HomeMy WebLinkAboutFIR2004-00038 Final Office - FIR Permit / Conditions - 10/1/2004 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(36 Phone: (360)427-9670,ext7262 ext.352 Mason County Bldg. 3 426 W. Cedar.P.O. Box 186 Shelton,WA 98584 I r®rlo t FIRE PROTECTION PERMIT FIR2004-00038 APPLICANT: REID REALTY. RECEIVED: 6/21/2004 CONTRACTOR: LICENSE: EXPO ISSUED: 7/30/2004 SITE ADDRESS: 23861 NE STATE ROUTE 3 BELFAIR EXPIRES: 1/30/2005 PARCEL NUMBER: 123294100090 LEGAL DESCRIPTION: ' TR 9 OF NE SE EX TR 9-A 23861 NE STATE RT 3 BELFAIR PROJECT DESCRIPTION: OFFICE i i INFORMATION I • System Information Type of Use: COMM Sprinkler Heads: 0 Audible Switches: 5 Pull Stations: 2 Fire District: 2 Flow Switches: 0 Visual Devices: 7 Door Releases: 0 Hood&Duct?: N Pressure Switches:: 0 Smoke Detectors: 9 Duct Detectors: 0 Dry Chemical?: N Zones: 1 Heat Detectors: 20 Wet Chemical?: N Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company. ACI First Floor: -4,500.00 Type Amount Due Amount Paid Monitoring Phone No.:(800)752-2490 Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Permit $100.00 $100.00 Auto. Fire Alarm Permit $39.25 $39.25 Auto. Fire Alarm Plan $90.51 $90.51 Total: $229.76 $229.76 FIR2004-00038 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FIR2004-00038 CONDITIONS FOR F Y IR2004-00038 1.) Move FACP to an area with direct exterior acc ss. X 4r All strobes are to s ncronized. X 1 This permit becomes null and void if r or construction authorised is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continu o of work is a progress inspgction thin the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of work is by means of a progress inspection. a ownerort"agent on t e ow rs behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and struc or or review and inspection. OWN ER OR AGENT: DATE: FIR2004-00038 P ease refer to the following pages for conditions of this permit. 2 of 3 N 'p CONCRETE MECHANICAL :MANUFACTURED HOME 6 o Footings/ Setbacks Date B y Ribbons owo Date By Gas Piping Date By Foundation Walls Date B y Set-up Date By INSULATION Date By B G / Slab Insulation Floors Final Date By Date By Date By FRAMING Walls FIRE DEPT Date By Date By Date By PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING D.W.V. Date By Date By FINAL SPECTI0 fD Water Line Date A5 (e B y w Date By Date By so 0 3 10 �GI y O a 0 0 C O s o r y w y O0 �C w O -h W FIRE(��& LLIFE SAcF_—ETY (INSPECTION: STATEMENT OF DEFICIENCY & CORRECTIVE ACTION ` NAMEFACILITM (6 2 lY \ __� V�`� ADDRESS CITY ZIP PHONE INSPECI'O AGENCY DAT DAVS- ZR 360-427-9670 X-273 MASON COUNTY FIRE MARSHAL FD ITEM CORRECTION STATEMENT OF CODE OR WAC CORRECTIVE ACTION NO. REQUIRED BY DEFICIENCY REFERENCE REQUIRED DATE wc �fr, LU - _: a Z O m O N V d X CaL W CC55 Z T.n O n 00 CIOU X N Q C m 00 •0 THE DEFICIENCIES DESCRIBED ABOVE HAVE BEEN SIGNATURE REINSPECTION DATE EXPLAINED TO ME, AND I AGREE TO MAKE CORRECTIONS NO LATER THAN THE DATES INDICATED t' - _ . PAGE�_OF I PAGES White Copy: Occupant—­Yelfow Copy:-Fire.Marshal—Pink Copy: Fire District Fire .Alarm Certificate of Completion `Business Name �1p� � Installation Company Business Address Z7SIRUI me H w 3 (rCompany Address 1 qZZ�,�p� Telephone number agQ 7-1 2StLs Telephone Number -N '3`� �'3'1-�_ Supplier `� kt ft,;c h, Business License Number 1.Type(s)of System or Service NFPA 72,Chapter 3-Local If alarm is transmitted to location(s)off premises,list wtiere signal is received: Address: Telephone: NFPA 72,Chapter 3-Emergency Volce/Alarm Service Quantity of voice/alarm channels: Single Multiple Quantity of speakers installed: Quantity of speaker zones Quantity of telephones or telephone jacks included in system: NFPA 72,Chapter S-Auxiliary Indicate type of connection; Local energy Shunt .Parallel telephone. Location of telephone numbers for receipt of signals: NFPA 72,Chapter 3-Remote Station Alarm: Supervisory: NFPA 72,Chapter 5-Proprietary If alarms are retransmitted to a public fire service communications center or other,indicate location and telephone numbers of the organization receiving alarm: Address: Telephone: Indicate how alarm is retransmitted: FPA 72,Chapter S-Central Station Prime contractor: AC Central station location: w Means oftransmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicato Two-way radio other Means of transmission of alarms to the public fire service communications center: (a) N System location: Organization name/phone Representative name/ one Installer �n TeK lsVb�s 3T3B373 thf-'r� �`I 37 3 g313 Supplier IC1 Alarm service organization "[-r= Tp may_ r,� .t 4e- NO 313 3 Location of record(as built)drawings: Location of owner's manuals: FA c.P Location of test reports: �k I F LP _....— A contract dated Jt5/a I I d 4 ,for test and inspection in accordance with NFPA standard(s)No(s). �J dated 1 is in effect. 2.Record of system Installation(Fill out after installation is complete and wiring checked for opens,shorts,ground faults, improper branching,but prior to conducting operational acceptance tests.) This system has been installed in accordance with the.NFPA standards as shown below,and was inspected by on roDO-1-to This system includes the following devices shown below,and has been in service since IVFPA 7 1999 edition, Chapter 3 S A , tional Electrical Code,article 760 anufacturer's mstructio Other(Specify) Signed: Date: 0 1 Organization: 3.Record of System Operation I/ f All operational features and functions of this system were tested by U L 4-� on t-_ �V f ! `�, and found to be operating properly in accordance with the requirements of- f NFPA 7 999 edition, Chapters 1Q2 a 4 6 NFPA 70, tional Electrical Code,article 760 ufacturer's instruc Other(Specify) nn Signed: Date: �� U Organization: - r 4.Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits(see NFPA 72,Table 3-5) Quantity: __�LStyle: L _ Class: MANUAL (a) 2--Manual.Stations ✓ Noncoded-activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: Partial: (a) l Smoke Detectors Ion /Photo (b) � _Duct Detectors Ion � Photo / (c) C1._Heat Detectors FT l RR ✓ FT/RR RC (d) Sprinkler Water-flow Switches: Transmission Noncoded,Activating Coded (e) Other(list): 1 rv� 5.Supe -Initialing Devices and Circuits(use blanks to indicate quantity of devices) GUARD'S TOUR (a) Codes stations (b) Noncoded stations,activating transmitters (c) Compulsory guard tout system comprised of transmitter stations and intermediate stations Note:Combination devices are recorded under 4(b)and 5(a). SPRU,TKLER SYSTEM (a) Code valve supervisory signaling attachments Valve supervisory switches,activating transmitters (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) Fire pump power (p Fire pump running () Phase reversal Engine-driven fire pump: (h) Selector in auto position (i) Engine or control panel trouble 4) Fire pump running Engine-driven generator: () Selector in auto position (1) Control panel trouble (m) Transfer switches (n) Engine running Other supervisory function(s) 6.Alarm notification Appliances and Circuits Quantity and ciass(See NFPA 72,Table 3-7)of notification appliance circuit s connected to the system: Types and quantities of notification appliances installed:Quantity: Z. Style: Class: (a) I Bells (y Inch (b) Speakers W Horns (d) Chimes (e) Other: (� ✓ Visual signals Type: c' '�'pbP_ _ with audible without audible (�) Local enunciator 7.Signalin r`euits PJA- tity and class(See NFPA 72,Table 3-6)of signaling line circuits connected to the system: Quantity Style: Class- 8.System Power Supplies (a)Primary(main): Nominal voltage: I Z OVA C— Current rating: Over current protection: Type: L�. Bar Location: P6.6 Z, E le G Glb Current rating: ZQ (b)Secondary(standby): II Storage battery: Amp hour rating: z h Calculated capacity to drive system,in hours: 24 V 60 Engine driven generator dedicated to fire alarm system: Location of fuel storage: (c)Emergency or standby system used as a backup to primary supply,instead of using a secondary power supply Emergency system described in NFPA 70,Article 700 Legally required standby system described in NFPA 70,Article 701 Optional standby system described in NEPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. 9.Software system (a)Operating system software revision level(s): (b)Application software revision level(s): _ l— (c)Revision completed by:Name �h aS- � Firm: 10.Comments: - - M b o all (signed)!br central sratton o se i pang w instal on cont=wrfsuppliw t# ) ) Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standards(s): System deviations from the referenced NEPA standards(s)are: 77 s gne o en ny or installation contractorisupplier Upon completion of the system(s)satisfactory test(s)witnessed(' (signed)by s representative of the i Fire Alarm Certificate of Completion :���Business Name ems. -- Installation Company JV S Business Address Z11SCol &3 ti r4.l 3 (rCompauy Address (yZ I ,t li i 51k. se b„i 1,J4 Telephone number Z 11 LES Telephone Number � o[ 7k-1-k Supplier �i 1� N�r, ft Business License Number 1.Type(s)of System or Service NFPA 72,Chapter 3-Local. If alarm is transmitted to location(s)off premises,list wtiere signal is received: Address: Telephone: NFPA 72,Chapter 3-Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single Multiple Quantity of speakers.installed: Quantity of speaker zones Quantity of telephones or telephone jacks included in system: NFPA 72,Chapter g-Auxiliary Indicate type of connection: Local energy Shunt .Parallel telephone. Location of telephone numbers for receipt of signals: NFPA 72,Chapter g-Remote Station Alarm: Supervisory: NFPA 72,Chapter 3-Proprietary If alarms are retransmitted to a public fire service communications center or other,indicate location and telephone numbers of the organization receiving alarm: Address: Telephone: Indicate how alarm is retransmitted: Oq�PA72,Chapt�5- entral Station '' __11 Prime contractor: A�� Central station location: �lJ/ Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicato Two-way radio other Means of transmission of alarms to the public fire service communications center: �a) System location: Organization name/phone Representative name/ one Installer �+-1 TGIF3T3�3T 3 r' M.,I Supplier �� _ -- Alarm service organization Tt= T2 4� t-r2.✓L c cal d2.. 3(9D 373 $ 7 3 Location of record(as built)drawings: FA-C_' _ Location of owner's manuals: FA cP Location of test reports: _ I ' �LP A contract dated In/a I/d 4 .for test and inspection in accordance with NFPA standard(s)No(s). dated 1 .is in effect. 2.Record of system Installation(Fill out after installation is complete and wiring checked for opens,shorts,ground faults, improper branching,but prior to conducting operational acceptance tests.) f, This system has been installed in accordance with the.NFPA standards as shown below,and was inspected by on a f t04 This system includes the following devices shown below,and has been in service since D 1VFPA 7 1999 edition, Chapter 3 5 A 7 , tional Electrical Code,article 760 anufacturer's mstruct�o Other(Specify) Signed: Date: Zo 1 la4 Organization: T ..- 3.Record of System Operation All operational features and functions of this system were tested by on V and found to be operating properly in accordance with the requirements of- NFPA 7 999 edition, Chapters g) 4 60 NFPA 70, donal Electrical Code, article 760 I nufacturer's instruc Other(Specify) Signed:- Date: Organization: 4.Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits(see NFPA 72,Table 3-5) Quantity: Style: Class: �J MANUAL (a) 2--Manual Stations ✓ Noncoded-activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete:_ Partial: (a) Smoke Detectors Ion'. Photo (b)_� Duct Detectors Ion Photo / (c) ICI_Heat Detectors FT 1 RR ✓ FT/RR RC (d) Sprinkler Water-flow Switches: Transmission Noncoded,Activating Coded (e) Other(list): ��11 Yv 5.Supe - 551daling Devices and Circuits(use blanks to indicate quantity of devices) GUARD'S TOUR (a) Codes stations (b) Noncoded stations,activating transmitters (c) Compulsory guard tout system comprised of transmitter stations and intermediate stations Note:Combination devices are recorded under 4(b)and 5(a). SPRINKLER SYSTEM (a) Code valve supervisory signaling attachments Valve supervisory switches,activating transmitters (b) Building temperature points (c) Site water temperature points (d Site water supply level points Electric fire pump: (e) Fire pump power (p Fire pump running W Phase reversal Engine-driven fire pump: (h) Selector in auto position @ Engine or control panel trouble 0) Fire pump running Engine-driven generator: () Selector in auto position (1) Control panel trouble (No Transfer switches (n) Engine running Other supervisory function(s) 6.Alarm notification Appliances and Circuits Quantity and class(See NFPA 72,Table 3-7)of notification appliance circuits connected to the system: Types and quantities of notification appliances installed:Quantity: Z. Style: Class: i (a) Bells 10 Inch @) Speakers W Horns (d) Chimes (e) Other: (fl ✓ Visual signals Type: n� r-pboe— _with audible without audible (�) Local enunciator 7.Signalin iue-C-Trcuits /V'- antity and class(See NFPA 72,Table 3-6)of signaling line circuits connected to the system: Quantity Style: Class- 8.System Power Supplies (a)Primary(main): Nominal voltage: OVA C-- Current rating: z�ft Over current protection: Type: C- Location: Q Z, E 19C,Gip Current rating: (b)Secondary(standby): II Storage battery: Amp hour rating: t ZA l , Calculated capacity to drive system,in hours: 24 60 Engine driven generator dedicated to fire alarm system: Location of fuel storage: (c)Emergency or standby system used as a backup to primary supply,instead of using a secondary power supply Emergency system described in NFPA 70,Article 700 Legally required standby system described in NFPA 70,Article 701 Optional standby system described in NEPA 70,Article 702,which also meets the performance requirements of Article 700 or 701. 9.Software system (a)Operating system software revision level(s): (b)Application software revision level(s): (c)Revision completed by:Name �hatXv-e� r� _ Firm: l r—j I�A/ S 10.Comments* o q(signed)for central station ohalmalil servide Mpan3M—rinsQ&V5—n cmdraetonlsupplier W1 Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standards(s): System deviations from the referenced NEPA standards(s)are: r 1 s gnet 77 i o an ny or ns a on con or supp er (titre) Upon completion of the system(s)satisfactory test(s)witnessed (signed)by a representative of the M 1 L Tri-Tel{. Systems FOR THE CITY OF i QV'3 CO V�^.,,�--L 1421 Sunset Vista Bremerton WA.98310 Phone/Fax 360-373-8373 Fire Alarm System Confidence Report Central Station Account No. 7�12 1-5'9 Occupied as(major tenant) -d � l2ecJ Address ek P S 1 AJ S f 2 Zip Code. '39i S- Phone No. ®r?7 7�- Type of Test: Monthly Quarterly Semi-Annual Annual Accep'�tan ec Number of Initiating circuits Number of signaling circuits Fire control panel manufacturer 1 1 Model No. - � t Central Station transmitter manufacturer -- Model No. Battery Voltage a ( / Charge Circuit Voltage e9lt l 1 Battery under load tom,�!J Alarms tripped by which initiating circuit�/4 1 i CENTRAL STATION FIRE CONTROL PANEL TRANSMITTER Smoke detectors cleaned? System operates on AC power lJ Yes ❑ No ❑ NA WYes ❑ No "Alarm Silence"results in tbl.sig. &�0Yes El No ❑ NA Yes ❑ No Loss of AC results in trouble signal 0 'YY s ❑ No ❑ NA Yes ❑ No System operates on battery l Yes ❑ No ❑ NA D�Yes ❑ No All circuits checked for elec.supv. ,QeYes ❑ No ❑ NA P'FYes ❑ No Test meets manufacturer's specs. l'l Yes ❑ No ❑ NA Yes ❑ No All auxiliary equipment operates Yes ❑ No ❑ NA Key to fire control panel available DfYes ❑ No ❑ NA Operating instructions posted U1 Yes ❑ No ❑ NA Test record posted at control panel lid Yes ❑ No ❑ NA a Yes ❑ No Automatic time delay of general alarm minutes Time initiated Time received by Central Station EQUIPMENT TESTED NO.OF UNITS SATISFACTORY NO.OF UNITS TYPE OF EQUIPMENT TESTED YES NO NA IN BUILDING Bells,Horns,Chimes,Voice Alarms,Speakers,Water Gongs 1 Visual AI.rm viceft 1 Trouble Indicators .. Heat Detectors TIJA Smoke Detectors 0 X Smoke Beams Sprinkler Waterflow Alarms Sprinkler Supervisory Switches ' Manual Pull Stations ! Ventilation Controls Operate Annunciators y 1 Elevator Recall Fire Dampers/Smoke Dampers Phone Jacks '�a, ,k'� Automatic Door Release Other THIS IS TO CERTIFY THAT THIS FIRE ALARM SYSTEM/CENTRAL STATION TRANSMITTER HAS BEEN PROPERLY TESTED AND INSPECTED FOR RELIABILITY TO COVER THE ITEMS LISTED IN THIS REPORT, IS CONSISTENT WITH FIRE ALARM MAINTANANCE STANDARDS MANUFACTURER'S REQUIRME'NTS,AND ALL CORECTIONS HAVE BEEN/HAVE NOT BEEN MADE. Signature of Inspector Date Problems Found Corrections Made