 2006 Rick Lucas STS Enterprises, LLC PO Box 3380 Belfair, WA 98528 Subject: Case No. COM2006-00011 Dear Rick, ' I understand that you wish increase the employees at Belfair Marine from 3 to 6 employees. The system I designed in 1993 anticipated that the,flow to the drainfield would be approximately 100 gallons per day. Based on recent EPA Risk Management Research for On Site Waste Water Treatment and Disposal Systems (Copy of Table Enclosed) a waste water flaw of 15 gallons per day per employee would be the anticipated flow to the system. Based on a flow of 15 gallons per day per employee, the system should be able to process the waste from 6 employees with no problems. YouilLG- Pat McCullough, 1E President, ESA Inc. Engineering Be 1 Ass«Ines Inc 210 N.E.Cherokee Beach,BeBnr,Wash1ngbn.98528 (080)275-73" j ,i FAX(080)2Tr-0187 rage 6 or 31 For nonresidential establishments typical daily flows from a variety of commercial, institutional, shown in tables 3-4 to 3-6 (Crites and Tchobanoglous, 1998; Tchobanoglous and Burton, 199' necesgarily an average of the range of values but rather are weighted values based on the typ Actual monitoring of speck wastewater flow and characteristics for nonresidential establishm, Alternatively, a similar establishment located in the area might provide good information. If this local regulatory agencies should be consulted for approved design flow guidelines for nonresic flows provided by regulatory agencies are very conservative estimates based on peak rather tt agencies might accept only their established flow values and therefore should be contacted be Table 34.Typical wastewater flow rates from commercial sources,,b Flow, gallons/unit/day Flow, liters/una/day Facility Unit Range Typical Range Typical Airport, Passenger 24 3 8-15 11 Apartment house Person 40-80 50 150-300 190 Automobile servi Vehicle 8-15 12 30-57 45 stationc served es 9-15 13 34-57 49 Bar Customer 1-5 3 4-19 11 Employees 10-16 13 38-61 1 49 Boarding house Person 25-60 40 95-230 150 Toilet 1 500. Department store room 400800 500 2,300 1,900 Employee 8-15 10 30-57 38 Hotel Guest 40-60 50 150-230 190 Employee B-13 10 3049 38 Industrial building Employee 7-16 13 2681 49 (sanitary waste only) Machine 450-650 550 1'706- 2100 Laundry (sal!-service) Wash 45-55 50 170.2,500210 190 Office Employee 7-16 13 2681 49 Public lavatory User 38 5 11-23 19 Restaurant(with toilet) Meal 24 3 8-15 11 Conventional Customer 8-10 9 30-38 34 Short order Customer 3-8 6 11-30 23 Bar/cocktail lounge Customer 24 3 8- 111 Employee 7-13 10 2849 38 Shopping center Parking 1-3 2 4-11 8 Space Theater Seat 24 3 8-15 11.Some systems serving more than 20 people might be regulated under USEPA's Class V Underground Injection Control (UIC) Program. See htto'//www eoa cov/safewaterluic html for more information. http://www.cp&gov/ORD/NRMRUpubs/625r00008/html/625R00008chap3.htm 2/9/2005 °These data incorporate the effect of fixtures complying with the U.S. Energy Policy Act (EPACT) of 1994, `Disposal of automotive wastes via subsurface wastewater infiltration systems is banned by Class V UIC regulations to protect ground water. See httD: www eoa tlov/safewater/uic html for more information. Source: Crites and Tchobanoglous, 1998. Table 3-5. Typical wastewater flow rates from institutional sources- Flow, gallons/uniVday Flow, lib Facility Unit Range Typical Range Assembly hall Seat 24 3 8-15 Hospital, medical Bed 125-240 165 470-910 Employee 5-15 10 19-57 Hospital, mental Bed 75-140 100 280-530 Employee 5-15 10 19-57 Prison Inmate 80-150 120 300-570 Employee 5-15 10 19-57 Rest home Resident 50-120 90 190450 Employee 6-15 10 19-57 School,day-only: With cafeteria,gym, showers Student 1530 25 57-110 With cafeteria only Student 10-20 15 38-78. .. Without cafeteria, gym, or showers Student 5-17 11 19-64 School, boarding Student 50-100 75 190-380 'Systems serving more than 20 people might be regulated under USEPA's Class V UIC Program. See http�/Aww.epa.gov/safewater/uic,html for more information. - Source: Crites and Tchobanoglous, 1998. Table 3-6.Typical wastewater flow rates from recreational facilities' Flow, gallons/unit/day Facility Unit Range Typical F Apartment, resort Person 50-70 60 Bowling alley Alley 250 200 Cabin, resort Person 6-50 40 Customer 1-3 2 Cafeteria Employee 8-12 10 http://www.epa.gov/ORD/NRMRL/pubsl625r00008/html/625R00008chap3.htm 2/9/2005 rage 1u oI 81 Camps: Pioneer type Person 15-30 25 Children's,with central toilet/bath Person 35-50 45 Day,with meals Person 10-20 15 Day,without meals Person 10-15 13 Luxury, private bath Person 75-100 90 Trailer camp Trailer 75-150 125 Campground-developed Person 20-40 30 Cocktail lounge Seat 12-25 20 Coffee Shop Customer 4-8 6 Employee 8-12 10 . Country club Guests onsite 60-130 100 Employee 10-15 13- Dining hall Meal served 4-10 7 Dormitory/bunkhouse Person 20-50 40 Fairground Visitor 1-2 2 Hotel, resort Person -40-60 50 _ Picnic park,flush toilets Visitor 5-10 8 Store, resort Customer 1-4 3 Employee 8-12 10 Swimming pool Customer 5-12 10 Employee 8-12 10 - Theater Seat 2-4 3 Visitor center Visitor 4-8 5 "Some systems serving more than 20 people might be regulated under USEPA's Class VUIC Program: Source: Cries and Tchobanoglous, 1998. 3.3.3 Variability of wastewater flow Variability of wastewater flow is usually characterized by daily and hourly minimum and maxim flows that occur during the day. The intermittent occurrence of individual wastewateryeneratin in wastewater flows from residential or nonresidential establishments. This variability can affec potentially causing hydraulic overloads of the system during peak flow conditions. Figure 3-3 it wastewater flows for a typical residential dwelling. Figure 3.3. Daily Indoor water use pattern for single-family residence http://www.ep&gov/ORD/NRN4RL/pubs/625r00008ihtmP625R00008chap3.htm _ 2/9/2005 Septic Tank Pump & Service Report ❑ Residential' ❑Motel ❑ Food Service Restaurant ❑RV Park ❑Youth Camp @,Other,Please Describe: t- ❑Campground ❑Mobile Home Park Space A_ Property Owner Phone# t` Business name(if applicab/e)�E`-FA�Z MAZ„-aF C�0YG I2 Mailing address City State_Zip Site address I7-0 I'L le OLb \N tAwt, city ��-F�t� Tax parcel At — — - - - - - - - - - - - - SEPTIC TANK Tank Size t7-00 Gallons #of Compartments. 2 Tank Construction: .Manufactured ❑Home Made Tank Materlat. A Metal ❑Wood 9-Concrete ❑ Fiberglass ❑Other Effluent Level ❑ High 0-Normal ❑Low Tank Condition: Matisfactory ❑ Needs Repair Tank Pumped: dales ❑ No Were repairs made to the tank? ❑ Yes RLNo If yes, please explaln. BAFFLES Inlet Baffle Condition: IgSatisfactory ❑ Needs Repair Outlet Baffle Conditiorr MSatisfactory ❑ Needs Repair Center Baffle Conditlom IgSatlsfactory ❑ Needs Repair ❑ Not Applicable Effluent Filter Cleaned? IdYes ❑ No ❑ Not Applicable Were repairs made to the baffles? ❑Yes 6vo If yes, please explain: PUMP OR SURGE TANK t6-Yes ❑ No If yes, tank size: -w�5CD Gallons Were repairs made to the pump or surge tank? ❑Yes 6No If yes,please explaln: e SEPTAGE Depth of Floating Mat tat Compartment: t-7- 2nd compartment Pump Tank I Depth of Sludge 1st Compartment: 1�� 2nd compartment 'g r Pump Tank 3 Total Gallons Pumped I A�Oo Disposal Fac,ility. Iffi,Biorecycle O Other: General Comments G4 �� ��5 xv� o P-x03c-L 5 Date Pumped t.?, 7-t 2ootn Recommended Next Pumping Date 3 -h ytr�RS Certified Pumper Signature r^^ c7--X Company NameIG- Findings and determinations of this inspection rallect conditions as they existed on the day the septic tank was pumped.No claim is made by this company,either expressed or implied,concerning success or failure of the septic system. Mason County Department of Health Services•426 W Cedar• Mason County Building III ., PO Box 1666• Shelton,WA 98584• (360) 427-9670 ext. 352 White copy-Health Department Yellow copy--Pumper Pink copy-Owner C^tdneT - �aMGt Y LL$ o g ° N a r g � � S o � e t . 801 1 1 L H Z N p W N S p i � w 444 W O V 2 131 ' cW c7 �Y a 0 0 O y a 4a mq g N {mq{SS . jvA � - ia�ry Q ' :(] M � c'