Loading...
HomeMy WebLinkAboutFire Alarm System - FIR Inspections - 10/15/2009 0111012010 10: 10 36030 TRI TEK SYSTEMS PAGE 04 Tri-Tek Systems FOR THE CITY OH. ' 8527 Knute Lane NtV - 1 -600 09 Silverdale;WA 98383 Voice: (360) 373-8373 Fire Alarm ys em Confidence .Report: Fax: (360)308-0254 Central Station Account No. IZ. , .3 ARW dr l Z Occupied as (major tenant)RU-' IbU I C-E Address -5861 KI, E 5-TP CE R'N TE -4 5 Zip Code 19 �9 Phone No. �_ %O "off Type of test: Monthly Quarterly Semi-Annual nua Acceptance Number of initiating circuits Number of signaling circuits Fire control panel manufacturer NLE ENT K WG M Model No. Central Station transmitter manufacturer 7 Model No. Sze) 2 Battery voltagE 7-7 I Charge circuit voltage Z-7 Battery under load 4 zs Alarms tripped by which initiating circuit CENTRAL S'i`ATION , FIRE CONTROL FAN EL TRANSMITTER Smoke detectors cleaned? System operates on AC power ❑No M NA files ❑No 'Alarm Silence'results in tbl.sig. 1 Cs 13 No 0 NA [ pfes El No Loss of AC results in trouble signal Ives ❑No ❑NA Q"�►�Y, s Ell No System,operates on battery. p es ❑No ❑NA is 4s ❑No All circuits Checked for oleo.Supv. �oYe ❑No ❑NA f les ❑No Test meets fanufacturer's specs. El No D.;NA [ 'e ❑No All auxiliary equipment operates l�Wp�s 0 No 0 NA � Key to file control panel available t�al'',Yres ❑No ❑ NA- Operating instructions posted IG1'r ❑No ❑NA r�l ves 0 No Test record posted at control panel C�l�fes ❑ No ❑NA s 0 No Automatic time delay of general alarm minutes Time initiated Time received by Central,Station ` EQUIPMENT TESTED OF UNITS SATISFACTORY N0.OF UNITS- NO. ' TYPE OF EQUIPMENT TESTED YES NO NA., 1N BUILDINGS Bells, Horns,Chimes,Voice Alarms,Speakers,Water Gongs- . Visual Alarm Devices Trouble Indicators 7 Heat.Detectors Smoke Detectors Sinoke•Beams Sprinkler Waterflow Alarms Sprinkler Supervisoy Switches Manual Pull Stations 7 Ventilation Controls O erate Annundiators Elevator Recall 'Fire Dampers/Smoke Dampers Phone.lacks Automatic Door Relaase i. Other ' This is to cerOj that this tire alarm system/central station transmitter has been properly testod and inspected for reliability to Cover the items flared in this report,is conslstent with fire alarm maintenance standards!manufacturer's requirements,and all corrections have been'/have not,boen made. ;Signature of Inspector Date Problems Found �" �� +• Corrections Made �04/.12/2012 07:39 3803080254 TRI TEK #2000 P. 003/007 ._ ysfe F:O�It:'Fii�'GI'TY O� E L1�' Tip:. eT .: ms ' •A5Z7•'Knafc I;.arie NW • - . :;••..,: ' ' . . . Sllver6 WA-98383.' 'i-•'.,' '�V(�icc_'•(3fiQ)'373=$3Z3• :'.`••�F .•, :. Fax; (360)3C)9_ 254: " ire: lla Sj-stein Con, deiae epo •. :c6ritral.Station'Account Occupied as'(major tenant) Address �t Zip Code C)A5.7 Phone No. CQ' 4 i'' EEL& ' Type of test: Monthly Quarterly ' Semi-Annual " nnual Acceptance Number of initiating circuits• Number of signaling circuits z Fire control panel manufacturer .�]' ..� � � Model No.' .ZL ' Central Station transmitter manufacturer„ S UL MT V%M (W T Model'-No. 5'261�S f3attery voltage' ' ; �.. Change circuit voltage .'�� Battery under load Z,�i A .4J• Alarms tripped by.whickt:initiating circuit ALL 'CENTRAL STATION . Smoke detectors'cleaned? FIRE CONTROL PANEL TRANSMITTER $ysterit operates on AC power s R No, w ❑NA p�Y s ❑No Alarm Silence"'rasrsits in tbl.sig.- .• l3'No a.NA tg as ❑No Loss of•AC-,resutts in trouble'signal s 1 13 No CI-NA ❑No Sys tam:bperates'on:baMry -0 No ❑NA ❑No All circuits checked..for efec.supv. s Q No ❑NA �Ye� l3 No Test meets manufacturer's spars-• 0 No ❑P1A • ' Woes 0 No Ail auxiliary'equ pmentoperates ❑No v NA Key to fire control panel available ,E.: ❑No ❑NA. Operating instructions.posted. 4 : 9S. ❑No U NA Test record posted at control panel i>IiYes ❑No ❑NA Vas ❑No Automatic time delay of general alarrrr minutes Time initiated Time received by Central Station . "r4 i EQUIPMENT TESTED NO.OF UNrrS SATISFACTORY.. NO.OF UNITS TYPE OF EQUIPMENT TESTED • YES NO -NA IN BUILDING -galls,Horns,Chimes,.Voide'Aiarrris,Speakers,Water Gongs'' Visual Alarm•Devices`• .Trouble Indicators7. Heat Detectors ML Smoke Detectors , -smoke Beams Sprinkler Waterflow Alarms:, Sprinkler Supervisory Switches• Manual Pull Stations': Ventilation Controls O eiate'' Annunciators Elevator Recall Fire Dam 'ers•/Smoke Dam ers r Phone Jacks. -Auto.rhatic Door Release trier 'this is to,certify that•this fire alarm-system-/. central station transmitter has been properry tested and inrpec.•ted for reliability td caver•the items fisfled in thisYepoR,is coneisteni with fire alarm maintenance standards/manufacturer's requirements,and all corrections have been/have riotbeerr'made• Signature of•Inspector Date • ZA 'W I I Problems Found ��� A' k i; , Corrections Made '