Loading...
HomeMy WebLinkAboutBLD N/A Car Wash - BLD Application - 5/24/1989 BUILDING PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED PERMIT NO. OWNER NAME MAILADDRESS CITY SSTATE ZIP O PHONE �'r L O f 0 ,3b �33 �El� 9��29 J DIRECTIONS n TO JOB SITE C0 A)C-P— !h .86ACd QGnn 0UJ SC(F i2 Ld 4.A Lb Sht 10j. ST4rt m 7r. PARCEL ✓ LEGAL �!�'07 f NUMBE6�� �� �D aO DESCR �/Ey� nt SE SEG 29 Y� Z3 4 la) 7,2 NAME MAILADDRESS CITY SSTATE LICENSE NO. ZIP PH NE CONTRACTOR USE OF BUILDING CA2 WAS CLASS OF NEW ✓ ADDITION ALTERATION REPAIR MOVE REMOVE WORK ✓ DESCRIBE p WORK L c8itt / S u A S G J. ST M. /Z 3 4. 3 SV d Zo o d B rai 1-31 sex, .&AD Ret ,t3 6646 .Zo". BEDROOMS DECKS CARPORT NOTICE SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR BATHROOMS TOTALSQ.FT. GARAGE CONDITIONING. NO.OF STORIES BASEMENT ATTACHED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 SAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR TOTALSQ.FT. FIREPLACE DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANYTIME AFTER WORK IS COMMENCED. PERMANENT SHORELINE SEASONAL OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONFORMANCE TH WEWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAINING APPR VAL Iu1 THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT. X OWNER D�E 'z T S X BY DATE FOR OFFICE USE ONLY DEPARTMENT Y SPPROVEDVO DEPARTMENT YESPPROVEDIO BUILDING VALUATION HEALTH PUBLIC WORKS FEE PLANNING FIRE BUILDING PERMIT D.O.T. BUILDING PLAN CHECK SPECIAL CONDITIONS BUILDING GROUP PRE-INSPECTION SHORELINE WOODSTOVE PLUMBING MECHANICAL STATE BUILDING FEE STATESURCHARGE APPLIC ION ACCEPTED BY PLANS CHECK BY APPROVED FOR ISSUANCE PERMIT VALIDATION TOTAL BY CASH CK MO MASON COUNTY DEPARTMENT of GENERAL SERVICES Courthouse Annex I N. Fourth & W. Cedar P.O. Box 186 Shelton, Washington 98584 (206) 427-967.0 building environmental health maintenance . landfill parks&recreation fair/convention center planning sewer&water Mr . Ivan L. Davies June 7, 1989 P.O. Box 433 Bel -fair, WA. 95528 Dear Mr. Davies, Enclosed , please find a copy of a comment letter from the Mason County Engineer' s Office regarding the proposed car wash to be located at the corner of Roy Boad Road , Old Bel -fair Highway and North Shore Road . Your building permit application has been reviewed by the Engineering Department for such things as ingress and egress from county roads, drainage, etc . The Mason County Health Department has also briefly reviewed your proposal and commented that an area for the drainfield is not designated on the submitted plans nor have test holes been dug . Please contact the Health Department regarding these issues and any other questions you may have regarding sewage disposal . The Mason County Planning Department has also reviewed your proposal to construct a car wash and have the following comments: -Environmental issues need to be addressed . Please contact Mr-. Greg Cloud of the Department of Ecology at phone number (206) 753-0142 to see if any approvals are necessary, for your proposal . -Your building permit application will continue to be processed when we have received the information listed above and enclosed . If you have any questions or I can be of further assistance, do not hesitate to call . Than; you. Sincerely, Lenore Marl<en , Planner Dept . of General. Services Enclosure LM/ lm i MASON COUNTY Public Works Director/County 9 Road Engineer Shelton , Washington 98584 Inter-Departmental Communications June 2, 1989 To: General Services - Lenore Markin From: Count Eng ineer 's gineer 's Office- Elden St_tbj: Review of Commercial Building Permit - Ivan L. Davies Car, Wash in Belfair I have reviewed the above proposed commercial project and find the following needs to be corrected: 1) The inlet access from the Roy Boad Road needs to be moved to the east edge of the property, to obtain maXimum distance from the stop sign at the Old Belfair Hwy. ) One outlet access needs to be eliminated . The other one needs to be moved to the north edge of the property, on the Old Belfair Hwy. , to obtain maximum distance from the intersection with S.R.300. ?) The septic drain field must be designed so that there would be no over flow from. it to the storm water retention system. 4) The storm water retention system must be designed to retain the addition rain water run off on site that would run off due to covering the land with buildings or pavement . Mote: the Roy Boad Road intersects the Old Belfair Hwy. directly opposite S.R. 300. The commercial access permits for the accesses in question should be obtained prior to construction, to eliminate any confusion as to location. ELR: elr r � . t -.•7 F.L .. + > -`-'i"" .�'x''y ..,,v. 4�2 y -... r f •°.L. �r'e- y.,�-�--�1'��r:^eXle s��•- T.�r 3�...,,, wr�••cc _ APROV i .. .. i4 ERFLOIY. 70 SAnorARr.sEwEq: NOTE Ui//ass: O/hecwise: SpecifieQ! . rA: ,t _�,-_—. ALL DIAIENSlONS. a DETAIL'S: ARE SUGGEST/OHS ONLY: CONSULT LOCAL CODES: FOR:' SRECIE/C.. REQUIRE MENU. i MANHOLE FL+USN' /1•TH%Ti p l _J 'Jr 1��SULU L•r`."(TY. 1 . � i•I t I ENV/ROvM£NTAL/ST Q' /NST CONSULT" ALLAT/ON� DRAw/NG.�/3-/OBOZ/00' i .MANHOLE I f!( ! 2�HOSE CONR4RTMENTI II - L t _ II 4"PIPE BU/LD-iffl 2'FEMALE AROUND' CO(/PL/NG ON;7"P/P£ FROM COMPARTMENT II SEE SECT/ON.B-B . -_ ——— '✓ ' I CONCRETE- - 4.Li4A/N.P/PE _ CLEAN:OY/T PLUG , F UI t, MAN//O[E (SLOP£/T71 ,BLANK. COVFR ' BL'A/VK'COVER. - (2'TYP.CAU' I •� / TEFL'GRATE. TO,SAN/TARP CONCRETE' c - I SEwEgr �-- - -•i I P/T STEEU CRATE P t . E �[ I .I S!O COMPARTMENT COMPARTMENT 5=b�. TO AV0102 CLOOS.,S000EST U31NQ K,'rSO•NESN ' FILTER:SCREEN;ATT INLET POINT:OE PIPE_ - e I - i f -: I /Q•• _- -_ /,SOO GALTANK - •/500 GAL.TANK L NOTE I• p:: I I PIT, H:TANKS, CAN. HE PgE-QAST, %4.� i I - ;\ %t :.:y4'�:': ;'P'::.::Y.i'•:::'.✓:.,,-•:::• ..':. ' #;�-:,'-.r.'n{:;.� OR: CAST/N.'PLACr C4vCRET£ ' 4.•_O/ I' DEPTH'OF TANKS: . / .•i... ••I. I f SLOPE OF 4'DRAX,PI PIPE.FROM. P?..SUGGESTED-SLOPE-O-11M.. ,. x } •11 II 0 ,... f 4•TYP./CAL f. �� i- i - G•b" �'D"'-- t• - 1'=0'" r I �OROUND,OUTSIDE ORATED INSIDE Tme- E -- l+ SEC VON`A`A;, eAYc. . ACCESIBILITY:FOR.REPAIRS: MUST., / �' -BE CONSIDERED;WHEN:LOCATING' A TANKS' f t ENTER �. ! 2�P/PE TO' ENV/gONAI£vTAL/ST.IT r ! _ COMPARTMENT II v:;T FOOT VALVE H STRAINER. I 1 I SECT/ON B-B F; APPLICATION i NATERIAD 'TOLERANCE V _ x PRODUCT • NEXT.ASS'Y iXX: R•E-KO M�G. CO:, F •O3 DES MOINES IOWA.50317 : '=-84-14 C �EV(bE M4N+k"t 5U/E.- ;RYKO 584 [ ( ixxx. .010 v DKAfII 01xGYAp ,.'�-6-t34� ( I SCALE:NON£ .AVP110vED ti: I RYKO 784 '- I ANGULAR t 5" DATE: 9-9-80 i ,/'•� CRKD: I9SI-17+ B : ADD NOTES 9.22•EI ASNOTED ' A SEE eco• -3-0-91'; i 'BREAK ALL. 'TYP/CAL SINGLE BAY LAYOUT-EVd ECO'- LTfl WAS DATE AAVD j EDGES AND I REVISIO�US ' DEBURR ALL. ;oRAwixO eo. ,RE,,,M. ,. _ REVISIONS- t HOLfiS i IJ-124.65-000