HomeMy WebLinkAboutCOM2003-00197 Final Office Bldg - COM Permit / Conditions - 11/12/2004 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186
Phone: (360)427-9670,ext.352
Shelton,WA 98584
COMMERCIAL BUILDING PERMIT COM2003-00197
OWNER: CADY FAMILY RECEIVED: 11/26/200,
CONTRACTOR: STEPHEN JOHNSON INC LICENSE: STEPHJ*199LW EXP: 6/1/2004 ISSUED: 3/10/2004
SITE ADDRESS: 23861 NE STATE ROUTE 3 BELFAIR EXPIRES: 9/10/2004
PARCEL NUMBER: 123294100090
LEGAL DESCRIPTION: TR 9 OF NE SE EX TR 9-A 23861 NE STATE RT 3 BELFAIR
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW OFFICE BUILDING TAKE SR3 TO BELFAIR SITE IS LOCATED NEXT TO THE CLIFTON LANE
INTERSECTION STOP LIGHT NEAR SAFEWAY
General Information Construction &Occupancy Information
Type of Use: OFFICES Insp.Area: No.of Units: Type of Constr.: V-N
Type of Work: NEW Fire Dist.: 2
No.of Bathrooms: Occ. Group: B
Valuation: $ 237,449.75 No.of Stories: 1 Occ. Load: 43
Building Height: 26
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building: 3,595
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: 10.00 Ft. Shoreline: Ft.
Rear: 10.00 Ft. Slope: Ft. Water Body:none Shoreline Desig.: Not Applicable
Side 1: 10.00 Ft. SEPA?:No Comp.Plan Desig.: Urban Growth Area
Side 2: 10.00 Ft.
Fire Protection System Information
Auto Fire Alarm System?: Y Emergency Key Box?: Y Standpipe?: N
Auto Fire Sprinkler System?: N Access Road?: Y Fire Extinguishers?: Y
Fixed Fire Suppression System?: N Fire.Hydrants?: Y Fire Lanes?: Y
COM2003-00197 Please refer to the following pages for conditions of this permit.
1 of 5
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty, Type By Date Amount Receipt
Dishwasher 1 Exhaust Hood 1 Plan Check Fee TW 11i9FiI9nn %1 1aR,?R G19nn:inn
Hosebibs 1 Furnace<100K 2 Planning Com.Permit TW 1119F',l9nn c�9Rn nn G19nminn
Kitchen Sink 1 Unit Heater 3 Non-Res.Energy Code nl('. 19/1R/9nn R11 A Fn G99nnAnn
Lavatories 3 Heat Pump 2 Public Works Review AT 19i9Ri9nn T3a 99 G99nnAnn
Water Closets (Toilets) 3 UFC Plan Check Fee GAS 1/R/9nnd .057A 1A G99nnAnn
Water Heaters 1 Building State Fee KART 11Ri9nna TA Rn o99nnAnn
Building Permit Fee MR(, 1Isignna R1 7 R R.5F G99nnAnn
Mechanical Fee KART 11a19nna $Rd rs G99nnAnn
Mechanical Base Fee KART, 11Rr9nna .09.,1 sn G9?nnAnn
Plumbing Fee NARr, 11R19nna PRR nn G99nn4nn
Plumbing Base Fee MR(' 1/R/9nnA T,9n nn G99nninn
Public Works Review AT 91R19nna A 99 G99nnAnn
EH Plan Review r.FW n/.r,/9nna R7R nn G99nnAnn
Public Works Review AT ,AiglgnnA ssq 99 (;99nnAnn
Total $4,245.85
CASE NOTES FOR
COM2003-00197
CONDITIONS FOR
COM2003-00197
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-6647-0982. Thee/plg,�rsJo Sig ing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X '.' �7 i! �l�i71/
2) Xppr�ed per dimensions end setbacks on64e plan revised and stamped by planning staff showing 10'side yard setback minimum.
3) Parking shall be sufficient for 13 normal parking stalls (9 feet by 20 feet)and 1 handicap parking stall (12.5 feet by 20 feet)with sufficient
maneuvering aisles. Handicap stall shall be of a smooth surface at level or ramped to entry, located closest to the building entry, and shall be
signed with the International Symbol of Access. X
4) This application is s biect to Buffer and Landscaping requirements as established under Mason County Ordinance
1.03.036.X _A �
5) All approved plans are required to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be
granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason County
Building Department prior to any further inspections being performed or approvals granted. X
COM2003-00197 2 of 5
6) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY
BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION
FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF
OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
X _7A
7) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan is not on site, Approval WILL NOT
be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason
County Bp ding Department prior to any further inspections being performed or approvals granted.
X �r
8) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE
PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF l�S,� OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION.
CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x I t
9) Changes to approved building plans that affect compliance to the current non-residential Energy Code (NREC), ventilation and Indoor Air Quality
Code (xIQ) Uniform Building/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction.
X
10) CONSTRUCTION PROC SS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM
BUILDING CODE.x
11) All property lines shall be clearly identified at the time of foundation inspection. X �J
12) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-compli nwith Mason County ordinances and building regulations.
X
13) The mechanical system for which energy consumption, performance, or mode of operation are regulated by the 2001 Washington State Energy
Code (WSEC)and Ventilation And Indoor Air Quality Code (VIAQ)shall be tested to ensure that control devices, equipment and systems are
calibrated, adjusted and operate in accordance with approved plans and specifications. Drawings and notes shall require commissioning in
accordance with WSEC section 1416.4.
Lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in
accordance with the approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the
owner. Drawing notes shall require commissioning in accordance with WSEC 1513.7.
X �J
14) An automatic fire alarm system meeting Mason county and NFPA 72 standards Monitored by an approved UL certified central recieving station
shall be installed. A seperate plan review and.permit will be required. X I
2 -2A 10BC firms extinguishers installed in an approved location at no higher than 48"from the floor will be required.
X
A fire hydrant is required to be within 300' of the building. X
COM2003-00197 3 of 5
15) Emerg@nc4 vehicle access shall meet Mason County standards. Entrance shall be a minimum 20'wide with 25' interior/45'exterior turning radius.
X )'
Addres�,stll be located on the upper 25% of the building fronting the main access and shall be of a contrasting color.
X �J-J(
A Knox (emergency key box) Box shall be purchased from Mason County Fire Dist.
#2 and placed on the building in a location approved by the fire district. X
This permit becomes null and void if work or construction authorized is not oommenced within 180 days,or if construction or work is suspended fora period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of
work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWN ER OR AGENT: ��� � DATE: 1 O�
COM2003-00197 4 of 5
O :
N �COCRETE MECHANICAL MANUFACTURED HOME
o Footings / Set acks Date -m-Y By �� Ribbons
6 Date (5 12310 By �j(� Gas Piping Date By
'
o Foundation Walls Date B y Set-up
Date By INSULATION Date By
B G / Slab Insulation Floors Final
Date S- y By Date By Date By
FRAMING Walls FIRE D
Date' 7 ,L). ,d By Date By 7/Z Date 311&1 By
PLUMBING Attic OTH
Groundwork Date By
Date Jf=//-d y By %7Q WALLB A D NAILING
D.W.17 pL_ Date 0 MLI led B y 911s
Date f By�, FINAL I S ECTION
F
ater Line Date77-77 �te �`�-�-�PL( B y �� Date By
Ez8LOV
04 z� o!-t - cx( S� t(. KiLS F�, <SJE,5
��y� � ,—�r�„i [yJ`d�- �3,�1 c.�r� �✓�'$,oL' 1J cy,✓
�c Lr n 5 A C`P, rGCE N
L- o
cn
i
0
r-